Daniele Marin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Daniele Marin has a total of 76 co-authors. Here are the top co-authors by number of shared publications:
- Fides Regina Schwartz
Department of Radiology, Brigham and Women’s Hospital, Boston, USA
4 shared publications - Rajan T. Gupta
Department of Radiology Duke University Medical Center Durham North Carolina USA
4 shared publications Rendon C. Nelson
From the Departments of Radiology (C.S., B.P., S.H., P.D., R.C.N., D.M.) and Biostatistics and Bioinformatics (A.E.F.), Duke University Medical Center, Box 3808 Erwin Rd, Durham, NC 27710; Department of Diagnostic and Interventional Radiology, University Hospital of Tuebingen, Tuebingen, Germany (C.S., K.N.); and Department of Computed Tomography, Siemens Medical Solutions USA, Malvern, Pa (J.C.R.).
4 shared publicationsAchille Mileto
From the Department of Radiology (D.M., D.D., B.P., R.T.G., A.M., R.C.N.) and Carl E. Ravin Advanced Imaging Laboratories (K.R.C.), Duke University Medical Center, Box 3808 Erwin Rd, Durham, NC 27710
3 shared publications- Benjamin Wildman-Tobriner
Department of Radiology, Duke University School of Medicine, Durham, NC
3 shared publications Christoph Schabel
From the Departments of Radiology (C.S., B.P., S.H., P.D., R.C.N., D.M.) and Biostatistics and Bioinformatics (A.E.F.), Duke University Medical Center, Box 3808 Erwin Rd, Durham, NC 27710; Department of Diagnostic and Interventional Radiology, University Hospital of Tuebingen, Tuebingen, Germany (C.S., K.N.); and Department of Computed Tomography, Siemens Medical Solutions USA, Malvern, Pa (J.C.R.).
3 shared publications
Latest Publications
- 1 September 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 11 (05) , 053502-13
Photon-counting computed tomography versus energy-integrating computed tomography for detection of small liver lesions: comparison using a virtual framework imaging
PurposePhoton-counting computed tomography (PCCT) has the potential to provide superior image quality to energy-integrating CT (EICT). We objectively compare PCCT to EICT for liver lesion detection.ApproachFifty anthropomorphic, computational phantoms with inserted liver lesions were generated. Contrast-enhanced scans of each phantom were simulated at the portal venous phase. The acquisitions were done using DukeSim, a validated CT simulation platform. Scans were simulated at two dose levels (CTDIvol 1.5 to 6.0 mGy) modeling PCCT (NAEOTOM Alpha, Siemens, Erlangen, Germany) and EICT (SOMATOM Flash, Siemens). Images were reconstructed with varying levels of kernel sharpness (soft, medium, sharp). To provide a quantitative estimate of image quality, the modulation transfer function (MTF), frequency at 50% of the MTF (f50), noise magnitude, contrast-to-noise ratio (CNR, per lesion), and detectability index (d′, per lesion) were measured.ResultsAcross all studied conditions, the best detection performance, measured by d′, was for PCCT images with the highest dose level and softest kernel. With soft kernel reconstruction, PCCT demonstrated improved lesion CNR and d′ compared with EICT, with a mean increase in CNR of 35.0% (p<0.001) and 21% (p<0.001) and a mean increase in d′ of 41.0% (p<0.001) and 23.3% (p=0.007) for the 1.5 and 6.0 mGy acquisitions, respectively. The improvements were greatest for larger phantoms, low-contrast lesions, and low-dose scans.ConclusionsPCCT demonstrated objective improvement in liver lesion detection and image quality metrics compared with EICT. These advances may lead to earlier and more accurate liver lesion detection, thus improving patient care.
