Charles W. Haldeman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Charles W. Haldeman has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Michael G. Dunn
Department of Orthopaedic Surgery, Rutgers Biomedical and Health Sciences-Robert Wood Johnson Medical School , New Brunswick, New Jersey
8 shared publications - Randall M. Mathison
Gas Turbine Laboratory, The Ohio State University, Columbus, OH 43235
8 shared publications Michael G. Dunn
Ohio State University, Columbus, OH
5 shared publications- Brian R. Green
GE Aviation, Cincinnati, OH 45215
3 shared publications John W. Barter
General Electric Aircraft Engines, Cincinnati, OH
3 shared publicationsRobert F. Bergholz
General Electric Transportation, Cincinnati, OH
3 shared publications
Latest Publications
- 8 November 2012
- Published by Wiley in Journal of Turbomachinery
- Vol. 135 (2) , 021028
Heat Transfer for the Film-Cooled Vane of a 1-1/2 Stage High-Pressure Transonic Turbine—Part II: Effect of Cooling Variation on the Vane Airfoil and Inner End Wall
The impact of film cooling on heat transfer is investigated for the high-pressure vane of a 1-1/2 stage high-pressure turbine operating at design corrected conditions. Cooling is supplied through three independently controllable circuits to holes in the inner and outer end wall, vane leading edge showerhead, and the pressure and suction surfaces of the airfoil, in addition to vane trailing edge slots. Four different overall cooling flow rates are investigated and one cooling circuit is varied independently. All results reported in this part of the paper are for a radial inlet temperature profile, one of the four profiles reported in part I of this paper. Part I describes the experimental setup, data quality, influence of inlet temperature profile, and influence of cooling when compared to a solid vane. This part of the paper shows that the addition of coolant reduces airfoil Stanton number by up to 60%. The largest reductions due to cooling are observed close to the inner end wall because the coolant to the majority of the vane is supplied by a plenum at the inside diameter. While the introduction of cooling has a significant impact on Stanton number, the impact of changing coolant flow rates is only observed for gauges near 5% span and on the inner end wall. This indicates that very little of the increased coolant mass flow reaches all the way to 90% span and the majority of the additional mass flow is injected into the core flow near the plenum. Turning off the vane outer cooling circuit that supplies coolant to the outer end wall holes, vane trailing edge slots, and three rows of holes on the pressure surface of the airfoil, has a local impact on Stanton number. Changes downstream of the holes on the airfoil pressure surface indicate that internal heat transfer from the coolant flowing inside the vane is important to the external heat transfer, suggesting that a conjugate heat-transfer solution may be required to achieve good external heat-transfer predictions in this area. Measurements on the inner end wall show that temperature reduction in the vane wake due to the trailing edge cooling is important to many points downstream of the vane.
- 8 November 2012
- Published by Wiley in Journal of Turbomachinery
- Vol. 135 (2) , 021028
Heat Transfer for the Film-Cooled Vane of a 1-1/2 Stage High-Pressure Transonic Turbine—Part II: Effect of Cooling Variation on the Vane Airfoil and Inner End Wall
The impact of film cooling on heat transfer is investigated for the high-pressure vane of a 1-1/2 stage high-pressure turbine operating at design corrected conditions. Cooling is supplied through three independently controllable circuits to holes in the inner and outer end wall, vane leading edge showerhead, and the pressure and suction surfaces of the airfoil, in addition to vane trailing edge slots. Four different overall cooling flow rates are investigated and one cooling circuit is varied independently. All results reported in this part of the paper are for a radial inlet temperature profile, one of the four profiles reported in part I of this paper. Part I describes the experimental setup, data quality, influence of inlet temperature profile, and influence of cooling when compared to a solid vane. This part of the paper shows that the addition of coolant reduces airfoil Stanton number by up to 60%. The largest reductions due to cooling are observed close to the inner end wall because the coolant to the majority of the vane is supplied by a plenum at the inside diameter. While the introduction of cooling has a significant impact on Stanton number, the impact of changing coolant flow rates is only observed for gauges near 5% span and on the inner end wall. This indicates that very little of the increased coolant mass flow reaches all the way to 90% span and the majority of the additional mass flow is injected into the core flow near the plenum. Turning off the vane outer cooling circuit that supplies coolant to the outer end wall holes, vane trailing edge slots, and three rows of holes on the pressure surface of the airfoil, has a local impact on Stanton number. Changes downstream of the holes on the airfoil pressure surface indicate that internal heat transfer from the coolant flowing inside the vane is important to the external heat transfer, suggesting that a conjugate heat-transfer solution may be required to achieve good external heat-transfer predictions in this area. Measurements on the inner end wall show that temperature reduction in the vane wake due to the trailing edge cooling is important to many points downstream of the vane.
