Yukinaga Yoshida
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yukinaga Yoshida has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
Hisao Tajiri
The Jikei University School of Medicine
5 shared publicationsJin Yonezawa
4 shared publicationsMasayuki Kato
4 shared publications- Mitsuru Kaise
Department of Gastroenterology, Toranomon Hospital, Tokyo, Japan
4 shared publications - Hisao Tajiri
The Jikei University School of Medicine
3 shared publications Noboru Yoshimura
3 shared publications
Latest Publications
- 29 June 2013
- Published by Springer Nature in International Journal of Colorectal Disease
- Vol. 28 (11) , 1511-1516
A randomized crossover open trial of the adenoma miss rate for narrow band imaging (NBI) versus flexible spectral imaging color enhancement (FICE)
Narrow band imaging (NBI) and flexible spectral imaging color enhancement (FICE) allow improved contrasted evaluation of the mucosal surface. However, no study has compared the utility of these two modalities. Therefore, the aim of this study was to compare the adenoma miss rate (AMR) between NBI and FICE. A total of 55 patients (38 men, 17 women) were enrolled in this study. Patients were randomly assigned to the NBI–FICE group (NBI followed by FICE) or the FICE–NBI group (FICE followed by NBI). NBI and FICE total colonic observations were tandemly performed for each patient during the scope withdrawal with white light following cecal intubation. All detected polyps with the NBI or FICE observation were categorized into three groups according to the size and number of polyps missed. Twenty-nine patients were assigned to the NBI–FICE group, and 26 patients were assigned to the FICE–NBI group. There was no significant difference in the overall AMR when comparing the image-enhanced endoscopy technologies (17.9 % for NBI, 26 % for FICE, p = 0.159). AMR was lower for NBI than for FICE for adenomas p = 0.036). AMR was not significantly different when comparing NBI and FICE for lesions 5 to 10 mm (p = 0.967) or for lesions ≥10 mm (p = 0.269). This study demonstrated that overall AMR was not different when comparing NBI and FICE.
- 29 June 2013
- Published by Springer Nature in International Journal of Colorectal Disease
- Vol. 28 (11) , 1511-1516
A randomized crossover open trial of the adenoma miss rate for narrow band imaging (NBI) versus flexible spectral imaging color enhancement (FICE)
Narrow band imaging (NBI) and flexible spectral imaging color enhancement (FICE) allow improved contrasted evaluation of the mucosal surface. However, no study has compared the utility of these two modalities. Therefore, the aim of this study was to compare the adenoma miss rate (AMR) between NBI and FICE. A total of 55 patients (38 men, 17 women) were enrolled in this study. Patients were randomly assigned to the NBI–FICE group (NBI followed by FICE) or the FICE–NBI group (FICE followed by NBI). NBI and FICE total colonic observations were tandemly performed for each patient during the scope withdrawal with white light following cecal intubation. All detected polyps with the NBI or FICE observation were categorized into three groups according to the size and number of polyps missed. Twenty-nine patients were assigned to the NBI–FICE group, and 26 patients were assigned to the FICE–NBI group. There was no significant difference in the overall AMR when comparing the image-enhanced endoscopy technologies (17.9 % for NBI, 26 % for FICE, p = 0.159). AMR was lower for NBI than for FICE for adenomas p = 0.036). AMR was not significantly different when comparing NBI and FICE for lesions 5 to 10 mm (p = 0.967) or for lesions ≥10 mm (p = 0.269). This study demonstrated that overall AMR was not different when comparing NBI and FICE.
