Chun Ku Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Chun Ku Lee has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Jin Bae Park
Department of Electrical and Electronic Engineering, Yonsei University, Seoul 03722, Korea
3 shared publications - Tae Sung Yoon
Department of Electrical Engineering Changwon National University 20 Changwondaehak‐ro Uichang‐gu Changwon‐si Kyongnam 51140 Republic of Korea
2 shared publications Jong Min Jeong
1 shared publication- Seung Jin Chang
School of Energy Systems Engineering, Chung-Ang University, Seoul, South Korea
1 shared publication Sin Ho Lee
Department of Electrical and Electronic Engineering, Yonsei University, Seoul, Korea
1 shared publicationTae Sung Yoon
Department of Electrical Engineering, Changwon National University, Changwon, Korea
1 shared publication
Latest Publications
- 17 September 2013
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 24 (10) , 105012
Non-invasive monitoring of underground power cables using Gaussian-enveloped chirp reflectometry
In this paper, we introduce non-invasive Gaussian-enveloped linear chirp (GELC) reflectometry for the diagnosis of live underground power cables. The GELC reflectometry system transmits the incident signal to live underground power cables via an inductive coupler. To improve the spatial resolution of the GELC reflectometry, we used the multiple signal classification method, which is a super-resolution method. An equalizer, which is based on Wiener filtering, is used to compensate for the signal distortion due to the propagation characteristics of underground power cables and inductive couplers. The proposed method makes it possible to detect impedance discontinuities in live underground power cables with high spatial resolution. Experiments to find the impedance discontinuity in a live underground power cable were conducted to verify the performance of the proposed method.
- 17 September 2013
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 24 (10) , 105012
Non-invasive monitoring of underground power cables using Gaussian-enveloped chirp reflectometry
In this paper, we introduce non-invasive Gaussian-enveloped linear chirp (GELC) reflectometry for the diagnosis of live underground power cables. The GELC reflectometry system transmits the incident signal to live underground power cables via an inductive coupler. To improve the spatial resolution of the GELC reflectometry, we used the multiple signal classification method, which is a super-resolution method. An equalizer, which is based on Wiener filtering, is used to compensate for the signal distortion due to the propagation characteristics of underground power cables and inductive couplers. The proposed method makes it possible to detect impedance discontinuities in live underground power cables with high spatial resolution. Experiments to find the impedance discontinuity in a live underground power cable were conducted to verify the performance of the proposed method.
- Open Access
- 1 February 2013
- Published by The Korean Institute of Electrical Engineers in The Transactions of The Korean Institute of Electrical Engineers
- Vol. 62 (2) , 239-245
Localization of Concentric Neutrals Corrosion on Live Underground Power Cable Based on Time-frequency Domain Reflectometry
- 1 February 2013
- Published by The Korean Institute of Electrical Engineers in The Transactions of The Korean Institute of Electrical Engineers
- Vol. 62 (2) , 239-245
Open AccessLocalization of Concentric Neutrals Corrosion on Live Underground Power Cable Based on Time-frequency Domain Reflectometry