Daniel A. Low
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Daniel A. Low has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
Sasa Mutic
5 shared publicationsJames A. Purdy
Division of Radiation Oncology, Mallinckrodt Institute of Radiology, Washington University Medical Center, St. Louis, MO, USA
3 shared publicationsJames F. Dempsey
3 shared publicationsJerry Markman
3 shared publicationsB.M. White
University of California, Los Angeles, CA
2 shared publicationsE. Mark Haacke
2 shared publications
Latest Publications
- 1 October 2011
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 81 (2) , S816
Comparison of 4D-PET Gating Methods with Regards to Determining Internal Target Volumes of Mobile Lung Tumors
- 1 October 2011
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 81 (2) , S816
Comparison of 4D-PET Gating Methods with Regards to Determining Internal Target Volumes of Mobile Lung Tumors
- 1 June 2011
- Published by Wiley in Medical Physics
- Vol. 38 (6) , 3374
SU-C-110-03: Utility of Maximum Intensity Projections of Gated PET Images in Determining Internal Target Volumes of Moving Lung Tumors: A Phantom Study
- 1 June 2011
- Published by Wiley in Medical Physics
- Vol. 38 (6) , 3374
SU-C-110-03: Utility of Maximum Intensity Projections of Gated PET Images in Determining Internal Target Volumes of Moving Lung Tumors: A Phantom Study
- 1 November 2010
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 78 (3) , S833-S834
Dynamic Jaws and Dynamic Couch Treatment Planning on Helical Tomotherapy for Esophageal Cancer
- 1 November 2010
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 78 (3) , S833-S834
Dynamic Jaws and Dynamic Couch Treatment Planning on Helical Tomotherapy for Esophageal Cancer
- 1 November 2009
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 75 (3) , S724
Evaluation of Treatment Plan Quality for Single Arc IMRT
- 1 November 2009
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 75 (3) , S724
Evaluation of Treatment Plan Quality for Single Arc IMRT
- 24 June 2003
- Published by Wiley in Medical Physics
- Vol. 30 (7) , 1706-1711
Ionization chamber volume averaging effects in dynamic intensity modulated radiation therapy beams
The commercial cylindrical ionization chamber ionization integration accuracy of dynamically moving fields was evaluated. The ionization chambers were exposed to long (14 cm), narrow (0.6, 1.0, 2.0, and 4.0 cm) 6 MV and 18 MV fields. Rather than rely on the linear accelerator to reproducibly scan across the chamber, the chambers were scanned beneath fixed portals. A water‐equivalent phantom was constructed with cavities that matched the chambers and placed on a computer‐controlled one‐dimensional table. Computer‐controlled electrometers were utilized in continuous charge integrate mode, with 10 samples of the charge, along with time stamps, acquired for each chamber location. A reference chamber was placed just beneath the linear accelerator jaws to adjust for variations in linear accelerator dose rate. The scan spatial resolution was selected to adequately sample regions of steep dose gradient and second spatial derivative (curvature). A fixed measurement in a field was used to normalize the profiles to absolute chamber response. Three ionization chambers were tested, a microchamber a Farmer chamber and a waterproof scanning chamber The larger chambers exhibited severe under‐response at the small field's centers, but all of the chambers, independent of orientation, accurately integrated the ionization across the scanned portal. This indicates that the tested ionization chambers provide accurate integrated charges in regions of homogeneous dose regions. Partial integration (less than the field width plus the chamber length plus 2 cm), yielded integration errors of greater than 1% and 2% for 6 MV and 18 MV, respectively, with errors for the Farmer chamber of greater than 10% even for the 4 cm wide field.
- 24 June 2003
- Published by Wiley in Medical Physics
- Vol. 30 (7) , 1706-1711
Ionization chamber volume averaging effects in dynamic intensity modulated radiation therapy beams
The commercial cylindrical ionization chamber ionization integration accuracy of dynamically moving fields was evaluated. The ionization chambers were exposed to long (14 cm), narrow (0.6, 1.0, 2.0, and 4.0 cm) 6 MV and 18 MV fields. Rather than rely on the linear accelerator to reproducibly scan across the chamber, the chambers were scanned beneath fixed portals. A water‐equivalent phantom was constructed with cavities that matched the chambers and placed on a computer‐controlled one‐dimensional table. Computer‐controlled electrometers were utilized in continuous charge integrate mode, with 10 samples of the charge, along with time stamps, acquired for each chamber location. A reference chamber was placed just beneath the linear accelerator jaws to adjust for variations in linear accelerator dose rate. The scan spatial resolution was selected to adequately sample regions of steep dose gradient and second spatial derivative (curvature). A fixed measurement in a field was used to normalize the profiles to absolute chamber response. Three ionization chambers were tested, a microchamber a Farmer chamber and a waterproof scanning chamber The larger chambers exhibited severe under‐response at the small field's centers, but all of the chambers, independent of orientation, accurately integrated the ionization across the scanned portal. This indicates that the tested ionization chambers provide accurate integrated charges in regions of homogeneous dose regions. Partial integration (less than the field width plus the chamber length plus 2 cm), yielded integration errors of greater than 1% and 2% for 6 MV and 18 MV, respectively, with errors for the Farmer chamber of greater than 10% even for the 4 cm wide field.
