MAMehmet Dogan Asik

Mehmet Dogan Asik

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Mehmet Dogan Asik has a total of 111 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Mechanotyping of Organoids for Assessing Drug‐Induced Injuries

    by Murat Kaynak, Mehmet D. Aşık, Elif E. Inan, Maksymilian Prondzynski, Hamzeh Ghasemzadeh, Amir Poorghani, Yashasvi Tharani, Matilda Holtz, Daryush D. Mehta, William T. Pu, et al.

    Changes in the mechanical properties, i.e., mechanotypes, of tissues are powerful indicators of disease states and drug‐induced injuries. Although differential mechanotyping has emerged as a valuable tool for non‐invasive disease diagnostics, it remains particularly underutilized for drug safety and efficacy screening in preclinical studies. This is largely due to the lack of scalable mechanotyping methods compatible with modern 3D organoid models. Here, the Centrifugal Mechanical Testing (CeMeT) platform is presented, which enables rapid, robust, and label‐free mechanotyping of 3D organoids. Utilizing centrifugal mechanical principles and high‐speed imaging, this platform achieves high accuracy and precision and can assess a wide range of tissue stiffness. It is demonstrated that the CeMeT platform distinguishes mechanical properties, i.e., stiffness and elastic recovery, among various hydrogel bead formulations and hiPSC‐derived cardiac organoids, successfully detecting pathological changes in mechanotype with high sensitivity. Through experiments on organoids treated with drugs like pergolide and Cytochalasin‐D, it is established that changes in organoid mechanotypes can serve as reliable indicators of drug‐induced tissue injuries in vitro. These findings position the CeMeT platform as a potentially transformative tool for early‐stage drug safety assessment through mechanotyping, with immediate applications extending to fundamental disease pathology research and drug efficacy testing using organoid models.

  • Advancing Joint Infection Treatment: Long‐Term Animal Implantation of Submicron Gentamicin‐Loaded UHMWPE

    by Mehmet D. Asik, Timothy Zhao, Yingfang Fan, Matheus Ferreira, Lu Yang, Nicoletta Inverardi, Amita Sekar, Keita Fujino, Fawaz Ben Malick, Keith K. Wannomae, et al.

    Periprosthetic joint infection (PJI) is a devastating complication of total joint arthroplasty, often necessitating two‐stage revision surgery with antibiotic‐loaded bone cement (ALBC) spacers, which cannot maintain therapeutic local antibiotic concentrations over time. This study evaluated the long‐term stability, antimicrobial efficacy, and biocompatibility of an alternative material, submicron gentamicin sulfate‐loaded ultrahigh molecular weight polyethylene (SM‐GS/UHMWPE), in vitro and in vivo by using a subcutaneous rat model. SM‐GS/UHMWPE implants containing 6 wt% and 10 wt% gentamicin sulfate (GS) were fabricated and tested in vitro and simultaneously in vivo by subcutaneous implantation in rats for 4, 8, and 26 weeks. Gentamicin stability was assessed using nuclear magnetic resonance (NMR) spectroscopy and liquid chromatography‐mass spectrometry (LC–MS/MS). Antimicrobial efficacy against Staphylococcus aureus was determined via bacterial culture assays. Mechanical integrity was evaluated using tensile testing in vitro. Systemic toxicity was assessed through liver and kidney function markers, and histological analysis of kidney and skin tissues was performed. NMR and LC–MS/MS confirmed that gentamicin remained chemically stable over 26 weeks in vivo and in vitro. Antimicrobial testing showed sustained bacterial inhibition, with implants containing 10% GS achieving a 3.5‐log reduction in bacterial counts for 6 months. Mechanical testing demonstrated minimal changes in tensile properties over time. Serum biochemical markers remained within normal ranges, and histological evaluation showed no significant inflammation or tissue damage. Gentamicin elution profiles indicated sustained release, maintaining intraarticular levels above 100 times the minimum inhibitory concentration (MIC) of S. aureus for 6 months. SM‐GS/UHMWPE implants demonstrated prolonged antibiotic release while maintaining mechanical integrity, antimicrobial efficacy, and biocompatibility. These findings support the potential use of SM‐GS/UHMWPE as a next‐generation antibiotic‐eluting spacer for PJI treatment, offering an alternative to ALBC for sustained drug release and reduced systemic toxicity risks.