- 1 November 2012
- Published by Wiley in Journal of Turbomachinery
- Vol. 135 (2) , 021027
Heat Transfer for the Film-Cooled Vane of a 1-1/2 Stage High-Pressure Transonic Turbine—Part I: Experimental Configuration and Data Review With Inlet Temperature Profile Effects
This paper investigates the vane airfoil and inner endwall heat transfer for a full-scale turbine stage operating at design corrected conditions under the influence of different vane inlet temperature profiles and vane cooling flow rates. The turbine stage is a modern 3D design consisting of a cooled high-pressure vane, an un-cooled high-pressure rotor, and a low-pressure vane. Inlet temperature profiles (uniform, radial, and hot streaks) are created by a passive heat exchanger and can be made circumferentially uniform to within ±5% of the bulk average inlet temperature when desired. The high-pressure vane has full cooling coverage on both the airfoil surface and the inner and outer endwalls. Two circuits supply coolant to the vane, and a third circuit supplies coolant to the rotor purge cavity. All of the cooling circuits are independently controlled. Measurements are performed using double-sided heat-flux gauges located at four spans of the vane airfoil surface and throughout the inner endwall region. Analysis of the heat transfer measured for the uncooled downstream blade row has been reported previously. Part I of this paper describes the operating conditions and data reduction techniques utilized in this analysis, including a novel application of a traditional statistical method to assign confidence limits to measurements in the absence of repeat runs. The impact of Stanton number definition is discussed while analyzing inlet temperature profile shape effects. Comparison of the present data (Build 2) to the data obtained for an uncooled vane (Build 1) clearly illustrates the impact of the cooling flow and its relative effects on both the endwall and airfoils. Measurements obtained for the cooled hardware without cooling applied agree well with the solid airfoil for the airfoil pressure surface but not for the suction surface. Differences on the suction surface are due to flow being ingested on the pressure surface and reinjected on the suction surface when coolant is not supplied for Build 2. Part II of the paper continues this discussion by describing the influence of overall cooling level variation and the influence of the vane trailing edge cooling on the vane heat transfer measurements.
- 1 November 2012
- Published by Wiley in Journal of Turbomachinery
- Vol. 135 (2) , 021027
Heat Transfer for the Film-Cooled Vane of a 1-1/2 Stage High-Pressure Transonic Turbine—Part I: Experimental Configuration and Data Review With Inlet Temperature Profile Effects
This paper investigates the vane airfoil and inner endwall heat transfer for a full-scale turbine stage operating at design corrected conditions under the influence of different vane inlet temperature profiles and vane cooling flow rates. The turbine stage is a modern 3D design consisting of a cooled high-pressure vane, an un-cooled high-pressure rotor, and a low-pressure vane. Inlet temperature profiles (uniform, radial, and hot streaks) are created by a passive heat exchanger and can be made circumferentially uniform to within ±5% of the bulk average inlet temperature when desired. The high-pressure vane has full cooling coverage on both the airfoil surface and the inner and outer endwalls. Two circuits supply coolant to the vane, and a third circuit supplies coolant to the rotor purge cavity. All of the cooling circuits are independently controlled. Measurements are performed using double-sided heat-flux gauges located at four spans of the vane airfoil surface and throughout the inner endwall region. Analysis of the heat transfer measured for the uncooled downstream blade row has been reported previously. Part I of this paper describes the operating conditions and data reduction techniques utilized in this analysis, including a novel application of a traditional statistical method to assign confidence limits to measurements in the absence of repeat runs. The impact of Stanton number definition is discussed while analyzing inlet temperature profile shape effects. Comparison of the present data (Build 2) to the data obtained for an uncooled vane (Build 1) clearly illustrates the impact of the cooling flow and its relative effects on both the endwall and airfoils. Measurements obtained for the cooled hardware without cooling applied agree well with the solid airfoil for the airfoil pressure surface but not for the suction surface. Differences on the suction surface are due to flow being ingested on the pressure surface and reinjected on the suction surface when coolant is not supplied for Build 2. Part II of the paper continues this discussion by describing the influence of overall cooling level variation and the influence of the vane trailing edge cooling on the vane heat transfer measurements.
