Ulf Maeder
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ulf Maeder has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Marcel Reginatto
Physikalisch - Technische Bundesanstalt, Bundesallee 100, Braunschweig, 38116, GERMANY
3 shared publications Martin Fiebich
Institute of Medical Physics and Radiation Protection, Technische Hochschule Mittelhessen - University of Applied Sciences, 35390 Giessen, Germany
3 shared publications- Mathias Anton
Ionizing Radiation, Physikalisch - Technische Bundesanstalt, Bundesallee 100, D-38116 Braunschweig, Braunschweig, 38116, GERMANY
3 shared publications S Schopphoven
Reference Ctr Mammog Screening Southwest Germany, Giessen, Germany
3 shared publicationsThomas Schmidts
Institute of Bioprocess Engineering and Pharmaceutical Technology, Technische Hochschule Mittelhessen - University of Applied Sciences, 35390 Giessen, Germany
3 shared publicationsFrank Runkel
Institute of Bioprocess Engineering and Pharmaceutical Technology, Technische Hochschule Mittelhessen - University of Applied Sciences, 35390 Giessen, Germany
2 shared publications
Latest Publications
- Open Access
- 19 July 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (15) , 155013
A nonparametric measure of contrast in x-ray images
Objective. We propose a nonparametric figure of merit, the contrast equivalent distance CED, to measure contrast directly from clinical images. Approach. A relative brightness distance δ is calculated by making use of the order statistic of the pixel values. By multiplying δ with the grey value range R, the mean brightness distance MBD is obtained. From the MBD, the CED and the distance-to-noise ratio DNR can be derived. The latter is the ratio of the MBD and a previously suggested nonparametric measure τ for the noise. Since the order statistic is independent of the spatial arrangement of the pixel values, the measures can be obtained directly from clinical images. We apply the new measures to mammography images of an anthropomorphic phantom and of a phantom with a step wedge as well as to CT images of a head phantom. Main results. For low-noise images of a step wedge, the MBD is equivalent to the conventional grey value distance. While this measure permits the evaluation of clinical images, it is sensitive to noise. Therefore, noise has to be quantified at the same time. When the ratio σ / τ of the noise standard deviation σ to τ is available, validity limits for the CED as a measure of contrast can be established. The new figures of merit can be calculated for entire images as well as on regions of interest (ROI) with an edge length not smaller than 32 px. Significance. The new figures of merit are suited to quantify the quality of clinical images without relying on the assumption of a linear, shift-invariant system. They can be used for any kind of greyscale image, provided the ratio σ / τ can be estimated. This will hopefully help to achieve the optimisation of image quality vs dose required by radioprotection laws.
- 19 July 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (15) , 155013
Open AccessA nonparametric measure of contrast in x-ray images
Objective. We propose a nonparametric figure of merit, the contrast equivalent distance CED, to measure contrast directly from clinical images. Approach. A relative brightness distance δ is calculated by making use of the order statistic of the pixel values. By multiplying δ with the grey value range R, the mean brightness distance MBD is obtained. From the MBD, the CED and the distance-to-noise ratio DNR can be derived. The latter is the ratio of the MBD and a previously suggested nonparametric measure τ for the noise. Since the order statistic is independent of the spatial arrangement of the pixel values, the measures can be obtained directly from clinical images. We apply the new measures to mammography images of an anthropomorphic phantom and of a phantom with a step wedge as well as to CT images of a head phantom. Main results. For low-noise images of a step wedge, the MBD is equivalent to the conventional grey value distance. While this measure permits the evaluation of clinical images, it is sensitive to noise. Therefore, noise has to be quantified at the same time. When the ratio σ / τ of the noise standard deviation σ to τ is available, validity limits for the CED as a measure of contrast can be established. The new figures of merit can be calculated for entire images as well as on regions of interest (ROI) with an edge length not smaller than 32 px. Significance. The new figures of merit are suited to quantify the quality of clinical images without relying on the assumption of a linear, shift-invariant system. They can be used for any kind of greyscale image, provided the ratio σ / τ can be estimated. This will hopefully help to achieve the optimisation of image quality vs dose required by radioprotection laws.