- 1 May 2013
- Published by Wolters Kluwer Health in European Journal of Gastroenterology & Hepatology
- Vol. 25 (5) , 575-579
Glucagon facilitates colonoscopy and reduces patient discomfort
Randomized placebo-controlled trials on the effectiveness of glucagon in colonoscopy were conducted more than a decade ago and the outcomes varied for each study. Since then, techniques and imaging technology in colonoscopy have steadily improved. The aim of this study was to re-evaluate the effectiveness of glucagon as an antispasmodic, which may facilitate smooth scope intubation and reduce patient discomfort during screening colonoscopy under current equipment settings. A total of 70 patients undergoing colonoscopy under conscious sedation were randomized into two groups: a group with intravenous administration of 1 mg glucagon and a placebo group. After colonoscopy, patients completed questionnaires on pain, abdominal fullness, and acceptance of future colonoscopy. Difficulty in scope manipulation was scored by endoscopists, and times for cecal intubation, observation, and the number of polyps detected by colonoscopy were also recorded. In addition, we evaluated patient discomfort objectively with a newly developed portable analyzer of salivary amylase activity. This study was performed double-blind, and assignments were not disclosed to patients or to endoscopists. Scores for acceptance for future colonoscopy, pain, abdominal fullness, and scope manipulation were significantly lower in the glucagon group. Salivary amylase activity, determined at the time the scope was inserted to the cecum, was significantly lower in the glucagon group, and cecal intubation time was significantly shorter in the glucagon group. Observation time and polyp detection rate were not significantly different between the groups. These results indicate that intravenous administration of glucagon can reduce patient discomfort and improve scope intubation during screening colonoscopy.
- 1 May 2013
- Published by Wolters Kluwer Health in European Journal of Gastroenterology & Hepatology
- Vol. 25 (5) , 575-579
Glucagon facilitates colonoscopy and reduces patient discomfort
Randomized placebo-controlled trials on the effectiveness of glucagon in colonoscopy were conducted more than a decade ago and the outcomes varied for each study. Since then, techniques and imaging technology in colonoscopy have steadily improved. The aim of this study was to re-evaluate the effectiveness of glucagon as an antispasmodic, which may facilitate smooth scope intubation and reduce patient discomfort during screening colonoscopy under current equipment settings. A total of 70 patients undergoing colonoscopy under conscious sedation were randomized into two groups: a group with intravenous administration of 1 mg glucagon and a placebo group. After colonoscopy, patients completed questionnaires on pain, abdominal fullness, and acceptance of future colonoscopy. Difficulty in scope manipulation was scored by endoscopists, and times for cecal intubation, observation, and the number of polyps detected by colonoscopy were also recorded. In addition, we evaluated patient discomfort objectively with a newly developed portable analyzer of salivary amylase activity. This study was performed double-blind, and assignments were not disclosed to patients or to endoscopists. Scores for acceptance for future colonoscopy, pain, abdominal fullness, and scope manipulation were significantly lower in the glucagon group. Salivary amylase activity, determined at the time the scope was inserted to the cecum, was significantly lower in the glucagon group, and cecal intubation time was significantly shorter in the glucagon group. Observation time and polyp detection rate were not significantly different between the groups. These results indicate that intravenous administration of glucagon can reduce patient discomfort and improve scope intubation during screening colonoscopy.
- Open Access
- 8 February 2013
- Published by Springer Nature in Gastric Cancer
- Vol. 17 (1) , 116-121
A pilot study using an infrared imaging system in prevention of post-endoscopic submucosal dissection ulcer bleeding
Endoscopic submucosal dissection (ESD) for superficial gastric neoplasm is a curative method. The aim of this study was to detect potential nonbleeding visible vessels (NBVVs) by using an infrared imaging (IRI) system. A total of 24 patients (25 lesions) were consecutively enrolled between March 2010 and December 2010. The day after ESD, endoscopist A (K.M.), who was blinded to the actual procedure of ESD, performed esophagogastroduodenoscopy (EGD) of the post-ESD ulcer base using the IRI system. Endoscopist A marked gray/blue points in the hard-copy images with the IRI system. After the first procedure, endoscopist B (Y.Y.), who was blinded to the results recorded by endoscopist A, performed a second EGD with white light endoscopy and administered water-jet pressure with the maximum level of an Olympus flushing pump onto the post-ESD ulcer base. This test can cause iatrogenic bleeding via application of pressure to NBVV in the post-ESD ulcer. The IRI system detected 58 gray points and 71 blue points. The post-ESD ulcer was divided into the central area and the peripheral area. There were 14 gray points (24 %) in the central area and 44 gray points (76 %) in the peripheral area. There were 19 blue points (27 %) in the central area and 52 blue points (73 %) in the peripheral area. There was no significant difference when comparing the distribution of gray points and blue points. Bleeding occurred with a water-jet pressure in 11 of 58 gray points and in none of the blue points (P = 0.000478). Among the gray points, bleeding in response to a water-jet pressure occurred in 2 points in the central area and in 9 points in the peripheral area. The IRI system detects visible vessels (VVs) that are in no need of coagulation as blue points, and VVs have a potential risk of bleeding as gray points.
