Brandon Schmandt
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Brandon Schmandt has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Dirk Scherler
Organic and Earth Surface Geochemistry GFZ Helmholtz Centre for Geosciences Potsdam Germany
1 shared publication - Evans Awere Onyango
University of New Mexico
1 shared publication Fan‐Chi Lin
Department of Geology and Geophysics University of Utah Salt Lake City Utah USA
1 shared publication- Fan‐Chi Lin
Department of Geology and Geophysics University of Utah Salt Lake City UT USA
1 shared publication Karl E. Karlstrom
Earth and Planetary Sciences Department University of New Mexico Albuquerque New Mexico USA
1 shared publicationKarl Karlstrom
Department of Earth and Planetary Sciences University of New Mexico Albuquerque New Mexico USA
1 shared publication
Latest Publications
- Open Access
- 1 July 2024
- Published by The Royal Society in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
- Vol. 382 (2276) , 20230181
Injection-induced basement seismicity beneath the Raton Basin: constraints from refined fault architectures and basin structure
Intraplate earthquakes induced by anthropogenic fluid injection present unexpected seismic risk to previously quiescent or low seismicity-rate regions. Despite many studies of induced seismicity, there are relatively few with detailed openly accessible constraints on the interaction between seismic sources and subsurface structures. In this study of the Raton Basin, we refine source observations from a dense nodal array and constrain basin structure using teleseismic receiver functions. The cross-correlation-based relocated hypocentres and a new set of focal mechanisms light up active fault segments and show clear spatiotemporal patterns. The geometric complexity of reactivated fault clusters appears greatest near higher rate injection wells. Simpler normal fault structure is found farther from injection wells and near abrupt structural transitions suggested by receiver functions. While less induced seismicity in the crystalline basement is expected when injection is >1 km from the top of the basement (like Raton), our receiver function analysis identified a basin thickness ~3 km beneath the nodal array and lateral variations in sedimentary structures. Our results explain potential fluid connectivity between the injection depths focused at ~1–1.5 km below the surface and basement fault activity that begins at ~3 km and reaches peak activity at ~4–8 km depths. This article is part of the theme issue ‘Induced seismicity in coupled subsurface systems’.
- 1 July 2024
- Published by The Royal Society in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
- Vol. 382 (2276) , 20230181
Open AccessInjection-induced basement seismicity beneath the Raton Basin: constraints from refined fault architectures and basin structure
Intraplate earthquakes induced by anthropogenic fluid injection present unexpected seismic risk to previously quiescent or low seismicity-rate regions. Despite many studies of induced seismicity, there are relatively few with detailed openly accessible constraints on the interaction between seismic sources and subsurface structures. In this study of the Raton Basin, we refine source observations from a dense nodal array and constrain basin structure using teleseismic receiver functions. The cross-correlation-based relocated hypocentres and a new set of focal mechanisms light up active fault segments and show clear spatiotemporal patterns. The geometric complexity of reactivated fault clusters appears greatest near higher rate injection wells. Simpler normal fault structure is found farther from injection wells and near abrupt structural transitions suggested by receiver functions. While less induced seismicity in the crystalline basement is expected when injection is >1 km from the top of the basement (like Raton), our receiver function analysis identified a basin thickness ~3 km beneath the nodal array and lateral variations in sedimentary structures. Our results explain potential fluid connectivity between the injection depths focused at ~1–1.5 km below the surface and basement fault activity that begins at ~3 km and reaches peak activity at ~4–8 km depths. This article is part of the theme issue ‘Induced seismicity in coupled subsurface systems’.
