Ludovic Kaminski
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ludovic Kaminski has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Xavier Banse
Service d'orthopédie et de traumatologie de l'appareil locomoteur, Cliniques universitaires Saint-Luc, Avenue Hippocrate 10, B-1200, Brussels, Belgium
3 shared publications- Virginie Cordemans
Neuro Musculo Skeletal Lab (NMSK), Institut de Recherche Expérimentale et Clinique, Université Catholique de Louvain-la-Neuve, UCL/IREC/CARS, Brussels, Belgium
2 shared publications - Bernard G. Francq
GSK, Rixensart, Belgium
1 shared publication - Christine Detrembleur
Neuro Musculo Skeletal Lab, Institute of Experimental and Clinical Research, Université Catholique de Louvain
1 shared publication - Edouard Cernat
Central Military University Hospital "Dr. Carol Davila ," Bucharest, Romania
1 shared publication - Jean-Marc Mac-Thiong
Faculty of Medicine, University of Montreal, Montréal, Canada
1 shared publication
Latest Publications
- 22 July 2017
- Published by Springer Nature in European Spine Journal
- Vol. 26 (11) , 2818-2827
Radiation dose reduction in thoracic and lumbar spine instrumentation using navigation based on an intraoperative cone beam CT imaging system: a prospective randomized clinical trial
Spine surgery still remains a challenge for every spine surgeon, aware of the potential serious outcomes of misplaced instrumentation. Though many studies have highlighted that using intraoperative cone beam CT imaging and navigation systems provides higher accuracy than conventional freehand methods for placement of pedicle screws in spine surgery, few studies are concerned about how to reduce radiation exposure for patients with the use of such technology. One of the main focuses of this study is based on the ALARA principle (as low as reasonably achievable).
- 22 July 2017
- Published by Springer Nature in European Spine Journal
- Vol. 26 (11) , 2818-2827
Radiation dose reduction in thoracic and lumbar spine instrumentation using navigation based on an intraoperative cone beam CT imaging system: a prospective randomized clinical trial
Spine surgery still remains a challenge for every spine surgeon, aware of the potential serious outcomes of misplaced instrumentation. Though many studies have highlighted that using intraoperative cone beam CT imaging and navigation systems provides higher accuracy than conventional freehand methods for placement of pedicle screws in spine surgery, few studies are concerned about how to reduce radiation exposure for patients with the use of such technology. One of the main focuses of this study is based on the ALARA principle (as low as reasonably achievable).
- 19 June 2017
- Published by Springer Nature in European Spine Journal
- Vol. 26 (11) , 2917-2926
Pedicle screw insertion accuracy in terms of breach and reposition using a new intraoperative cone beam computed tomography imaging technique and evaluation of the factors associated with these parameters of accuracy: a series of 695 screws
Purpose The goals of this study were to assess the accuracy of pedicle screw insertion using an intraoperative cone beam computed tomography (CBCT) system, and to analyze the factors potentially influencing this accuracy. Methods Six hundred and ninety-five pedicle screws were inserted in 118 patients between October 2013 and March 2016. Screw insertion was performed using 2D-fluoroscopy or CBCT-based navigation. Accuracy was assessed in terms of breach and reposition. All the intraoperative CBCT scans, done after screw insertion, were reviewed to assess the accuracy of screw placement using two established classification systems: Gertzbein and Heary. Generalized linear mixed models were used to model the odds (95% CI) for a screw to lead to a breach according to the independent variables. Results The breach rate was 11.7% using the Gertzbein classification and 15.4% using the Heary classification. Seventeen screws (2.4%) were repositioned intraoperatively. The only factor affecting statistically the odds to have a breach was the indication of surgery. The patients with non-degenerative disease had a significantly higher risk of breach than those with degenerative disease. Conclusion Use of intraoperative CBCT as 2D-fluoroscopy or coupled with a navigation system for pedicle screw insertion is accurate in terms of breach occurrence and reposition. However, these rates depend on the classification or grading system used. Use of a navigation system does not decrease the risk of breach significantly. And the risk of breach is higher in non-degenerative conditions (trauma, scoliosis, infection, and malignancy disease) than in degenerative diseases.