- 15 July 2011
- Published by Wiley in Journal of Turbomachinery
- Vol. 134 (3) , 031015
Heat Transfer for the Blade of a Cooled Stage and One-Half High-Pressure Turbine—Part II: Independent Influences of Vane Trailing Edge and Purge Cooling
The independent influences of vane trailing edge and purge cooling are studied in detail for a one-and-one-half stage transonic high-pressure turbine operating at design-corrected conditions. This paper builds on the conclusions of Part I, which investigated the combined influence of all cooling circuits. Heat-flux measurements for the airfoil, platform, tip, and root of the turbine blade, as well as the shroud and the vane side of the purge cavity, are used to track the influence of cooling flow. By independently varying the coolant flow rate through the vane trailing edge or purge circuit, the region of influence of each circuit can be isolated. Vane trailing edge cooling is found to create the largest reductions in blade heat transfer. However, much of the coolant accumulates on the blade suction surface and little influence is observed for the pressure surface. In contrast, the purge cooling is able to cause small reductions in heat transfer on both the suction and pressure surfaces of the airfoil. Its region of influence is limited to near the hub, but given that the purge coolant mass flow rate is 1/8 that of the vane trailing edge, it is impressive that any impact is observed at all. The cooling contributions of these two circuits account for nearly all of the cooling reductions observed for all three circuits in Part I, indicating that the vane inner cooling circuit that feeds most of the vane film-cooling holes has little impact on the downstream blade heat transfer. Time-accurate pressure measurements provide further insight into the complex interactions in the purge region that govern purge coolant injection. While the pressures supplying the purge coolant and the overall coolant flow rate remain fairly constant, the interactions of the vane pressure field and the rotor pressure field create moving regions of high pressure and low pressure at the exit of the cavity. This results in pulsing regions of injection and ingestion.
- 15 July 2011
- Published by Wiley in Journal of Turbomachinery
- Vol. 134 (3) , 031015
Heat Transfer for the Blade of a Cooled Stage and One-Half High-Pressure Turbine—Part II: Independent Influences of Vane Trailing Edge and Purge Cooling
The independent influences of vane trailing edge and purge cooling are studied in detail for a one-and-one-half stage transonic high-pressure turbine operating at design-corrected conditions. This paper builds on the conclusions of Part I, which investigated the combined influence of all cooling circuits. Heat-flux measurements for the airfoil, platform, tip, and root of the turbine blade, as well as the shroud and the vane side of the purge cavity, are used to track the influence of cooling flow. By independently varying the coolant flow rate through the vane trailing edge or purge circuit, the region of influence of each circuit can be isolated. Vane trailing edge cooling is found to create the largest reductions in blade heat transfer. However, much of the coolant accumulates on the blade suction surface and little influence is observed for the pressure surface. In contrast, the purge cooling is able to cause small reductions in heat transfer on both the suction and pressure surfaces of the airfoil. Its region of influence is limited to near the hub, but given that the purge coolant mass flow rate is 1/8 that of the vane trailing edge, it is impressive that any impact is observed at all. The cooling contributions of these two circuits account for nearly all of the cooling reductions observed for all three circuits in Part I, indicating that the vane inner cooling circuit that feeds most of the vane film-cooling holes has little impact on the downstream blade heat transfer. Time-accurate pressure measurements provide further insight into the complex interactions in the purge region that govern purge coolant injection. While the pressures supplying the purge coolant and the overall coolant flow rate remain fairly constant, the interactions of the vane pressure field and the rotor pressure field create moving regions of high pressure and low pressure at the exit of the cavity. This results in pulsing regions of injection and ingestion.
