Olaf Stanger
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Olaf Stanger has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
Brigitta Gahl
Clinic for Cardiovascular Surgery, Inselspital, University Hospital Bern, Bern, Switzerland
4 shared publicationsHendrik Tevaearai
Clinic for Cardiovascular Surgery, Inselspital, University Hospital Bern, Bern, Switzerland
3 shared publicationsMichael Grabherr
Clinic for Cardiovascular Surgery, Inselspital, University Hospital Bern, Bern, Switzerland
3 shared publicationsAndreas Meinitzer
Department of Laboratory Medicine, Graz Auenbrugger University Hospital, Austria
2 shared publicationsFabian Gisler
Clinic for Cardiovascular Surgery, Inselspital University Hospital Bern, Bern, Switzerland
2 shared publicationsLars Englberger
Clinic for Cardiovascular Surgery, Inselspital, University Hospital, Bern, Switzerland
2 shared publications
Latest Publications
- 22 February 2020
- Published by Springer Nature
- p. 211-234
Die thorakale Aorta
- 22 February 2020
- Published by Springer Nature
- p. 95-112
Ausgewählte Aspekte: Aortenklappe und Aortenwurzel
- 22 February 2020
- Published by Springer Nature
- p. 95-112
Ausgewählte Aspekte: Aortenklappe und Aortenwurzel
- 1 March 2017
- Published by Elsevier in Heart, Lung and Circulation
- Vol. 26 (3) , 268-275
Freedom SOLO-Associated Thrombocytopaenia is Valve-Dependent and Not Due to In Vitro Pseudothrombocytopaenia
- 1 March 2017
- Published by Elsevier in Heart, Lung and Circulation
- Vol. 26 (3) , 268-275
Freedom SOLO-Associated Thrombocytopaenia is Valve-Dependent and Not Due to In Vitro Pseudothrombocytopaenia
- Open Access
- 17 September 2016
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 51 (2) , 340-346
Thrombocytopaenia after aortic valve replacement with stented, stentless and sutureless bioprostheses
OBJECTIVES: Use of the Freedom SOLO (SOLO) stentless aortic bioprosthesis is associated with a unique, and as yet unexplained, observation of postoperative low platelet count. Potential causes include the valve design, tissue and chemicals used for anticalcification treatment. This study compares the platelet response associated with the SOLO to mechanical, stented, sutureless and stentless valve prostheses. METHODS: In total, 1587 patients receiving mechanical ATS (n = 199), stented Perimount Magna (Perimount, n = 911), sutureless 3f Enable (n = 34) and Perceval S (n = 48), stentless Pericarbon Freedom (n = 29) or SOLO (n = 366) valves were analysed. The primary end-point was defined as maximum decrease in platelet count expressed as % reduction from baseline within 5 days of aortic valve replacement. RESULTS: The smallest decrease in platelets was observed for mechanical valves (44 ± 12%), followed by stented Perimount (50 ± 11%) and sutureless 3f Enable (53 ± 12%) bioprostheses. Compared with these valves, significantly greater reductions in platelets of 61 ± 14%, 60 ± 10% and 64 ± 12% were observed for the Pericarbon Freedom, Perceval S and SOLO, respectively. Multivariable linear regression analysis identified combined procedures, female gender, body surface area, date of operation and longer extracorporeal circulation time, but neither age nor valve size, as significant independent predictors for postoperative low platelet count. After adjustment, Sorin valves caused 13% (95% confidence interval 11–14) greater decrease in platelet counts compared with non-Sorin valves, but were associated with lower need for red blood cell [OR 0.56 (CI 0.41–0.75), P < 0.001] and platelet [OR 0.49 (CI 0.33–0.74), P = 0.001] transfusions. CONCLUSION: The Pericarbon Freedom, Perceval S and SOLO bioprostheses are associated with a significantly greater decrease in postoperative platelet count compared with non-Sorin valves. Use of these valves is, however, not associated with excess bleeding complications, suggesting a quantitative, rather than qualitative, transient side-effect on platelets. Our results argue for a cause associated with the anticalcification treatment using homocysteic acid.
