Anna Stolarz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Anna Stolarz has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
- Katarzyna Szkliniarz
August Chełkowski Institute of Physics, University of Silesia in Katowice, 75 Pułku Piechoty 1, 41-500 Chorzów, Poland
4 shared publications - Agnieszka Trzcinska
University of Warsaw
2 shared publications J. A. Kowalska
Heavy Ion laboratory, University of Warsaw, 02-093 Warszawa, Poland
2 shared publicationsA. Kordyasz
Heavy Ion Laboratory, University of Warsaw, ul. Pasteura 5a, 02-093 Warsaw, Poland
1 shared publicationAdam T. Rudchik
1 shared publicationAgata Piotrowska
Institute of Nuclear Chemistry and Technology, Dorodna 16, 03-195 Warsaw, Poland
1 shared publication
Latest Publications
- Open Access
- 28 February 2020
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 229, 06004
Calcium targets for production of the medical Sc radioisotopes in reactions with p, d or α projectiles
The scandium radioisotopes for medical application can be produced in reactions of calcium with proton, deuteron or alpha projectiles. Enriched isotopic calcium material is commercially available mainly as calcium carbonate which can be used directly for production of Sc radioisotopes or can be converted into other calcium compounds or into metallic form. The superiority of application of calcium oxide is shown throughout analysis of use of each target chemical form.
- 28 February 2020
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 229, 06004
Open AccessCalcium targets for production of the medical Sc radioisotopes in reactions with p, d or α projectiles
The scandium radioisotopes for medical application can be produced in reactions of calcium with proton, deuteron or alpha projectiles. Enriched isotopic calcium material is commercially available mainly as calcium carbonate which can be used directly for production of Sc radioisotopes or can be converted into other calcium compounds or into metallic form. The superiority of application of calcium oxide is shown throughout analysis of use of each target chemical form.
- Open Access
Separation of 44Sc from Natural Calcium Carbonate Targets for Synthesis of 44Sc-DOTATATE
The rapid increase in applications of scandium isotopes in nuclear medicine requires new efficient production routes for these radioisotopes. Recently, irradiations of calcium in cyclotrons by α, deuteron, and proton beams have been used. Therefore, effective post-irradiation separation and preconcentration of the radioactive scandium from the calcium matrix are important to obtain the pure final product in a relatively small volume. Nobias resin was used as a sorbent for effective separation of 44Sc from calcium targets. Separation was performed at pH 3 using a column containing 10 mg of resin. Scandium was eluted with 100 μL of 2 mol L−1 HCl. Particular attention was paid to the reduction of calcium concentration, presence of metallic impurities, robustness and simple automation. 44Sc was separated with 94.9 ± 2.8% yield, with results in the range of 91.7–99.0%. Purity of the eluate was confirmed with ICP-OES determination of metallic impurities and >99% chelation efficiency with DOTATATE, followed by >36 h radiochemical stability of the complex. A wide range of optimal conditions and robustness to target variability and suspended matter facilitates the proposed method in automatic systems for scandium isotope separation and synthesis of scandium-labeled radiopharmaceuticals.
Open AccessSeparation of 44Sc from Natural Calcium Carbonate Targets for Synthesis of 44Sc-DOTATATE
The rapid increase in applications of scandium isotopes in nuclear medicine requires new efficient production routes for these radioisotopes. Recently, irradiations of calcium in cyclotrons by α, deuteron, and proton beams have been used. Therefore, effective post-irradiation separation and preconcentration of the radioactive scandium from the calcium matrix are important to obtain the pure final product in a relatively small volume. Nobias resin was used as a sorbent for effective separation of 44Sc from calcium targets. Separation was performed at pH 3 using a column containing 10 mg of resin. Scandium was eluted with 100 μL of 2 mol L−1 HCl. Particular attention was paid to the reduction of calcium concentration, presence of metallic impurities, robustness and simple automation. 44Sc was separated with 94.9 ± 2.8% yield, with results in the range of 91.7–99.0%. Purity of the eluate was confirmed with ICP-OES determination of metallic impurities and >99% chelation efficiency with DOTATATE, followed by >36 h radiochemical stability of the complex. A wide range of optimal conditions and robustness to target variability and suspended matter facilitates the proposed method in automatic systems for scandium isotope separation and synthesis of scandium-labeled radiopharmaceuticals.
- 1 January 2018
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1962 (1) , 020004
Targets for production of the medical radioisotopes with alpha and proton or deuteron beams
The research quantities of some medical radioisotopes were produced in reactions induced by 32 MeV internal alpha beam (211At, Sc isotopes), 16 MeV and 28 MeV proton beams (Sc isotopes) and 8 MeV deuteron beam (Sc isotopes). The frame-less targets used for irradiation with internal alpha beam were prepared from elemental (Bi for 211At) and compound (CaCO3 for Sc radioisotopes) materials. The CaCO3 powder targets were also used for production of Sc radioisotopes with proton or deuteron external beams. Methods developed for preparation of the targets suitable for the irradiating beam type are described in this work.
- 1 January 2018
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1962 (1) , 020004
Targets for production of the medical radioisotopes with alpha and proton or deuteron beams
The research quantities of some medical radioisotopes were produced in reactions induced by 32 MeV internal alpha beam (211At, Sc isotopes), 16 MeV and 28 MeV proton beams (Sc isotopes) and 8 MeV deuteron beam (Sc isotopes). The frame-less targets used for irradiation with internal alpha beam were prepared from elemental (Bi for 211At) and compound (CaCO3 for Sc radioisotopes) materials. The CaCO3 powder targets were also used for production of Sc radioisotopes with proton or deuteron external beams. Methods developed for preparation of the targets suitable for the irradiating beam type are described in this work.
