Amol Kumar Singh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Amol Kumar Singh has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Ahsan Uddin
Department of Electrical Engineering University of South Carolina Columbia SC 29208 USA
1 shared publication- Ahsan Uddin
Department of Electrical and Computer Engineering, Clemson University, Clemson, SC, USA
1 shared publication Goutam Koley
Department of Electrical Engineering University of South Carolina Columbia SC 29208 USA
1 shared publication- Goutam Koley
Holcombe Department of Electrical and Computer Engineering, Clemson University, Clemson, SC 29634, USA
1 shared publication Tangali S Sudarshan
1 shared publicationTangali Sudarshan
Department of Electrical Engineering University of South Carolina Columbia SC 29208 USA
1 shared publication
Latest Publications
- 25 February 2014
- Published by IOP Publishing in Nanotechnology
- Vol. 25 (12) , 125501
Functionalized graphene/silicon chemi-diode H2 sensor with tunable sensitivity
A reverse bias tunable Pd- and Pt-functionalized graphene/Si heterostructure Schottky diode H2 sensor has been demonstrated. Compared to the graphene chemiresistor sensor, the chemi-diode sensor offers more than one order of magnitude higher sensitivity as the molecular adsorption induced Schottky barrier height change causes the heterojunction current to vary exponentially in reverse bias. The reverse bias operation also enables low power consumption, as well as modulation of the atomically thin graphene's Fermi level, leading to tunable sensitivity and detection of H₂ down to the sub-ppm range.
- 25 February 2014
- Published by IOP Publishing in Nanotechnology
- Vol. 25 (12) , 125501
Functionalized graphene/silicon chemi-diode H2 sensor with tunable sensitivity
A reverse bias tunable Pd- and Pt-functionalized graphene/Si heterostructure Schottky diode H2 sensor has been demonstrated. Compared to the graphene chemiresistor sensor, the chemi-diode sensor offers more than one order of magnitude higher sensitivity as the molecular adsorption induced Schottky barrier height change causes the heterojunction current to vary exponentially in reverse bias. The reverse bias operation also enables low power consumption, as well as modulation of the atomically thin graphene's Fermi level, leading to tunable sensitivity and detection of H₂ down to the sub-ppm range.
Tunable Reverse‐Biased Graphene/Silicon Heterojunction Schottky Diode Sensor
A new chemical sensor based on reverse‐biased graphene/Si heterojunction diode has been developed that exhibits extremely high bias‐dependent molecular detection sensitivity and low operating power. The device takes advantage of graphene's atomically thin nature, which enables molecular adsorption on its surface to directly alter graphene/Si interface barrier height, thus affecting the junction current exponentially when operated in reverse bias and resulting in ultrahigh sensitivity. By operating the device in reverse bias, the work function of graphene, and hence the barrier height at the graphene/Si heterointerface, can be controlled by the bias magnitude, leading to a wide tunability of the molecular detection sensitivity. Such sensitivity control is also possible by carefully selecting the graphene/Si heterojunction Schottky barrier height. Compared to a conventional graphene amperometric sensor fabricated on the same chip, the proposed sensor demonstrated 13 times higher sensitivity for NO2 and 3 times higher for NH3 in ambient conditions, while consuming ∼500 times less power for same magnitude of applied voltage bias. The sensing mechanism based on heterojunction Schottky barrier height change has been confirmed using capacitance‐voltage measurements.
Tunable Reverse‐Biased Graphene/Silicon Heterojunction Schottky Diode Sensor
A new chemical sensor based on reverse‐biased graphene/Si heterojunction diode has been developed that exhibits extremely high bias‐dependent molecular detection sensitivity and low operating power. The device takes advantage of graphene's atomically thin nature, which enables molecular adsorption on its surface to directly alter graphene/Si interface barrier height, thus affecting the junction current exponentially when operated in reverse bias and resulting in ultrahigh sensitivity. By operating the device in reverse bias, the work function of graphene, and hence the barrier height at the graphene/Si heterointerface, can be controlled by the bias magnitude, leading to a wide tunability of the molecular detection sensitivity. Such sensitivity control is also possible by carefully selecting the graphene/Si heterojunction Schottky barrier height. Compared to a conventional graphene amperometric sensor fabricated on the same chip, the proposed sensor demonstrated 13 times higher sensitivity for NO2 and 3 times higher for NH3 in ambient conditions, while consuming ∼500 times less power for same magnitude of applied voltage bias. The sensing mechanism based on heterojunction Schottky barrier height change has been confirmed using capacitance‐voltage measurements.