Gilad Arwatz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Gilad Arwatz has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
A.J. Smits
Department of Mechanical and Aerospace Engineering, Princeton University, Princeton, NJ, USA
1 shared publicationAlexander J Smits
1 shared publicationCarla Bahri
1 shared publicationMarcus Hultmark
1 shared publication
Latest Publications
- 22 October 2013
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 24 (12) , 125301
Dynamic calibration and modeling of a cold wire for temperature measurement
The dynamical behavior of cold wires and their supporting structure is investigated. It is shown that conventional cold wires have a much more limited frequency response than previously believed, which can cause substantial inaccuracies in temperature data. Here, a lumped parameter model that accounts for the effects of end conduction and wire response is developed. The model is verified by comparing to the experimental data, where the frequency response of the wire is investigated under different heating conditions, with convincing agreement. All the parameters in the model can be found from the geometry of the sensor and the properties of the materials used in its construction. The new model can either be used as a sensor design and optimization tool, in order to design better sensors, or it can be used to correct the data acquired with conventional cold wire sensors, with non-negligible end-conduction effects, so that accurate measurements can be obtained.
- 22 October 2013
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 24 (12) , 125301
Dynamic calibration and modeling of a cold wire for temperature measurement
The dynamical behavior of cold wires and their supporting structure is investigated. It is shown that conventional cold wires have a much more limited frequency response than previously believed, which can cause substantial inaccuracies in temperature data. Here, a lumped parameter model that accounts for the effects of end conduction and wire response is developed. The model is verified by comparing to the experimental data, where the frequency response of the wire is investigated under different heating conditions, with convincing agreement. All the parameters in the model can be found from the geometry of the sensor and the properties of the materials used in its construction. The new model can either be used as a sensor design and optimization tool, in order to design better sensors, or it can be used to correct the data acquired with conventional cold wire sensors, with non-negligible end-conduction effects, so that accurate measurements can be obtained.
- Open Access
- 1 January 2013
- Published by SAGE Publications in Biorheology
- Vol. 50 (1-2) , 45-55
A viscoelastic model of shear-induced hemolysis in laminar flow
We present measurements of human blood hemolysis caused by laminar shear stresses ranging from 50 to 500 Pa for exposure times extending from 60 to 300 s using a Taylor-Couette device. A viscoelastic model is proposed that captures the response of the red blood cells to shear stress. The model is based on well-established mechanical properties of the red blood cell membrane, and shows good agreement with data from the experiments presented here, as well as data from the existing literature. Two characteristic time scales are identified: a fast time scale corresponding to the relaxation time of the red blood cell membrane and a slow time scale that represents the onset of plasticity and is related to hemoglobin release from a damaged cell. The model proposed here collapses the available data over almost five orders of magnitude in exposure time and shear stresses up to 500 Pa.
- 1 January 2013
- Published by SAGE Publications in Biorheology
- Vol. 50 (1-2) , 45-55
Open AccessA viscoelastic model of shear-induced hemolysis in laminar flow
We present measurements of human blood hemolysis caused by laminar shear stresses ranging from 50 to 500 Pa for exposure times extending from 60 to 300 s using a Taylor-Couette device. A viscoelastic model is proposed that captures the response of the red blood cells to shear stress. The model is based on well-established mechanical properties of the red blood cell membrane, and shows good agreement with data from the experiments presented here, as well as data from the existing literature. Two characteristic time scales are identified: a fast time scale corresponding to the relaxation time of the red blood cell membrane and a slow time scale that represents the onset of plasticity and is related to hemoglobin release from a damaged cell. The model proposed here collapses the available data over almost five orders of magnitude in exposure time and shear stresses up to 500 Pa.