  • In Vitro Characterization and In Vivo Performance of Vancomycin‐Loaded PLGA Microspheres Prepared by Using Microfluidics for the Management of Orthopedic Infections

    by Dinesh Dhamecha, Mehmet D. Asik, Cecilia Nepple, Yingfang Fan, Amita Sekar, Keita Fujino, Fawaz Malick, Madeline McCanne, Ebru Oral, Orhun Muratoglu

    Periprosthetic joint infection (PJI) is a severe complication of total joint arthroplasty (TJA), leading to high rates of revision surgeries, long‐term morbidity, and mortality. Conventional antibiotic treatments often suffer from limited bioavailability and systemic toxicity. This study explores a novel approach using vancomycin‐loaded poly(lactic‐co‐glycolic) acid (PLGA) microparticles (VMP) formulated via a microfluidic double emulsion method for controlled, localized drug delivery for managing PJI. The PLGA microparticles were synthesized to achieve high loading capacity and sustained vancomycin release, aiming to maintain therapeutic intra‐articular concentrations. In vitro characterization demonstrated optimal loading capacity (up to 28% w/w), morphology with a homogeneous particle size distribution (49–65 µm), and sustained release profiles over 8 weeks. In vivo efficacy was evaluated using a rat joint infection model, showing significant reductions in bacterial viability and enhanced bone healing compared to controls. Weight‐bearing recovery assessments showed that VMP‐treated rats regained functionality significantly earlier than controls (p < 0.05). Radiographic, histological, and immunofluorescent analyses confirmed reduced inflammation and improved bone integrity with VMP treatment. These findings suggest that microfluidic‐synthesized PLGA microparticles provide a promising strategy for localized, controlled release of antibiotics, potentially helping the management of PJI and improving postsurgical outcomes. Future research should explore the long‐term effects and scalability of clinical applications. This study lays the foundation for advancing controlled release systems in orthopedic postoperative care.


  • Enhanced Antibiotic Release and Mechanical Strength in UHMWPE Antibiotic Blends

    by Mehmet D. Asik, Eileen Walsh-Rock, Nicoletta Inverardi, Cecilia Nepple, Timothy Zhao, Amita Sekar, Devika Dutta Kannambadi, Matheus Ferreira, Keith K. Wannomae, Ebru Oral, et al.

    Background: Periprosthetic joint infections (PJIs) are a major complication of total joint replacement surgeries. This study investigated the enhancement of mechanical properties and antibiotic release in ultra-high molecular weight polyethylene (UHMWPE) through the encapsulation of submicron gentamicin sulfate (GS) particles, addressing the critical need for improved implant materials in orthopaedic surgery, particularly in managing PJIs. Methods: The present study involved embedding submicron GS particles into UHMWPE flakes at concentrations of 2% to 10% by weight. These particles were prepared and blended with UHMWPE flakes using a dual asymmetric centrifugal mixer, and the blends were consolidated. The present study compared the mechanical properties and antibiotic release rate of UHMWPE containing submicron, medium (as-received), and large (resolidified) GS particles. Results: UHMWPE samples with submicron GS particles exhibited superior mechanical properties, including higher ultimate tensile and Izod impact strengths, compared with samples with larger particles. Additionally, the submicron GS UHMWPE blends demonstrated a markedly higher and more sustained antibiotic release rate. Conclusions: This study highlights the potential of incorporating submicron GS particles into UHMWPE to drastically improve the feasibility of using these therapeutic and functional spacer implants in expanded indications. Clinical Relevance: By offering improved mechanical strength and effective, prolonged antibiotic release, this innovative material could be used as a spacer implant to reduce the considerably high morbidity and mortality associated with PJIs. This material has the potential to prevent PJIs not only in high-risk revision cases but also in primary total joint arthroplasty procedures.


  • Open Access

    The efficacy of vitamin E in preventing arthrofibrosis after joint replacement

    by Yingfang Fan, Jean Yuh, Sashank Lekkala, Mehmet D. Asik, Andrew Thomson, Madeline McCanne, Mark A. Randolph, Antonia F. Chen, Ebru Oral

