William G. Brodbeck
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
William G. Brodbeck has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Gabriela Voskerician
Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio 44106
2 shared publicationsMatthew S. Shive
Departments of *Pathology and ‡Biomedical Engineering, Case Western Reserve University, Cleveland, OH 44139;§ Department of Bioengineering, National Cardiovascular Center, Osaka 562-0025, Japan; and ¶Department of Biomedical Engineering, Kyushu University, Fukuoka 812-8482, Japan
2 shared publicationsNicholas P. Ziats
Department of Pathology, Case Western Reserve University, Cleveland, Ohio 44106
2 shared publicationsTakehisa Matsuda
Department of Biomedical Engineering, Kyushu University, Fukuoka, Japan
2 shared publicationsWilliam G. Brodbeck
Department of Pathology, Case Western Reserve University, Cleveland, Ohio 44106, USA
2 shared publicationsYasuhide Nakayama
Department of Bioengineering, National Cardiovascular Center, Osaka, Japan
2 shared publications
Latest Publications
- 1 August 2003
- Published by Springer Nature in Journal of Materials Science: Materials in Medicine
- Vol. 14 (8) , 671-675
Effects of adsorbed heat labile serum proteins and fibrinogen on adhesion and apoptosis of monocytes/macrophages on biomaterials
A previously established human monocyte culture protocol was used to determine the effects of varying adsorbed proteins on monocyte/macrophage adhesion and survival on dimethyl-silane (DM) or RGD...
- 1 August 2003
- Published by Springer Nature in Journal of Materials Science: Materials in Medicine
- Vol. 14 (8) , 671-675
Effects of adsorbed heat labile serum proteins and fibrinogen on adhesion and apoptosis of monocytes/macrophages on biomaterials
A previously established human monocyte culture protocol was used to determine the effects of varying adsorbed proteins on monocyte/macrophage adhesion and survival on dimethyl-silane (DM) or RGD...
- 31 December 2002
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 64A (2) , 320-329
In vivo leukocyte cytokine mRNA responses to biomaterials are dependent on surface chemistry
An in vivo mouse cage implant system was used to determine whether leukocyte cytokine mRNA responses to implanted biomaterials were dependent on surface chemistry. Surfaces displaying various chemistries (hydrophobic, hydrophilic, anionic, and cationic) were placed into stainless steel cages and implanted subcutaneously. Semiquantitative RT‐PCR analyses revealed that hydrophilic surfaces showed a decreased expression of proinflammatory cytokines, IL‐6 and IL‐8, and pro‐wound healing cytokines, IL‐10 and TGF‐β by adherent cells, and mRNA levels of the proinflammatory cytokine, IL‐1β, and the pro‐wound healing cytokine IL‐13 were decreased in surrounding, exudate cells. Cytokine responses by adherent and exudate cells to hydrophobic, anionic and cationic surfaces were similar and indicative of a strong inflammatory response at the earliest time point followed by a wound healing response at later time points. However, no differences in the types or levels of exudate cells for any of the surfaces or the empty cage at each of the respective time points were observed, indicating their respective biocompatibility. These studies identify hydrophilic surface chemistries as having significant effects on leukocyte cytokine responses in vivo by decreasing the expression of inflammatory and wound healing cytokines by inflammatory cells adherent to the biomaterial as well as present in the surrounding exudate. © 2002 Wiley Periodicals, Inc. J Biomed Mater Res 64A: 320–329, 2003
- 31 December 2002
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 64A (2) , 320-329
In vivo leukocyte cytokine mRNA responses to biomaterials are dependent on surface chemistry
An in vivo mouse cage implant system was used to determine whether leukocyte cytokine mRNA responses to implanted biomaterials were dependent on surface chemistry. Surfaces displaying various chemistries (hydrophobic, hydrophilic, anionic, and cationic) were placed into stainless steel cages and implanted subcutaneously. Semiquantitative RT‐PCR analyses revealed that hydrophilic surfaces showed a decreased expression of proinflammatory cytokines, IL‐6 and IL‐8, and pro‐wound healing cytokines, IL‐10 and TGF‐β by adherent cells, and mRNA levels of the proinflammatory cytokine, IL‐1β, and the pro‐wound healing cytokine IL‐13 were decreased in surrounding, exudate cells. Cytokine responses by adherent and exudate cells to hydrophobic, anionic and cationic surfaces were similar and indicative of a strong inflammatory response at the earliest time point followed by a wound healing response at later time points. However, no differences in the types or levels of exudate cells for any of the surfaces or the empty cage at each of the respective time points were observed, indicating their respective biocompatibility. These studies identify hydrophilic surface chemistries as having significant effects on leukocyte cytokine responses in vivo by decreasing the expression of inflammatory and wound healing cytokines by inflammatory cells adherent to the biomaterial as well as present in the surrounding exudate. © 2002 Wiley Periodicals, Inc. J Biomed Mater Res 64A: 320–329, 2003
- Open Access
- 16 July 2002
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 99 (16) , 10287-10292
Biomaterial adherent macrophage apoptosis is increased by hydrophilic and anionic substratesinvivo
Anin vivorat cage implant system was used to identify potential surface chemistries that prevent failure of implanted biomedical devices and prostheses by limiting monocyte adhesion and macrophage fusion into foreign-body giant cells while inducing adherent-macrophage apoptosis. Hydrophobic, hydrophilic, anionic, and cationic surfaces were used for implantation. Analysis of the exudate surrounding the materials revealed no differences between surfaces in the types or levels of cells present. Conversely, the proportion of adherent cells undergoing apoptosis was increased significantly on anionic and hydrophilic surfaces (46 ± 3.7 and 57 ± 5.0%, respectively) when compared with the polyethylene terephthalate base surface. Additionally, hydrophilic and anionic substrates provided decreased rates of monocyte/macrophage adhesion and fusion. These studies demonstrate that biomaterial-adherent cells undergo material-dependent apoptosisin vivo, rendering potentially harmful macrophages nonfunctional while the surrounding environment of the implant remains unaffected.