- 1 September 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 11 (05) , 053502-13
Photon-counting computed tomography versus energy-integrating computed tomography for detection of small liver lesions: comparison using a virtual framework imaging
PurposePhoton-counting computed tomography (PCCT) has the potential to provide superior image quality to energy-integrating CT (EICT). We objectively compare PCCT to EICT for liver lesion detection.ApproachFifty anthropomorphic, computational phantoms with inserted liver lesions were generated. Contrast-enhanced scans of each phantom were simulated at the portal venous phase. The acquisitions were done using DukeSim, a validated CT simulation platform. Scans were simulated at two dose levels (CTDIvol 1.5 to 6.0 mGy) modeling PCCT (NAEOTOM Alpha, Siemens, Erlangen, Germany) and EICT (SOMATOM Flash, Siemens). Images were reconstructed with varying levels of kernel sharpness (soft, medium, sharp). To provide a quantitative estimate of image quality, the modulation transfer function (MTF), frequency at 50% of the MTF (f50), noise magnitude, contrast-to-noise ratio (CNR, per lesion), and detectability index (d′, per lesion) were measured.ResultsAcross all studied conditions, the best detection performance, measured by d′, was for PCCT images with the highest dose level and softest kernel. With soft kernel reconstruction, PCCT demonstrated improved lesion CNR and d′ compared with EICT, with a mean increase in CNR of 35.0% (p<0.001) and 21% (p<0.001) and a mean increase in d′ of 41.0% (p<0.001) and 23.3% (p=0.007) for the 1.5 and 6.0 mGy acquisitions, respectively. The improvements were greatest for larger phantoms, low-contrast lesions, and low-dose scans.ConclusionsPCCT demonstrated objective improvement in liver lesion detection and image quality metrics compared with EICT. These advances may lead to earlier and more accurate liver lesion detection, thus improving patient care.
- 28 March 2024
- Published by Springer Nature in Abdominal Radiology
- Vol. 49 (5) , 1762-1770
Protocol optimization for abdominal imaging using photon-counting CT: a consensus of two academic institutions
Purpose Photon-counting detector CT (PCD CT) is a promising technology for abdominal imaging due to its ability to provide high spatial and contrast resolution images with reduced patient radiation exposure. However, there is currently no consensus regarding the optimal imaging protocols for PCD CT. This article aims to present the PCD CT abdominal imaging protocols used by two tertiary care academic centers in the United States. Methods A review of PCD CT abdominal imaging protocols was conducted by two abdominal radiologists at different academic institutions. Protocols were compared in terms of acquisition parameters and reconstruction settings. Both imaging centers independently selected similar protocols for PCD CT abdominal imaging, using QuantumPlus mode. Results There were some differences in the use of reconstruction kernels and iterative reconstruction levels, however the individual combination at each site resulted in similar image impressions. Overall, the imaging protocols used by both centers provide high-quality images with low radiation exposure. Conclusion These findings provide valuable insights into the development of standardized protocols for PCD CT abdominal imaging, which can help to ensure consistent as well as high-quality imaging across different institutions and allow for future multicenter research collaborations.
- 28 March 2024
- Published by Springer Nature in Abdominal Radiology
- Vol. 49 (5) , 1762-1770
Protocol optimization for abdominal imaging using photon-counting CT: a consensus of two academic institutions
Purpose Photon-counting detector CT (PCD CT) is a promising technology for abdominal imaging due to its ability to provide high spatial and contrast resolution images with reduced patient radiation exposure. However, there is currently no consensus regarding the optimal imaging protocols for PCD CT. This article aims to present the PCD CT abdominal imaging protocols used by two tertiary care academic centers in the United States. Methods A review of PCD CT abdominal imaging protocols was conducted by two abdominal radiologists at different academic institutions. Protocols were compared in terms of acquisition parameters and reconstruction settings. Both imaging centers independently selected similar protocols for PCD CT abdominal imaging, using QuantumPlus mode. Results There were some differences in the use of reconstruction kernels and iterative reconstruction levels, however the individual combination at each site resulted in similar image impressions. Overall, the imaging protocols used by both centers provide high-quality images with low radiation exposure. Conclusion These findings provide valuable insights into the development of standardized protocols for PCD CT abdominal imaging, which can help to ensure consistent as well as high-quality imaging across different institutions and allow for future multicenter research collaborations.
- 25 September 2023
- Published by Elsevier in Radiologic Clinics of North America
- Vol. 61 (6)
Unveiling the Spectrum: Dual-Energy Computed Tomography and Beyond!
- 25 September 2023
- Published by Elsevier in Radiologic Clinics of North America
- Vol. 61 (6)
Unveiling the Spectrum: Dual-Energy Computed Tomography and Beyond!
