Gerit Kulik
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Gerit Kulik has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Constantin Schizas
University of Lausanne
3 shared publications Anne-Claude Griesser
1 shared publication- Antonio A. Faundez
Service de Chirurgie Orthopédique et de Traumatologie de l'Appareil Moteur, Hôpitaux Universitaires de Genève, Geneva, Switzerland
1 shared publication Antonio Foletti
1 shared publicationBarbara Kwiatkowski
1 shared publicationDamien Debatisse
Centre Hospitalier Universitaire Vaudois, The University of Lausanne
1 shared publication
Latest Publications
- 30 April 2014
- Vol. 10 (428) , 970-3
[Inter-hospital CHUV-HUG medical consensus of back pain management. Its application in care pathways within CHUV of Lausanne].
Back pain is a considerable economical burden in industrialised countries. Its management varies widely across countries, including Switzerland. Thus, the University Hospital and University of Lausanne (CHUV) recently improved intern processes of back pain care. In an already existing collaborative context, the two university hospitals in French-speaking Switzerland (CHUV, University Hospital of Geneva), felt the need of a medical consensus, based on a common concept. This inter-hospital consensus produced three decisional algorithms that bear on recent concepts of back pain found in literature. Eventually, a fast track was created at CHUV, to which extern physicians will have an organised and rapid access. This fast track aims to reduce chronic back pain conditions and provides specialised education for general practitioners-in-training.
- 30 April 2014
- Vol. 10 (428) , 970-3
[Inter-hospital CHUV-HUG medical consensus of back pain management. Its application in care pathways within CHUV of Lausanne].
Back pain is a considerable economical burden in industrialised countries. Its management varies widely across countries, including Switzerland. Thus, the University Hospital and University of Lausanne (CHUV) recently improved intern processes of back pain care. In an already existing collaborative context, the two university hospitals in French-speaking Switzerland (CHUV, University Hospital of Geneva), felt the need of a medical consensus, based on a common concept. This inter-hospital consensus produced three decisional algorithms that bear on recent concepts of back pain found in literature. Eventually, a fast track was created at CHUV, to which extern physicians will have an organised and rapid access. This fast track aims to reduce chronic back pain conditions and provides specialised education for general practitioners-in-training.
- 19 May 2013
- Published by Springer Nature in European Spine Journal
- Vol. 22 (9) , 2062-2068
A CT-based study investigating the relationship between pedicle screw placement and stimulation threshold of compound muscle action potentials measured by intraoperative neurophysiological monitoring
Neurophysiological monitoring aims to improve the safety of pedicle screw placement, but few quantitative studies assess specificity and sensitivity. In this study, screw placement within the pedicle is measured (post-op CT scan, horizontal and vertical distance from the screw edge to the surface of the pedicle) and correlated with intraoperative neurophysiological stimulation thresholds. A single surgeon placed 68 thoracic and 136 lumbar screws in 30 consecutive patients during instrumented fusion under EMG control. The female to male ratio was 1.6 and the average age was 61.3 years (SD 17.7). Radiological measurements, blinded to stimulation threshold, were done on reformatted CT reconstructions using OsiriX software. A standard deviation of the screw position of 2.8 mm was determined from pilot measurements, and a 1 mm of screw—pedicle edge distance was considered as a difference of interest (standardised difference of 0.35) leading to a power of the study of 75 % (significance level 0.05). Correct placement and stimulation thresholds above 10 mA were found in 71 % of screws. Twenty-two percent of screws caused cortical breach, 80 % of these had stimulation thresholds above 10 mA (sensitivity 20 %, specificity 90 %). True prediction of correct position of the screw was more frequent for lumbar than for thoracic screws. A screw stimulation threshold of >10 mA does not indicate correct pedicle screw placement. A hypothesised gradual decrease of screw stimulation thresholds was not observed as screw placement approaches the nerve root. Aside from a robust threshold of 2 mA indicating direct contact with nervous tissue, a secondary threshold appears to depend on patients’ pathology and surgical conditions.
