Maria Bateli
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Maria Bateli has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Wael Att
Department of Prosthodontics, School of Dentistry, Albert-Ludwigs University, Hugstetter Strasse 55, 79106, Freiburg, Germany
2 shared publicationsJörg R Strub
1 shared publicationJörg R. Strub
Department of Prosthodontics, School of Dentistry, Albert-Ludwigs University, Hugstetter Strasse 55, 79106, Freiburg, Germany
1 shared publication- Martin Wolkewitz
Institute of Medical Biometry and Statistics, Faculty of Medicine and Medical Center, University of Freiburg, 79104 Freiburg, Germany
1 shared publication - Matthias Kern
Department of Prosthodontics Christian Albrecht University of Kiel University Hospital Schleswig‐Holstein Campus Kiel Kiel Germany
1 shared publication - Wael Att
Department of Prosthodontics, University Hospital of Freiburg, Freiburg, Germany
1 shared publication
Latest Publications
- 31 July 2013
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 18 (4) , 1181-1187
A retrospective evaluation of teeth restored with zirconia ceramic posts: 10-year results
Zirconia posts can be used as an esthetic alternative to metal posts. Despite their advantages, there is a lack of information about the long-term performance of zirconia posts.
- 31 July 2013
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 18 (4) , 1181-1187
A retrospective evaluation of teeth restored with zirconia ceramic posts: 10-year results
Zirconia posts can be used as an esthetic alternative to metal posts. Despite their advantages, there is a lack of information about the long-term performance of zirconia posts.
- 1 March 2012
- Vol. 43 (3) , 191-5
Tilted implants to support a maxillary removable dental prosthesis: a case report.
The placement of implants in a tilted position may provide a viable treatment modality, especially for patients with atrophic maxillae. The treatment steps and procedures for a maxillary implant-supported removable dental prosthesis, as well as a mandibular telescopic crown-retained removable dental prosthesis, are described. The concept of tilted implants via 3D planning and flapless surgery is presented. The final outcome facilitated improvement in the patient's satisfaction and comfort, as well as long-term stability of the implants and prosthesis. In addition, there was a reduction in cost by avoiding augmentation procedures.
- 1 March 2012
- Vol. 43 (3) , 191-5
Tilted implants to support a maxillary removable dental prosthesis: a case report.
The placement of implants in a tilted position may provide a viable treatment modality, especially for patients with atrophic maxillae. The treatment steps and procedures for a maxillary implant-supported removable dental prosthesis, as well as a mandibular telescopic crown-retained removable dental prosthesis, are described. The concept of tilted implants via 3D planning and flapless surgery is presented. The final outcome facilitated improvement in the patient's satisfaction and comfort, as well as long-term stability of the implants and prosthesis. In addition, there was a reduction in cost by avoiding augmentation procedures.
- 13 April 2011
- Vol. 26 (2) , 290-303
Implant neck configurations for preservation of marginal bone level: a systematic review.
The aim of this article was to evaluate the effectiveness of various implant neck configurations in the preservation of marginal bone level as well as to identify the available scientific evidence. Online and hand searches of the literature published from 1976 through 2009 were conducted to identify studies dealing with modifications in the implant neck area and marginal bone loss for at least a 5-year observation period. The search terms that were used, alone or in combination, were "implant neck," "marginal bone loss," "neck design," "bone resorption," "bone remodeling," and "implant collar." Relevant studies were selected according to predetermined inclusion and exclusion criteria. The initial search yielded 3,517 relevant titles and revealed eight different implant neck configurations and/or methods suggested for the preservation of marginal bone. These methods included changes in implant neck length and design, implant surface characteristics, implant diameter, and/or insertion depth; the addition of microthreads; the use of one-piece implants; and the concept of platform switching. After subsequent filtering, 20 studies were finally selected and involved the following methods: the use of microthreads (1 study); modifications in implant surface characteristics (11 studies), implant diameter (4 studies), or insertion depth (2 studies); the use of one-piece implants (3 studies); and platform switching (1 study). Because of the heterogeneity of the studies, it was not possible to analyze the data statistically. No evidence was found regarding the effectiveness of any specific modification in the implant neck area in preserving marginal bone or preventing marginal bone loss. The current literature provides insufficient evidence about the effectiveness of different implant neck configurations in the preservation of marginal bone. Long-term randomized controlled clinical trials are needed to elucidate the effects of such modifications.
- 13 April 2011
- Vol. 26 (2) , 290-303
Implant neck configurations for preservation of marginal bone level: a systematic review.
The aim of this article was to evaluate the effectiveness of various implant neck configurations in the preservation of marginal bone level as well as to identify the available scientific evidence. Online and hand searches of the literature published from 1976 through 2009 were conducted to identify studies dealing with modifications in the implant neck area and marginal bone loss for at least a 5-year observation period. The search terms that were used, alone or in combination, were "implant neck," "marginal bone loss," "neck design," "bone resorption," "bone remodeling," and "implant collar." Relevant studies were selected according to predetermined inclusion and exclusion criteria. The initial search yielded 3,517 relevant titles and revealed eight different implant neck configurations and/or methods suggested for the preservation of marginal bone. These methods included changes in implant neck length and design, implant surface characteristics, implant diameter, and/or insertion depth; the addition of microthreads; the use of one-piece implants; and the concept of platform switching. After subsequent filtering, 20 studies were finally selected and involved the following methods: the use of microthreads (1 study); modifications in implant surface characteristics (11 studies), implant diameter (4 studies), or insertion depth (2 studies); the use of one-piece implants (3 studies); and platform switching (1 study). Because of the heterogeneity of the studies, it was not possible to analyze the data statistically. No evidence was found regarding the effectiveness of any specific modification in the implant neck area in preserving marginal bone or preventing marginal bone loss. The current literature provides insufficient evidence about the effectiveness of different implant neck configurations in the preservation of marginal bone. Long-term randomized controlled clinical trials are needed to elucidate the effects of such modifications.