- 16 July 2002
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 99 (16) , 10287-10292
Open AccessBiomaterial adherent macrophage apoptosis is increased by hydrophilic and anionic substratesinvivo
Anin vivorat cage implant system was used to identify potential surface chemistries that prevent failure of implanted biomedical devices and prostheses by limiting monocyte adhesion and macrophage fusion into foreign-body giant cells while inducing adherent-macrophage apoptosis. Hydrophobic, hydrophilic, anionic, and cationic surfaces were used for implantation. Analysis of the exudate surrounding the materials revealed no differences between surfaces in the types or levels of cells present. Conversely, the proportion of adherent cells undergoing apoptosis was increased significantly on anionic and hydrophilic surfaces (46 ± 3.7 and 57 ± 5.0%, respectively) when compared with the polyethylene terephthalate base surface. Additionally, hydrophilic and anionic substrates provided decreased rates of monocyte/macrophage adhesion and fusion. These studies demonstrate that biomaterial-adherent cells undergo material-dependent apoptosisin vivo, rendering potentially harmful macrophages nonfunctional while the surrounding environment of the implant remains unaffected.
- 8 July 2002
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 62 (2) , 163-168
Activation of caspase 3 during shear stress‐induced neutrophil apoptosis on biomaterials
Within the complex environment of an implanted cardiovascular device comprised of dynamic flow and foreign materials, phagocytic neutrophils may be ineffective in combating infection due to cellular responses to shear stress. This may be explained, in part, by our recent reports of apoptosis of biomaterial‐adherent leukocytes induced through exposure to shear stress. Here we utilize a rotating disk system to generate physiologically relevant shear stress levels (0–18 dynes/cm2) at the surface of a polyetherurethane urea (PEUU) and investigate neutrophil intracellular pathways involved in shear‐induced apoptosis. In situ detection of activated caspases, the enzymatic mediators of the apoptosis cascade, showed qualitatively that these proteases participate in shear‐induced apoptosis and are activated in a shear‐dependent manner. The involvement of caspase 3 was confirmed through immunoprecipitation and immunoblotting of extracted neutrophil proteins. Comparative studies with neutrophils adherent under static conditions demonstrated time‐dependent activation of caspases in TNF‐α/cycloheximide‐induced apoptosis, for which caspase‐3 also was implicated. These findings are the first steps toward elucidation of the mechanisms behind the inappropriate induction of apoptosis by adhesion to biomaterials, which may contribute to the development and persistence of device‐related infections. ©2002 Wiley Periodicals, Inc. J Biomed Mater Res 62: 163–168, 2002
- 8 July 2002
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 62 (2) , 163-168
Activation of caspase 3 during shear stress‐induced neutrophil apoptosis on biomaterials
Within the complex environment of an implanted cardiovascular device comprised of dynamic flow and foreign materials, phagocytic neutrophils may be ineffective in combating infection due to cellular responses to shear stress. This may be explained, in part, by our recent reports of apoptosis of biomaterial‐adherent leukocytes induced through exposure to shear stress. Here we utilize a rotating disk system to generate physiologically relevant shear stress levels (0–18 dynes/cm2) at the surface of a polyetherurethane urea (PEUU) and investigate neutrophil intracellular pathways involved in shear‐induced apoptosis. In situ detection of activated caspases, the enzymatic mediators of the apoptosis cascade, showed qualitatively that these proteases participate in shear‐induced apoptosis and are activated in a shear‐dependent manner. The involvement of caspase 3 was confirmed through immunoprecipitation and immunoblotting of extracted neutrophil proteins. Comparative studies with neutrophils adherent under static conditions demonstrated time‐dependent activation of caspases in TNF‐α/cycloheximide‐induced apoptosis, for which caspase‐3 also was implicated. These findings are the first steps toward elucidation of the mechanisms behind the inappropriate induction of apoptosis by adhesion to biomaterials, which may contribute to the development and persistence of device‐related infections. ©2002 Wiley Periodicals, Inc. J Biomed Mater Res 62: 163–168, 2002