Robert McDermott
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Robert McDermott has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
John Clarke
Materials Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, CA 94720; and Departments of †Physics and ¶Chemistry, University of California, Berkeley, CA 94720
2 shared publicationsSeungKyun Lee
Materials Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, CA 94720; and Departments of †Physics and ¶Chemistry, University of California, Berkeley, CA 94720
2 shared publicationsAlexander Pines
Materials Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, CA 94720; and Departments of †Physics and ¶Chemistry, University of California, Berkeley, CA 94720
1 shared publication- Andreas Trabesinger
Nature Physics, https://www.nature.com/naturephysics
1 shared publication Bennie Ten Haken
Materials Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, CA 94720; and Departments of †Physics and ¶Chemistry, University of California, Berkeley, CA 94720
1 shared publicationH. M. Cho
Univ. of California/Berkeley and Lawrence Berkeley National Lab. (United States)
1 shared publication
Latest Publications
- Open Access
- 12 May 2004
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 101 (21) , 7857-7861
Microtesla MRI with a superconducting quantum interference device
MRI scanners enable fast, noninvasive, and high-resolution imaging of organs and soft tissue. The images are reconstructed from NMR signals generated by nuclear spins that precess in a static magnetic fieldB0in the presence of magnetic field gradients. Most clinical MRI scanners operate at a magnetic fieldB0= 1.5 T, corresponding to a proton resonance frequency of 64 MHz. Because these systems rely on large superconducting magnets, they are costly and demanding of infrastructure. On the other hand, low-field imagers have the potential to be less expensive, less confining, and more mobile. The major obstacle is the intrinsically low sensitivity of the low-field NMR experiment. Here, we show that prepolarization of the nuclear spins and detection with a superconducting quantum interference device (SQUID) yield a signal that is independent ofB0, allowing acquisition of high-resolution MRIs in microtesla fields. Reduction of the strength of the measurement field eliminates inhomogeneous broadening of the NMR lines, resulting in enhanced signal-to-noise ratio and spatial resolution for a fixed strength of the magnetic field gradients used to encode the image. We present high-resolution images of phantoms and other samples andT1-weighted contrast images acquired in highly inhomogeneous magnetic fields of 132 μT; here,T1is the spin-lattice relaxation time. These techniques could readily be adapted to existing multichannel SQUID systems used for magnetic source imaging of brain signals. Further potential applications include low-cost systems for tumor screening and imaging peripheral regions of the body.
- 12 May 2004
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 101 (21) , 7857-7861
Open AccessMicrotesla MRI with a superconducting quantum interference device
MRI scanners enable fast, noninvasive, and high-resolution imaging of organs and soft tissue. The images are reconstructed from NMR signals generated by nuclear spins that precess in a static magnetic fieldB0in the presence of magnetic field gradients. Most clinical MRI scanners operate at a magnetic fieldB0= 1.5 T, corresponding to a proton resonance frequency of 64 MHz. Because these systems rely on large superconducting magnets, they are costly and demanding of infrastructure. On the other hand, low-field imagers have the potential to be less expensive, less confining, and more mobile. The major obstacle is the intrinsically low sensitivity of the low-field NMR experiment. Here, we show that prepolarization of the nuclear spins and detection with a superconducting quantum interference device (SQUID) yield a signal that is independent ofB0, allowing acquisition of high-resolution MRIs in microtesla fields. Reduction of the strength of the measurement field eliminates inhomogeneous broadening of the NMR lines, resulting in enhanced signal-to-noise ratio and spatial resolution for a fixed strength of the magnetic field gradients used to encode the image. We present high-resolution images of phantoms and other samples andT1-weighted contrast images acquired in highly inhomogeneous magnetic fields of 132 μT; here,T1is the spin-lattice relaxation time. These techniques could readily be adapted to existing multichannel SQUID systems used for magnetic source imaging of brain signals. Further potential applications include low-cost systems for tumor screening and imaging peripheral regions of the body.
- 22 February 2002
- Published by SPIE-Intl Soc Optical Eng
- Vol. 4576, 122-126
Superconducting quantum interference device detection of magnetically tagged micro-organisms
A fast and versatile technique has been developed for detecting small quantities of specific microorganisms or molecules with high specificity. The target analytes are bound to a substrate and placed in the measurement cell of a microscope based on a high-transition temperature Superconducting Quantum Interference Device (SQUID). A solution containing nanometer-size magnetite particles, coated with antibodies specific to the target, is added. The particles, which bind to the target via the antibody- antigen interaction, are superparamagnetic with a Neel relaxation time of ~1s. A pulsed magnetic field aligns the dipole moments, and the SQUID measures the magnetic relaxation signal when the field is turned off. Unbound magnetic particles relax rapidly (~15microsecond(s) ) by Brownian rotation and are not detected. On the other hand, particles bound to targets cannot rotate and instead relax slowly by the Neel mechanism. As a result, only bound particles contribute to the signal, allowing for quantification of the number of targets present without the need for a wash step. The current system can detect as few as 2000 magnetic particles. This technique could be used to detect a wide range of bacteria, viruses, and molecules, with potential applications in the food industry, clinical settings, or research laboratories.
- 22 February 2002
- Published by SPIE-Intl Soc Optical Eng
- Vol. 4576, 122-126
Superconducting quantum interference device detection of magnetically tagged micro-organisms
A fast and versatile technique has been developed for detecting small quantities of specific microorganisms or molecules with high specificity. The target analytes are bound to a substrate and placed in the measurement cell of a microscope based on a high-transition temperature Superconducting Quantum Interference Device (SQUID). A solution containing nanometer-size magnetite particles, coated with antibodies specific to the target, is added. The particles, which bind to the target via the antibody- antigen interaction, are superparamagnetic with a Neel relaxation time of ~1s. A pulsed magnetic field aligns the dipole moments, and the SQUID measures the magnetic relaxation signal when the field is turned off. Unbound magnetic particles relax rapidly (~15microsecond(s) ) by Brownian rotation and are not detected. On the other hand, particles bound to targets cannot rotate and instead relax slowly by the Neel mechanism. As a result, only bound particles contribute to the signal, allowing for quantification of the number of targets present without the need for a wash step. The current system can detect as few as 2000 magnetic particles. This technique could be used to detect a wide range of bacteria, viruses, and molecules, with potential applications in the food industry, clinical settings, or research laboratories.