Marcus Paulo Raele
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Marcus Paulo Raele has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
Lucas Ramos De Pretto
Nuclear and Energy Research Institute, IPEN-CNEN/SP, Av. Prof. Lineu Prestes, 2242, Cidade Universitária, 05508-000, São Paulo, SP, Brazil
3 shared publicationsNoé Gabriel Pinheiro Machado
Nuclear and Energy Research Institute, IPEN, CNEN/SP, Av. Prof. Lineu Prestes, São Paulo, Brazil
3 shared publicationsRoberto Vicente
IPEN-CNEN/SP, Nuclear and Energy Research Institute, São Paulo, Brasil
3 shared publicationsWagner de Rossi
Nuclear and Energy Research Institute, IPEN-CNEN/SP, São Paulo, Brasil
3 shared publications- Anderson Zanardi de Freitas
Institute for Energy and Nuclear Research, São Paulo 05508-000, Brazil
2 shared publications - Denise Maria Zezell
Center for Lasers and Applications, Instituto de Pesquisas Energéticas e Nucleares, São Paulo, Brazil
2 shared publications
Latest Publications
- Open Access
- 8 August 2026
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 335 (8) , 5021-5033
Laser decontamination of radioactive surfaces: scoping review
This review aims to consolidate and critically analyze the current knowledge on laser ablation for the decontamination of radioactive surfaces. By examining 48 manuscripts, including academic papers and technical reports, the study compares different laser regimes, materials, and contaminants in order to identify operational trends, practical guidelines, and limitations of the technique. By synthesizing dispersed experimental results, this work seeks to provide conclusions relevant to process design and to support the development of more efficient laser-based decontamination strategies for radioactive waste management.
- 8 August 2026
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 335 (8) , 5021-5033
Open AccessLaser decontamination of radioactive surfaces: scoping review
This review aims to consolidate and critically analyze the current knowledge on laser ablation for the decontamination of radioactive surfaces. By examining 48 manuscripts, including academic papers and technical reports, the study compares different laser regimes, materials, and contaminants in order to identify operational trends, practical guidelines, and limitations of the technique. By synthesizing dispersed experimental results, this work seeks to provide conclusions relevant to process design and to support the development of more efficient laser-based decontamination strategies for radioactive waste management.
- Open Access
- 24 July 2026
- Published by Wiley in Journal of Biophotonics
- Vol. 19 (7) , e70323
Comparing the Effects of Chemical Optical Clearing Agents and Mechanical Compression on the Optical Attenuation of Porcine Skin
Light scattering remains a primary challenge for deep‐tissue optical diagnostics and therapies. While Optical Clearing Agents (OCAs) are used to reduce skin attenuation, Mechanical Compression (MC) is also applied in clinical settings despite its inconclusive results. Their relative effectiveness under standardized conditions remains poorly characterized. This study quantitatively compares various OCA formulations, including mineral oil, PEG‐400, fructose, and tartrazine, with enhancers such as oleic acid and 1,2‐propanediol, under load‐dependent MC (1.6–47 kPa). Using spectral‐domain OCT at 840 nm on porcine skin, we found that PEG‐400/oleic acid (80/20%) achieved the highest efficiency, reducing the optical attenuation coefficient (OAC) by 23.8% ± 1.7% within 15 min. Fructose‐based and aqueous tartrazine formulations also showed significant reductions (16.8% and 20.4%). Conversely, our results show that MC does not effectively reduce skin optical attenuation. These findings demonstrate that OCAs provide a more potent, stable reduction in OAC, offering a superior strategy for optimizing light delivery.
