CRChristoph Runte

Christoph Runte

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Christoph Runte has a total of 25 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Stereoscopic Imaging of Craniofacial Malformations

    by Christoph Runte, Markus Dekiff, Dieter Dirksen

  • Prevention and Treatment of Deformational Cephaly

    by Helena Sophie Kriege, Christoph Runte, Ulrich Meyer, Dieter Dirksen

  • Open Access

    Symmetry and Aesthetics in Dentistry

    by Christoph Runte, Dieter Dirksen

    Animal bodies in general and faces in particular show mirror symmetry with respect to the median-sagittal plane, with exceptions rarely occurring. Bilateral symmetry to the median sagittal plane of the body also evolved very early. From an evolutionary point of view, it should therefore have fundamental advantages, e.g., more effective locomotion and chewing abilities. On the other hand, the recognition of bilaterally symmetric patterns is an important module in our visual perception. In particular, the recognition of faces with different spatial orientations and their identification is strongly related to the recognition of bilateral symmetry. Maxillofacial surgery and Dentistry affect effective masticatory function and perceived symmetry of the lower third of the face. Both disciplines have the ability to eliminate or mitigate asymmetries with respect to form and function. In our review, we will demonstrate symmetric structures from single teeth to the whole face. We will further describe different approaches to quantify cranial, facial and dental asymmetries by using either landmarks or 3D surface models. Severe facial asymmetries are usually caused by malformations such as hemifacial hyperplasia, injury or other diseases such as Noma or head and neck cancer. This could be an important sociobiological reason for a correlation between asymmetry and perceived disfigurement. The aim of our review is to show how facial symmetry and attractiveness are related and in what way dental and facial structures and the symmetry of their shape and color influence aesthetic perception. We will further demonstrate how modern technology can be used to improve symmetry in facial prostheses and maxillofacial surgery.


  • Aspects of Facial Esthetics and Disfigurement

    by Christoph Runte, Dieter Dirksen

  • Computer-aided design of facial prostheses by means of 3D-data acquisition and following symmetry analysis

    by Sophia Bockey, Philipp Berssenbrügge, Dieter Dirksen, Kai Wermker, Martin Klein, Christoph Runte


  • Measured symmetry of facial 3D shape and perceived facial symmetry and attractiveness before and after orthognathic surgery

    by Julia Ostwald, Philipp Berssenbrügge, Dieter Dirksen, Christoph Runte, Kai Wermker, Johannes Kleinheinz, Susanne Jung


    • 18 June 2002
      • Vol. 15  (3) , 254-8

    Spectral analysis of /s/ sound with changing angulation of the maxillary central incisors.

    by Christoph Runte, Djafar Tawana, Dieter Dirksen, Bettina Runte, Antoinette Lamprecht-Dinnesen, Friedhelm Bollmann, Eberhard Seifert, Gholamreza Danesh

    The aim of the study was to measure the influence of the maxillary central incisors free from adaptation phenomena using spectral analysis. The maxillary dentures of 18 subjects were duplicated. The central incisors were fixed in a pivoting appliance so that their position could be changed from labial to palatal direction. A mechanical push/pull cable enabled the incisor section to be handled extraorally. Connected to the control was a sound generator producing a sinus wave whose frequency was related to the central incisor angulation. This acoustic signal was recorded on one channel of a digital tape recorder. After calibration of the unit, the denture duplicate was inserted into the subject's mouth, and the signal of the /s/ sounds subsequently produced by the subject was recorded on the second channel during alteration of the inclination angle simultaneously with the generator signal. Spectral analysis was performed using a Kay Speech-Lab 4300B. Labial displacement in particular produced significant changes in spectral characteristics, with the lower boundary frequency of the /s/ sound being raised and the upper boundary frequency being reduced. Maxillary incisor position influences /s/ sound production. Displacement of the maxillary incisors must be considered a cause of immediate changes in /s/ sound distortion. Therefore, denture teeth should be placed in the original tooth position as accurately as possible. Our results also indicate that neuromuscular reactions are more important for initial speech sound distortions than are aerodynamic changes in the anterior speech sound-producing areas.


    • 16 April 2002
      • Vol. 15  (2) , 129-32

    Optical data acquisition for computer-assisted design of facial prostheses.

    by Christoph Runte, Dieter Dirksen, Holger Deleré, Carsten Thomas, Bettina Runte, Ulrich Meyer, Gert Von Bally, Friedhelm Bollmann

    The conventional impression technique for manufacturing facial prostheses has the disadvantage of deforming the soft tissues because of the tension caused by the impression material, as well as causing discomfort to the patient. The purpose of this study was to establish a system that allows contact-free reproduction of the facial surface combined with computer-assisted design and fabrication of facial prostheses. Three-dimensional data of the facial surface were obtained using an optical acquisition system based on the method of phase-measuring profilometry. A sensor head with a fringe projector and two CCD cameras for photogrammetric triangulation were used in connection with a PC for measurement control and data evaluation. Software for computer-assisted design of the facial surface to be reconstructed was developed. A prototype facial prosthesis was fabricated using stereolithography. The system was tested using a modified puppet head. First clinical tests were performed with a patient who had undergone maxillofacial surgery including the resection of one eye. Three-dimensional data acquisition and imaging allow visualization of a whole face without causing tension or neuromuscular reaction. As surface brightness is also part of the digital model, it is even more realistic than a plaster cast. The stereolithographic object showed good marginal fit and satisfactory shape. The presented technique allows three-dimensional data reproduction of the facial surface, computer-assisted design of a facial prosthesis, and transfer to a rapid prototyping unit. The system has obvious advantages over conventional impression techniques. Further clinical trials are planned to evaluate the clinical success of the technique.


  • The influence of maxillary central incisor position in complete dentures on /s/ sound production

    by Christoph Runte, Michael Lawerino, Dieter Dirksen, Friedhelm Bollmann, Antoinette Lamprecht-Dinnesen, Eberhard Seifert