- 8 August 2018
- Published by Seismological Society of America (SSA) in Seismological Research Letters
- Vol. 89 (5) , 1597-1600
Preface to the Focus Section on Geophone Array Seismology
Although stand‐alone geophones have been used for decades within the active‐source seismic community (e.g., Mooney and Brocher, 1987), recent technological advances in geophone instrumentation have made it possible to use them for a wide range of passive seismic studies (e.g., Lin et al., 2013; Schmandt and Clayton, 2013). Compact, all‐in‐one seismic systems including a geophone, digitizer, and battery—often called nodes—are lightweight and easy to deploy, allowing large numbers of instruments (“large‐,” typically 100s or 1000s of nodes) to be used on a single project. These stand‐alone seismic systems, especially the RefTek 125A Texan seismometer...- 8 August 2018
- Published by Seismological Society of America (SSA) in Seismological Research Letters
- Vol. 89 (5) , 1597-1600
Preface to the Focus Section on Geophone Array Seismology
Although stand‐alone geophones have been used for decades within the active‐source seismic community (e.g., Mooney and Brocher, 1987), recent technological advances in geophone instrumentation have made it possible to use them for a wide range of passive seismic studies (e.g., Lin et al., 2013; Schmandt and Clayton, 2013). Compact, all‐in‐one seismic systems including a geophone, digitizer, and battery—often called nodes—are lightweight and easy to deploy, allowing large numbers of instruments (“large‐,” typically 100s or 1000s of nodes) to be used on a single project. These stand‐alone seismic systems, especially the RefTek 125A Texan seismometer...- Open Access
- 1 December 2015
- Published by American Geophysical Union (AGU) in Geophysical Research Letters
- Vol. 42 (23) , 10,290-10,298
Distinct crustal isostasy trends east and west of the Rocky Mountain Front
Seismic structure beneath the contiguous U.S. was imaged with multimode receiver function stacking and inversion of Rayleigh wave dispersion and ellipticity measurements. Crust thickness and elevation are weakly correlated across the contiguous U.S., but the correlation is ~3–4 times greater for separate areas east and west of the Rocky Mountain Front (RMF). Greater lower crustal shear velocities east of the RMF, particularly in low‐elevation areas with thick crust, are consistent with deep crustal density as the primary cause of the contrasting crust thickness versus elevation trends. Separate eastern and western trends are best fit by Airy isostasy models that assume lower crust to uppermost mantle density increases of 0.18 g/cm3 and 0.40 g/cm3, respectively. The former value is near the minimum that is plausible for felsic lower crust. Location of the transition at the RMF suggests that Laramide to post‐Laramide processes reduced western U.S. lower crustal density.
- 1 December 2015
- Published by American Geophysical Union (AGU) in Geophysical Research Letters
- Vol. 42 (23) , 10,290-10,298
Open AccessDistinct crustal isostasy trends east and west of the Rocky Mountain Front
Seismic structure beneath the contiguous U.S. was imaged with multimode receiver function stacking and inversion of Rayleigh wave dispersion and ellipticity measurements. Crust thickness and elevation are weakly correlated across the contiguous U.S., but the correlation is ~3–4 times greater for separate areas east and west of the Rocky Mountain Front (RMF). Greater lower crustal shear velocities east of the RMF, particularly in low‐elevation areas with thick crust, are consistent with deep crustal density as the primary cause of the contrasting crust thickness versus elevation trends. Separate eastern and western trends are best fit by Airy isostasy models that assume lower crust to uppermost mantle density increases of 0.18 g/cm3 and 0.40 g/cm3, respectively. The former value is near the minimum that is plausible for felsic lower crust. Location of the transition at the RMF suggests that Laramide to post‐Laramide processes reduced western U.S. lower crustal density.
- Open Access
- 15 September 2015
- Published by American Geophysical Union (AGU) in Geochemistry, Geophysics, Geosystems
- Vol. 16 (10) , 3343-3361
Teleseismic P wave spectra from USArray and implications for upper mantle attenuation and scattering
Teleseismic P wave amplitude spectra from deep earthquakes recorded by USArray are inverted for maps of upper mantle Δt* for multiple frequency bands within 0.08–2 Hz. All frequency bands show high Δt* regions in the southwestern U.S., southern Rocky Mountains, and Appalachian margin. Low Δt* is more common across the cratonic interior. Inversions with narrower frequency bands yield similar patterns, but greater Δt* magnitudes. Even the two standard deviation Δt* magnitude for the widest band is ∼2–7 times greater than predicted by global QS tomography or an anelastic olivine thermal model, suggesting that much of the Δt* signal is nonthermal in origin. Nonthermal contributions are further indicated by only a moderate correlation between Δt* and P travel times. Some geographic variations, such as high Δt* in parts of the cratonic interior with high mantle velocities and low heat flow, demonstrate that the influence of temperature is regionally overwhelmed. Transverse spectra are used to investigate the importance of scattering because they would receive no P energy in the absence of 3‐D heterogeneity or anisotropy. Transverse to vertical (T/Z) spectral ratios for stations with high Δt* are higher and exhibit steeper increases with frequency compared to T/Z spectra for low Δt* stations. The large magnitude of Δt* estimates and the T/Z spectra are consistent with major contributions to Δt* from scattering. A weak positive correlation between intrinsic attenuation and apparent attenuation due to scattering may contribute to Δt* magnitude and the moderate correlation of Δt* with travel times.
