GKGeun-Beom Kim

Geun-Beom Kim

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Geun-Beom Kim has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Development of a Real-Time Pixel Array-Type Detector for Ultrahigh Dose-Rate Beams

    by Young Jae Jang, Tae Keun Yang, Jeong Hwan Kim, Hong Suk Jang, Jong Hwi Jeong, Kum Bae Kim, Geun-Beom Kim, Seong Hee Park, Sang Hyoun Choi

    Although research into ultrahigh dose-rate (UHDR) radiation therapy is ongoing, there is a significant lack of experimental measurements for two-dimensional (2D) dose-rate distributions. Additionally, conventional pixel-type detectors result in significant beam loss. In this study, we developed a pixel array-type detector with adjustable gaps and a data acquisition system to evaluate its effectiveness in measuring UHDR proton beams in real time. We measured a UHDR beam at the Korea Institute of Radiological and Medical Sciences using an MC-50 cyclotron, which produced a 45-MeV energy beam with a current range of 10–70 nA, to confirm the UHDR beam conditions. To minimize beam loss during measurement, we adjusted the gap and high voltage on the detector and determined the collection efficiency of the developed detector through Monte Carlo simulation and experimental measurements of the 2D dose-rate distribution. We also verified the accuracy of the real-time position measurement using the developed detector with a 226.29-MeV PBS beam at the National Cancer Center of the Republic of Korea. Our results indicate that, for a current of 70 nA with an energy beam of 45 MeV generated using the MC-50 cyclotron, the dose rate exceeded 300 Gy/s at the center of the beam, indicating UHDR conditions. Simulation and experimental measurements show that fixing the gap at 2 mm and the high voltage at 1000 V resulted in a less than 1% loss of collection efficiency when measuring UHDR beams. Furthermore, we achieved real-time measurements of the beam position with an accuracy of within 2% at five reference points. In conclusion, our study developed a beam monitoring system that can measure UHDR proton beams and confirmed the accuracy of the beam position and profile through real-time data transmission.


  • Design of the KHIMA synchrotron

    by Heejoong Yim, Dong Hyun An, Garam Hahn, Chawon Park, Geun-Beom Kim


  • Development of a control system for the 14.5 GHz ECR ion source

    by Jeong-Hwan Kim, Won-Taek Hwang, Dong-Wook Park, Hong-Suk Chang, Tae-Keun Yang, Kun-Uk Kang, Se-Duk Chang, Chang-Hyeuk Kim, Hwa-Ryun Lee, Hyun-Yong Kim, et al.

    A control system of the 14.5 GHz electron cyclotron resonance (ECR) ion source has been designed and developed in KHIMA(Korea Heavy Ion Medical Accelerator) project which will use C6+ ions for heavy ion therapy. Production of the selected ion beam in stable operation with safety is a development goal with flexibility by easy access and modification which are necessary during development process with an accelerator. The control system of the ECR ion source system consists of electric control cabinet (ECC) as hardware and main control program (MCP) as software, respectively. ECC developed to manage power and control flow with electric components and controllers controls the injection system, RF system, high voltage & extraction system, analyzing system, vacuum system, cooling system, diagnosis system and safety system. MCP is the supervisory program developed for effective automation and data acquisition by LabVIEW-based graphical programming. The isolated network from a control computer to ECC and bleeder resistors in a steel plate box composed by the simulation result for high voltage power supplies increase reliability and safety. The performance of the developed control system has been verified successfully by beam extraction of C4+ ion from CO2 as main gas and He as support gas through an analyzing magnet and a faraday cup with the acquired spectrum at the control system. After optimization with C4+ ions, measurement of characteristics of C6+ ions including emittance of the ion beam will be planned early 2013. Also, quantity of C6+ ions in the same charge to mass ratio will be estimated by using 13CO2 as main gas and He as support gas.