MCMichael A. Carron

Michael A. Carron

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Michael A. Carron has a total of 17 co-authors. Here are the top co-authors by number of shared publications:

  • Adrianna Thibault

    Division of Facial Plastic and Reconstructive Surgery, Department of Otolaryngology-Head and Neck Surgery, Wayne State University School of Medicine, Detroit, Michigan

    1 shared publication
  • Cynthia Bir

    Department of Biomedical Engineering, Wayne State University

    1 shared publication
  • Giancarlo Zuliani

    Division of Facial Plastic and Reconstructive Surgery, Department of Otolaryngology-Head and Neck Surgery, Wayne State University School of Medicine, Detroit, Michigan

    1 shared publication
  • Hani Rayess

    Division of Facial Plastic Surgery, Department of Otolaryngology, Wayne State University, Detroit, MI, USA

    1 shared publication
  • Houmehr Hojjat

    Division of Facial Plastic Surgery, Department of Otolaryngology, Wayne State University, Detroit, MI, USA

    1 shared publication
  • Jared Johnson

    Division of Facial Plastic Surgery, Department of Otolaryngology, Wayne State University, Detroit, MI, USA

    1 shared publication

Latest Publications

  • Functional Reconstruction of Forehead and Midface Deficits Using the Endoscopic Technique and Bio-Absorbable Implants

    by Jared Johnson, Houmehr Hojjat, Michael T. Chung, Khashayar Arianpour, Hani Rayess, Robert Eckert, Michael Carron

    Objectives: Functional deficits of the forehead and midface can pose significant problems for patients varying from mild asymmetry to various degrees of functional impairment including total paralysis. Our objectives were to analyse the use of bio-absorbable implants to reconstruct forehead and midface deficits, all of which were for functional (noncosmetic) reasons. Methods: This study was a retrospective case series between 2008 and 2018. Institutional review board approval was obtained from the Beaumont Health Human Investigation Committee. Surgeries were performed at a tertiary care centre. We evaluated 50 patients who underwent correction of functional deficits of forehead, eyebrow, and midface using the endoscopic technique and bio-absorbable implants. Patient demographics and indicated etiologies and characterization of minor and major complications and their occurrence rates were characterized. Results: Fifty patients were included in the study from 2008 to 2018, with 68% female and 32% male. Combined blepharoplasty and brow lift was the most commonly performed procedure, followed by midface lift and browplasty. The mean follow-up time was 372 days. No major operative complications including stroke, permanent nerve paralysis, or mortality occurred. There was a 4% rate of temporary nerve paresthesia that resolved, 2% rate of infection, and 6% rate of implant migration requiring revision surgery. Conclusion: The endoscopic approach and use of bio-absorbable implants to reconstruct functional deficits of the forehead and midface are safe and effective. There were zero major complications and most of the minor complications were temporary. There was a significant association between non-age-related functional impairment and risk of complication.


  • Stability of Midface Fracture Repair Using Absorbable Plate and Screw System Pilot Holes Drilled and Pin Placement at Angles Other Than 90°

    by Michael A. Carron, Giancarlo Zuliani, Lucio Pereira, Maher Abuhamdan, Adrianna Thibault, Nathan Dau, Cynthia Bir

    Importance: Conventional plating systems use titanium plates for fixation of fractures, with benefits of strength and biocompatibility. However, titanium plates require that screws be placed at a 90° angle to the pilot holes. In the midface, this becomes extremely difficult. Today, a variety of craniomaxillofacial osteosynthesis systems are available, including resorbable plating systems. Specifically, the KLS Martin Sonic Weld system ultrasonically fuses the plate and the head of the pin when placed and will fill the pilot hole grooves completely even at less than 90° angles, which provides a tremendous advantage in midface fracture repair. Objective: To determine if the KLS Martin Sonic Weld system provides plate-screw construct stability in human heads even when placed at acute angles at the midface buttresses. Design, Setting, and Specimens: Twenty cadaveric head specimens with the mandible removed were prepared by creating osteotomies in the midface buttresses bilaterally. Specimens were defleshed and placed in a 2-part testing rig to hold and position the head for testing in a standard material testing system. Testing was performed at the Wayne State University Bioengineering test laboratories, Detroit, Michigan, using an Instron device and high-speed camera. Specimens were plated on one side of the midface using the KLS Martin Sonic Weld system with pilot holes and pins placed at 90° angles. On the contralateral side, the buttresses were plated with the KLS Martin Sonic Weld system at 60°, 45°, and 30° angles. Data were collected using the TDAS data acquisition system and were compared with matched pairs within each specimen. Main Outcomes and Measures: Ultrasonically vibrated pins placed into absorbable mini-plates at less than 90° angles with the KLS Martin Sonic Weld system were compared with the same amount of stress as the system placed at a 90° angle before demonstrating plate-screw construct failure. Results: Fifty-seven paired tests were collected, with 114 total tests. Twenty failures were due to bone breakage, and 94 fixations failed as a result of the plate-screw construct breaking. Fractures fixated with the ultrasonic absorbable plating system placed with screws at all tested angles failed at similar loads to our control plates with pins placed at 90° angles. These results lend the surgeon to successfully reduce fractures in the midface fragments in difficult-to-reach areas and possibly cut down on operative time while improving the chance of achieving a long-lasting adequate reduction. Conclusions and Relevance: Although there is a measured difference in the laboratory, no clinical difference is observed because the maximum force is not usually encountered. Overall, the clinical scenario indicates absorbable plates to be a viable option in less accessible areas. Level of Evidence: NA .


  • Measured Gain in Projection With the Extended Columellar Strut-Tip Graft in Endonasal Rhinoplasty

    by Michael A. Carron, Richard A. Zoumalan, Norman J. Pastorek

    Research from JAMA Facial Plastic Surgery — Measured Gain in Projection With the Extended Columellar Strut-Tip Graft in Endonasal Rhinoplasty


  • Open Access

    Airway Obstruction by Granulation Tissue within a Fenestrated Tracheotomy Tube: Case Report

    by Michael A. Carron, Sihun Alex Kim, Raja Sawhney, Patrick Reidy

    Complications of tracheotomy tube placement can be categorized as intraoperative, early postoperative, and late postoperative. Among the late complications is the development of granulation tissue. We describe one of the few reported cases of granulation tissue that formed within a fenestrated tracheotomy tube. In this case, the granulation tissue grew through the fenestrations, obliterated the tracheal lumen, and tethered the tube to the trachea itself. As a result, the patient required emergency treatment to restore airway patency.