- 23 December 2015
- Published by Walter de Gruyter GmbH in Radiochimica Acta
- Vol. 104 (4) , 267-275
Silver impregnated nanoparticles of titanium dioxide as carriers for 211At
The 211At radioisotope exhibits very attractive nuclear properties for application in radionuclide therapy. Unfortunately use of 211At is limited, because astatine as the heaviest halogen forms weak bond with carbon atoms in the biomolecules which makes 211At bioconjugates unstable in physiological conditions. In our work we propose a new solution for binding of 211At which consists of using nanoparticles of titanium dioxide modified with silver atoms as carriers for 211At. Ag+ cations have been absorbed on the nanometer-sized TiO2 particles (15 and 32 nm) through ion exchange process and were reduced in Tollens' reaction. The obtained TiO2-Ag nanoparticles were labeled with 211At. It was found that labeling yields were almost quantitative under reducing conditions, while under oxidizing conditions they dropped to about 80%. The labeled nanoparticles exhibited very high stability in physiological salt, PBS buffer, solutions of peptides (0.001 M cysteine, 0.001 M glutathione) and in human blood serum. To make TiO2/Ag nanoparticles well dispersed in water and biocompatible their surface was modified with a silane coupling agent containing poly(ethyleneglycol) molecules. The developed functionalization approach will allow us to attach biomolecules to the TiO2/Ag surface.
- 23 December 2015
- Published by Walter de Gruyter GmbH in Radiochimica Acta
- Vol. 104 (4) , 267-275
Silver impregnated nanoparticles of titanium dioxide as carriers for 211At
The 211At radioisotope exhibits very attractive nuclear properties for application in radionuclide therapy. Unfortunately use of 211At is limited, because astatine as the heaviest halogen forms weak bond with carbon atoms in the biomolecules which makes 211At bioconjugates unstable in physiological conditions. In our work we propose a new solution for binding of 211At which consists of using nanoparticles of titanium dioxide modified with silver atoms as carriers for 211At. Ag+ cations have been absorbed on the nanometer-sized TiO2 particles (15 and 32 nm) through ion exchange process and were reduced in Tollens' reaction. The obtained TiO2-Ag nanoparticles were labeled with 211At. It was found that labeling yields were almost quantitative under reducing conditions, while under oxidizing conditions they dropped to about 80%. The labeled nanoparticles exhibited very high stability in physiological salt, PBS buffer, solutions of peptides (0.001 M cysteine, 0.001 M glutathione) and in human blood serum. To make TiO2/Ag nanoparticles well dispersed in water and biocompatible their surface was modified with a silane coupling agent containing poly(ethyleneglycol) molecules. The developed functionalization approach will allow us to attach biomolecules to the TiO2/Ag surface.
- Open Access
- 15 February 2015
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 305 (3) , 947-952
Molybdenum targets produced by mechanical reshaping
Targets required to determine the parameters of the 100Mo(p,xn)99mTc reaction and to estimate the yield of the 99mTc production were prepared starting with powder material. Material, melted with electron beam gun into solid bead, was reshaped into foil mechanically. Targets were prepared by powder melting and hot flattening of the droplet followed by cold rolling. Procedure allowed preparation of thick (in the range of hundreds of microns) and thin (down to 250 nm) foils.
- 15 February 2015
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 305 (3) , 947-952
Open AccessMolybdenum targets produced by mechanical reshaping
Targets required to determine the parameters of the 100Mo(p,xn)99mTc reaction and to estimate the yield of the 99mTc production were prepared starting with powder material. Material, melted with electron beam gun into solid bead, was reshaped into foil mechanically. Targets were prepared by powder melting and hot flattening of the droplet followed by cold rolling. Procedure allowed preparation of thick (in the range of hundreds of microns) and thin (down to 250 nm) foils.
- 1 February 2014
- Published by Elsevier in Nuclear Physics A
- Vol. 922, 71-83
Elastic and inelastic scattering of 6Li + 18O versus 7Li + 18O and 6Li + 16O
- 1 February 2014
- Published by Elsevier in Nuclear Physics A
- Vol. 922, 71-83
Elastic and inelastic scattering of 6Li + 18O versus 7Li + 18O and 6Li + 16O
- Open Access
- 19 November 2013
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 299 (2) , 913-931
Target preparation for research with charged projectiles
The paper reviews in a compact format the techniques most frequently used for target preparation, such as rolling, powder compacting, and vacuum deposition. The survey covers also the techniques used for target characterisation (thickness, purity) and problems related to the extension of target life-time and time of uninterrupted experiments with use of targets.
- 19 November 2013
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 299 (2) , 913-931
Open AccessTarget preparation for research with charged projectiles
The paper reviews in a compact format the techniques most frequently used for target preparation, such as rolling, powder compacting, and vacuum deposition. The survey covers also the techniques used for target characterisation (thickness, purity) and problems related to the extension of target life-time and time of uninterrupted experiments with use of targets.
- Open Access
- 2 August 2013
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 299 (2) , 1133-1136
Fine plastic foil as backing for sputtered nickel targets
- 2 August 2013
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 299 (2) , 1133-1136
Open AccessFine plastic foil as backing for sputtered nickel targets
- 1 November 2011
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 655 (1) , 100-102
Target set-up for measurements with the use of a Si-ball detector
- 1 November 2011
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 655 (1) , 100-102
Target set-up for measurements with the use of a Si-ball detector
- 1 March 2002
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 480 (1) , 194-198
Large-area thin self-supporting carbon foils with MgO coatings
- 1 March 2002
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 480 (1) , 194-198
Large-area thin self-supporting carbon foils with MgO coatings