    Background: Arthrofibrosis is a joint disorder characterized by excessive scar formation in the joint tissues. Vitamin E is an antioxidant with potential anti‐fibroblastic effect. The aim of this study was to establish an arthrofibrosis rat model after joint replacement and assess the effects of vitamin E supplementation on joint fibrosis.Methods: We simulated knee replacement in 16 male Sprague–Dawley rats. We immobilized the surgical leg with a suture in full flexion. The control groups were killed at 2 and 12 weeks (n = 5 per group), and the test group was supplemented daily with vitamin E (0.2 mg/mL) in their drinking water for 12 weeks (n = 6). We performed histological staining to investigate the presence and severity of arthrofibrosis. Immunofluorescent staining and α2‐macroglobulin (α2M) enzyme‐linked immunosorbent assay (ELISA) were used to assess local and systemic inflammation. Static weight bearing (total internal reflection) and range of motion (ROM) were collected for functional assessment.Results: The ROM and weight‐bearing symmetry decreased after the procedure and recovered slowly with still significant deficit at the end of the study for both groups. Histological analysis confirmed fibrosis in both lateral and posterior periarticular tissue. Vitamin E supplementation showed a moderate anti‐inflammatory effect on the local and systemic levels. The vitamin E group exhibited significant improvement in ROM and weight‐bearing symmetry at day 84 compared to the control group.Conclusions: This model is viable for simulating arthrofibrosis after joint replacement. Vitamin E may benefit postsurgical arthrofibrosis, and further studies are needed for dosing requirements.


  • The Co-Use of Stromal Vascular Fraction and Bone Marrow Concentrate for Tendon Healing

    by Emin Yusuf Aydın, Mehmet Aşık, Halil Murat Aydın, Nurdan Çay, Berrak Gümüşkaya, Ayça Çağlayan, Ali Torabi, Sümeyye Yüksel, Enejd Veizi, Murat Bozkurt

    Objective: The Achilles tendon is the most frequently injured tendon in the human body, despite being the strongest. Many conventional treatments including medication, surgical interventions, and physical therapy are available, however, the desired results are often not achieved. Stromal vascular fraction (SVF) and bone marrow concentrate (BMC) are two additional cellular treatment options. The purpose of this study is to evaluate the effect of SVF and BMC, used as a combination, for the treatment of Achilles tendon injuries. Design: Five male New Zealand rabbits were used for each of the 6 study groups. A 3-mm of SVF and BMC were injected on the Achilles tendons at certain ratios. The histological results were classified by the Movin grading system for tendon healing. The collagen type-I and type-III structures in the tendons were examined by immunohistochemical evaluation. The expressions of tendon-specific genes were also examined by using the RT-PCR method to analyze tendon healing. Results: Histological and immunohistochemical evaluation indicated that tendons receiving the SVF and BMAC mixture performed better than control and individual groups (p<0.05). Moreover, RT-PCR evaluation showed that mixture-receiving groups were the closest similar to the uninjured group (p<0.05). Conclusion: The combined use of BMC and SVF improved Achilles tendon healing when compared to the individual use of each mixture.


  • Fabrication of a multi-layered decellularized amniotic membranes as tissue engineering constructs

    by Sümeyye Yüksel, Mehmet Doğan Aşık, Halil Murat Aydin, Ergin Tönük, Emin Yusuf Aydın, Murat Bozkurt


  • Open Access

    Proksimal tibia medial açık kama osteotomisi: Spacer plak ile tespit

    by Mehmet Aşık, Gökhan Polat, Taha Kızılkurt

  • Development of a Sequential Antibiotic Releasing System for Two-Stage Total Joint Replacement Surgery

    by Mehmet Dogan Aşık, Mesut Kaplan, Meltem Yalınay, Eylem Öztürk Güven, Murat Bozkurt

    In recent years, there has been an increase in nanoparticle research towards creating better release systems that can maintains the effective dosage over desired periods. Conventional nanoparticle systems have not been successful for this goal. Thus, the aim of this study is to evaluate the sequential release profiles of hybrid materials, combining nanoparticles, hydrogels and bone cement, for the treatment of arthroplasty infections. In this study, Vancomycin, which is one of the most used antibiotics in orthopedics, was loaded to alginate–chitosan nanoparticles. These drug-loaded nanoparticles were dispersed in an alginate gel and the gel covered the polymethylmethacrylate bone cement. After the crosslinking of the gel around the bone cement, the sequential release profile was evaluated for 60 days in vitro. The results of the morphological, chemical characterization and encapsulations studies showed that different loadings of drugs resulted in different encapsulation efficiencies. Although the release profile from the nanoparticles was as expected, the sequential release profile of the combined system has a Fickian type release for a longer time period. In conclusion, the results indicate that combining different release systems can alter the release profile of the system.