- 24 July 2026
- Published by Wiley in Journal of Biophotonics
- Vol. 19 (7) , e70323
Open AccessComparing the Effects of Chemical Optical Clearing Agents and Mechanical Compression on the Optical Attenuation of Porcine Skin
Light scattering remains a primary challenge for deep‐tissue optical diagnostics and therapies. While Optical Clearing Agents (OCAs) are used to reduce skin attenuation, Mechanical Compression (MC) is also applied in clinical settings despite its inconclusive results. Their relative effectiveness under standardized conditions remains poorly characterized. This study quantitatively compares various OCA formulations, including mineral oil, PEG‐400, fructose, and tartrazine, with enhancers such as oleic acid and 1,2‐propanediol, under load‐dependent MC (1.6–47 kPa). Using spectral‐domain OCT at 840 nm on porcine skin, we found that PEG‐400/oleic acid (80/20%) achieved the highest efficiency, reducing the optical attenuation coefficient (OAC) by 23.8% ± 1.7% within 15 min. Fructose‐based and aqueous tartrazine formulations also showed significant reductions (16.8% and 20.4%). Conversely, our results show that MC does not effectively reduce skin optical attenuation. These findings demonstrate that OCAs provide a more potent, stable reduction in OAC, offering a superior strategy for optimizing light delivery.
- Open Access
- 27 January 2025
- Published by Springer Nature in Discover Nano
- Vol. 20 (1) , 1-12
Green synthesis of silica-coated gold nanoparticles employing femtosecond laser, solid targets, and water
Gold nanoparticles are widely used in biomedical applications due to their unique properties. However, traditional synthesis methods generate contaminants
- 27 January 2025
- Published by Springer Nature in Discover Nano
- Vol. 20 (1) , 1-12
Open AccessGreen synthesis of silica-coated gold nanoparticles employing femtosecond laser, solid targets, and water
Gold nanoparticles are widely used in biomedical applications due to their unique properties. However, traditional synthesis methods generate contaminants
- 21 June 2024
- Published by Springer Nature in Brazilian Journal of Physics
- Vol. 54 (5) , 1-9
Autocorrelation Optical Coherence Tomography (Au-OCT) of Complex Morphologies and Moving Samples
- 21 June 2024
- Published by Springer Nature in Brazilian Journal of Physics
- Vol. 54 (5) , 1-9
Autocorrelation Optical Coherence Tomography (Au-OCT) of Complex Morphologies and Moving Samples
- Open Access
- 10 January 2024
- Published by Sociedade Brasileira de Proteção Radiológica - SBPR in Brazilian Journal of Radiation Sciences
- Vol. 12 (1)
Development of a pulsed laser deposition system suitable for radioactive thin films growth
Radioactive thin films have a direct application in the development of beta-voltaic batteries. The main advantage of that kind of nuclear battery is its durability, which can range from a hundred years, depending on the half-life of the radioisotope used. In this context, Pulsed Laser Deposition (PLD) is an important tool. A relevant aspect of a system using this technique is that the main equipment is outside the chamber where the material is processed. Consequently, this feature allows the growth of radioactive thin films, as it enables the development of an arrangement where the contaminated area is controlled. In this way, the present work proposed the development of a PLD system for the growth of radioactive thin films. The PLD system was then implemented and radioactive copper targets were processed for 60 min and 120 min, resulting in radioactive thin films with an average thickness of (167.8 ± 3.7) nm and (313.5 ± 9.2) nm, respectively. Then, a study was performed about the radioactive contamination spread in the PLD system in order to prove if the filtering implemented was effective in retaining the contamination inside the vacuum chamber. Thus, it is demonstrated for the first time the feasibility of using the PLD technique in the growth of radioactive thin films, making its use possible in future studies on the development of beta-voltaic nuclear batteries.
