Jason T. Lerner
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Interests
Jason T. Lerner has a total of 227 co-authors. Here are the top co-authors by number of shared publications:
Christopher C. Giza
Division of Pediatric Neurology Department of Pediatrics Mattel Children's Hospital – UCLA Los Angeles California U.S.A
3 shared publicationsRaman Sankar
2 shared publications- Rujuta B. Wilson
Mattel Children’s Hospital at UCLA
2 shared publications A. James Barkovich
1 shared publication- Adam Kirton
Department of Pediatrics University of Calgary Calgary Alberta Canada
1 shared publication - Adeline Vanderver
Department of Neurology, The Children's Hospital of Philadelphia, Philadelphia, PA, United States
1 shared publication
Latest Publications
- 7 November 2019
- Published by Springer Nature
- p. 551-584
Neurology
- 1 October 2016
- Published by Wolters Kluwer Health in Journal Of Clinical Neurophysiology
- Vol. 33 (5) , 426-430
Conductive Plastic Electrodes Reduce EEG Artifact During Pediatric ECMO Therapy
Extracorporeal membrane oxygenation (ECMO) is a life-saving heart and lung bypass procedure that can cause substantial EEG artifact. Continuous EEG monitoring is nonetheless a helpful neuromonitoring tool for patients receiving ECMO therapy because neurologic complications are frequent, but factors such as sedation, neuromuscular blockade, and hemodynamic instability limit clinical and radiographic evaluation. We examined whether using conductive plastic electrodes in place of conventional gold electrodes reduces artifact in clinical EEG studies of pediatric ECMO patients. Four masked electroencephalographers assessed artifact and its impact on overall EEG interpretation in samples from 21 consecutive EEGs recorded during ECMO therapy (14 gold and 7 plastic). A spectral power analysis then quantified 50- to 70-Hz artifact in a larger group of 14 gold and 34 plastic electrode studies during ECMO and 4 non-ECMO gold electrode studies. The masked electroencephalographers identified less artifact (P < 0.001) and indicated greater confidence in the accuracy of EEG interpretation (P < 0.001) among studies recorded with plastic electrodes. In quantitative analyses, ECMO was associated with greater 50- to 70-Hz power among studies using gold electrodes (P < 0.001) and gold electrodes exhibited greater 50- to 70-Hz power than plastic electrodes (P < 0.001). Contrasting studies in which most of the electroencephalographers believed that interpretation was (n = 12; 7 gold and 5 plastic) or was not (n = 7; all gold) compromised by artifact, 50- to 70-Hz power was similarly higher among the compromised studies (P < 0.001). Plastic electrodes substantially reduce the burden of electrical artifact in EEG studies performed on pediatric ECMO patients and improve confidence in EEG interpretation.
- 1 October 2016
- Published by Wolters Kluwer Health in Journal Of Clinical Neurophysiology
- Vol. 33 (5) , 426-430
Conductive Plastic Electrodes Reduce EEG Artifact During Pediatric ECMO Therapy
Extracorporeal membrane oxygenation (ECMO) is a life-saving heart and lung bypass procedure that can cause substantial EEG artifact. Continuous EEG monitoring is nonetheless a helpful neuromonitoring tool for patients receiving ECMO therapy because neurologic complications are frequent, but factors such as sedation, neuromuscular blockade, and hemodynamic instability limit clinical and radiographic evaluation. We examined whether using conductive plastic electrodes in place of conventional gold electrodes reduces artifact in clinical EEG studies of pediatric ECMO patients. Four masked electroencephalographers assessed artifact and its impact on overall EEG interpretation in samples from 21 consecutive EEGs recorded during ECMO therapy (14 gold and 7 plastic). A spectral power analysis then quantified 50- to 70-Hz artifact in a larger group of 14 gold and 34 plastic electrode studies during ECMO and 4 non-ECMO gold electrode studies. The masked electroencephalographers identified less artifact (P < 0.001) and indicated greater confidence in the accuracy of EEG interpretation (P < 0.001) among studies recorded with plastic electrodes. In quantitative analyses, ECMO was associated with greater 50- to 70-Hz power among studies using gold electrodes (P < 0.001) and gold electrodes exhibited greater 50- to 70-Hz power than plastic electrodes (P < 0.001). Contrasting studies in which most of the electroencephalographers believed that interpretation was (n = 12; 7 gold and 5 plastic) or was not (n = 7; all gold) compromised by artifact, 50- to 70-Hz power was similarly higher among the compromised studies (P < 0.001). Plastic electrodes substantially reduce the burden of electrical artifact in EEG studies performed on pediatric ECMO patients and improve confidence in EEG interpretation.