- Open Access
- 6 February 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (4) , 045003
A nonparametric measure of noise in x-ray diagnostic images—mammography
Objective. In x-ray diagnostics, modern image reconstruction or image processing methods may render established methods of image quality assessment inadequate. Task specific quality assessment by using model observers has the disadvantage of being very labour-intensive. Therefore, it appears highly desirable to develop novel image quality parameters that neither rely on the linearity and the shift-invariace of the imaging system nor require the acquisition of hundreds of images as is necessary for the application of model observers, and which can be derived directly from diagnostic images. Approach. A new measure for the noise based on non-maximum-suppression images is defined and its properties are explored using simulated images before it is applied to an exposure series of mammograms of a homogeneous phantom and a 3D-printed breast phantom to demonstrate its usefulness under realistic conditions. Main results. The new noise parameter cannot only be derived from images with a homogeneous background but it can be extracted directly from images containing anatomic structures and is proportional to the standard deviation of the noise. At present, the applicability is restricted to mammography, which satisfies the assumption of short covariance length of the noise. Significance. The new measure of the noise is but a first step of the development of a set of parameters that are required to quantify image quality directly from diagnostic images without relying on the assumption of a linear, shift-invariant system, e.g. by providing measures of sharpness, contrast and structural complexity, in addition to the noise measure. For mammography, a convenient method is now available to quantify noise in processed diagnostic images.
- 6 February 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (4) , 045003
Open AccessA nonparametric measure of noise in x-ray diagnostic images—mammography
Objective. In x-ray diagnostics, modern image reconstruction or image processing methods may render established methods of image quality assessment inadequate. Task specific quality assessment by using model observers has the disadvantage of being very labour-intensive. Therefore, it appears highly desirable to develop novel image quality parameters that neither rely on the linearity and the shift-invariace of the imaging system nor require the acquisition of hundreds of images as is necessary for the application of model observers, and which can be derived directly from diagnostic images. Approach. A new measure for the noise based on non-maximum-suppression images is defined and its properties are explored using simulated images before it is applied to an exposure series of mammograms of a homogeneous phantom and a 3D-printed breast phantom to demonstrate its usefulness under realistic conditions. Main results. The new noise parameter cannot only be derived from images with a homogeneous background but it can be extracted directly from images containing anatomic structures and is proportional to the standard deviation of the noise. At present, the applicability is restricted to mammography, which satisfies the assumption of short covariance length of the noise. Significance. The new measure of the noise is but a first step of the development of a set of parameters that are required to quantify image quality directly from diagnostic images without relying on the assumption of a linear, shift-invariant system, e.g. by providing measures of sharpness, contrast and structural complexity, in addition to the noise measure. For mammography, a convenient method is now available to quantify noise in processed diagnostic images.
- Open Access
- 18 November 2021
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 66 (22) , 225015
The regression detectability index RDI for mammography images of breast phantoms with calcification-like objects and anatomical background
Currently, quality assurance measurements in mammography are performed on unprocessed images. For diagnosis, however, radiologists are provided with processed images. This image processing is optimised for images of human anatomy and therefore does not always perform satisfactorily with technical phantoms. To overcome this problem, it may be possible to use anthropomorphic phantoms reflecting the anatomic structure of the human breast in place of technical phantoms when carrying out task-specific quality assessment using model observers. However, the use of model observers is hampered by the fact that a large number of images needs to be acquired. A recently published novel observer called the regression detectability index (RDI) needs significantly fewer images, but requires the background of the images to be flat. Therefore, to be able to apply the RDI to images of anthropomorphic phantoms, the anatomic background needs to be removed. For this, a procedure in which the anatomical structures are fitted by thin plate spline (TPS) interpolation has been developed. When the object to be detected is small, such as a calcification-like lesion, it is shown that the anatomic background can be removed successfully by subtracting the TPS interpolation, which makes the background-free image accessible to the RDI. We have compared the detectability obtained by the RDI with TPS background subtraction to results of the channelized Hotelling observer (CHO) and human observers. With the RDI, results for the detectability d ′ can be obtained using 75% fewer images compared to the CHO, while the same uncertainty of d ′ is achieved. Furthermore, the correlation of d ′ (RDI) with the results of human observers is at least as good as that of d ′ (CHO) with human observers.
