Xiang Fang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Xiang Fang has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Chuan-Fan Ding
Shanghai Key Laboratory of Molecular Catalysis and Innovative Materials, Department of Chemistry and Laser Chemistry Institute, Fudan University, 220 Handan Road, Shanghai, China
5 shared publications Xinhua Dai
National Institute of Metrology, Beijing, China
5 shared publicationsFuxing Xu
Department of Electric Engineering, Fudan University, Shanghai, China
4 shared publicationsXingchuang Xiong
National Institute of Metrology, Beijing, 100013, China
4 shared publicationsMuyi He
College of Information Science, Shenzhen University, Shenzhen 518060, China; School of Life Science, Beijing Institute of Technology, No. 5 South Zhongguancun Street, Haidian Dist, Beijing 100081, PR China
3 shared publicationsQiankun Dang
Shanghai Key Laboratory of Molecular Catalysis and Functional Material, Department of Chemistry and Laser Chemistry Institute, Fudan University, Shanghai, China
3 shared publications
Latest Publications
Rapid characterization of structure-dependency gas-phase ion/ion reaction via accumulative tandem MS
- 25 May 2017
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 28 (7) , 1262-1270
Dual-Polarity Ion Trap Mass Spectrometry: Dynamic Monitoring and Controlling Gas-phase Ion–Ion Reactions
A dual-polarity linear ion trap (LIT) mass spectrometer was developed in this study, and the method for simultaneously controlling and detecting cations and anions was proposed and realized in the ...
- 25 May 2017
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 28 (7) , 1262-1270
Dual-Polarity Ion Trap Mass Spectrometry: Dynamic Monitoring and Controlling Gas-phase Ion–Ion Reactions
A dual-polarity linear ion trap (LIT) mass spectrometer was developed in this study, and the method for simultaneously controlling and detecting cations and anions was proposed and realized in the ...
- 5 May 2016
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 27 (8) , 1351-1356
Characteristics of Ion Activation and Collision Induced Dissociation Using Digital Ion Trap Technology
Collision induced dissociation (CID) is one of the most established techniques for tandem mass spectrometry analysis. The CID of mass selected ion could be realized by ion resonance excitation with...
- 5 May 2016
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 27 (8) , 1351-1356
Characteristics of Ion Activation and Collision Induced Dissociation Using Digital Ion Trap Technology
Collision induced dissociation (CID) is one of the most established techniques for tandem mass spectrometry analysis. The CID of mass selected ion could be realized by ion resonance excitation with...
- 1 February 2016
- Published by Science China Press., Co. Ltd. in SCIENTIA SINICA Chimica
- Vol. 46 (2) , 133-152
Recent advances in mass spectrometry based single cell analysis methods
不同的细胞个体之间具有差异性. 为了如实地反映细胞在结构和功能上对生物系统的正常运转所起到的作用, 就必须从单细胞水平上对细胞中物质的组成和含量进行分析研究. 但是单细胞分析研究却由于细胞的极小体积、极多的物质种类、极少的物质含量以及不同物质间显著的浓度差异而一度受阻. 质谱是一种很适合于单细胞分析的检测方法, 它具有极高的灵敏度、多物质同时检测的能力以及对所感兴趣的分子进行结构鉴定的能力. 不同的离子化方法对取样和前处理过程的要求也不同. 从某种意义上来说, 不同的离子化方法造就了不同的单细胞质谱分析方法. 因此, 本文从离子化方法学的角度对单细胞质谱分析方法进行了归纳和总结, 并进一步讨论了单细胞质谱分析在未来的发展趋势.
- 1 February 2016
- Published by Science China Press., Co. Ltd. in SCIENTIA SINICA Chimica
- Vol. 46 (2) , 133-152
Recent advances in mass spectrometry based single cell analysis methods
不同的细胞个体之间具有差异性. 为了如实地反映细胞在结构和功能上对生物系统的正常运转所起到的作用, 就必须从单细胞水平上对细胞中物质的组成和含量进行分析研究. 但是单细胞分析研究却由于细胞的极小体积、极多的物质种类、极少的物质含量以及不同物质间显著的浓度差异而一度受阻. 质谱是一种很适合于单细胞分析的检测方法, 它具有极高的灵敏度、多物质同时检测的能力以及对所感兴趣的分子进行结构鉴定的能力. 不同的离子化方法对取样和前处理过程的要求也不同. 从某种意义上来说, 不同的离子化方法造就了不同的单细胞质谱分析方法. 因此, 本文从离子化方法学的角度对单细胞质谱分析方法进行了归纳和总结, 并进一步讨论了单细胞质谱分析在未来的发展趋势.