- 19 June 2017
- Published by Springer Nature in European Spine Journal
- Vol. 26 (11) , 2917-2926
Pedicle screw insertion accuracy in terms of breach and reposition using a new intraoperative cone beam computed tomography imaging technique and evaluation of the factors associated with these parameters of accuracy: a series of 695 screws
Purpose The goals of this study were to assess the accuracy of pedicle screw insertion using an intraoperative cone beam computed tomography (CBCT) system, and to analyze the factors potentially influencing this accuracy. Methods Six hundred and ninety-five pedicle screws were inserted in 118 patients between October 2013 and March 2016. Screw insertion was performed using 2D-fluoroscopy or CBCT-based navigation. Accuracy was assessed in terms of breach and reposition. All the intraoperative CBCT scans, done after screw insertion, were reviewed to assess the accuracy of screw placement using two established classification systems: Gertzbein and Heary. Generalized linear mixed models were used to model the odds (95% CI) for a screw to lead to a breach according to the independent variables. Results The breach rate was 11.7% using the Gertzbein classification and 15.4% using the Heary classification. Seventeen screws (2.4%) were repositioned intraoperatively. The only factor affecting statistically the odds to have a breach was the indication of surgery. The patients with non-degenerative disease had a significantly higher risk of breach than those with degenerative disease. Conclusion Use of intraoperative CBCT as 2D-fluoroscopy or coupled with a navigation system for pedicle screw insertion is accurate in terms of breach occurrence and reposition. However, these rates depend on the classification or grading system used. Use of a navigation system does not decrease the risk of breach significantly. And the risk of breach is higher in non-degenerative conditions (trauma, scoliosis, infection, and malignancy disease) than in degenerative diseases.
- 15 June 2017
- Published by SAGE Publications in Journal of Neurotrauma
- Vol. 34 (12) , 2027-2033
Functional Outcome Prediction after Traumatic Spinal Cord Injury Based on Acute Clinical Factors
Spinal cord injury (SCI) is a devastating condition that affects patient on a personal as well as on a societal level. The objective of the study is to improve the prediction of long-term functional outcome following SCI based on the acute clinical findings. 76 patients with acute traumatic SCI were prospectively enrolled in a cohort study in a single level I trauma center. Spinal Cord Independence Measure (SCIM) at 1 year after the trauma was the primary outcome. Potential predictors of functional outcome were recorded during the acute hospitalization: age, sex, level and type of injury, comorbidities, American Spinal Injury Association (ASIA) Impairment Scale (AIS), ASIA Motor Score (AMS), ASIA Light Touch score (LT), ASIA Pin Prick score (PP), Injury Severity Score (ISS), Traumatic Brain Injury (TBI) and delay from trauma to surgery. A linear regression model was created with the primary outcome modeled relative to the acute clinical findings. Only four variables were selected in the model which performance averaged an R-square of 0.57. In descending order, the best predictors for SCIM at 1 year were: LT, AIS grade, ISS and AMS. One year functional outcome (SCIM) can be estimated by a simple equation that takes into account four parameters of the initial physical examination. Estimating the patient long-term outcome early after traumatic SCI is important in order to define the management strategies that might diminish the costs and to give the patient and family a better view of the long-term expectations. Keywords: Spinal cord injury; ASIA impairment scale; Functional outcome; Clinical prediction model
- 15 June 2017
- Published by SAGE Publications in Journal of Neurotrauma
- Vol. 34 (12) , 2027-2033
Functional Outcome Prediction after Traumatic Spinal Cord Injury Based on Acute Clinical Factors
Spinal cord injury (SCI) is a devastating condition that affects patient on a personal as well as on a societal level. The objective of the study is to improve the prediction of long-term functional outcome following SCI based on the acute clinical findings. 76 patients with acute traumatic SCI were prospectively enrolled in a cohort study in a single level I trauma center. Spinal Cord Independence Measure (SCIM) at 1 year after the trauma was the primary outcome. Potential predictors of functional outcome were recorded during the acute hospitalization: age, sex, level and type of injury, comorbidities, American Spinal Injury Association (ASIA) Impairment Scale (AIS), ASIA Motor Score (AMS), ASIA Light Touch score (LT), ASIA Pin Prick score (PP), Injury Severity Score (ISS), Traumatic Brain Injury (TBI) and delay from trauma to surgery. A linear regression model was created with the primary outcome modeled relative to the acute clinical findings. Only four variables were selected in the model which performance averaged an R-square of 0.57. In descending order, the best predictors for SCIM at 1 year were: LT, AIS grade, ISS and AMS. One year functional outcome (SCIM) can be estimated by a simple equation that takes into account four parameters of the initial physical examination. Estimating the patient long-term outcome early after traumatic SCI is important in order to define the management strategies that might diminish the costs and to give the patient and family a better view of the long-term expectations. Keywords: Spinal cord injury; ASIA impairment scale; Functional outcome; Clinical prediction model
- 6 February 2017
- Published by Springer Nature in European Spine Journal
- Vol. 26 (11) , 2811-2817
Radiation exposure to the patients in thoracic and lumbar spine fusion using a new intraoperative cone-beam computed tomography imaging technique: a preliminary study
The goals of this paper are to assess the ionizing radiation exposure to the patients during thoracic and lumbar spinal fusion using a new intraoperative 3D imaging system and to evaluate the factors that could explain the variability in the observed doses.
