Erica Menegatti
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Erica Menegatti has a total of 59 co-authors. Here are the top co-authors by number of shared publications:
- Anna Maria Malagoni
Vascular Diseases Center, University of Ferrara, Ferrara, Italy
9 shared publications F Salvi
6 shared publicationsI Bartolomei
6 shared publicationsP Zamboni
6 shared publications- Claudiu Schirda
Department of Psychiatry, Western Psychiatric Institute and Clinic, University of Pittsburgh Medical Center, University of Pittsburgh, United States
5 shared publications R Galeotti
5 shared publications
Latest Publications
- 17 January 2018
- Published by Bentham Science Publishers Ltd. in Current Neurovascular Research
- Vol. 14  (4) , 316-322
High Resolution M-mode Evaluation of Jugular Vein Valves in Patients with Neurological and Neurosensory Disorders
Abstract: Background: High prevalence of valve absence was found in the internal jugular vein (IJV) of healthy volunteers by means of M-mode high-resolution Echo Colour Doppler (ECD). However, the prevalence of valve in neurovascular disorders linked to Chronic Cerebrospinal Venous Insufficiency (CCSVI) is still unknown. Methods: A cohort of 83 Healthy Controls (HC), 71 Multiple Sclerosis (MS), 99 Inner Ear Disorders (IED) underwent ECD investigation of the IJV valve, including M-mode evaluation and related hemodynamics. The primary outcome measure was characterization of valve presence, morphology and motility, whereas the secondary outcome was the rate of flow alteration. Results: Bilateral valve presence was found in 38% of HC, 58% of MS and 25% of IED, whereas, bilateral valve absence was recorded in 16% of HC, 10% of MS and 31% of IED (p Finally, by stratifying the entire cohort according to the presence of mobile and not mobile valve leaflets, normal monodirectional and phasic flow were commonly found in the mobile leaflets subgroup, p Conclusion: In patients with miscellaneous neurological disorders, a significant higher rate of defective valves was found with respect to HC. The latter condition is strongly associated to brain outflow abnormalities described in CCSVI condition.
- 17 January 2018
- Published by Bentham Science Publishers Ltd. in Current Neurovascular Research
- Vol. 14  (4) , 316-322
High Resolution M-mode Evaluation of Jugular Vein Valves in Patients with Neurological and Neurosensory Disorders
Abstract: Background: High prevalence of valve absence was found in the internal jugular vein (IJV) of healthy volunteers by means of M-mode high-resolution Echo Colour Doppler (ECD). However, the prevalence of valve in neurovascular disorders linked to Chronic Cerebrospinal Venous Insufficiency (CCSVI) is still unknown. Methods: A cohort of 83 Healthy Controls (HC), 71 Multiple Sclerosis (MS), 99 Inner Ear Disorders (IED) underwent ECD investigation of the IJV valve, including M-mode evaluation and related hemodynamics. The primary outcome measure was characterization of valve presence, morphology and motility, whereas the secondary outcome was the rate of flow alteration. Results: Bilateral valve presence was found in 38% of HC, 58% of MS and 25% of IED, whereas, bilateral valve absence was recorded in 16% of HC, 10% of MS and 31% of IED (p Finally, by stratifying the entire cohort according to the presence of mobile and not mobile valve leaflets, normal monodirectional and phasic flow were commonly found in the mobile leaflets subgroup, p Conclusion: In patients with miscellaneous neurological disorders, a significant higher rate of defective valves was found with respect to HC. The latter condition is strongly associated to brain outflow abnormalities described in CCSVI condition.