- 26 July 2023
- Published by Elsevier in European Journal of Radiology
- Vol. 166, 111014
Image quality of photon counting and energy integrating chest CT – Prospective head-to-head comparison on same patients
- 26 July 2023
- Published by Elsevier in European Journal of Radiology
- Vol. 166, 111014
Image quality of photon counting and energy integrating chest CT – Prospective head-to-head comparison on same patients
- 22 July 2023
- Published by Elsevier in European Journal of Radiology
- Vol. 166, 110998
Optimization of non-endorectal prostate MR image quality using PI-QUAL: A multidisciplinary team approach
- 22 July 2023
- Published by Elsevier in European Journal of Radiology
- Vol. 166, 110998
Optimization of non-endorectal prostate MR image quality using PI-QUAL: A multidisciplinary team approach
- 9 February 2023
- Published by Elsevier in European Journal of Radiology
- Vol. 161, 110734
Liver fat quantification in photon counting CT in head to head comparison with clinical MRI – First experience
- 9 February 2023
- Published by Elsevier in European Journal of Radiology
- Vol. 161, 110734
Liver fat quantification in photon counting CT in head to head comparison with clinical MRI – First experience
- 24 April 2021
- Published by Elsevier in European Journal of Radiology
- Vol. 139, 109734
Evaluating renal lesions using deep-learning based extension of dual-energy FoV in dual-source CT—A retrospective pilot study
- 24 April 2021
- Published by Elsevier in European Journal of Radiology
- Vol. 139, 109734
Evaluating renal lesions using deep-learning based extension of dual-energy FoV in dual-source CT—A retrospective pilot study
- 19 September 2020
- Published by Springer Nature in Abdominal Radiology
- Vol. 46 (3) , 969-978
How frequently does hepatocellular carcinoma develop in at-risk patients with a negative liver MRI examination with intravenous Gadobenate dimeglumine?
Objective To determine the rate of development of clinically significant liver nodules (LR-4, LR-5, LR-M) after a negative MRI in an HCC screening population. Methods This retrospective study included patients at risk of developing HCC requiring imaging surveillance who had undergone multiphase Gadobenate dimeglumine-enhanced MRI that was negative and had follow up LI-RADS compliant multiphase CTs or MRIs for at least 12 months or positive follow-up within 12 months. Follow-up examinations were classified as negative (no nodules or only LR-1 nodules) or positive (nodule other than LR-1). Time-to-first positive examination, types of nodules, and cumulative incidence of nodule development were recorded. Results 204 patients (mean age 58.9 ± 10.2 years, 128 women), including 172 with cirrhosis, were included. Based CT/MRI follow-up (median 35 months, range 12–80 months), the overall cumulative incidence of developing a nodule was 10.5%. Cumulative incidence of nodule development was: 0.5% at 6–9 months and 2.1% at 12 ± 3 months, including one LR-4 nodule, one LR-M nodule, and two LR-3 nodules. The cumulative incidence of clinically significant nodule development was 1.1% at 9–15 months. 70% (143/204) of patients also underwent at least one US follow-up, and no patient developed a positive US examination following index negative MRI. Conclusion Clinically significant liver nodules develop in 1.1% of at-risk patients in the first year following negative MRI. While ongoing surveillance is necessary for at-risk patients, our study suggests than longer surveillance intervals after a negative MRI may be reasonable and that further research is needed to explore this possibility.
- 19 September 2020
- Published by Springer Nature in Abdominal Radiology
- Vol. 46 (3) , 969-978
How frequently does hepatocellular carcinoma develop in at-risk patients with a negative liver MRI examination with intravenous Gadobenate dimeglumine?
Objective To determine the rate of development of clinically significant liver nodules (LR-4, LR-5, LR-M) after a negative MRI in an HCC screening population. Methods This retrospective study included patients at risk of developing HCC requiring imaging surveillance who had undergone multiphase Gadobenate dimeglumine-enhanced MRI that was negative and had follow up LI-RADS compliant multiphase CTs or MRIs for at least 12 months or positive follow-up within 12 months. Follow-up examinations were classified as negative (no nodules or only LR-1 nodules) or positive (nodule other than LR-1). Time-to-first positive examination, types of nodules, and cumulative incidence of nodule development were recorded. Results 204 patients (mean age 58.9 ± 10.2 years, 128 women), including 172 with cirrhosis, were included. Based CT/MRI follow-up (median 35 months, range 12–80 months), the overall cumulative incidence of developing a nodule was 10.5%. Cumulative incidence of nodule development was: 0.5% at 6–9 months and 2.1% at 12 ± 3 months, including one LR-4 nodule, one LR-M nodule, and two LR-3 nodules. The cumulative incidence of clinically significant nodule development was 1.1% at 9–15 months. 70% (143/204) of patients also underwent at least one US follow-up, and no patient developed a positive US examination following index negative MRI. Conclusion Clinically significant liver nodules develop in 1.1% of at-risk patients in the first year following negative MRI. While ongoing surveillance is necessary for at-risk patients, our study suggests than longer surveillance intervals after a negative MRI may be reasonable and that further research is needed to explore this possibility.