- 6 February 2017
- Published by Springer Nature in European Spine Journal
- Vol. 26 (11) , 2811-2817
Radiation exposure to the patients in thoracic and lumbar spine fusion using a new intraoperative cone-beam computed tomography imaging technique: a preliminary study
The goals of this paper are to assess the ionizing radiation exposure to the patients during thoracic and lumbar spinal fusion using a new intraoperative 3D imaging system and to evaluate the factors that could explain the variability in the observed doses.
- 9 February 2013
- Published by Springer Nature in European Spine Journal
- Vol. 22 (8) , 1868-1876
Time spent per patient in lumbar spinal stenosis surgery
Purpose To examine the time needed from a surgeon’s viewpoint to treat a patient operated for lumbar spinal stenosis. We firstly aimed to give evidence of the wide ranging duration of standardized procedure. Secondly, we investigated factors affecting the time allocated to each patient. Methods 438 medical records of patients operated on for lumbar decompression without fusion (2005–2011) were retrospectively examined. Primary data were operative time (OT, min), length of stay (LoS, days) and number of postoperative visits. A fourth parameter was calculated, the time spent per patient (TSPP, min) by summing the time spent in surgery, during inpatient and outpatient follow-up visits. Factors that influenced these medical resources were examined. Results Median (5th–95th percentile) LoS was 5 days (2–15), OT 106 min (60–194), number of medical visits 5 (2–11) and TSPP 329 min (206–533). In descending order, factors predicting LoS were age, no. of levels, sex, operative technique, cardiovascular risk index, dural tear and haematoma. Factors predicting OT were number of levels, dural tear, foraminotomy, synovial cyst and body mass index. The statistical model could predict 36 % of the TSPP variance. We recommend that surgeons add 35 min for each level, 29 min for patients over 65 years, 30 min for women, 132 min for dural tear and 108 min for epidural haematoma. Conclusion TSPP treated for lumbar spinal stenosis is highly variable, yet partially predictable. These data may help individual surgeons or heads of departments to plan their activities.
- 9 February 2013
- Published by Springer Nature in European Spine Journal
- Vol. 22 (8) , 1868-1876
Time spent per patient in lumbar spinal stenosis surgery
Purpose To examine the time needed from a surgeon’s viewpoint to treat a patient operated for lumbar spinal stenosis. We firstly aimed to give evidence of the wide ranging duration of standardized procedure. Secondly, we investigated factors affecting the time allocated to each patient. Methods 438 medical records of patients operated on for lumbar decompression without fusion (2005–2011) were retrospectively examined. Primary data were operative time (OT, min), length of stay (LoS, days) and number of postoperative visits. A fourth parameter was calculated, the time spent per patient (TSPP, min) by summing the time spent in surgery, during inpatient and outpatient follow-up visits. Factors that influenced these medical resources were examined. Results Median (5th–95th percentile) LoS was 5 days (2–15), OT 106 min (60–194), number of medical visits 5 (2–11) and TSPP 329 min (206–533). In descending order, factors predicting LoS were age, no. of levels, sex, operative technique, cardiovascular risk index, dural tear and haematoma. Factors predicting OT were number of levels, dural tear, foraminotomy, synovial cyst and body mass index. The statistical model could predict 36 % of the TSPP variance. We recommend that surgeons add 35 min for each level, 29 min for patients over 65 years, 30 min for women, 132 min for dural tear and 108 min for epidural haematoma. Conclusion TSPP treated for lumbar spinal stenosis is highly variable, yet partially predictable. These data may help individual surgeons or heads of departments to plan their activities.