- Open Access
- 26 January 2016
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 27 (4) , 596-606
Theoretical Study of Dual-Direction Dipolar Excitation of Ions in Linear Ion Traps
The ion enhanced activation and collision-induced dissociation (CID) by simultaneous dipolar excitation of ions in the two radial directions of linear ion trap (LIT) have been recently developed and tested by experiment. In this work, its detailed properties were further studied by theoretical simulation. The effects of some experimental parameters such as the buffer gas pressure, the dipolar excitation signal phases, power amplitudes, and frequencies on the ion trajectory and energy were carefully investigated. The results show that the ion activation energy can be significantly increased by dual-direction excitation using two identical dipolar excitation signals because of the addition of an excitation dimension and the fact that the ion motion radius related to ion kinetic energy can be greater than the field radius. The effects of higher-order field components, such as dodecapole field on the performance of this method are also revealed. They mainly cause ion motion frequency shift as ion motion amplitude increases. Because of the frequency shift, there are different optimized excitation frequencies in different LITs. At the optimized frequency, ion average energy is improved significantly with relatively few ions lost. The results show that this method can be used in different kinds of LITs such as LIT with 4-fold symmetric stretch, linear quadrupole ion trap, and standard hyperbolic LIT, which can significantly increase the ion activation energy and CID efficiency, compared with the conventional method.
- 26 January 2016
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 27 (4) , 596-606
Open AccessTheoretical Study of Dual-Direction Dipolar Excitation of Ions in Linear Ion Traps
The ion enhanced activation and collision-induced dissociation (CID) by simultaneous dipolar excitation of ions in the two radial directions of linear ion trap (LIT) have been recently developed and tested by experiment. In this work, its detailed properties were further studied by theoretical simulation. The effects of some experimental parameters such as the buffer gas pressure, the dipolar excitation signal phases, power amplitudes, and frequencies on the ion trajectory and energy were carefully investigated. The results show that the ion activation energy can be significantly increased by dual-direction excitation using two identical dipolar excitation signals because of the addition of an excitation dimension and the fact that the ion motion radius related to ion kinetic energy can be greater than the field radius. The effects of higher-order field components, such as dodecapole field on the performance of this method are also revealed. They mainly cause ion motion frequency shift as ion motion amplitude increases. Because of the frequency shift, there are different optimized excitation frequencies in different LITs. At the optimized frequency, ion average energy is improved significantly with relatively few ions lost. The results show that this method can be used in different kinds of LITs such as LIT with 4-fold symmetric stretch, linear quadrupole ion trap, and standard hyperbolic LIT, which can significantly increase the ion activation energy and CID efficiency, compared with the conventional method.
- 8 September 2015
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 87 (19) , 9745-9751
Desalting by Crystallization: Detection of Attomole Biomolecules in Picoliter Buffers by Mass Spectrometry
Sensitive detection of biomolecules in small-volume samples by mass spectrometry is, in many cases, challenging because of the use of buffers to maintain the biological activities of proteins and cells. Here, we report a highly effective desalting method for picoliter samples. It was based on the spontaneous separation of biomolecules from salts during crystallization of the salts. After desalting, the biomolecules were deposited in the tip of the quartz pipet because of the evaporation of the solvent. Subsequent detection of the separated biomolecules was achieved using solvent assisted electric field induced desorption/ionization (SAEFIDI) coupled with mass spectrometry. It allowed for direct desorption/ionization of the biomolecules in situ from the tip of the pipet. The organic component in the assistant solvent inhibited the desorption/ionization of salts, thus assured successful detection of biomolecules. Proteins and peptides down to 50 amol were successfully detected using our method even if there were 3 × 105 folds more amount of salts in the sample. The concentration and ion species of the salts had little influence on the detection results.