- 17 September 2016
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 51 (2) , 340-346
Open AccessThrombocytopaenia after aortic valve replacement with stented, stentless and sutureless bioprostheses
OBJECTIVES: Use of the Freedom SOLO (SOLO) stentless aortic bioprosthesis is associated with a unique, and as yet unexplained, observation of postoperative low platelet count. Potential causes include the valve design, tissue and chemicals used for anticalcification treatment. This study compares the platelet response associated with the SOLO to mechanical, stented, sutureless and stentless valve prostheses. METHODS: In total, 1587 patients receiving mechanical ATS (n = 199), stented Perimount Magna (Perimount, n = 911), sutureless 3f Enable (n = 34) and Perceval S (n = 48), stentless Pericarbon Freedom (n = 29) or SOLO (n = 366) valves were analysed. The primary end-point was defined as maximum decrease in platelet count expressed as % reduction from baseline within 5 days of aortic valve replacement. RESULTS: The smallest decrease in platelets was observed for mechanical valves (44 ± 12%), followed by stented Perimount (50 ± 11%) and sutureless 3f Enable (53 ± 12%) bioprostheses. Compared with these valves, significantly greater reductions in platelets of 61 ± 14%, 60 ± 10% and 64 ± 12% were observed for the Pericarbon Freedom, Perceval S and SOLO, respectively. Multivariable linear regression analysis identified combined procedures, female gender, body surface area, date of operation and longer extracorporeal circulation time, but neither age nor valve size, as significant independent predictors for postoperative low platelet count. After adjustment, Sorin valves caused 13% (95% confidence interval 11–14) greater decrease in platelet counts compared with non-Sorin valves, but were associated with lower need for red blood cell [OR 0.56 (CI 0.41–0.75), P < 0.001] and platelet [OR 0.49 (CI 0.33–0.74), P = 0.001] transfusions. CONCLUSION: The Pericarbon Freedom, Perceval S and SOLO bioprostheses are associated with a significantly greater decrease in postoperative platelet count compared with non-Sorin valves. Use of these valves is, however, not associated with excess bleeding complications, suggesting a quantitative, rather than qualitative, transient side-effect on platelets. Our results argue for a cause associated with the anticalcification treatment using homocysteic acid.
- 20 June 2015
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 49 (3) , 1020.1-1021
Reply to Repossini and Bisleri
- 20 June 2015
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 49 (3) , 1020.1-1021
Reply to Repossini and Bisleri
- Open Access
- 9 February 2015
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 150 (1) , 70-77
The Freedom Solo pericardial stentless valve: Single-center experience, outcomes, and long-term durability
- 9 February 2015
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 150 (1) , 70-77
Open AccessThe Freedom Solo pericardial stentless valve: Single-center experience, outcomes, and long-term durability
- 1 February 2015
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 149 (2) , 644-645
Valve-in-valve: Estimating the risk of ostium obstruction in failed sorin stentless valves
- 1 February 2015
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 149 (2) , 644-645
Valve-in-valve: Estimating the risk of ostium obstruction in failed sorin stentless valves
- Open Access
- 1 December 2014
- Published by Taylor & Francis in Research Reports in Clinical Cardiology
- p. 349
The Freedom SOLO bovine pericardial stentless valve
The Freedom SOLO bovine pericardial stentless valve Olaf Stanger, Hendrik Tevaearai, Thierry Carrel Clinic for Cardiovascular Surgery, University Hospital Berne, Switzerland The third-generation bovine pericardium Freedom SOLO (FS) stentless valve emerged in 2004 as a modified version of the Pericarbon Freedom stentless valve and as a very attractive alternative to stented bioprostheses. The design, choice of tissue, and anticalcification treatment fulfill most, if not all, requirements for an ideal valve substitute. The FS combines the single-suture, subcoronary implantation technique with the latest-generation bovine pericardial tissue and novel anticalcification treatment. The design allows imitation of the native healthy valve through unrestricted adaption to the patient's anatomy, reproducing a normal valve/root complex. However, despite hemodynamic performance superior to stented valves, we are approaching a critical observation period as superior durability, freedom from structural valve deterioration, and nonstructural failure has not been proven as expected. However, optimal performance and freedom from structural valve deterioration depend on correct sizing and perfect symmetric implantation, to ensure low leaflet stress. Any malpositioning can lead to tissue fatigue over time. Furthermore, the potential for better outcomes depends on optimal patient selection and observance of the limitations for the use of stentless valves, particularly for the FS. Clearly, stentless valve implantation techniques are less reproducible and standardized, and require surgeon-dependent experience and skill. Regardless of whether or not stentless valve durability surpasses third-generation stented bioprostheses, they will continue to play a role in the surgical repertoire. This review intends to help practitioners avoid pitfalls, observe limitations, and improve patient selection for optimal long-term outcome with the attractive FS stentless valve. Keywords: aortic valve, bioprosthesis, cardiac surgery, aortic valve replacement, tissue valve, stentless aortic valve, hemodynamics, long-term results
- 1 December 2014
- Published by Taylor & Francis in Research Reports in Clinical Cardiology
- p. 349
Open AccessThe Freedom SOLO bovine pericardial stentless valve