- Top Cited Papers
- 30 May 2003
- Published by Wiley in Medical Physics
- Vol. 30 (6) , 1254-1263
A method for the reconstruction of four‐dimensional synchronized CT scans acquired during free breathing
Breathing motion is a significant source of error in radiotherapy treatment planning for the thorax and upper abdomen. Accounting for breathing motion has a profound effect on the size of conformal radiation portals employed in these sites. Breathing motion also causes artifacts and distortions in treatment planning computed tomography (CT) scans acquired during free breathing and also causes a breakdown of the assumption of the superposition of radiation portals in intensity‐modulated radiation therapy, possibly leading to significant dose delivery errors. Proposed voluntary and involuntary breath‐hold techniques have the potential for reducing or eliminating the effects of breathing motion, however, they are limited in practice, by the fact that many lung cancer patients cannot tolerate holding their breath. We present an alternative solution to accounting for breathing motion in radiotherapy treatment planning, where multislice CT scans are collected simultaneously with digital spirometry over many free breathing cycles to create a four‐dimensional (4‐D) image set, where tidal lung volume is the additional dimension. An analysis of this 4‐D data leads to methods for digital‐spirometry, based elimination or accounting of breathing motion artifacts in radiotherapy treatment planning for free breathing patients. The 4‐D image set is generated by sorting free‐breathing multislice CT scans according to user‐defined tidal‐volume bins. A multislice CT scanner is operated in the ciné mode, acquiring 15 scans per couch position, while the patient undergoes simultaneous digital‐spirometry measurements. The spirometry is used to retrospectively sort the CT scans by their correlated tidal lung volume within the patient's normal breathing cycle. This method has been prototyped using data from three lung cancer patients. The actual tidal lung volumes agreed with the specified bin volumes within standard deviations ranging between 22 and 33 An analysis of sagittal and coronal images demonstrated relatively small (<1 cm) motion artifacts along the diaphragm, even for tidal volumes where the rate of breathing motion is greatest. While still under development, this technology has the potential for revolutionizing the radiotherapy treatment planning for the thorax and upper abdomen.
- 30 May 2003
- Published by Wiley in Medical Physics
- Vol. 30 (6) , 1254-1263
Top Cited PapersA method for the reconstruction of four‐dimensional synchronized CT scans acquired during free breathing
Breathing motion is a significant source of error in radiotherapy treatment planning for the thorax and upper abdomen. Accounting for breathing motion has a profound effect on the size of conformal radiation portals employed in these sites. Breathing motion also causes artifacts and distortions in treatment planning computed tomography (CT) scans acquired during free breathing and also causes a breakdown of the assumption of the superposition of radiation portals in intensity‐modulated radiation therapy, possibly leading to significant dose delivery errors. Proposed voluntary and involuntary breath‐hold techniques have the potential for reducing or eliminating the effects of breathing motion, however, they are limited in practice, by the fact that many lung cancer patients cannot tolerate holding their breath. We present an alternative solution to accounting for breathing motion in radiotherapy treatment planning, where multislice CT scans are collected simultaneously with digital spirometry over many free breathing cycles to create a four‐dimensional (4‐D) image set, where tidal lung volume is the additional dimension. An analysis of this 4‐D data leads to methods for digital‐spirometry, based elimination or accounting of breathing motion artifacts in radiotherapy treatment planning for free breathing patients. The 4‐D image set is generated by sorting free‐breathing multislice CT scans according to user‐defined tidal‐volume bins. A multislice CT scanner is operated in the ciné mode, acquiring 15 scans per couch position, while the patient undergoes simultaneous digital‐spirometry measurements. The spirometry is used to retrospectively sort the CT scans by their correlated tidal lung volume within the patient's normal breathing cycle. This method has been prototyped using data from three lung cancer patients. The actual tidal lung volumes agreed with the specified bin volumes within standard deviations ranging between 22 and 33 An analysis of sagittal and coronal images demonstrated relatively small (<1 cm) motion artifacts along the diaphragm, even for tidal volumes where the rate of breathing motion is greatest. While still under development, this technology has the potential for revolutionizing the radiotherapy treatment planning for the thorax and upper abdomen.
