Elena Zemova
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Elena Zemova has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Berthold Seitz
Department of Ophthalmology, Saarland University Medical Center, Homburg/Saar, Germany
3 shared publications - Timo Eppig
AMIPLANT GmbH, Haidling 1, Schnaittach, 91220, Germany; Institut für Experimentelle Ophthalmologie, Universität des Saarlandes, Kirrberger Str. 100, Homburg/Saar, 66424, Germany
3 shared publications - Achim Langenbucher
Department of Experimental Ophthalmology, Saarland University, Homburg/Saar, Germany
2 shared publications Nóra Szentmáry
Department of Ophthalmology, Saarland University Medical Center, Homburg/Saar, Germany
2 shared publicationsAchim Langenbucher
Experimental Ophthalmology, Saarland University Homburg/SaarGermany; Institute of Medical Biometry, Epidemiology and Medical Informatics, Saarland University Medical Center Homburg/SaarGermany
1 shared publicationBenjamin Mauer
1 shared publication
Latest Publications
- 1 September 2015
- Published by Elsevier in Zeitschrift für Medizinische Physik
- Vol. 25 (3) , 243-250
Correlation of corneal thickness, endothelial cell density and anterior chamber depth with ocular surface temperature in normal subjects
- 1 September 2015
- Published by Elsevier in Zeitschrift für Medizinische Physik
- Vol. 25 (3) , 243-250
Correlation of corneal thickness, endothelial cell density and anterior chamber depth with ocular surface temperature in normal subjects
- 14 June 2013
- Published by Taylor & Francis in Current Eye Research
- Vol. 39 (1) , 1-8
Interaction Between Topographic/Tomographic Parameters and Dry Eye Disease in Keratoconus Patients
Purpose: To determine the interaction between corneal topographic and tomographic parameters and dry eye syndrome (DES) in keratoconus (KC) patients. Methods: Seventy-seven eyes of 49 patients with KC (age 34.4 ± 11.6 years) were enrolled in this study. In these 77 eyes we recorded surface regularity index (SRI), surface asymmetry index (SAI) and Klyce/Maeda KC index (KCI) using the Topographic Modeling System (TMS-5, Tomey, Tennenlohe, Germany), Index of Surface Variance (ISV), Index of Vertical Asymmetry (IVA), KC Index (KI), Center KC Index (CKI), Index of Height Asymmetry (IHA) and Index of Height Decentration (IHD) using Pentacam (Pentacam HR, Oculus, Germany). Patients were subdivided into mild (grade 1–2) and severe stage (grade 3–4) KC groups according to Pentacam grading. To analyse tear film parameters we assessed in 77 KC eyes McMonnies questionnaire, Schirmer test and break-up time and in 26 eyes (10 eyes with mild KC, 16 eyes with severe KC) high-speed videokeratoscopy (during interblinking interval) using a novel commercially not available system (Tear Inspect). With Tear Inspect the analysed tear film parameters were (1) time of first irregularities of Placido rings and (2) time of eyelid closure. Patients were also subdivided into McMonnies questionnaire positive and negative groups. Results: We did not find significant difference between patients with mild and severe KC in any of the examined tear film parameters (p > 0.66). There was no significant difference in SRI, SAI, KCI, ISV, IVA, KI, CKI, IHA and IHD in McMonnies test positive and negative KC patients (p > 0.07). There was no correlation between SRI, SAI, KCI, ISV, IVA, KI, CKI, IHA and IHD and any of the examined tear film parameters (without high-speed videokeratoscopy) neither in 77 KC patients nor in mild or severe KC eyes (r < 0.3). Conclusions: There is no interaction between DES and topographic/tomographic changes in KC-patients.
- 14 June 2013
- Published by Taylor & Francis in Current Eye Research
- Vol. 39 (1) , 1-8
Interaction Between Topographic/Tomographic Parameters and Dry Eye Disease in Keratoconus Patients
Purpose: To determine the interaction between corneal topographic and tomographic parameters and dry eye syndrome (DES) in keratoconus (KC) patients. Methods: Seventy-seven eyes of 49 patients with KC (age 34.4 ± 11.6 years) were enrolled in this study. In these 77 eyes we recorded surface regularity index (SRI), surface asymmetry index (SAI) and Klyce/Maeda KC index (KCI) using the Topographic Modeling System (TMS-5, Tomey, Tennenlohe, Germany), Index of Surface Variance (ISV), Index of Vertical Asymmetry (IVA), KC Index (KI), Center KC Index (CKI), Index of Height Asymmetry (IHA) and Index of Height Decentration (IHD) using Pentacam (Pentacam HR, Oculus, Germany). Patients were subdivided into mild (grade 1–2) and severe stage (grade 3–4) KC groups according to Pentacam grading. To analyse tear film parameters we assessed in 77 KC eyes McMonnies questionnaire, Schirmer test and break-up time and in 26 eyes (10 eyes with mild KC, 16 eyes with severe KC) high-speed videokeratoscopy (during interblinking interval) using a novel commercially not available system (Tear Inspect). With Tear Inspect the analysed tear film parameters were (1) time of first irregularities of Placido rings and (2) time of eyelid closure. Patients were also subdivided into McMonnies questionnaire positive and negative groups. Results: We did not find significant difference between patients with mild and severe KC in any of the examined tear film parameters (p > 0.66). There was no significant difference in SRI, SAI, KCI, ISV, IVA, KI, CKI, IHA and IHD in McMonnies test positive and negative KC patients (p > 0.07). There was no correlation between SRI, SAI, KCI, ISV, IVA, KI, CKI, IHA and IHD and any of the examined tear film parameters (without high-speed videokeratoscopy) neither in 77 KC patients nor in mild or severe KC eyes (r < 0.3). Conclusions: There is no interaction between DES and topographic/tomographic changes in KC-patients.
