Sean W. Linder
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sean W. Linder has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Thilak K. Mudalige
Office of Regulatory Affairs, Arkansas Laboratory, U.S. Food and Drug Administration, 3900 NCTR Road, Jefferson, AR 72079, United States
4 shared publicationsHaiou Qu
U.S. Food and Drug Administration, Office of Regulatory Affairs, Arkansas Regional Laboratory 3900 NCTR Road, Jefferson, AR 72079, United States
3 shared publications- Thilak Mudalige
Arkansas Laboratory, Office of Regulatory Science, Office of Regulatory Affairs, U.S. Food and Drug Administration, Jefferson, AR 72079, United States
3 shared publications Germarie Sánchez-Pomales
†Office of Regulatory Affairs, Arkansas Regional Laboratory, and ‡National Center for Toxicological Research, Office of Scientific Coordination, U.S. Food and Drug Administration, 3900 NCTR Road, Jefferson, Arkansas 72079, United States
2 shared publications- Jin-Hee Lim
Office of Regulatory Affairs, Arkansas Laboratory, U.S. Food and Drug Administration, 3900 NCTR Road, Jefferson, AR, 72079, United States
2 shared publications - Ivan R. Quevedo
Department of Chemical Engineering, McGill University, Montreal, Quebec H3A 2B2, Canada
1 shared publication
Latest Publications
- 1 August 2018
- Published by Elsevier in Journal of Chromatography B
- Vol. 1091, 14-20
Novel analytical methods to assess the chemical and physical properties of liposomes
- 1 August 2018
- Published by Elsevier in Journal of Chromatography B
- Vol. 1091, 14-20
Novel analytical methods to assess the chemical and physical properties of liposomes
- 1 February 2016
- Published by Elsevier in Spectrochimica Acta Part B: Atomic Spectroscopy
- Vol. 116, 21-27
Portable X-ray fluorescence spectroscopy as a rapid screening technique for analysis of TiO2 and ZnO in sunscreens
- 1 February 2016
- Published by Elsevier in Spectrochimica Acta Part B: Atomic Spectroscopy
- Vol. 116, 21-27
Portable X-ray fluorescence spectroscopy as a rapid screening technique for analysis of TiO2 and ZnO in sunscreens
- 19 March 2015
- Published by American Chemical Society (ACS) in Journal of Agricultural and Food Chemistry
- Vol. 63 (12) , 3153-3160
Arsenic Speciation in Rice by Capillary Electrophoresis/Inductively Coupled Plasma Mass Spectrometry: Enzyme-Assisted Water-Phase Microwave Digestion
We report an analytical methodology for the quantification of common arsenic species in rice and rice cereal using capillary electrophoresis coupled with inductively coupled plasma mass spectrometry (CE–ICPMS). An enzyme (i.e., α-amylase)-assisted water-phase microwave extraction procedure was used to extract four common arsenic species, including dimethylarsinic acid (DMA), monomethylarsonic acid (MMA), arsenite [As(III)], and arsenate [As(V)] from the rice matrices. The addition of the enzyme α-amylase during the extraction process was necessary to reduce the sample viscosity, which subsequently increased the injection volume and enhanced the signal response. o-Arsanilic acid (o-ASA) was added to the sample solution as a mobility marker and internal standard. The obtained repeatability [i.e., relative standard deviation (RSD %)] of the four arsenic analytes of interest was less than 1.23% for elution time and 2.91% for peak area. The detection limits were determined to be 0.15–0.27 ng g–1. Rice standard reference materials SRM 1568b and CRM 7503-a were used to validate this method. The quantitative concentrations of each organic arsenic and summed inorganic arsenic were found within 5% difference of the certified values of the two reference materials.
- 19 March 2015
- Published by American Chemical Society (ACS) in Journal of Agricultural and Food Chemistry
- Vol. 63 (12) , 3153-3160
Arsenic Speciation in Rice by Capillary Electrophoresis/Inductively Coupled Plasma Mass Spectrometry: Enzyme-Assisted Water-Phase Microwave Digestion
We report an analytical methodology for the quantification of common arsenic species in rice and rice cereal using capillary electrophoresis coupled with inductively coupled plasma mass spectrometry (CE–ICPMS). An enzyme (i.e., α-amylase)-assisted water-phase microwave extraction procedure was used to extract four common arsenic species, including dimethylarsinic acid (DMA), monomethylarsonic acid (MMA), arsenite [As(III)], and arsenate [As(V)] from the rice matrices. The addition of the enzyme α-amylase during the extraction process was necessary to reduce the sample viscosity, which subsequently increased the injection volume and enhanced the signal response. o-Arsanilic acid (o-ASA) was added to the sample solution as a mobility marker and internal standard. The obtained repeatability [i.e., relative standard deviation (RSD %)] of the four arsenic analytes of interest was less than 1.23% for elution time and 2.91% for peak area. The detection limits were determined to be 0.15–0.27 ng g–1. Rice standard reference materials SRM 1568b and CRM 7503-a were used to validate this method. The quantitative concentrations of each organic arsenic and summed inorganic arsenic were found within 5% difference of the certified values of the two reference materials.