- 10 January 2024
- Published by Sociedade Brasileira de Proteção Radiológica - SBPR in Brazilian Journal of Radiation Sciences
- Vol. 12 (1)
Open AccessDevelopment of a pulsed laser deposition system suitable for radioactive thin films growth
Radioactive thin films have a direct application in the development of beta-voltaic batteries. The main advantage of that kind of nuclear battery is its durability, which can range from a hundred years, depending on the half-life of the radioisotope used. In this context, Pulsed Laser Deposition (PLD) is an important tool. A relevant aspect of a system using this technique is that the main equipment is outside the chamber where the material is processed. Consequently, this feature allows the growth of radioactive thin films, as it enables the development of an arrangement where the contaminated area is controlled. In this way, the present work proposed the development of a PLD system for the growth of radioactive thin films. The PLD system was then implemented and radioactive copper targets were processed for 60 min and 120 min, resulting in radioactive thin films with an average thickness of (167.8 ± 3.7) nm and (313.5 ± 9.2) nm, respectively. Then, a study was performed about the radioactive contamination spread in the PLD system in order to prove if the filtering implemented was effective in retaining the contamination inside the vacuum chamber. Thus, it is demonstrated for the first time the feasibility of using the PLD technique in the growth of radioactive thin films, making its use possible in future studies on the development of beta-voltaic nuclear batteries.
- 29 September 2023
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 332 (11) , 4535-4540
Surface contaminants’ incorporation after nanosecond laser ablation
- 29 September 2023
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 332 (11) , 4535-4540
Surface contaminants’ incorporation after nanosecond laser ablation
- 22 October 2022
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 331 (11) , 4553-4561
Laser decontamination of surface impregnated with radioactive material
- 22 October 2022
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 331 (11) , 4553-4561
Laser decontamination of surface impregnated with radioactive material
- 1 January 2022
- Published by Optica Publishing Group
- p. W3B.2
Study on the Potential of Laser Ablation to Decontaminate Radioactive Waste
Laser is a promising tool to decontaminate radioactive waste that is impregnated with radionuclides on its surface, the decontamination process has no chemical inputs, and the pollutants can be fixed in HEPA filters. The current study aimed to test a wide range of samples using 10 different materials and fluences ranging from 1 to 10 J/cm2.
- 1 January 2022
- Published by Optica Publishing Group
- p. W3B.2
Study on the Potential of Laser Ablation to Decontaminate Radioactive Waste
Laser is a promising tool to decontaminate radioactive waste that is impregnated with radionuclides on its surface, the decontamination process has no chemical inputs, and the pollutants can be fixed in HEPA filters. The current study aimed to test a wide range of samples using 10 different materials and fluences ranging from 1 to 10 J/cm2.
- Open Access
- 12 March 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 4167
Focus Tracking System for Femtosecond Laser Machining using Low Coherence Interferometry
We designed a real time, single-laser focus tracking system using low coherence properties of the machining femtosecond laser itself in order to monitor and correct the sample position relative to the focal plane. Using a Michelson Interferometer, the system collects data arising from part of the beam backscattered at the ablation spot. The data is analyzed by a custom software for position correction (employing an XYZ automated translation stage). With the focus tracking enabled we were able to etch channels with a stable cross-section profile on a bovine tooth with relief amplitude tens of times greater than the Rayleigh length of the system, keeping the sample inside the confocal parameter during most of the processing time. Moreover, the system is also capable of monitoring crater depth evolution during the ablation process, allowing for material removal assessment.
- 12 March 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 4167
Open AccessFocus Tracking System for Femtosecond Laser Machining using Low Coherence Interferometry
We designed a real time, single-laser focus tracking system using low coherence properties of the machining femtosecond laser itself in order to monitor and correct the sample position relative to the focal plane. Using a Michelson Interferometer, the system collects data arising from part of the beam backscattered at the ablation spot. The data is analyzed by a custom software for position correction (employing an XYZ automated translation stage). With the focus tracking enabled we were able to etch channels with a stable cross-section profile on a bovine tooth with relief amplitude tens of times greater than the Rayleigh length of the system, keeping the sample inside the confocal parameter during most of the processing time. Moreover, the system is also capable of monitoring crater depth evolution during the ablation process, allowing for material removal assessment.
- 1 October 2017
- Published by Elsevier in Waste Management
- Vol. 68, 475-481
Soldering mask laser removal from printed circuit boards aiming copper recycling
- 1 October 2017
- Published by Elsevier in Waste Management
- Vol. 68, 475-481
Soldering mask laser removal from printed circuit boards aiming copper recycling