RMRuyu Ma

Ruyu Ma

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ruyu Ma has a total of 5 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

    • 1 October 2015
      • Vol. 32  (5) , 1009-12

    [Combined Probe for Determining Canal Filing Cutting Path].

    by Ruyu Ma, Hua Ding, Jinan Gu

    In order to help a surgeon to determine a proper canal filing cutting path in a hip replacement operation conveniently, this paper presents a kind of probe with combined structure. Firstly, the doctor can use this kind of combined probe to choose canal filing cutting path. Then, the doctor can use computer to guide the surgeon to file femoral cavity along the selected canal filing cutting path. Through hip replacement corpse experiments, filing effects and used time of using combined probe group and separate control group were analyzed. The experiment results showed that the methods introduced in this paper could lower the difficulty of hip replacement operations, improve the implantation of hip stem prostheses further, and reduce the incidence of surgical complications.

  • Verifying a Software System for Designing Custom Hip Stems Based on X-Ray Films

    by Ruyu Ma, Hua Ding, Jianhe Wei, Deyong Yang

    If a custom hip stem could be designed according to X-ray films, the cost of the hip stem would be reduced, and a simpler designing method could be provided than using computer tomography images. In addition, the problem, which is that hip stems cannot be designed for some revision operations because of metal artifacts in computer tomography images, could be solved. A software system for designing custom hip stems based on X-ray films was developed. In order to verify whether the software system could be used, eleven femurs were used for this study. Hip stems for these eleven femurs were designed by using the software system. Ten of these femurs were taken computer tomography scans directly. According to the data collected from the computer tomography images, models of these ten femurs were rebuilt. Ten hip stem models, designed for these ten femurs, were simulated to be inserted into corresponding femur models. Results show each of the ten hip stems matches its corresponding femur. The hip stem designed for the remaining femur was manufactured and inserted in the remaining femur. Cancellous bone, retained in the matching area, was about 1–1.5 mm thick. From the above verifications, it could be concluded that the software system for designing custom hip stems based on X-ray films could be used to design custom hip stems.