- 15 July 2011
- Published by Wiley in Journal of Turbomachinery
- Vol. 134 (3) , 031014
Heat Transfer for the Blade of a Cooled Stage and One-Half High-Pressure Turbine—Part I: Influence of Cooling Variation
Heat-flux measurements are presented for a one-and-one-half stage high-pressure turbine operating at design-corrected conditions with modulated cooling flows in the presence of different inlet temperature profiles. Coolant is supplied from a heavily film-cooled vane and the purge cavity (between the rotor disk and the upstream vane) but not from the rotor blades, which are solid metal. Thin-film heat-flux gauges are located on the uncooled blade pressure and suction surface (at multiple span locations), on the blade tip, on the blade platform, and on the disk and vane sides of the purge cavity. These measurements provide a comprehensive picture of the effect of varying cooling flow rates on surface heat transfer to the turbine blade for uniform and radial inlet temperature profiles. Part I of this paper examines the macroscopic influence of varying all cooling flows together, while Part II investigates the individual regions of influence of the vane outer and purge cooling circuits in more detail. The heat-flux gauges are able to track the cooling flow over the suction surface of the airfoil as it wraps upwards along the base of the airfoil for the uniform vane inlet temperature profile. A similar comparison for the radial profile shows the same coolant behavior but with less pronounced changes. From these comparisons, it is clear that cooling impacts each temperature profile similarly. Nearly all of the cooling influence is limited to the blade suction surface, but small changes are observed for the pressure surface. In addition to the cooling study, a novel method of calculating the adiabatic wall temperature is demonstrated. The derived adiabatic wall temperature distribution shows very similar trends to the Stanton number distribution on the blade.
- 15 July 2011
- Published by Wiley in Journal of Turbomachinery
- Vol. 134 (3) , 031014
Heat Transfer for the Blade of a Cooled Stage and One-Half High-Pressure Turbine—Part I: Influence of Cooling Variation
Heat-flux measurements are presented for a one-and-one-half stage high-pressure turbine operating at design-corrected conditions with modulated cooling flows in the presence of different inlet temperature profiles. Coolant is supplied from a heavily film-cooled vane and the purge cavity (between the rotor disk and the upstream vane) but not from the rotor blades, which are solid metal. Thin-film heat-flux gauges are located on the uncooled blade pressure and suction surface (at multiple span locations), on the blade tip, on the blade platform, and on the disk and vane sides of the purge cavity. These measurements provide a comprehensive picture of the effect of varying cooling flow rates on surface heat transfer to the turbine blade for uniform and radial inlet temperature profiles. Part I of this paper examines the macroscopic influence of varying all cooling flows together, while Part II investigates the individual regions of influence of the vane outer and purge cooling circuits in more detail. The heat-flux gauges are able to track the cooling flow over the suction surface of the airfoil as it wraps upwards along the base of the airfoil for the uniform vane inlet temperature profile. A similar comparison for the radial profile shows the same coolant behavior but with less pronounced changes. From these comparisons, it is clear that cooling impacts each temperature profile similarly. Nearly all of the cooling influence is limited to the blade suction surface, but small changes are observed for the pressure surface. In addition to the cooling study, a novel method of calculating the adiabatic wall temperature is demonstrated. The derived adiabatic wall temperature distribution shows very similar trends to the Stanton number distribution on the blade.
- 27 May 2011
- Published by Wiley in Journal of Turbomachinery
- Vol. 134 (1) , 011016
Temperature Predictions and Comparison With Measurements for the Blade Leading Edge and Platform of a 1 1/2 Stage Transonic HP Turbine
A series of computational predictions generated using FINE/TURBO are compared with data to investigate implementation techniques available for predicting temperature migration through a turbine stage. The experimental results used for comparison are from a one-and-one-half stage turbine operating at design-corrected conditions in a short-duration facility. Measurements of the boundary conditions are used to set up the computational models, and the predicted temperatures are compared with measured fluid temperatures at the blade leading edge and just above the blade platform. Fluid temperature measurements have not previously been available for these locations in a transonic turbine operating at design-corrected conditions, so this represents a novel comparison. Accurate predictions for this short-duration turbine experiment require use of the isothermal wall boundary condition instead of an adiabatic boundary condition and accurate specification of the inlet temperature profile all the way to the wall. Predictions using the harmonic method agree with the temperatures measured for the blade leading edge from 65% to 95% span to within 1% normalized temperature data. Agreement over much of the rest of the leading edge is within 5% of the measured value. Comparisons at 5–10% span and for the blade platform show larger differences up to 10%, which indicates that the flow in this region is not fully captured by the prediction. This is not surprising since the purge cavity and platform leading-edge features present in the experiment are treated as a smooth hub wall in the current simulation. This work represents a step toward the larger goal of accurately predicting surface heat-flux for the complicated environment of an operational engine as it is reproduced in a laboratory setting. The experiment upon which these computations are based includes realistic complications such as one-dimensional and two-dimensional inlet temperature profiles, a heavily film-cooled vane, and purge cooling. While the ultimate goal is to accurately handle all of these features, the current model focuses on the treatment of a subset of experiments performed for a one-dimensional radial inlet temperature profile and no cooling.