- 18 March 2015
- Published by American Chemical Society (ACS) in Journal of Agricultural and Food Chemistry
- Vol. 63 (12) , 3144-3152
Detection and Characterization of SiO2 and TiO2 Nanostructures in Dietary Supplements
Nanomaterials are beginning to enter our daily lives through various consumer products as the result of technology commercialization. The development of methodologies to detect the presence of nanomaterials in consumer products is an essential element in understanding our exposure. In this study, we have developed methods for the separation and characterization of silicon dioxide (SiO2) and titanium dioxide (TiO2) nanostructures in dietary supplements marketed in products specifically targeted for women. A total of 12 commercial products claiming the inclusion of SiO2 and TiO2, but not making any claims regarding the particle size, were randomly selected for purchase through various retailers. To isolate nanostructures from these products, a simple methodology that combines acid digestion and centrifugation was utilized. Once isolated, the chemical composition, size, morphology, and crystal structure were characterized using mass spectroscopy, light scattering, electron microscopy, and X-ray diffraction techniques. SiO2 and TiO2 nanostructures were detected in 11 of 12 products using these methods. Many of the isolated nanoscale materials showed a high degree of aggregation; however, identified individual structures had at least one dimension below 100 nm. These robust methods can be used for routine monitoring of commercial products for nanoscale oxides of silica and titanium.
- 18 March 2015
- Published by American Chemical Society (ACS) in Journal of Agricultural and Food Chemistry
- Vol. 63 (12) , 3144-3152
Detection and Characterization of SiO2 and TiO2 Nanostructures in Dietary Supplements
Nanomaterials are beginning to enter our daily lives through various consumer products as the result of technology commercialization. The development of methodologies to detect the presence of nanomaterials in consumer products is an essential element in understanding our exposure. In this study, we have developed methods for the separation and characterization of silicon dioxide (SiO2) and titanium dioxide (TiO2) nanostructures in dietary supplements marketed in products specifically targeted for women. A total of 12 commercial products claiming the inclusion of SiO2 and TiO2, but not making any claims regarding the particle size, were randomly selected for purchase through various retailers. To isolate nanostructures from these products, a simple methodology that combines acid digestion and centrifugation was utilized. Once isolated, the chemical composition, size, morphology, and crystal structure were characterized using mass spectroscopy, light scattering, electron microscopy, and X-ray diffraction techniques. SiO2 and TiO2 nanostructures were detected in 11 of 12 products using these methods. Many of the isolated nanoscale materials showed a high degree of aggregation; however, identified individual structures had at least one dimension below 100 nm. These robust methods can be used for routine monitoring of commercial products for nanoscale oxides of silica and titanium.
- 22 July 2013
- Published by American Chemical Society (ACS) in Journal of Agricultural and Food Chemistry
- Vol. 61 (30) , 7250-7257
Rapid Determination of Silver in Nanobased Liquid Dietary Supplements Using a Portable X-ray Fluorescence Analyzer
This paper reports a rapid and straightforward method for the quantitation of total Ag content in nanobased commercially available liquid dietary supplements using a portable X-ray fluorescence (pXRF) analyzer. Figures of merits were evaluated by analyzing a series of AgNO3 standards. This method was shown to have a detection limit of 3 ppm, a quantitation limit of 10 ppm, and a broad linear range from the detection limit to 10000 ppm (1%). Accurate detection and quantitation of Ag content in well-characterized Ag nanoparticle samples and in nanobased liquid dietary supplements were achieved with good correlation (i.e., percentage difference average values under 15%) between the total Ag concentration obtained by the pXRF analyzer and by inductively coupled plasma mass spectrometry (ICP-MS). Furthermore, accurate quantitation of Ag in the presence of high concentrations of potential spectral interferences was also demonstrated.
- 22 July 2013
- Published by American Chemical Society (ACS) in Journal of Agricultural and Food Chemistry
- Vol. 61 (30) , 7250-7257
Rapid Determination of Silver in Nanobased Liquid Dietary Supplements Using a Portable X-ray Fluorescence Analyzer
This paper reports a rapid and straightforward method for the quantitation of total Ag content in nanobased commercially available liquid dietary supplements using a portable X-ray fluorescence (pXRF) analyzer. Figures of merits were evaluated by analyzing a series of AgNO3 standards. This method was shown to have a detection limit of 3 ppm, a quantitation limit of 10 ppm, and a broad linear range from the detection limit to 10000 ppm (1%). Accurate detection and quantitation of Ag content in well-characterized Ag nanoparticle samples and in nanobased liquid dietary supplements were achieved with good correlation (i.e., percentage difference average values under 15%) between the total Ag concentration obtained by the pXRF analyzer and by inductively coupled plasma mass spectrometry (ICP-MS). Furthermore, accurate quantitation of Ag in the presence of high concentrations of potential spectral interferences was also demonstrated.