Klaus Wendl
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Klaus Wendl has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Jochen Franke
BG Trauma Center at Ruprecht-Karls-Universität Heidelberg, Ludwigshafen, Germany
3 shared publications - Arnold J. Suda
BG Trauma Center Ludwigshafen at Heidelberg University Hospital, Ludwig-Guttmann-Strasse 13, D-67071 Ludwigshafen, Germany. address for A.J. Suda:. address for P.A. Grützner:
2 shared publications - Jan von Recum
BG Klinik Ludwigshafen
2 shared publications - Paul Alfred Grützner
BG-Unfallklinik Ludwigshafen
2 shared publications Paul Alfred Grützner
1 shared publication- Thomas Giese
Sportopädie Zentrum für Orthopädie Heidelberg, Max-Reger-Strasse 5-7, D-69121 Heidelberg, Germany. address:
1 shared publication
Latest Publications
- 7 May 2014
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 96 (9) , e72
Intraoperative Three-Dimensional Imaging in the Treatment of Calcaneal Fractures
Background: Displaced intra-articular calcaneal fractures are frequently treated by open reduction and internal fixation. The usual intraoperative monitoring by means of fluoroscopy does not always provide complete intraoperative information for the surgeon. The aims of this study were to analyze the percentage of patients for whom intraoperative three-dimensional imaging leads to intraoperative revision and whether the avoidance of an intra-articular step or gap influences the clinical outcome. Methods: From August 2001 to June 2009, 377 consecutive, operatively treated calcaneal fractures were identified in a retrospective chart review. The results of the intraoperative three-dimensional scans were analyzed for the rate of and the reason for intraoperative revision. For the clinical evaluation, all patients with Sanders type-II and III fractures who were seen from October 2002 to January 2006 were included. When the outer shape of the calcaneus was successfully restored, the fractures were divided into two groups according to the reduction outcome for all joint surfaces (a step-off or gap of <2 mm or ≥2 mm). Results: The intraoperative revision rate was 40.3%. An additional fracture reduction was performed in 19.6% of the patients. Seventy-seven fractures were followed clinically. The American Orthopaedic Foot & Ankle Society (AOFAS) score indicated that postoperative joint surface congruence had a significant influence on clinical outcome, in both the bivariate and the multivariate analysis. The same relationship was shown between the joint surface congruence and the degree of osteoarthritis. Conclusions: In many cases, intraoperative three-dimensional imaging identifies intra-articular incongruence and implants that are not detected by fluoroscopy. Due to the resulting options for better joint surface reconstruction, clinical outcomes may be improved, at times requiring repeat reduction, and posttraumatic osteoarthritis may be reduced. Level of Evidence: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
- 7 May 2014
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 96 (9) , e72
Intraoperative Three-Dimensional Imaging in the Treatment of Calcaneal Fractures
Background: Displaced intra-articular calcaneal fractures are frequently treated by open reduction and internal fixation. The usual intraoperative monitoring by means of fluoroscopy does not always provide complete intraoperative information for the surgeon. The aims of this study were to analyze the percentage of patients for whom intraoperative three-dimensional imaging leads to intraoperative revision and whether the avoidance of an intra-articular step or gap influences the clinical outcome. Methods: From August 2001 to June 2009, 377 consecutive, operatively treated calcaneal fractures were identified in a retrospective chart review. The results of the intraoperative three-dimensional scans were analyzed for the rate of and the reason for intraoperative revision. For the clinical evaluation, all patients with Sanders type-II and III fractures who were seen from October 2002 to January 2006 were included. When the outer shape of the calcaneus was successfully restored, the fractures were divided into two groups according to the reduction outcome for all joint surfaces (a step-off or gap of <2 mm or ≥2 mm). Results: The intraoperative revision rate was 40.3%. An additional fracture reduction was performed in 19.6% of the patients. Seventy-seven fractures were followed clinically. The American Orthopaedic Foot & Ankle Society (AOFAS) score indicated that postoperative joint surface congruence had a significant influence on clinical outcome, in both the bivariate and the multivariate analysis. The same relationship was shown between the joint surface congruence and the degree of osteoarthritis. Conclusions: In many cases, intraoperative three-dimensional imaging identifies intra-articular incongruence and implants that are not detected by fluoroscopy. Due to the resulting options for better joint surface reconstruction, clinical outcomes may be improved, at times requiring repeat reduction, and posttraumatic osteoarthritis may be reduced. Level of Evidence: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