- 15 September 2015
- Published by American Geophysical Union (AGU) in Geochemistry, Geophysics, Geosystems
- Vol. 16 (10) , 3343-3361
Open AccessTeleseismic P wave spectra from USArray and implications for upper mantle attenuation and scattering
Teleseismic P wave amplitude spectra from deep earthquakes recorded by USArray are inverted for maps of upper mantle Δt* for multiple frequency bands within 0.08–2 Hz. All frequency bands show high Δt* regions in the southwestern U.S., southern Rocky Mountains, and Appalachian margin. Low Δt* is more common across the cratonic interior. Inversions with narrower frequency bands yield similar patterns, but greater Δt* magnitudes. Even the two standard deviation Δt* magnitude for the widest band is ∼2–7 times greater than predicted by global QS tomography or an anelastic olivine thermal model, suggesting that much of the Δt* signal is nonthermal in origin. Nonthermal contributions are further indicated by only a moderate correlation between Δt* and P travel times. Some geographic variations, such as high Δt* in parts of the cratonic interior with high mantle velocities and low heat flow, demonstrate that the influence of temperature is regionally overwhelmed. Transverse spectra are used to investigate the importance of scattering because they would receive no P energy in the absence of 3‐D heterogeneity or anisotropy. Transverse to vertical (T/Z) spectral ratios for stations with high Δt* are higher and exhibit steeper increases with frequency compared to T/Z spectra for low Δt* stations. The large magnitude of Δt* estimates and the T/Z spectra are consistent with major contributions to Δt* from scattering. A weak positive correlation between intrinsic attenuation and apparent attenuation due to scattering may contribute to Δt* magnitude and the moderate correlation of Δt* with travel times.
- Open Access
- 11 September 2014
- Published by American Geophysical Union (AGU) in Geophysical Research Letters
- Vol. 41 (18) , 6342-6349
P and S wave tomography of the mantle beneath the United States
- 11 September 2014
- Published by American Geophysical Union (AGU) in Geophysical Research Letters
- Vol. 41 (18) , 6342-6349
Open AccessP and S wave tomography of the mantle beneath the United States
- Top Cited Papers
- 13 June 2014
- Published by American Association for the Advancement of Science (AAAS) in Science
- Vol. 344 (6189) , 1265-1268
Dehydration melting at the top of the lower mantle
Cycling water through the transition zone: The water cycle involves more than just the water that circulates between the atmosphere, oceans, and surface waters. It extends deep into Earth's interior as the oceanic crust subducts, or slides, under adjoining plates of crust and sinks into the mantle, carrying water with it. Schmandt et al. combined seismological observations beneath North America with geodynamical modeling and high-pressure and -temperature melting experiments. They conclude that the mantle transition zone—410 to 660 km below Earth's surface—acts as a large reservoir of water. Science , this issue p. 1265
- 13 June 2014
- Published by American Association for the Advancement of Science (AAAS) in Science
- Vol. 344 (6189) , 1265-1268
Top Cited PapersDehydration melting at the top of the lower mantle
Cycling water through the transition zone: The water cycle involves more than just the water that circulates between the atmosphere, oceans, and surface waters. It extends deep into Earth's interior as the oceanic crust subducts, or slides, under adjoining plates of crust and sinks into the mantle, carrying water with it. Schmandt et al. combined seismological observations beneath North America with geodynamical modeling and high-pressure and -temperature melting experiments. They conclude that the mantle transition zone—410 to 660 km below Earth's surface—acts as a large reservoir of water. Science , this issue p. 1265
- Open Access
- 23 September 2013
- Published by American Geophysical Union (AGU) in Journal of Geophysical Research: Solid Earth
- Vol. 118 (10) , 5320-5338
Analysis of teleseismic P waves with a 5200‐station array in Long Beach, California: Evidence for an abrupt boundary to Inner Borderland rifting
We analyze teleseismic P waves from four Mw ≥ 6.5 earthquakes recorded by a petroleum industry survey in Long Beach, California. The survey used a 2‐D array with up to 5200 seismometers, 120 m mean spacing, and 7 – 10 km aperture. At frequencies near 1 Hz, P wave travel times and amplitudes exhibit coherent lateral variations over scales as short as ~400 m, including locally delayed travel times and increased amplitudes at the crest of the Long Beach anticline. Deeper heterogeneity is indicated by P wave phase velocities that deviate from reference model predictions for events from southwestern azimuths. We postulate that a sharp northeastward increase in Moho depth from the Inner Borderland (IB) to mainland southern California causes the anomalous phase velocities. Elastic forward modeling finds the travel times are fit well by a Moho that dips 65° to the northeast and flattens ~10 km southwest of the Newport‐Inglewood fault zone. Constraining the felsic thickness of mainland crust to 28 km requires an 8 km thick layer with a P‐velocity of 7 km/s beneath it, which could result from basal accretion of former Farallon ocean crust or magmatic underplating during Miocene volcanism. Forward models with a 65° Moho dip predict a P‐to‐s conversion with a phase velocity of ~5 km/s. Deconvolution of the array's mean P wave signal isolates a similar later arriving phase. The steep crust thickness transition supports a locally abrupt boundary to IB rifting. Our results highlight the utility of dense short‐period arrays for passive imaging at near surface to uppermost mantle depths.