- 2 March 2016
- Published by Elsevier in Epilepsy & Behavior
- Vol. 57, 133-136
Electroencephalographic patterns during sleep in children with chromosome 15q11.2-13.1 duplications (Dup15q)
- 2 March 2016
- Published by Elsevier in Epilepsy & Behavior
- Vol. 57, 133-136
Electroencephalographic patterns during sleep in children with chromosome 15q11.2-13.1 duplications (Dup15q)
- 28 March 2015
- Published by Springer Nature
- p. 573-610
The Last Minute Review
- 28 March 2015
- Published by Springer Nature
- p. 435-456
Pediatric Neurology
- Open Access
Subclinical early posttraumatic seizures detected by continuous EEG monitoring in a consecutive pediatric cohort
Summary: Purpose: Traumatic brain injury (TBI) is an important cause of morbidity and mortality in children, and early posttraumatic seizures (EPTS) are a contributing factor to ongoing acute damage. Continuous video‐EEG monitoring (cEEG) was utilized to assess the burden of clinical and electrographic EPTS.Methods: Eighty‐seven consecutive, unselected (mild – severe), acute TBI patients requiring pediatric intensive care unit (PICU) admission at two academic centers were monitored prospectively with cEEG per established clinical TBI protocols. Clinical and subclinical seizures and status epilepticus (SE, clinical and subclinical) were assessed for their relation to clinical risk factors and short‐term outcome measures.Key Findings: Of all patients, 42.5% (37/87) had seizures. Younger age (p = 0.002) and injury mechanism (abusive head trauma – AHT, p < 0.001) were significant risk factors. Subclinical seizures occurred in 16.1% (14/87), while 6.9% (6/87) had only subclinical seizures. Risk factors for subclinical seizures included younger age (p < 0.001), AHT (p < 0.001), and intraaxial bleed (p < 0.001). SE occurred in 18.4% (16/87) with risk factors including younger age (p < 0.001), AHT (p < 0.001), and intraaxial bleed (p = 0.002). Subclinical SE was detected in 13.8% (12/87) with significant risk factors including younger age (p < 0.001), AHT (p = 0.001), and intraaxial bleed (p = 0.004). Subclinical seizures were associated with lower discharge King's Outcome Scale for Childhood Head Injury (KOSCHI) score (p = 0.002). SE and subclinical SE were associated with increased hospital length of stay (p = 0.017 and p = 0.041, respectively) and lower hospital discharge KOSCHI (p = 0.007 and p = 0.040, respectively).Significance: cEEG monitoring significantly improves detection of seizures/SE and is the only way to detect subclinical seizures/SE. cEEG may be indicated after pediatric TBI, particularly in younger children, AHT cases, and those with intraaxial blood on computerized tomography (CT).
Open AccessSubclinical early posttraumatic seizures detected by continuous EEG monitoring in a consecutive pediatric cohort
Summary: Purpose: Traumatic brain injury (TBI) is an important cause of morbidity and mortality in children, and early posttraumatic seizures (EPTS) are a contributing factor to ongoing acute damage. Continuous video‐EEG monitoring (cEEG) was utilized to assess the burden of clinical and electrographic EPTS.Methods: Eighty‐seven consecutive, unselected (mild – severe), acute TBI patients requiring pediatric intensive care unit (PICU) admission at two academic centers were monitored prospectively with cEEG per established clinical TBI protocols. Clinical and subclinical seizures and status epilepticus (SE, clinical and subclinical) were assessed for their relation to clinical risk factors and short‐term outcome measures.Key Findings: Of all patients, 42.5% (37/87) had seizures. Younger age (p = 0.002) and injury mechanism (abusive head trauma – AHT, p < 0.001) were significant risk factors. Subclinical seizures occurred in 16.1% (14/87), while 6.9% (6/87) had only subclinical seizures. Risk factors for subclinical seizures included younger age (p < 0.001), AHT (p < 0.001), and intraaxial bleed (p < 0.001). SE occurred in 18.4% (16/87) with risk factors including younger age (p < 0.001), AHT (p < 0.001), and intraaxial bleed (p = 0.002). Subclinical SE was detected in 13.8% (12/87) with significant risk factors including younger age (p < 0.001), AHT (p = 0.001), and intraaxial bleed (p = 0.004). Subclinical seizures were associated with lower discharge King's Outcome Scale for Childhood Head Injury (KOSCHI) score (p = 0.002). SE and subclinical SE were associated with increased hospital length of stay (p = 0.017 and p = 0.041, respectively) and lower hospital discharge KOSCHI (p = 0.007 and p = 0.040, respectively).Significance: cEEG monitoring significantly improves detection of seizures/SE and is the only way to detect subclinical seizures/SE. cEEG may be indicated after pediatric TBI, particularly in younger children, AHT cases, and those with intraaxial blood on computerized tomography (CT).
- 1 January 2012
- Published by Elsevier
Contributors