- 1 August 2012
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 94 (15) , 1386-1390
Intraoperative Three-Dimensional Imaging in the Treatment of Acute Unstable Syndesmotic Injuries
Ve three-dimensional imaging can demonstrate a large proportion of malreductions. The aim of this study was to determine whether intraoperative three-dimensional imaging improves the detection of inadequate positioning of the distal aspect of the fibula in the tibiofibular incisura after syndesmotic screw insertion compared with the findings on standard intraoperative fluoroscopy. Methods: Of 2286 ankle fractures treated operatively from August 2001 to February 2011, 251 consecutive cases (11%) were identified in a retrospective chart review. All had an unstable syndesmosis and underwent syndesmosis stabilization on the basis of an intraoperative hook test. After fluoroscopy, an intraoperative three-dimensional scan was performed. The result of this scan was documented by the surgeon and analyzed retrospectively with regard to the incidence and nature of the need for intraoperative revisions. Results: The intraoperative three-dimensional scan altered the surgical outcome in eighty-two ankles (32.7%). In most ankles (seventy-seven; 30.7%), the reduction was improved, with the most common improvement being the alignment of the fibula in the tibiofibular incisura in sixty-four patients (25.5%) followed by correction of the fracture reduction in thirteen patients (5.2%). The other five alterations involved implant corrections. The most common malpositions requiring correction after insertion of a positioning screw, with or without additional fixation, were anterior displacement and internal rotation of the distal aspect of the fibula. Conclusions: Following open reduction and internal fixation of an ankle fracture, the correct position of the syndesmosis cannot be evaluated reliably with use of conventional radiographs or intraoperative fluoroscopy. In view of the high proportion of positive findings in this study, we believe that any treatment of a syndesmotic injury should include intraoperative three-dimensional imaging or at least a postoperative computed tomography scan. Level of Evidence: Diagnostic Level III. See Instructions for Authors for a complete description of levels of evidence....
- 1 August 2012
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 94 (15) , 1386-1390
Intraoperative Three-Dimensional Imaging in the Treatment of Acute Unstable Syndesmotic Injuries
Ve three-dimensional imaging can demonstrate a large proportion of malreductions. The aim of this study was to determine whether intraoperative three-dimensional imaging improves the detection of inadequate positioning of the distal aspect of the fibula in the tibiofibular incisura after syndesmotic screw insertion compared with the findings on standard intraoperative fluoroscopy. Methods: Of 2286 ankle fractures treated operatively from August 2001 to February 2011, 251 consecutive cases (11%) were identified in a retrospective chart review. All had an unstable syndesmosis and underwent syndesmosis stabilization on the basis of an intraoperative hook test. After fluoroscopy, an intraoperative three-dimensional scan was performed. The result of this scan was documented by the surgeon and analyzed retrospectively with regard to the incidence and nature of the need for intraoperative revisions. Results: The intraoperative three-dimensional scan altered the surgical outcome in eighty-two ankles (32.7%). In most ankles (seventy-seven; 30.7%), the reduction was improved, with the most common improvement being the alignment of the fibula in the tibiofibular incisura in sixty-four patients (25.5%) followed by correction of the fracture reduction in thirteen patients (5.2%). The other five alterations involved implant corrections. The most common malpositions requiring correction after insertion of a positioning screw, with or without additional fixation, were anterior displacement and internal rotation of the distal aspect of the fibula. Conclusions: Following open reduction and internal fixation of an ankle fracture, the correct position of the syndesmosis cannot be evaluated reliably with use of conventional radiographs or intraoperative fluoroscopy. In view of the high proportion of positive findings in this study, we believe that any treatment of a syndesmotic injury should include intraoperative three-dimensional imaging or at least a postoperative computed tomography scan. Level of Evidence: Diagnostic Level III. See Instructions for Authors for a complete description of levels of evidence....