- 27 May 2011
- Published by Wiley in Journal of Turbomachinery
- Vol. 134 (1) , 011016
Temperature Predictions and Comparison With Measurements for the Blade Leading Edge and Platform of a 1 1/2 Stage Transonic HP Turbine
A series of computational predictions generated using FINE/TURBO are compared with data to investigate implementation techniques available for predicting temperature migration through a turbine stage. The experimental results used for comparison are from a one-and-one-half stage turbine operating at design-corrected conditions in a short-duration facility. Measurements of the boundary conditions are used to set up the computational models, and the predicted temperatures are compared with measured fluid temperatures at the blade leading edge and just above the blade platform. Fluid temperature measurements have not previously been available for these locations in a transonic turbine operating at design-corrected conditions, so this represents a novel comparison. Accurate predictions for this short-duration turbine experiment require use of the isothermal wall boundary condition instead of an adiabatic boundary condition and accurate specification of the inlet temperature profile all the way to the wall. Predictions using the harmonic method agree with the temperatures measured for the blade leading edge from 65% to 95% span to within 1% normalized temperature data. Agreement over much of the rest of the leading edge is within 5% of the measured value. Comparisons at 5–10% span and for the blade platform show larger differences up to 10%, which indicates that the flow in this region is not fully captured by the prediction. This is not surprising since the purge cavity and platform leading-edge features present in the experiment are treated as a smooth hub wall in the current simulation. This work represents a step toward the larger goal of accurately predicting surface heat-flux for the complicated environment of an operational engine as it is reproduced in a laboratory setting. The experiment upon which these computations are based includes realistic complications such as one-dimensional and two-dimensional inlet temperature profiles, a heavily film-cooled vane, and purge cooling. While the ultimate goal is to accurately handle all of these features, the current model focuses on the treatment of a subset of experiments performed for a one-dimensional radial inlet temperature profile and no cooling.
- 25 May 2011
- Published by Wiley in Journal of Turbomachinery
- Vol. 134 (1) , 011008
Aerodynamics and Heat Transfer for a Cooled One and One-Half Stage High-Pressure Turbine—Part III: Impact of Hot-Streak Characteristics on Blade Row Heat Flux
The influence of hot-streak magnitude and alignment relative to the vane leading edge on blade row heat flux is investigated for a one and one-half stage high-pressure turbine with a film-cooled vane, purge cooling, and uncooled blades. The full-stage turbine is operated at design-corrected conditions. In addition to investigating the impact of different hot-streak characteristics, this study also looks at the interaction of cooling flow with the hot streaks. This paper builds on the investigation of profile migration utilizing temperature measurements presented in Part I and the heat transfer measurements presented in Part II. Hot streaks aligned with the vane midpitch have a greater impact on blade temperatures and heat-flux values than hot streaks aligned with the vane leading edge. The leading edge hot streaks tend to be mixed out over the surface of the vane. The magnitude of the hot streak is observed to have the largest influence on the temperature and heat flux for the downstream blade. Time-accurate measurements confirm these conclusions and indicate that further analysis of the time-accurate data is warranted. Film cooling is found to impact a hot-streak profile in a way similar to that observed for a radial profile. Differences in core to coolant temperature ratio cause the uniform profile to show different coolant effects, but the overall spread of the cooling appears similar.
- 25 May 2011
- Published by Wiley in Journal of Turbomachinery
- Vol. 134 (1) , 011008
Aerodynamics and Heat Transfer for a Cooled One and One-Half Stage High-Pressure Turbine—Part III: Impact of Hot-Streak Characteristics on Blade Row Heat Flux
The influence of hot-streak magnitude and alignment relative to the vane leading edge on blade row heat flux is investigated for a one and one-half stage high-pressure turbine with a film-cooled vane, purge cooling, and uncooled blades. The full-stage turbine is operated at design-corrected conditions. In addition to investigating the impact of different hot-streak characteristics, this study also looks at the interaction of cooling flow with the hot streaks. This paper builds on the investigation of profile migration utilizing temperature measurements presented in Part I and the heat transfer measurements presented in Part II. Hot streaks aligned with the vane midpitch have a greater impact on blade temperatures and heat-flux values than hot streaks aligned with the vane leading edge. The leading edge hot streaks tend to be mixed out over the surface of the vane. The magnitude of the hot streak is observed to have the largest influence on the temperature and heat flux for the downstream blade. Time-accurate measurements confirm these conclusions and indicate that further analysis of the time-accurate data is warranted. Film cooling is found to impact a hot-streak profile in a way similar to that observed for a radial profile. Differences in core to coolant temperature ratio cause the uniform profile to show different coolant effects, but the overall spread of the cooling appears similar.
