WBWilliam G. Brodbeck

William G. Brodbeck

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


William G. Brodbeck has a total of 16 co-authors. Here are the top co-authors by number of shared publications:

  • Gabriela Voskerician

    Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio 44106

    2 shared publications
  • Matthew S. Shive

    Departments of *Pathology and ‡Biomedical Engineering, Case Western Reserve University, Cleveland, OH 44139;§ Department of Bioengineering, National Cardiovascular Center, Osaka 562-0025, Japan; and ¶Department of Biomedical Engineering, Kyushu University, Fukuoka 812-8482, Japan

    2 shared publications
  • Nicholas P. Ziats

    Department of Pathology, Case Western Reserve University, Cleveland, Ohio 44106

    2 shared publications
  • Takehisa Matsuda

    Department of Biomedical Engineering, Kyushu University, Fukuoka, Japan

    2 shared publications
  • William G. Brodbeck

    Department of Pathology, Case Western Reserve University, Cleveland, Ohio 44106, USA

    2 shared publications
  • Yasuhide Nakayama

    Department of Bioengineering, National Cardiovascular Center, Osaka, Japan

    2 shared publications

Latest Publications

  • Effects of adsorbed heat labile serum proteins and fibrinogen on adhesion and apoptosis of monocytes/macrophages on biomaterials

    by William G. Brodbeck, Erica Colton, James M. Anderson

    A previously established human monocyte culture protocol was used to determine the effects of varying adsorbed proteins on monocyte/macrophage adhesion and survival on dimethyl-silane (DM) or RGD...


  • In vivo leukocyte cytokine mRNA responses to biomaterials are dependent on surface chemistry

    by William G. Brodbeck, Gabriela Voskerician, Nicholas P. Ziats, Yasuhide Nakayama, Takehisa Matsuda, James M. Anderson

    An in vivo mouse cage implant system was used to determine whether leukocyte cytokine mRNA responses to implanted biomaterials were dependent on surface chemistry. Surfaces displaying various chemistries (hydrophobic, hydrophilic, anionic, and cationic) were placed into stainless steel cages and implanted subcutaneously. Semiquantitative RT‐PCR analyses revealed that hydrophilic surfaces showed a decreased expression of proinflammatory cytokines, IL‐6 and IL‐8, and pro‐wound healing cytokines, IL‐10 and TGF‐β by adherent cells, and mRNA levels of the proinflammatory cytokine, IL‐1β, and the pro‐wound healing cytokine IL‐13 were decreased in surrounding, exudate cells. Cytokine responses by adherent and exudate cells to hydrophobic, anionic and cationic surfaces were similar and indicative of a strong inflammatory response at the earliest time point followed by a wound healing response at later time points. However, no differences in the types or levels of exudate cells for any of the surfaces or the empty cage at each of the respective time points were observed, indicating their respective biocompatibility. These studies identify hydrophilic surface chemistries as having significant effects on leukocyte cytokine responses in vivo by decreasing the expression of inflammatory and wound healing cytokines by inflammatory cells adherent to the biomaterial as well as present in the surrounding exudate. © 2002 Wiley Periodicals, Inc. J Biomed Mater Res 64A: 320–329, 2003


  • Open Access

    Biomaterial adherent macrophage apoptosis is increased by hydrophilic and anionic substratesinvivo

    by William G. Brodbeck, Jasmine Patel, Gabriela Voskerician, Elizabeth Christenson, Matthew S. Shive, Yasuhide Nakayama, Takehisa Matsuda, Nicholas P. Ziats, James M. Anderson

    Anin vivorat cage implant system was used to identify potential surface chemistries that prevent failure of implanted biomedical devices and prostheses by limiting monocyte adhesion and macrophage fusion into foreign-body giant cells while inducing adherent-macrophage apoptosis. Hydrophobic, hydrophilic, anionic, and cationic surfaces were used for implantation. Analysis of the exudate surrounding the materials revealed no differences between surfaces in the types or levels of cells present. Conversely, the proportion of adherent cells undergoing apoptosis was increased significantly on anionic and hydrophilic surfaces (46 ± 3.7 and 57 ± 5.0%, respectively) when compared with the polyethylene terephthalate base surface. Additionally, hydrophilic and anionic substrates provided decreased rates of monocyte/macrophage adhesion and fusion. These studies demonstrate that biomaterial-adherent cells undergo material-dependent apoptosisin vivo, rendering potentially harmful macrophages nonfunctional while the surrounding environment of the implant remains unaffected.


  • Activation of caspase 3 during shear stress‐induced neutrophil apoptosis on biomaterials

    by Matthew S. Shive, William G. Brodbeck, James M. Anderson

    Within the complex environment of an implanted cardiovascular device comprised of dynamic flow and foreign materials, phagocytic neutrophils may be ineffective in combating infection due to cellular responses to shear stress. This may be explained, in part, by our recent reports of apoptosis of biomaterial‐adherent leukocytes induced through exposure to shear stress. Here we utilize a rotating disk system to generate physiologically relevant shear stress levels (0–18 dynes/cm2) at the surface of a polyetherurethane urea (PEUU) and investigate neutrophil intracellular pathways involved in shear‐induced apoptosis. In situ detection of activated caspases, the enzymatic mediators of the apoptosis cascade, showed qualitatively that these proteases participate in shear‐induced apoptosis and are activated in a shear‐dependent manner. The involvement of caspase 3 was confirmed through immunoprecipitation and immunoblotting of extracted neutrophil proteins. Comparative studies with neutrophils adherent under static conditions demonstrated time‐dependent activation of caspases in TNF‐α/cycloheximide‐induced apoptosis, for which caspase‐3 also was implicated. These findings are the first steps toward elucidation of the mechanisms behind the inappropriate induction of apoptosis by adhesion to biomaterials, which may contribute to the development and persistence of device‐related infections. ©2002 Wiley Periodicals, Inc. J Biomed Mater Res 62: 163–168, 2002


  • BIOMATERIAL SURFACE CHEMISTRY DICTATES ADHERENT MONOCYTE/MACROPHAGE CYTOKINE EXPRESSION IN VITRO

    by W.G. Brodbeck, Y. Nakayama, T. Matsuda, E. Colton, N.P. Ziats, J.M. Anderson