- 18 November 2021
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 66 (22) , 225015
Open AccessThe regression detectability index RDI for mammography images of breast phantoms with calcification-like objects and anatomical background
Currently, quality assurance measurements in mammography are performed on unprocessed images. For diagnosis, however, radiologists are provided with processed images. This image processing is optimised for images of human anatomy and therefore does not always perform satisfactorily with technical phantoms. To overcome this problem, it may be possible to use anthropomorphic phantoms reflecting the anatomic structure of the human breast in place of technical phantoms when carrying out task-specific quality assessment using model observers. However, the use of model observers is hampered by the fact that a large number of images needs to be acquired. A recently published novel observer called the regression detectability index (RDI) needs significantly fewer images, but requires the background of the images to be flat. Therefore, to be able to apply the RDI to images of anthropomorphic phantoms, the anatomic background needs to be removed. For this, a procedure in which the anatomical structures are fitted by thin plate spline (TPS) interpolation has been developed. When the object to be detected is small, such as a calcification-like lesion, it is shown that the anatomic background can be removed successfully by subtracting the TPS interpolation, which makes the background-free image accessible to the RDI. We have compared the detectability obtained by the RDI with TPS background subtraction to results of the channelized Hotelling observer (CHO) and human observers. With the RDI, results for the detectability d ′ can be obtained using 75% fewer images compared to the CHO, while the same uncertainty of d ′ is achieved. Furthermore, the correlation of d ′ (RDI) with the results of human observers is at least as good as that of d ′ (CHO) with human observers.
- Open Access
- 16 November 2015
- Published by Wiley in Computational and Mathematical Methods in Medicine
- Vol. 2015, 1-9
Image-Processing Scheme to Detect Superficial Fungal Infections of the Skin
The incidence of superficial fungal infections is assumed to be 20 to 25% of the global human population. Fluorescence microscopy of extracted skin samples is frequently used for a swift assessment of infections. To support the dermatologist, an image-analysis scheme has been developed that evaluates digital microscopic images to detect fungal hyphae. The aim of the study was to increase diagnostic quality and to shorten the time-to-diagnosis. The analysis, consisting of preprocessing, segmentation, parameterization, and classification of identified structures, was performed on digital microscopic images. A test dataset of hyphae and false-positive objects was created to evaluate the algorithm. Additionally, the performance for real clinical images was investigated using 415 images. The results show that the sensitivity for hyphae is 94% and 89% for singular and clustered hyphae, respectively. The mean exclusion rate is 91% for the false-positive objects. The sensitivity for clinical images was 83% and the specificity was 79%. Although the performance is lower for the clinical images than for the test dataset, a reliable and fast diagnosis can be achieved since it is not crucial to detect every hypha to conclude that a sample consisting of several images is infected. The proposed analysis therefore enables a high diagnostic quality and a fast sample assessment to be achieved.
- 16 November 2015
- Published by Wiley in Computational and Mathematical Methods in Medicine
- Vol. 2015, 1-9
Open AccessImage-Processing Scheme to Detect Superficial Fungal Infections of the Skin
The incidence of superficial fungal infections is assumed to be 20 to 25% of the global human population. Fluorescence microscopy of extracted skin samples is frequently used for a swift assessment of infections. To support the dermatologist, an image-analysis scheme has been developed that evaluates digital microscopic images to detect fungal hyphae. The aim of the study was to increase diagnostic quality and to shorten the time-to-diagnosis. The analysis, consisting of preprocessing, segmentation, parameterization, and classification of identified structures, was performed on digital microscopic images. A test dataset of hyphae and false-positive objects was created to evaluate the algorithm. Additionally, the performance for real clinical images was investigated using 415 images. The results show that the sensitivity for hyphae is 94% and 89% for singular and clustered hyphae, respectively. The mean exclusion rate is 91% for the false-positive objects. The sensitivity for clinical images was 83% and the specificity was 79%. Although the performance is lower for the clinical images than for the test dataset, a reliable and fast diagnosis can be achieved since it is not crucial to detect every hypha to conclude that a sample consisting of several images is infected. The proposed analysis therefore enables a high diagnostic quality and a fast sample assessment to be achieved.