- 25 May 2011
- Published by Wiley in Journal of Turbomachinery
- Vol. 134 (1) , 011007
Aerodynamics and Heat Transfer for a Cooled One and One-Half Stage High-Pressure Turbine–Part II: Influence of Inlet Temperature Profile on Blade Row and Shroud
Heat flux measurements are presented for the uncooled blades of a one and one-half stage turbine operating at design corrected conditions with a fully cooled upstream vane row and with rotor disk cavity purge flow. This paper highlights the differences in blade heat flux and temperature caused by uniform, radial, and hot streak inlet temperature profiles. A general discussion of temperature profile migration is provided in Part I, and Part III presents data for hot streak magnitudes and alignments. The heat flux and fluid temperature measurements for the blade airfoil, platform, angel wing (near the root), and tip as well as for the stationary outer shroud are influenced by the vane inlet temperature profile. The inlet temperature profile shape can be clearly observed in the blade Stanton number measurements, with the radial and hot streak profiles showing a greater redistribution of energy than the uniform case due to secondary flows. Hot-gas segregation is observed to increase with the strength of the temperature distortion. Measurements for the hot streak profile show a segregation of higher temperature fluid to the pressure surface when compared with a uniform profile. The introduction of vane and purge cooling is found to further accentuate the flow segregation due to coolant migration to the suction surface.
- 25 May 2011
- Published by Wiley in Journal of Turbomachinery
- Vol. 134 (1) , 011007
Aerodynamics and Heat Transfer for a Cooled One and One-Half Stage High-Pressure Turbine–Part II: Influence of Inlet Temperature Profile on Blade Row and Shroud
Heat flux measurements are presented for the uncooled blades of a one and one-half stage turbine operating at design corrected conditions with a fully cooled upstream vane row and with rotor disk cavity purge flow. This paper highlights the differences in blade heat flux and temperature caused by uniform, radial, and hot streak inlet temperature profiles. A general discussion of temperature profile migration is provided in Part I, and Part III presents data for hot streak magnitudes and alignments. The heat flux and fluid temperature measurements for the blade airfoil, platform, angel wing (near the root), and tip as well as for the stationary outer shroud are influenced by the vane inlet temperature profile. The inlet temperature profile shape can be clearly observed in the blade Stanton number measurements, with the radial and hot streak profiles showing a greater redistribution of energy than the uniform case due to secondary flows. Hot-gas segregation is observed to increase with the strength of the temperature distortion. Measurements for the hot streak profile show a segregation of higher temperature fluid to the pressure surface when compared with a uniform profile. The introduction of vane and purge cooling is found to further accentuate the flow segregation due to coolant migration to the suction surface.
- 25 May 2011
- Published by Wiley in Journal of Turbomachinery
- Vol. 134 (1) , 011006
Aerodynamics and Heat Transfer for a Cooled One and One-Half Stage High-Pressure Turbine—Part I: Vane Inlet Temperature Profile Generation and Migration
As controlled laboratory experiments using full-stage turbines are expanded to replicate more of the complicated flow features associated with real engines, it is important to understand the influence of the vane inlet temperature profile on the high-pressure vane and blade heat transfer as well as its interaction with film cooling. The temperature distribution of the incoming fluid governs not only the input conditions to the boundary layer but also the overall fluid migration. Both of these mechanisms have a strong influence on surface heat flux and therefore component life predictions. To better understand the role of the inlet temperature profile, an electrically heated combustor emulator capable of generating uniform, radial, or hot streak temperature profiles at the high-pressure turbine vane inlet has been designed, constructed, and operated over a wide range of conditions. The device is shown to introduce a negligible pressure distortion while generating the inlet temperature conditions for a stage-and-a-half turbine operating at design-corrected conditions. For the measurements described here, the vane is fully cooled and the rotor purge flow is active, but the blades are uncooled. Detailed temperature measurements are obtained at rake locations upstream and downstream of the turbine stage as well as at the leading edge and platform of the blade in order to characterize the inlet temperature profile and its migration. The use of miniature butt-welded thermocouples at the leading edge and on the platform (protruding into the flow) on a rotating blade is a novel method of mapping a temperature profile. These measurements show that the reduction in fluid temperature due to cooling is similar in magnitude for both uniform and radial vane inlet temperature profiles.