The Freedom SOLO bovine pericardial stentless valve Olaf Stanger, Hendrik Tevaearai, Thierry Carrel Clinic for Cardiovascular Surgery, University Hospital Berne, Switzerland The third-generation bovine pericardium Freedom SOLO (FS) stentless valve emerged in 2004 as a modified version of the Pericarbon Freedom stentless valve and as a very attractive alternative to stented bioprostheses. The design, choice of tissue, and anticalcification treatment fulfill most, if not all, requirements for an ideal valve substitute. The FS combines the single-suture, subcoronary implantation technique with the latest-generation bovine pericardial tissue and novel anticalcification treatment. The design allows imitation of the native healthy valve through unrestricted adaption to the patient's anatomy, reproducing a normal valve/root complex. However, despite hemodynamic performance superior to stented valves, we are approaching a critical observation period as superior durability, freedom from structural valve deterioration, and nonstructural failure has not been proven as expected. However, optimal performance and freedom from structural valve deterioration depend on correct sizing and perfect symmetric implantation, to ensure low leaflet stress. Any malpositioning can lead to tissue fatigue over time. Furthermore, the potential for better outcomes depends on optimal patient selection and observance of the limitations for the use of stentless valves, particularly for the FS. Clearly, stentless valve implantation techniques are less reproducible and standardized, and require surgeon-dependent experience and skill. Regardless of whether or not stentless valve durability surpasses third-generation stented bioprostheses, they will continue to play a role in the surgical repertoire. This review intends to help practitioners avoid pitfalls, observe limitations, and improve patient selection for optimal long-term outcome with the attractive FS stentless valve. Keywords: aortic valve, bioprosthesis, cardiac surgery, aortic valve replacement, tissue valve, stentless aortic valve, hemodynamics, long-term results
- 8 October 2013
- Published by Wolters Kluwer Health in Circulation
- Vol. 128 (15) , 1602-1611
Type A Aortic Dissection After Nonaortic Cardiac Surgery
Background—: Cardiac surgery with cardiopulmonary bypass is associated with mechanical manipulation of the ascending aorta that occasionally leads to type A aortic dissection (AAD). Methods and Results—: One hundred three patients with surgical repair for AAD following nonaortic cardiac surgery were identified. With the use of logistic regression modeling, coronary artery bypass surgery (CABG), either isolated or combined with another procedure in the initial operation, was associated with significantly higher operative mortality in comparison with patients with non-CABG procedures at the time of AAD repair both for all patients (odds ratio, 2.90; 95% confidence interval, 1.09–7.72; P =0.033) and for patients with acute and chronic AAD ≥30 days after the initial operation (odds ratio, 3.62; 95% confidence interval, 1.13–11.54; P =0.03). In patients who developed AAD late after the initial operation, operative mortality was highest in patients without preoperative coronary angiography and appropriate management of their native coronary artery disease and graft disease (odds ratio, 5.36; 95% confidence interval, 1.68–17.0; P =0.002). Nearly all the intimal dissection tears were located at sites of previous surgical trauma. Most of the ascending aortas that had dissected initially had a diameter ≥40 mm with histological evidence of medial degeneration in resected tissue samples. Conclusions—: In patients who have undergone previous cardiac surgery, preexisting aortic wall pathology contributes to AAD with typical intimal damage at sites of mechanical trauma. The operative mortality was the highest in patients with previous CABG in comparison with patients with non-CABG procedures. Preoperative coronary angiography and operative management of native coronary and graft disease were significantly associated with outcome in patients with previous CABG.
- 8 October 2013
- Published by Wolters Kluwer Health in Circulation
- Vol. 128 (15) , 1602-1611
Type A Aortic Dissection After Nonaortic Cardiac Surgery
Background—: Cardiac surgery with cardiopulmonary bypass is associated with mechanical manipulation of the ascending aorta that occasionally leads to type A aortic dissection (AAD). Methods and Results—: One hundred three patients with surgical repair for AAD following nonaortic cardiac surgery were identified. With the use of logistic regression modeling, coronary artery bypass surgery (CABG), either isolated or combined with another procedure in the initial operation, was associated with significantly higher operative mortality in comparison with patients with non-CABG procedures at the time of AAD repair both for all patients (odds ratio, 2.90; 95% confidence interval, 1.09–7.72; P =0.033) and for patients with acute and chronic AAD ≥30 days after the initial operation (odds ratio, 3.62; 95% confidence interval, 1.13–11.54; P =0.03). In patients who developed AAD late after the initial operation, operative mortality was highest in patients without preoperative coronary angiography and appropriate management of their native coronary artery disease and graft disease (odds ratio, 5.36; 95% confidence interval, 1.68–17.0; P =0.002). Nearly all the intimal dissection tears were located at sites of previous surgical trauma. Most of the ascending aortas that had dissected initially had a diameter ≥40 mm with histological evidence of medial degeneration in resected tissue samples. Conclusions—: In patients who have undergone previous cardiac surgery, preexisting aortic wall pathology contributes to AAD with typical intimal damage at sites of mechanical trauma. The operative mortality was the highest in patients with previous CABG in comparison with patients with non-CABG procedures. Preoperative coronary angiography and operative management of native coronary and graft disease were significantly associated with outcome in patients with previous CABG.