- 8 February 2013
- Published by Springer Nature in Gastric Cancer
- Vol. 17 (1) , 116-121
Open AccessA pilot study using an infrared imaging system in prevention of post-endoscopic submucosal dissection ulcer bleeding
Endoscopic submucosal dissection (ESD) for superficial gastric neoplasm is a curative method. The aim of this study was to detect potential nonbleeding visible vessels (NBVVs) by using an infrared imaging (IRI) system. A total of 24 patients (25 lesions) were consecutively enrolled between March 2010 and December 2010. The day after ESD, endoscopist A (K.M.), who was blinded to the actual procedure of ESD, performed esophagogastroduodenoscopy (EGD) of the post-ESD ulcer base using the IRI system. Endoscopist A marked gray/blue points in the hard-copy images with the IRI system. After the first procedure, endoscopist B (Y.Y.), who was blinded to the results recorded by endoscopist A, performed a second EGD with white light endoscopy and administered water-jet pressure with the maximum level of an Olympus flushing pump onto the post-ESD ulcer base. This test can cause iatrogenic bleeding via application of pressure to NBVV in the post-ESD ulcer. The IRI system detected 58 gray points and 71 blue points. The post-ESD ulcer was divided into the central area and the peripheral area. There were 14 gray points (24 %) in the central area and 44 gray points (76 %) in the peripheral area. There were 19 blue points (27 %) in the central area and 52 blue points (73 %) in the peripheral area. There was no significant difference when comparing the distribution of gray points and blue points. Bleeding occurred with a water-jet pressure in 11 of 58 gray points and in none of the blue points (P = 0.000478). Among the gray points, bleeding in response to a water-jet pressure occurred in 2 points in the central area and in 9 points in the peripheral area. The IRI system detects visible vessels (VVs) that are in no need of coagulation as blue points, and VVs have a potential risk of bleeding as gray points.
- 1 April 2012
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 75 (4) , AB489
Tu1688 How Fast Does a Surgical Resident Learn Colonoscopy? -Analysis of Competency in Colonoscopy for Ten Surgical Residents Supervised by Expert Endoscopists (Gastroenterologists) in the High-Volume Endoscopy Center in Japan-
- 1 April 2012
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 75 (4) , AB489
Tu1688 How Fast Does a Surgical Resident Learn Colonoscopy? -Analysis of Competency in Colonoscopy for Ten Surgical Residents Supervised by Expert Endoscopists (Gastroenterologists) in the High-Volume Endoscopy Center in Japan-
- 30 April 2009
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 69 (5) , AB177
Bacteremia and Endotoxemia After Endoscopic Submucosal Dissection for Gastric Neoplasia
- 30 April 2009
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 69 (5) , AB177
Bacteremia and Endotoxemia After Endoscopic Submucosal Dissection for Gastric Neoplasia
- 30 April 2009
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 69 (5) , AB343
Ultra-Minute Intraepithelial Squamous Neoplasia in the Esophagus: Histopathological Features and Utility of Narrow-Band Imaging Endoscopy
- 30 April 2009
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 69 (5) , AB343
Ultra-Minute Intraepithelial Squamous Neoplasia in the Esophagus: Histopathological Features and Utility of Narrow-Band Imaging Endoscopy
- 1 January 2006
- Published by Japan Gastrointestinal Endoscopy Society in Progress of Digestive Endoscopy
- Vol. 69 (2) , 110-111
A case of bile duct stricture after orthotopic liver transplantation successfully treated with drainage and stenting by rendezvous method
- 1 January 2006
- Published by Japan Gastrointestinal Endoscopy Society in Progress of Digestive Endoscopy
- Vol. 69 (2) , 110-111
A case of bile duct stricture after orthotopic liver transplantation successfully treated with drainage and stenting by rendezvous method