- 25 May 2011
- Published by Wiley in Journal of Turbomachinery
- Vol. 134 (1) , 011006
Aerodynamics and Heat Transfer for a Cooled One and One-Half Stage High-Pressure Turbine—Part I: Vane Inlet Temperature Profile Generation and Migration
As controlled laboratory experiments using full-stage turbines are expanded to replicate more of the complicated flow features associated with real engines, it is important to understand the influence of the vane inlet temperature profile on the high-pressure vane and blade heat transfer as well as its interaction with film cooling. The temperature distribution of the incoming fluid governs not only the input conditions to the boundary layer but also the overall fluid migration. Both of these mechanisms have a strong influence on surface heat flux and therefore component life predictions. To better understand the role of the inlet temperature profile, an electrically heated combustor emulator capable of generating uniform, radial, or hot streak temperature profiles at the high-pressure turbine vane inlet has been designed, constructed, and operated over a wide range of conditions. The device is shown to introduce a negligible pressure distortion while generating the inlet temperature conditions for a stage-and-a-half turbine operating at design-corrected conditions. For the measurements described here, the vane is fully cooled and the rotor purge flow is active, but the blades are uncooled. Detailed temperature measurements are obtained at rake locations upstream and downstream of the turbine stage as well as at the leading edge and platform of the blade in order to characterize the inlet temperature profile and its migration. The use of miniature butt-welded thermocouples at the leading edge and on the platform (protruding into the flow) on a rotating blade is a novel method of mapping a temperature profile. These measurements show that the reduction in fluid temperature due to cooling is similar in magnitude for both uniform and radial vane inlet temperature profiles.
- 1 January 2006
- Published by ASME International
- Vol. 2006, 721-737
Heat Transfer Measurements and Predictions for a Modern, High-Pressure, Transonic Turbine, Including Endwalls
This paper presents both measurements and predictions of the hot-gas-side heat transfer to a modern, one and 1/2 stage high-pressure, transonic turbine. Comparisons of the predicted and measured heat transfer are presented for each airfoil at three locations, as well as on the various endwalls and rotor tip. The measurements were performed using the Ohio State University Gas Turbine Laboratory Test Facility (TTF). The research program utilized an uncooled turbine stage at a range of operating conditions representative of the engine: in terms of corrected speed, flow function, stage pressure ratio, and gas-to-metal temperature ratio. All three airfoils were heavily instrumented for both pressure and heat transfer measurements at multiple locations. A 3-D, compressible, Reynolds-averaged Navier-Stokes CFD solver with k-ω turbulence modeling was used for the CFD predictions. The entire, 1-1/2 stage turbine was solved using a single computation, at two different Reynolds numbers. The CFD solutions were steady, with tangentially mass-averaged inlet/exit boundary condition profiles exchanged between adjacent airfoil-rows. Overall, the CFD heat transfer predictions compared very favorably with both the global operation of the turbine and with the local measurements of heat transfer. A discussion of the features of the turbine heat transfer distributions, and their association with the corresponding flow-physics, has been included.
- 1 January 2006
- Published by ASME International
- Vol. 2006, 721-737
Heat Transfer Measurements and Predictions for a Modern, High-Pressure, Transonic Turbine, Including Endwalls
This paper presents both measurements and predictions of the hot-gas-side heat transfer to a modern, one and 1/2 stage high-pressure, transonic turbine. Comparisons of the predicted and measured heat transfer are presented for each airfoil at three locations, as well as on the various endwalls and rotor tip. The measurements were performed using the Ohio State University Gas Turbine Laboratory Test Facility (TTF). The research program utilized an uncooled turbine stage at a range of operating conditions representative of the engine: in terms of corrected speed, flow function, stage pressure ratio, and gas-to-metal temperature ratio. All three airfoils were heavily instrumented for both pressure and heat transfer measurements at multiple locations. A 3-D, compressible, Reynolds-averaged Navier-Stokes CFD solver with k-ω turbulence modeling was used for the CFD predictions. The entire, 1-1/2 stage turbine was solved using a single computation, at two different Reynolds numbers. The CFD solutions were steady, with tangentially mass-averaged inlet/exit boundary condition profiles exchanged between adjacent airfoil-rows. Overall, the CFD heat transfer predictions compared very favorably with both the global operation of the turbine and with the local measurements of heat transfer. A discussion of the features of the turbine heat transfer distributions, and their association with the corresponding flow-physics, has been included.
