Orgun Güralp
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Orgun Güralp has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Madhusudan Raghavan
General Motors
1 shared publication - Norman K. Bucknor
Propulsion Systems Research Laboratory, General Motors R&D Center, Warren, MI 48091
1 shared publication - Paul M. Najt
General Motors Research & Development, Warren, MI 40890
1 shared publication - Zoran Filipi
Clemson University, Greenville, SC, USA
1 shared publication
Latest Publications
- Open Access
Development of a Megawatt Charging Capable Test Platform
Vehicle recharge time is a key barrier to widespread adoption of battery electric trucks, where megawatt class charging could be used to achieve refueling times comparable to internal combustion vehicles. This work presents the design and validation of a megawatt-capable rechargeable energy storage system (144 kWh, 40P384S) together with a physics-based modeling framework for safe 1 MW operation. The pack architecture is reconfigurable, enabling nominal 750 V (80P192S) propulsion mode as well as 1125 V and 1500 V charging modes compatible with the Megawatt Charging System (MCS). An equivalent circuit model is developed to relate cell-level parameters to pack-level power, heat generation, and temperature rise, providing guidance on feasible charge profiles and thermal limits. A Simulink-based digital twin of the reconfigurable pack is then used to analyze sensitivity to current sensor mismatch and to verify protection logic for multiple bus voltage configurations. Finally, pack tests up to 1 MW confirm the model-predicted operating envelope and illustrate practical constraints imposed by charger voltage and pack resistance. The combined hardware and modeling approach provides a reusable platform for studying extreme fast charging of medium- and heavy-duty BEV packs-class charging -capable rechargeable energy storage system (144 kWh, 40P384S) together with a physics-based modeling framework for safe 1 MW operation. The pack architecture is reconfigurable, enabling nominal 750 V (80P192S) propulsion mode as well as 1125 V and 1500 V charging modes compatible with the Megawatt Charging System (MCS). An equivalent-circuit model is developed to relate cell-level parameters to pack-level power, heat generation, and temperature rise, providing guidance on feasible charge profiles and thermal limits. A Simulink-based digital twin of the reconfigurable pack is then used to analyze sensitivity to current–sensor mismatch and to verify protection logic for multiple bus-voltage configurations. Finally, pack tests up to 1 MW confirm the model-predicted operating envelope and illustrate practical constraints imposed by charger voltage and pack resistance. The combined hardware and modeling approach provides a reusable platform for studying extreme fast charging of medium- and heavy-duty BEV packs.
Open AccessDevelopment of a Megawatt Charging Capable Test Platform
Vehicle recharge time is a key barrier to widespread adoption of battery electric trucks, where megawatt class charging could be used to achieve refueling times comparable to internal combustion vehicles. This work presents the design and validation of a megawatt-capable rechargeable energy storage system (144 kWh, 40P384S) together with a physics-based modeling framework for safe 1 MW operation. The pack architecture is reconfigurable, enabling nominal 750 V (80P192S) propulsion mode as well as 1125 V and 1500 V charging modes compatible with the Megawatt Charging System (MCS). An equivalent circuit model is developed to relate cell-level parameters to pack-level power, heat generation, and temperature rise, providing guidance on feasible charge profiles and thermal limits. A Simulink-based digital twin of the reconfigurable pack is then used to analyze sensitivity to current sensor mismatch and to verify protection logic for multiple bus voltage configurations. Finally, pack tests up to 1 MW confirm the model-predicted operating envelope and illustrate practical constraints imposed by charger voltage and pack resistance. The combined hardware and modeling approach provides a reusable platform for studying extreme fast charging of medium- and heavy-duty BEV packs-class charging -capable rechargeable energy storage system (144 kWh, 40P384S) together with a physics-based modeling framework for safe 1 MW operation. The pack architecture is reconfigurable, enabling nominal 750 V (80P192S) propulsion mode as well as 1125 V and 1500 V charging modes compatible with the Megawatt Charging System (MCS). An equivalent-circuit model is developed to relate cell-level parameters to pack-level power, heat generation, and temperature rise, providing guidance on feasible charge profiles and thermal limits. A Simulink-based digital twin of the reconfigurable pack is then used to analyze sensitivity to current–sensor mismatch and to verify protection logic for multiple bus-voltage configurations. Finally, pack tests up to 1 MW confirm the model-predicted operating envelope and illustrate practical constraints imposed by charger voltage and pack resistance. The combined hardware and modeling approach provides a reusable platform for studying extreme fast charging of medium- and heavy-duty BEV packs.
- 24 June 2013
- Published by Wiley in Journal of Engineering for Gas Turbines and Power
- Vol. 135 (8) , 081501
Method for Determining Instantaneous Temperature at the Surface of Combustion Chamber Deposits in an HCCI Engine
Homogeneous charge compression ignition (HCCI) combustion is widely regarded as an attractive option for future high efficiency gasoline engines. HCCI combustion permits operation with a highly dilute, well mixed charge, resulting in high thermal efficiency and extremely low NOx and soot emissions, two qualities essential for future propulsion system solutions. Because HCCI is a thermokinetically dominated process, full understanding of how combustion chamber boundary thermal conditions affect the combustion process are crucial. This includes the dynamics of the effective chamber wall surface temperature, as dictated by the formation of combustion chamber deposits (CCD). It has been demonstrated that, due to the combination of CCD thermal properties and the sensitivity of HCCI to wall temperature, the phasing of autoignition can vary significantly as CCD coverage in the chamber increases. In order to better characterize and quantify the influence of CCDs, a numerical methodology has been developed which permits calculation of the crank-angle resolved local temperature profile at the surface of a layer of combustion chamber deposits. This unique predictor-corrector methodology relies on experimental measurement of instantaneous temperature underneath the layer, i.e., at the metal-CCD interface, and known deposit layer thickness. A numerical method for validation of these calculations has also been devised. The resultant crank-angle resolved CCD surface temperature and heat flux profiles both on top and under the CCD layer provide valuable insight into the near wall phenomena, and shed light on the interplay between the dynamics of the heat transfer process and HCCI burn rates.
- 24 June 2013
- Published by Wiley in Journal of Engineering for Gas Turbines and Power
- Vol. 135 (8) , 081501
Method for Determining Instantaneous Temperature at the Surface of Combustion Chamber Deposits in an HCCI Engine
Homogeneous charge compression ignition (HCCI) combustion is widely regarded as an attractive option for future high efficiency gasoline engines. HCCI combustion permits operation with a highly dilute, well mixed charge, resulting in high thermal efficiency and extremely low NOx and soot emissions, two qualities essential for future propulsion system solutions. Because HCCI is a thermokinetically dominated process, full understanding of how combustion chamber boundary thermal conditions affect the combustion process are crucial. This includes the dynamics of the effective chamber wall surface temperature, as dictated by the formation of combustion chamber deposits (CCD). It has been demonstrated that, due to the combination of CCD thermal properties and the sensitivity of HCCI to wall temperature, the phasing of autoignition can vary significantly as CCD coverage in the chamber increases. In order to better characterize and quantify the influence of CCDs, a numerical methodology has been developed which permits calculation of the crank-angle resolved local temperature profile at the surface of a layer of combustion chamber deposits. This unique predictor-corrector methodology relies on experimental measurement of instantaneous temperature underneath the layer, i.e., at the metal-CCD interface, and known deposit layer thickness. A numerical method for validation of these calculations has also been devised. The resultant crank-angle resolved CCD surface temperature and heat flux profiles both on top and under the CCD layer provide valuable insight into the near wall phenomena, and shed light on the interplay between the dynamics of the heat transfer process and HCCI burn rates.