- 8 September 2015
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 87 (19) , 9745-9751
Desalting by Crystallization: Detection of Attomole Biomolecules in Picoliter Buffers by Mass Spectrometry
Sensitive detection of biomolecules in small-volume samples by mass spectrometry is, in many cases, challenging because of the use of buffers to maintain the biological activities of proteins and cells. Here, we report a highly effective desalting method for picoliter samples. It was based on the spontaneous separation of biomolecules from salts during crystallization of the salts. After desalting, the biomolecules were deposited in the tip of the quartz pipet because of the evaporation of the solvent. Subsequent detection of the separated biomolecules was achieved using solvent assisted electric field induced desorption/ionization (SAEFIDI) coupled with mass spectrometry. It allowed for direct desorption/ionization of the biomolecules in situ from the tip of the pipet. The organic component in the assistant solvent inhibited the desorption/ionization of salts, thus assured successful detection of biomolecules. Proteins and peptides down to 50 amol were successfully detected using our method even if there were 3 × 105 folds more amount of salts in the sample. The concentration and ion species of the salts had little influence on the detection results.
- 12 May 2015
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 87 (11) , 5561-5567
Enhancement of Ion Activation and Collision-Induced Dissociation by Simultaneous Dipolar Excitation of Ions inx- andy-Directions in a Linear Ion Trap
Collision-induced dissociation (CID) in linear ion traps is usually performed by applying a dipolar alternating current (AC) signal to one pair of electrodes, which results in ion excitation mainly in one direction. In this paper, we report simulation and experimental studies of the ion excitation in two coordinate directions by applying identical dipolar AC signals to two pairs of electrodes simultaneously. Theoretical analysis and simulation results demonstrate that the ion kinetic energy is higher than that using the conventional CID method. Experimental results show that more activation energy (as determined by the intensity ratio of the a4/b4 fragments from the CID of protonated leucine enkephalin) can be deposited into parent ions in this method. The dissociation rate constant in this method was about 3.8 times higher than that in the conventional method under the same experimental condition, at the Mathieu parameter qu (where u = x, y) value of 0.25. The ion fragmentation efficiency is also significantly improved. Compared with the conventional method, the smaller qu value can be used in this method to obtain the same internal energy deposited into ions. Consequently, the “low mass cut-off” is redeemed and more fragment ions can be detected. This excitation method can be implemented easily without changing any experimental parameters.
- 12 May 2015
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 87 (11) , 5561-5567
Enhancement of Ion Activation and Collision-Induced Dissociation by Simultaneous Dipolar Excitation of Ions inx- andy-Directions in a Linear Ion Trap
Collision-induced dissociation (CID) in linear ion traps is usually performed by applying a dipolar alternating current (AC) signal to one pair of electrodes, which results in ion excitation mainly in one direction. In this paper, we report simulation and experimental studies of the ion excitation in two coordinate directions by applying identical dipolar AC signals to two pairs of electrodes simultaneously. Theoretical analysis and simulation results demonstrate that the ion kinetic energy is higher than that using the conventional CID method. Experimental results show that more activation energy (as determined by the intensity ratio of the a4/b4 fragments from the CID of protonated leucine enkephalin) can be deposited into parent ions in this method. The dissociation rate constant in this method was about 3.8 times higher than that in the conventional method under the same experimental condition, at the Mathieu parameter qu (where u = x, y) value of 0.25. The ion fragmentation efficiency is also significantly improved. Compared with the conventional method, the smaller qu value can be used in this method to obtain the same internal energy deposited into ions. Consequently, the “low mass cut-off” is redeemed and more fragment ions can be detected. This excitation method can be implemented easily without changing any experimental parameters.