- 19 May 2013
- Published by Springer Nature in European Spine Journal
- Vol. 22 (9) , 2062-2068
A CT-based study investigating the relationship between pedicle screw placement and stimulation threshold of compound muscle action potentials measured by intraoperative neurophysiological monitoring
Neurophysiological monitoring aims to improve the safety of pedicle screw placement, but few quantitative studies assess specificity and sensitivity. In this study, screw placement within the pedicle is measured (post-op CT scan, horizontal and vertical distance from the screw edge to the surface of the pedicle) and correlated with intraoperative neurophysiological stimulation thresholds. A single surgeon placed 68 thoracic and 136 lumbar screws in 30 consecutive patients during instrumented fusion under EMG control. The female to male ratio was 1.6 and the average age was 61.3 years (SD 17.7). Radiological measurements, blinded to stimulation threshold, were done on reformatted CT reconstructions using OsiriX software. A standard deviation of the screw position of 2.8 mm was determined from pilot measurements, and a 1 mm of screw—pedicle edge distance was considered as a difference of interest (standardised difference of 0.35) leading to a power of the study of 75 % (significance level 0.05). Correct placement and stimulation thresholds above 10 mA were found in 71 % of screws. Twenty-two percent of screws caused cortical breach, 80 % of these had stimulation thresholds above 10 mA (sensitivity 20 %, specificity 90 %). True prediction of correct position of the screw was more frequent for lumbar than for thoracic screws. A screw stimulation threshold of >10 mA does not indicate correct pedicle screw placement. A hypothesised gradual decrease of screw stimulation thresholds was not observed as screw placement approaches the nerve root. Aside from a robust threshold of 2 mA indicating direct contact with nervous tissue, a secondary threshold appears to depend on patients’ pathology and surgical conditions.
- 1 April 2012
- Vol. 78 (2) , 240-5
Pedicle screw insertion: robotic assistance versus conventional C-arm fluoroscopy.
Bone-mounted robotic guidance for pedicle screw placement has been recently introduced, aiming at increasing accuracy. The aim of this prospective study was to compare this novel approach with the conventional fluoroscopy assisted freehand technique (not the two- or three-dimensional fluoroscopy-based navigation). Two groups were compared: 11 patients, constituting the robotical group, were instrumented with 64 pedicle screws; 23 other patients, constituting the fluoroscopic group, were also instrumented with 64 pedicle screws. Screw position was assessed by two independent observers on postoperative CT-scans using the Rampersaud A to D classification. No neurological complications were noted. Grade A (totally within pedicle margins) accounted for 79% of the screws in the robotically assisted and for 83% of the screws in the fluoroscopic group respectively (p = 0.8). Grade C and D screws, considered as misplacements, accounted for 4.7% of all robotically inserted screws and 7.8% of the fluoroscopically inserted screws (p = 0.71). The current study did not allow to state that robotically assisted screw placement supersedes the conventional fluoroscopy assisted technique, although the literature is more optimistic about the former.
- 1 April 2012
- Vol. 78 (2) , 240-5
Pedicle screw insertion: robotic assistance versus conventional C-arm fluoroscopy.
Bone-mounted robotic guidance for pedicle screw placement has been recently introduced, aiming at increasing accuracy. The aim of this prospective study was to compare this novel approach with the conventional fluoroscopy assisted freehand technique (not the two- or three-dimensional fluoroscopy-based navigation). Two groups were compared: 11 patients, constituting the robotical group, were instrumented with 64 pedicle screws; 23 other patients, constituting the fluoroscopic group, were also instrumented with 64 pedicle screws. Screw position was assessed by two independent observers on postoperative CT-scans using the Rampersaud A to D classification. No neurological complications were noted. Grade A (totally within pedicle margins) accounted for 79% of the screws in the robotically assisted and for 83% of the screws in the fluoroscopic group respectively (p = 0.8). Grade C and D screws, considered as misplacements, accounted for 4.7% of all robotically inserted screws and 7.8% of the fluoroscopically inserted screws (p = 0.71). The current study did not allow to state that robotically assisted screw placement supersedes the conventional fluoroscopy assisted technique, although the literature is more optimistic about the former.