- 1 October 2011
- Published by Georg Thieme Verlag KG in OP-Journal
- Vol. 27 (02) , 138-142
Navigiertes Operieren an der Wirbelsäule
Navigiertes Operieren an der Wirbelsäule ist seit 15 Jahren klinische Realität. Neben der CT-gestützten Navigation, die den Vorteil der besten Bildqualität bietet, kommen auch C-Arm-gestützte Verfahren zur intraoperativen 2- oder 3-dimensionalen Bildakquise zur Anwendung. Insbesondere 3-D-Bildwandler weisen bei guter Bildqualität und hoher Registrierungsgenauigkeit die Option auf, Veränderungen der Anatomie beim frakturierten Wirbel zu adressieren und minimalinvasiv zu instrumentieren. Das bei Weitem häufigste Einsatzgebiet ist die dorsale Stabilisierung mit Pedikelschrauben an der thorakalen und lumbalen Wirbelsäule. Andere Anwendungen wie die Instrumentierung von Halswirbeln, C1-/C2-Fusionen oder ventrale Stabilisierungen sind zahlenmäßig selten. Die klinischen Erfahrungen zeigen einen Trend zur genaueren Platzierung von Pedikelschrauben durch die Anwendung der Navigation, v. a. an HWS und LWS, die Strahlenbelastung für Patient und OP-Personal sinkt. Dafür steigen OP-Zeiten und die Kosten für die technische Ausstattung. Trotz theoretischer und teilweise belegter praktischer Vorteile der Computernavigation an der Wirbelsäule steht die flächendeckende Anwendung noch aus. Image-guided spine surgery was introduced to trauma surgery about 15 years ago. Image acquisition can be based on computer tomography, two- or three-dimensional C-arm pictures, whereby CT offers the best image quality. Three-dimensional image intensifiers show acceptable image quality, have the advantage of an automatic registration process and can consider variations of patient anatomy, e.g., following intraoperative reduction of fractured vertebrae. They also allow minimally invasive operation procedures. Pedicle screw placement in the thoracic and lumbar spines is by far the most common spine surgery in traumatology. Other navigated applications like pedicle screw placement in the cervical spine, C1/C2 fusions etc. are relatively rare in everyday clinical routine. Clinical studies show a trend towards more precise pedicle screw placement, especially in the lumbar and cervical spines using image-guided spine surgery. The overall radiation exposure can be reduced by means of intraoperative navigation procedures. On the other hand, there is an increase in costs and overall time for surgery. Although image-guided spine surgery has different advantages, both theoretically and clinically proven, it is still no standard method for use in everyday surgery.
- 1 October 2011
- Published by Georg Thieme Verlag KG in OP-Journal
- Vol. 27 (02) , 138-142
Navigiertes Operieren an der Wirbelsäule
Navigiertes Operieren an der Wirbelsäule ist seit 15 Jahren klinische Realität. Neben der CT-gestützten Navigation, die den Vorteil der besten Bildqualität bietet, kommen auch C-Arm-gestützte Verfahren zur intraoperativen 2- oder 3-dimensionalen Bildakquise zur Anwendung. Insbesondere 3-D-Bildwandler weisen bei guter Bildqualität und hoher Registrierungsgenauigkeit die Option auf, Veränderungen der Anatomie beim frakturierten Wirbel zu adressieren und minimalinvasiv zu instrumentieren. Das bei Weitem häufigste Einsatzgebiet ist die dorsale Stabilisierung mit Pedikelschrauben an der thorakalen und lumbalen Wirbelsäule. Andere Anwendungen wie die Instrumentierung von Halswirbeln, C1-/C2-Fusionen oder ventrale Stabilisierungen sind zahlenmäßig selten. Die klinischen Erfahrungen zeigen einen Trend zur genaueren Platzierung von Pedikelschrauben durch die Anwendung der Navigation, v. a. an HWS und LWS, die Strahlenbelastung für Patient und OP-Personal sinkt. Dafür steigen OP-Zeiten und die Kosten für die technische Ausstattung. Trotz theoretischer und teilweise belegter praktischer Vorteile der Computernavigation an der Wirbelsäule steht die flächendeckende Anwendung noch aus. Image-guided spine surgery was introduced to trauma surgery about 15 years ago. Image acquisition can be based on computer tomography, two- or three-dimensional C-arm pictures, whereby CT offers the best image quality. Three-dimensional image intensifiers show acceptable image quality, have the advantage of an automatic registration process and can consider variations of patient anatomy, e.g., following intraoperative reduction of fractured vertebrae. They also allow minimally invasive operation procedures. Pedicle screw placement in the thoracic and lumbar spines is by far the most common spine surgery in traumatology. Other navigated applications like pedicle screw placement in the cervical spine, C1/C2 fusions etc. are relatively rare in everyday clinical routine. Clinical studies show a trend towards more precise pedicle screw placement, especially in the lumbar and cervical spines using image-guided spine surgery. The overall radiation exposure can be reduced by means of intraoperative navigation procedures. On the other hand, there is an increase in costs and overall time for surgery. Although image-guided spine surgery has different advantages, both theoretically and clinically proven, it is still no standard method for use in everyday surgery.