- 5 June 2014
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 86 (12) , 5733-5739
Novel Linear Ion Trap Mass Analyzer Built with Triangular Electrodes
A novel linear ion trap mass analyzer built with four triangular electrodes, the triangular-electrode linear ion trap (TeLIT), has been built and its performance has been characterized. The TeLIT has all the properties of a conventional LIT mass analyzer, performing ion trapping, mass analysis, and tandem mass spectrometry functions. The TeLIT was constructed with four identical triangular cross-section shaped electrodes and two planar electrodes. Unlike commercial LITs, which have very well-defined hyperbolic shaped electrodes, the TeLIT electrodes have a much simpler geometric structure and larger mechanical tolerances. The electric field distribution inside the IT region was simulated and there are more quadrupole field components and less higher order fields compared with those in other simplified ITs, such as cylindrical ion trap and rectilinear ion trap; hence, the instrument would potentially offer a relatively high mass resolution. In routine measurement, mass analysis with a resolving power of over 1500 at m/z = 609 Th was obtained. The TeLIT was shown to perform basic mass spectrometer functions such as mass-selected isolation, mass-selected ejection and collision-induced dissociation (CID) of ions comparable to other available LITs. Moreover, given the small size of the TeLIT and its simple structure and good analytical performance, further miniaturization and use as a portable mass spectrometer are envisaged.
- 5 June 2014
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 86 (12) , 5733-5739
Novel Linear Ion Trap Mass Analyzer Built with Triangular Electrodes
A novel linear ion trap mass analyzer built with four triangular electrodes, the triangular-electrode linear ion trap (TeLIT), has been built and its performance has been characterized. The TeLIT has all the properties of a conventional LIT mass analyzer, performing ion trapping, mass analysis, and tandem mass spectrometry functions. The TeLIT was constructed with four identical triangular cross-section shaped electrodes and two planar electrodes. Unlike commercial LITs, which have very well-defined hyperbolic shaped electrodes, the TeLIT electrodes have a much simpler geometric structure and larger mechanical tolerances. The electric field distribution inside the IT region was simulated and there are more quadrupole field components and less higher order fields compared with those in other simplified ITs, such as cylindrical ion trap and rectilinear ion trap; hence, the instrument would potentially offer a relatively high mass resolution. In routine measurement, mass analysis with a resolving power of over 1500 at m/z = 609 Th was obtained. The TeLIT was shown to perform basic mass spectrometer functions such as mass-selected isolation, mass-selected ejection and collision-induced dissociation (CID) of ions comparable to other available LITs. Moreover, given the small size of the TeLIT and its simple structure and good analytical performance, further miniaturization and use as a portable mass spectrometer are envisaged.
- 22 January 2014
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 25 (4) , 556-562
Resonance Activation and Collision-Induced-Dissociation of Ions Using Rectangular Wave Dipolar Potentials in a Digital Ion Trap Mass Spectrometer
Collision-induced dissociation (CID) of ions by resonance activation in a quadrupole ion trap is usually accomplished by resonance exciting the ions to higher kinetic energy, whereby the high kinetic energy ions collide with a bath gas, such as helium or argon, inside the trap and dissociate to fragments. A new ion activation method using a well-defined rectangular wave dipolar potential formed by dividing down the trapping rectangular waveform is developed and examined herein. The mass-selected parent ions are resonance excited to high kinetic energies by simply changing the frequency of the rectangular wave dipolar potential and dissociation proceeds. A relationship between the ion mass and the activation waveform frequency is also identified and described. This highly efficient (CID) procedure can be realized by simply changing the waveform frequency of the dipolar potential, which could certainly simplify tandem mass spectrometry analysis methods. Figure
- 22 January 2014
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 25 (4) , 556-562
Resonance Activation and Collision-Induced-Dissociation of Ions Using Rectangular Wave Dipolar Potentials in a Digital Ion Trap Mass Spectrometer
Collision-induced dissociation (CID) of ions by resonance activation in a quadrupole ion trap is usually accomplished by resonance exciting the ions to higher kinetic energy, whereby the high kinetic energy ions collide with a bath gas, such as helium or argon, inside the trap and dissociate to fragments. A new ion activation method using a well-defined rectangular wave dipolar potential formed by dividing down the trapping rectangular waveform is developed and examined herein. The mass-selected parent ions are resonance excited to high kinetic energies by simply changing the frequency of the rectangular wave dipolar potential and dissociation proceeds. A relationship between the ion mass and the activation waveform frequency is also identified and described. This highly efficient (CID) procedure can be realized by simply changing the waveform frequency of the dipolar potential, which could certainly simplify tandem mass spectrometry analysis methods. Figure