- 1 July 2002
- Published by Elsevier in Seminars in Radiation Oncology
- Vol. 12 (3) , 219-228
Quality assurance of intensity-modulated radiotherapy
- 1 July 2002
- Published by Elsevier in Seminars in Radiation Oncology
- Vol. 12 (3) , 219-228
Quality assurance of intensity-modulated radiotherapy
- 1 June 2002
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 53 (2) , 443-452
Toward automated quality assurance for intensity- modulated radiation therapy
- 1 June 2002
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 53 (2) , 443-452
Toward automated quality assurance for intensity- modulated radiation therapy
- 1 April 2002
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 52 (5) , 1400-1406
Applicator-guided intensity-modulated radiation therapy
- 1 April 2002
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 52 (5) , 1400-1406
Applicator-guided intensity-modulated radiation therapy
- 8 August 2000
- Published by Wiley in Medical Physics
- Vol. 27 (8) , 1814-1817
Noise in polymer gel measurements using MRI
With the development of conformal radiotherapy, particularly intensity modulated radiation therapy (IMRT), there is a clear need for multidimensional dosimeters. A commercial polymerizing gel, BANG-2 gel (MGS Research, Inc., Guilford, CT), has recently been developed that shows potential as a multi-dimensional dosimeter. This study investigates and characterizes the noise and magnetic resonance (MR) artifacts from imaging BANG-2 gels. Seven cylindrical vials (4 cm diam, 20 cm length) were irradiated end on in a water bath and read using MRI (B0=1.5 T, TE=20 ms/100 ms, TR=3000 ms). The gel calibration compared the measured depth-dose distributions in water against the change in solvent-proton R2 relaxivity of the gel. A larger vial (13 cm diam, 14 cm length) was also irradiated to test the calibration accuracy in a vial of sufficient volume for dose distribution measurements. The calibration curve proved accurate to within 1.3% in determining the depth dose measured by the larger vial. An investigation of the voxel-to-voxel (IXIX 3 mm3) noise and sensitivity response curve showed that the voxel-to-voxel variation dominated the dose measurement uncertainty. The voxel-to-voxel standard deviation ranged from 0.2 Gy for the unirradiated gel to 0.7 Gy at 20 Gy. Slice-to-slice R2 magnitude deviations were also observed corresponding to 0.2 Gy. These variations limited the overall accuracy of the gel dose measurements and warrant an investigation of more accurate MR readout sequences.
- 8 August 2000
- Published by Wiley in Medical Physics
- Vol. 27 (8) , 1814-1817
Noise in polymer gel measurements using MRI
With the development of conformal radiotherapy, particularly intensity modulated radiation therapy (IMRT), there is a clear need for multidimensional dosimeters. A commercial polymerizing gel, BANG-2 gel (MGS Research, Inc., Guilford, CT), has recently been developed that shows potential as a multi-dimensional dosimeter. This study investigates and characterizes the noise and magnetic resonance (MR) artifacts from imaging BANG-2 gels. Seven cylindrical vials (4 cm diam, 20 cm length) were irradiated end on in a water bath and read using MRI (B0=1.5 T, TE=20 ms/100 ms, TR=3000 ms). The gel calibration compared the measured depth-dose distributions in water against the change in solvent-proton R2 relaxivity of the gel. A larger vial (13 cm diam, 14 cm length) was also irradiated to test the calibration accuracy in a vial of sufficient volume for dose distribution measurements. The calibration curve proved accurate to within 1.3% in determining the depth dose measured by the larger vial. An investigation of the voxel-to-voxel (IXIX 3 mm3) noise and sensitivity response curve showed that the voxel-to-voxel variation dominated the dose measurement uncertainty. The voxel-to-voxel standard deviation ranged from 0.2 Gy for the unirradiated gel to 0.7 Gy at 20 Gy. Slice-to-slice R2 magnitude deviations were also observed corresponding to 0.2 Gy. These variations limited the overall accuracy of the gel dose measurements and warrant an investigation of more accurate MR readout sequences.