- 1 October 2012
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 17 (10) , 1060111-1060118
Evaluation and quantification of spectral information in tissue by confocal microscopy
A confocal imaging and image processing scheme is introduced to visualize and evaluate the spatial distribution of spectral information in tissue. The image data are recorded using a confocal laser-scanning microscope equipped with a detection unit that provides high spectral resolution. The processing scheme is based on spectral data, is less error-prone than intensity-based visualization and evaluation methods, and provides quantitative information on the composition of the sample. The method is tested and validated in the context of the development of dermal drug delivery systems, introducing a quantitative uptake indicator to compare the performances of different delivery systems is introduced. A drug penetration study was performed in vitro. The results show that the method is able to detect, visualize and measure spectral information in tissue. In the penetration study, uptake efficiencies of different experiment setups could be discriminated and quantitatively described. The developed uptake indicator is a step towards a quantitative assessment and, in a more general view apart from pharmaceutical research, provides valuable information on tissue composition. It can potentially be used for clinical in vitro and in vivo applications.
- 1 October 2012
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 17 (10) , 1060111-1060118
Evaluation and quantification of spectral information in tissue by confocal microscopy
A confocal imaging and image processing scheme is introduced to visualize and evaluate the spatial distribution of spectral information in tissue. The image data are recorded using a confocal laser-scanning microscope equipped with a detection unit that provides high spectral resolution. The processing scheme is based on spectral data, is less error-prone than intensity-based visualization and evaluation methods, and provides quantitative information on the composition of the sample. The method is tested and validated in the context of the development of dermal drug delivery systems, introducing a quantitative uptake indicator to compare the performances of different delivery systems is introduced. A drug penetration study was performed in vitro. The results show that the method is able to detect, visualize and measure spectral information in tissue. In the penetration study, uptake efficiencies of different experiment setups could be discriminated and quantitatively described. The developed uptake indicator is a step towards a quantitative assessment and, in a more general view apart from pharmaceutical research, provides valuable information on tissue composition. It can potentially be used for clinical in vitro and in vivo applications.
- 9 February 2012
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8225, 822523
Spectrally resolved visualization of fluorescent dyes permeating into skin
We present a spectrally resolved confocal imaging approach to qualitatively asses the overall uptake and the penetration depth of fluorescent dyes into biological tissue. We use a confocal microscope with a spectral resolution of 5 nm to measure porcine skin tissue after performing a Franz-Diffusion experiment with a submicron emulsion enriched with the fluorescent dye Nile Red. The evaluation uses linear unmixing of the dye and the tissue autofluorescence spectra. The results are combined with a manual segmentation of the skin's epidermis and dermis layers to assess the penetration behavior additionally to the overall uptake. The diffusion experiments, performed for 3h and 24h, show a 3-fold increased dye uptake in the epidermis and dermis for the 24h samples. As the method is based on spectral information it does not face the problem of superimposed dye and tissue spectra and therefore is more precise compared to intensity based evaluation methods.
- 9 February 2012
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8225, 822523
Spectrally resolved visualization of fluorescent dyes permeating into skin
We present a spectrally resolved confocal imaging approach to qualitatively asses the overall uptake and the penetration depth of fluorescent dyes into biological tissue. We use a confocal microscope with a spectral resolution of 5 nm to measure porcine skin tissue after performing a Franz-Diffusion experiment with a submicron emulsion enriched with the fluorescent dye Nile Red. The evaluation uses linear unmixing of the dye and the tissue autofluorescence spectra. The results are combined with a manual segmentation of the skin's epidermis and dermis layers to assess the penetration behavior additionally to the overall uptake. The diffusion experiments, performed for 3h and 24h, show a 3-fold increased dye uptake in the epidermis and dermis for the 24h samples. As the method is based on spectral information it does not face the problem of superimposed dye and tissue spectra and therefore is more precise compared to intensity based evaluation methods.