    Non-Invasive Estimation of Central Systolic Blood Pressure by Radial Tonometry: A Simplified Approach

    by Denis Chemla, Davide Agnoletti, Mathieu Jozwiak, Yi Zhang, Athanase D. Protogerou, Sandrine Millasseau, Jacques Blacher

    Backround. Central systolic blood pressure (cSBP) provides valuable clinical and physiological information. A recent invasive study showed that cSBP can be reliably estimated from mean (MBP) and diastolic (DBP) blood pressure. In this non-invasive study, we compared cSBP calculated using a Direct Central Blood Pressure estimation (DCBP = MBP2/DBP) with cSBP estimated by radial tonometry. Methods. Consecutive patients referred for cardiovascular assessment and prevention were prospectively included. Using applanation tonometry with SphygmoCor device, cSBP was estimated using an inbuilt generalized transfer function derived from radial pressure waveform, which was calibrated to oscillometric brachial SBP and DBP. The time-averaged MBP was calculated from the radial pulse waveform. The minimum acceptable error (DCBP-cSBP) was set at ≤5 (mean) and ≤8 mmHg (SD). Results. We included 160 patients (58 years, 54%men). The cSBP was 123.1 ± 18.3 mmHg (range 86–181 mmHg). The (DCBP-cSBP) error was −1.4 ± 4.9 mmHg. There was a linear relationship between cSBP and DCBP (R2 = 0.93). Forty-seven patients (29%) had cSBP values ≥ 130 mmHg, and a DCBP value > 126 mmHg exhibited a sensitivity of 91.5% and specificity of 94.7% in discriminating this threshold (Youden index = 0.86; AUC = 0.965). Conclusions. Using the DCBP formula, radial tonometry allows for the robust estimation of cSBP without the need for a generalized transfer function. This finding may have implications for risk stratification.


  • Non-invasive Estimation of Aortic Blood Pressures: A Close Look at Current Devices and Methods

    by Sandrine Millasseau, Davide Agnoletti

    While for years clinicians have used cuff pressure to assess patients’ cardiovascular risk, recent evidences has shown that aortic pressure, or more specifically aortic systolic and aortic pulse pressures, have a better prognostic value to predict cardiovascular events and mortality. This led to the emergence of multiple methods and devices to assess aortic pressure non-invasively. Some use scaled waveforms measured at the carotid level with tonometry, or ultrasounds. Others use transfer function or mathematical modelling from radial or brachial traces acquired from volume plethsymography or applanation tonometry. Not all these techniques are equivalent and most of them have the major flaw of using brachial cuff pressure to scale their results. The purpose of this review is to present the strengths and weaknesses of techniques and various commercial devices to estimate aortic systolic pressure.


  • Validation of the new Complior sensor to record pressure signals non-invasively

    by Benjamin Sztrymf, Frédéric Jacobs, Denis Chemla, Christian Richard, Sandrine C. Millasseau

    The Complior device (Alam Medical, France) has contributed to the rise of arterial stiffness as a measure of cardiovascular risk. In its latest version (Complior Analyse) the sensor records pressure instead of distension waveforms thus allowing the measurement of central pressure and pulse wave analysis. The aim of our study was to verify that the new sensor measures pressure waveforms accurately in both time and frequency domain. Invasive and non-invasive signals were recorded simultaneously at the radial artery and compared in the frequency and time domain in haemodynamically stable intensive care unit patients. Twelve patients entered the study (8 men, 4 women, mean age 69 ± 17 years). Heart rate was 90 ± 15 bpm, systolic blood pressure 133 ± 19 mmHg and diastolic blood pressure 68 ± 15 mmHg. There was no statistical difference in the amplitude of harmonics between the invasive signal and Complior signal. When superimposing waveforms in the time domain, there was a small difference in the form factor (4.2 ± 2.8 %) and in the absolute area between the 2 waveforms (3.3 ± 1.7 mmHg·s−1). These differences were of the same magnitude as the beat-to-beat variation of the form factor (3.3 %) and of the absolute area (3.1 mmHg·s−1), respectively. The second systolic peak was detectable in 4 subjects, with no statistical difference between invasive and non-invasive values. The new pressure sensor of the Complior Analyse device recorded pressure waveforms accurately and could be used to perform pressure wave analysis.