- 23 September 2013
- Published by American Geophysical Union (AGU) in Journal of Geophysical Research: Solid Earth
- Vol. 118 (10) , 5320-5338
Open AccessAnalysis of teleseismic P waves with a 5200‐station array in Long Beach, California: Evidence for an abrupt boundary to Inner Borderland rifting
We analyze teleseismic P waves from four Mw ≥ 6.5 earthquakes recorded by a petroleum industry survey in Long Beach, California. The survey used a 2‐D array with up to 5200 seismometers, 120 m mean spacing, and 7 – 10 km aperture. At frequencies near 1 Hz, P wave travel times and amplitudes exhibit coherent lateral variations over scales as short as ~400 m, including locally delayed travel times and increased amplitudes at the crest of the Long Beach anticline. Deeper heterogeneity is indicated by P wave phase velocities that deviate from reference model predictions for events from southwestern azimuths. We postulate that a sharp northeastward increase in Moho depth from the Inner Borderland (IB) to mainland southern California causes the anomalous phase velocities. Elastic forward modeling finds the travel times are fit well by a Moho that dips 65° to the northeast and flattens ~10 km southwest of the Newport‐Inglewood fault zone. Constraining the felsic thickness of mainland crust to 28 km requires an 8 km thick layer with a P‐velocity of 7 km/s beneath it, which could result from basal accretion of former Farallon ocean crust or magmatic underplating during Miocene volcanism. Forward models with a 65° Moho dip predict a P‐to‐s conversion with a phase velocity of ~5 km/s. Deconvolution of the array's mean P wave signal isolates a similar later arriving phase. The steep crust thickness transition supports a locally abrupt boundary to IB rifting. Our results highlight the utility of dense short‐period arrays for passive imaging at near surface to uppermost mantle depths.
- Open Access
- 13 September 2013
- Published by American Geophysical Union (AGU) in Geophysical Research Letters
- Vol. 40 (18) , 4858-4863
Multiple fluvial processes detected by riverside seismic and infrasound monitoring of a controlled flood in the Grand Canyon
As rivers transport water and sediment across Earth's surface, they radiate elastic and acoustic waves. We use seismic and infrasound observations during a controlled flood experiment (CFE) in the Grand Canyon to show that three types of fluvial processes can be monitored from outside the channel. First, bed‐load transport under conditions of evolving bed mobility is identified as the dominant seismic source between 15 and 45 Hz. Two lower‐frequency seismic bands also excited by the CFE exhibited greater power increases and are consistent with source processes related to fluid rather than sediment transport. The second fluvial seismic source is inferred to be fluid tractions on the rough riverbed, which drive the maximum seismic power increase at 0.73 Hz, but do not excite infrasound. Waves at the fluid‐air interface are suggested as a third source, which generates a common 6–7 Hz peak in seismic and infrasound responses to the CFE.
- 13 September 2013
- Published by American Geophysical Union (AGU) in Geophysical Research Letters
- Vol. 40 (18) , 4858-4863
Open AccessMultiple fluvial processes detected by riverside seismic and infrasound monitoring of a controlled flood in the Grand Canyon
As rivers transport water and sediment across Earth's surface, they radiate elastic and acoustic waves. We use seismic and infrasound observations during a controlled flood experiment (CFE) in the Grand Canyon to show that three types of fluvial processes can be monitored from outside the channel. First, bed‐load transport under conditions of evolving bed mobility is identified as the dominant seismic source between 15 and 45 Hz. Two lower‐frequency seismic bands also excited by the CFE exhibited greater power increases and are consistent with source processes related to fluid rather than sediment transport. The second fluvial seismic source is inferred to be fluid tractions on the rough riverbed, which drive the maximum seismic power increase at 0.73 Hz, but do not excite infrasound. Waves at the fluid‐air interface are suggested as a third source, which generates a common 6–7 Hz peak in seismic and infrasound responses to the CFE.