- 1 January 2004
- Published by ASME International
- p. 1175-1187
Experimental Investigation of Vane Clocking in a One and 1/2 Stage High Pressure Turbine
Aerodynamic measurements were acquired on a modern single-stage, transonic, high-pressure turbine with the adjacent low-pressure turbine vane row (a typical civilian one and one-half stage turbine rig) to observe the effects of low-pressure turbine vane clocking on overall turbine performance. The turbine rig (loosely referred to in this paper as the stage) was operated at design corrected conditions using the Ohio State University Gas Turbine Laboratory Turbine Test Facility (TTF). The research program utilized uncooled hardware in which all three airfoils were heavily instrumented at multiple spans to develop a full clocking dataset. The low-pressure turbine vane row (LPTV) was clocked relative to the high-pressure turbine vane row (HPTV). Various methods were used to evaluate the influence of clocking on the aeroperformance (efficiency) and the aerodynamics (pressure loading) of the LPTV, including time-resolved and time-averaged measurements. A change in overall efficiency of approximately 2–3% due to clocking effects is demonstrated and could be observed using a variety of independent methods. Maximum efficiency is obtained when the time-average surface pressures are highest on the LPTV and the time-resolved surface pressure (both in the time domain and frequency domain) show the least amount of variation. The overall effect is obtained by integrating over the entire airfoil, as the three-dimensional effects on the LPTV surface are significant. This experimental data set validates several computational research efforts that suggested wake migration is the primary reason for the perceived effectiveness of vane clocking. The suggestion that wake migration is the dominate mechanism in generating the clocking effect is also consistent with anecdotal evidence that fully cooled engine rigs do not see a great deal of clocking effect. This is consistent since the additional disturbances induced by the cooling flows and/or the combustor make it extremely difficult to find an alignment for the LPTV given the strong 3D nature of modern high-pressure turbine flows.
- 1 January 2004
- Published by ASME International
- p. 1175-1187
Experimental Investigation of Vane Clocking in a One and 1/2 Stage High Pressure Turbine
Aerodynamic measurements were acquired on a modern single-stage, transonic, high-pressure turbine with the adjacent low-pressure turbine vane row (a typical civilian one and one-half stage turbine rig) to observe the effects of low-pressure turbine vane clocking on overall turbine performance. The turbine rig (loosely referred to in this paper as the stage) was operated at design corrected conditions using the Ohio State University Gas Turbine Laboratory Turbine Test Facility (TTF). The research program utilized uncooled hardware in which all three airfoils were heavily instrumented at multiple spans to develop a full clocking dataset. The low-pressure turbine vane row (LPTV) was clocked relative to the high-pressure turbine vane row (HPTV). Various methods were used to evaluate the influence of clocking on the aeroperformance (efficiency) and the aerodynamics (pressure loading) of the LPTV, including time-resolved and time-averaged measurements. A change in overall efficiency of approximately 2–3% due to clocking effects is demonstrated and could be observed using a variety of independent methods. Maximum efficiency is obtained when the time-average surface pressures are highest on the LPTV and the time-resolved surface pressure (both in the time domain and frequency domain) show the least amount of variation. The overall effect is obtained by integrating over the entire airfoil, as the three-dimensional effects on the LPTV surface are significant. This experimental data set validates several computational research efforts that suggested wake migration is the primary reason for the perceived effectiveness of vane clocking. The suggestion that wake migration is the dominate mechanism in generating the clocking effect is also consistent with anecdotal evidence that fully cooled engine rigs do not see a great deal of clocking effect. This is consistent since the additional disturbances induced by the cooling flows and/or the combustor make it extremely difficult to find an alignment for the LPTV given the strong 3D nature of modern high-pressure turbine flows.