Fernando Bliacheriene
Fernando Bliacheriene has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Maria José Carvalho Carmona
Universidade de São Paulo (USP), São Paulo, SP, Brazil
3 shared publications - Maria Rita de Figueiredo Lemos Bortolotto
Universidade de Sao Paulo, Sao Paulo, Brasil
3 shared publications Cristiane Maria Federicci Haddad
HCFMUSP
2 shared publicationsCristina de Freitas Madeira Barretti
HCFMUSP
2 shared publicationsElaine Soubhi Mouchalwat
HCFMUSP
2 shared publicationsMarcelo Zugaib
FMUSP
2 shared publications
Latest Publications
- 27 August 2012
- Published by Elsevier in International Journal of Obstetric Anesthesia
- Vol. 21 (4) , 388-389
Anesthesia for cardiac surgery under cardiopulmonary bypass in pregnant patients: experience with nine cases
- 27 August 2012
- Published by Elsevier in International Journal of Obstetric Anesthesia
- Vol. 21 (4) , 388-389
Anesthesia for cardiac surgery under cardiopulmonary bypass in pregnant patients: experience with nine cases
- 1 October 2011
- Published by Elsevier in Revista Brasileira de Anestesiologia
- Vol. 61 (5) , 614-618
Utilização de monitor minimamente invasivo não calibrado de débito cardíaco em pacientes submetidas à cesariana sob raquianestesia: relato de quatro casos
- 1 October 2011
- Published by Elsevier in Revista Brasileira de Anestesiologia
- Vol. 61 (5) , 614-618
Utilização de monitor minimamente invasivo não calibrado de débito cardíaco em pacientes submetidas à cesariana sob raquianestesia: relato de quatro casos
- Open Access
- 1 September 2011
- Published by Elsevier in Revista Brasileira de Anestesiologia
- Vol. 61 (5) , 610-618
Use of a Minimally Invasive Uncalibrated Cardiac Output Monitor in Patients Undergoing Cesarean Section under Spinal Anesthesia: Report of Four Cases
- 1 September 2011
- Published by Elsevier in Revista Brasileira de Anestesiologia
- Vol. 61 (5) , 610-618
Open AccessUse of a Minimally Invasive Uncalibrated Cardiac Output Monitor in Patients Undergoing Cesarean Section under Spinal Anesthesia: Report of Four Cases
- 20 August 2007
- Published by Wiley in Acta Anaesthesiologica Scandinavica
- Vol. 51 (9) , 1268-1272
Pulse pressure variation as a tool to detect hypovolaemia during pneumoperitoneum
Background: Pulse pressure variation (ΔPP) and systolic pressure variation (SPV) induced by mechanical ventilation have been proposed to detect hypovolaemia and guide fluid therapy. During laparoscopic surgery, chest compliance is decreased by pneumoperitoneum. This may affect the value of SPV and ΔPP as indicators of intravascular volume status. Thereby, we investigated the effects of pneumoperitoneum and hypovolaemia on SPV and ΔPP.Methods: We measured ΔPP, SPV and the inspiratory (Δup) and expiratory (Δdown) components of SPV, at baseline, during pneumoperitoneum, during pneumoperitoneum and hypovolaemia and after the return to baseline conditions, in 11 mechanically ventilated rabbits. Pneumoperitoneum was induced by inflating the abdomen with carbon dioxide, and hypovolaemia was induced by controlled haemorrhage.Results: Pneumoperitoneum induced an increase in SPV from 8.5 ± 1.6 to 13.3 ± 2.6 mmHg (+56%, P < 0.05) as a result of an increase in Δup from 2.0 ± 1.0 to 6.7 ± 2.1 mmHg (+236%, P < 0.05), but no significant change in Δdown, nor in ΔPP. Haemorrhage induced a significant (P < 0.05) increase in SPV from 13.3 ± 2.6 to 19.9 ± 3.7 mmHg (+50%), in Δdown from 6.6 ± 3.3 to 14.0 ± 4.9 mmHg (+112%) and in ΔPP from 11.1 ± 4.8 to 24.9 ± 9.8% (+124%) but no change in Δup. All parameters returned to baseline values after blood re‐infusion and abdominal deflation.Conclusions: SPV is modified by haemorrhage but it is also influenced by pneumoperitoneum. In contrast, ΔPP is modified by haemorrhage but not by pneumoperitoneum. These findings suggest that ΔPP should be used preferentially instead of SPV to detect hypovolaemia and guide fluid therapy during laparoscopic surgery.
- 20 August 2007
- Published by Wiley in Acta Anaesthesiologica Scandinavica
- Vol. 51 (9) , 1268-1272
Pulse pressure variation as a tool to detect hypovolaemia during pneumoperitoneum
Background: Pulse pressure variation (ΔPP) and systolic pressure variation (SPV) induced by mechanical ventilation have been proposed to detect hypovolaemia and guide fluid therapy. During laparoscopic surgery, chest compliance is decreased by pneumoperitoneum. This may affect the value of SPV and ΔPP as indicators of intravascular volume status. Thereby, we investigated the effects of pneumoperitoneum and hypovolaemia on SPV and ΔPP.Methods: We measured ΔPP, SPV and the inspiratory (Δup) and expiratory (Δdown) components of SPV, at baseline, during pneumoperitoneum, during pneumoperitoneum and hypovolaemia and after the return to baseline conditions, in 11 mechanically ventilated rabbits. Pneumoperitoneum was induced by inflating the abdomen with carbon dioxide, and hypovolaemia was induced by controlled haemorrhage.Results: Pneumoperitoneum induced an increase in SPV from 8.5 ± 1.6 to 13.3 ± 2.6 mmHg (+56%, P < 0.05) as a result of an increase in Δup from 2.0 ± 1.0 to 6.7 ± 2.1 mmHg (+236%, P < 0.05), but no significant change in Δdown, nor in ΔPP. Haemorrhage induced a significant (P < 0.05) increase in SPV from 13.3 ± 2.6 to 19.9 ± 3.7 mmHg (+50%), in Δdown from 6.6 ± 3.3 to 14.0 ± 4.9 mmHg (+112%) and in ΔPP from 11.1 ± 4.8 to 24.9 ± 9.8% (+124%) but no change in Δup. All parameters returned to baseline values after blood re‐infusion and abdominal deflation.Conclusions: SPV is modified by haemorrhage but it is also influenced by pneumoperitoneum. In contrast, ΔPP is modified by haemorrhage but not by pneumoperitoneum. These findings suggest that ΔPP should be used preferentially instead of SPV to detect hypovolaemia and guide fluid therapy during laparoscopic surgery.