- 1 November 2012
- Published by SLACK, Inc. in Ophthalmic Surgery, Lasers and Imaging Retina
- Vol. 43 (6) , 467-471
Elevated Intraocular Pressure in the Early Postoperative Period Following Excimer Laser Penetrating Keratoplasty for Keratoconus
Clinical Science Zisis Gatzioufas, MD, PhD; Georgios Labiris, MD, PhD; Benjamin Mauer, MD; Elena Zemova, MD; Timo Eppig, MD, PhD; Achim Langenbucher, MD, PhD; Berthold Seitz, MD, PhD To assess the incidence of elevated intraocular pressure (IOP) in the early postoperative period after excimer laser penetrating keratoplasty for keratoconus and reveal potential associations with anterior segment parameters. This prospective, interventional study consisted of 40 patients with keratoconus who were treated with excimer laser penetrating keratoplasty. Corneal pachymetry, anterior chamber depth, anterior chamber volume, and anterior segment angle were measured by Scheimpflug camera preoperatively and 2 months postoperatively. IOP was obtained using Goldmann applanation tonometry. Student’s t tests and Pearson correlation were applied. A P value of .05 or less was considered significant. IOP increased from 16.3 ± 3.5 preoperatively to 19.3 ± 5.2 mm Hg postoperatively (P = .007). Significant differences were detected in corneal pachymetry (P < .008), anterior chamber depth (P < .001), and anterior chamber volume (P = .03). Postoperative IOP was significantly correlated with anterior segment angle, anterior chamber depth, and corneal pachymetry. Elevated IOP in the early postoperative period after excimer laser penetrating keratoplasty is significantly correlated with changes in the anterior chamber architecture. From the Department of Ophthalmology (ZG, GL, BM, EZ, BS), University Medical Center of Saarland UKS; and Experimental Ophthalmology (TE, AL), University of Saarland, Homburg, Saar, Germany. The authors have no financial or proprietary interest in the materials presented herein. Address correspondence to Zisis Gatzioufas, MD, PhD, Department of Ophthalmology, University Medical Center of Saarland UKS, Kirrberger Str. 1, 66424 Homburg, Saar, Germany. E-mail: zisis.gkatzioufas@uks.eu 10.3928/15428877-20121002-01 Healio is intended for health care provider use and all comments will be posted at the discretion of the editors. We reserve the right not to post any comments with unsolicited information about medical devices or other products. At no time will Healio be used for medical advice to patients.
- 1 November 2012
- Published by SLACK, Inc. in Ophthalmic Surgery, Lasers and Imaging Retina
- Vol. 43 (6) , 467-471
Elevated Intraocular Pressure in the Early Postoperative Period Following Excimer Laser Penetrating Keratoplasty for Keratoconus
Clinical Science Zisis Gatzioufas, MD, PhD; Georgios Labiris, MD, PhD; Benjamin Mauer, MD; Elena Zemova, MD; Timo Eppig, MD, PhD; Achim Langenbucher, MD, PhD; Berthold Seitz, MD, PhD To assess the incidence of elevated intraocular pressure (IOP) in the early postoperative period after excimer laser penetrating keratoplasty for keratoconus and reveal potential associations with anterior segment parameters. This prospective, interventional study consisted of 40 patients with keratoconus who were treated with excimer laser penetrating keratoplasty. Corneal pachymetry, anterior chamber depth, anterior chamber volume, and anterior segment angle were measured by Scheimpflug camera preoperatively and 2 months postoperatively. IOP was obtained using Goldmann applanation tonometry. Student’s t tests and Pearson correlation were applied. A P value of .05 or less was considered significant. IOP increased from 16.3 ± 3.5 preoperatively to 19.3 ± 5.2 mm Hg postoperatively (P = .007). Significant differences were detected in corneal pachymetry (P < .008), anterior chamber depth (P < .001), and anterior chamber volume (P = .03). Postoperative IOP was significantly correlated with anterior segment angle, anterior chamber depth, and corneal pachymetry. Elevated IOP in the early postoperative period after excimer laser penetrating keratoplasty is significantly correlated with changes in the anterior chamber architecture. From the Department of Ophthalmology (ZG, GL, BM, EZ, BS), University Medical Center of Saarland UKS; and Experimental Ophthalmology (TE, AL), University of Saarland, Homburg, Saar, Germany. The authors have no financial or proprietary interest in the materials presented herein. Address correspondence to Zisis Gatzioufas, MD, PhD, Department of Ophthalmology, University Medical Center of Saarland UKS, Kirrberger Str. 1, 66424 Homburg, Saar, Germany. E-mail: zisis.gkatzioufas@uks.eu 10.3928/15428877-20121002-01 Healio is intended for health care provider use and all comments will be posted at the discretion of the editors. We reserve the right not to post any comments with unsolicited information about medical devices or other products. At no time will Healio be used for medical advice to patients.