- Open Access
- 31 May 2014
- Published by Bentham Science Publishers Ltd. in Current Neurovascular Research
- Vol. 11  (2) , 149-155
Human Internal Jugular Valve M-mode Ultrasound Characterization
In humans the mechanism governing the internal jugular vein (IJV) valve opening and closure is still unclear. M-mode is used in echo-cardiology for the heart valves assessment. Sometimes it was performed also in deep peripheral veins and in vena cava assessment, but never in the IJV valve. Aim of the present study is to investigate the IJV valves physiology in healthy volunteers, by means of both B and M-mode ultrasound. Eighty-three (83) healthy volunteers (35 Male, 48 Female, 25.7±6.7 y.o.), for a total of 166 IJVs, were enrolled. The entire cohort underwent IJVs high-resolution B and M-mode evaluation, in standardized postural and respiratory conditions. Presence, motility, and number of cusps, as well as their opening and closure mechanism have been assessed. Bilateral valve absence occurred in 13/83 (16%), whereas at least a one side absence was recorded in 38/83 (46% of the cohort) (p<0.0356). Valve leaflets were always mobile and respectively bi-cusps in 34%, or mono-cusp in 27%. The latter was significantly more frequent on the left side (35%) than on the right side (19%) (p<0.0013). In supine, M-mode valve opening was synchronous with the cardiac cycle. To the contrary, in an upright position, the valve remained always open and saddled to the wall, independently from the cardiac cycle. In healthy subjects, the IJV valve leaflets are always mobile, but the significant rate of mono and bilateral absence could suggest a progressive phylogenetic importance loss of such apparatus. M-mode ultrasound enhances the characterization of IJV valve, for this reason it should be taken into consideration to routinely add it to the cerebral venous return investigation.
- 31 May 2014
- Published by Bentham Science Publishers Ltd. in Current Neurovascular Research
- Vol. 11  (2) , 149-155
Open AccessHuman Internal Jugular Valve M-mode Ultrasound Characterization
In humans the mechanism governing the internal jugular vein (IJV) valve opening and closure is still unclear. M-mode is used in echo-cardiology for the heart valves assessment. Sometimes it was performed also in deep peripheral veins and in vena cava assessment, but never in the IJV valve. Aim of the present study is to investigate the IJV valves physiology in healthy volunteers, by means of both B and M-mode ultrasound. Eighty-three (83) healthy volunteers (35 Male, 48 Female, 25.7±6.7 y.o.), for a total of 166 IJVs, were enrolled. The entire cohort underwent IJVs high-resolution B and M-mode evaluation, in standardized postural and respiratory conditions. Presence, motility, and number of cusps, as well as their opening and closure mechanism have been assessed. Bilateral valve absence occurred in 13/83 (16%), whereas at least a one side absence was recorded in 38/83 (46% of the cohort) (p<0.0356). Valve leaflets were always mobile and respectively bi-cusps in 34%, or mono-cusp in 27%. The latter was significantly more frequent on the left side (35%) than on the right side (19%) (p<0.0013). In supine, M-mode valve opening was synchronous with the cardiac cycle. To the contrary, in an upright position, the valve remained always open and saddled to the wall, independently from the cardiac cycle. In healthy subjects, the IJV valve leaflets are always mobile, but the significant rate of mono and bilateral absence could suggest a progressive phylogenetic importance loss of such apparatus. M-mode ultrasound enhances the characterization of IJV valve, for this reason it should be taken into consideration to routinely add it to the cerebral venous return investigation.
- 1 December 2013
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
- Vol. 46  (6) , 734
Re. ‘Doppler Ultrasound Examination of Multiple Sclerosis Patients and Control Participants: Inter-observer Agreement and Association with Disease’
- 1 December 2013
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
- Vol. 46  (6) , 734
Re. ‘Doppler Ultrasound Examination of Multiple Sclerosis Patients and Control Participants: Inter-observer Agreement and Association with Disease’
- Open Access
- 11 July 2013
- Published by Springer Nature in BMC Neurology
- Vol. 13  (1) , 1-10
An ultrasound model to calculate the brain blood outflow through collateral vessels: a pilot study
The quantification of the flow returning from the head through the cervical veins and the collaterals of the internal jugular vein (IJV), is becoming of prominent interest in clinical practice. We developed a novel model to calculate the cerebral venous return, normalized to the arterial inflow, in the different segments of the IJV. We assessed, by established Echo Colour Doppler (ECD) methodology, the head inflow (HBinF) defined as the sum of common carotids and vertebral arteries, as well as the cerebral flow (CBF) defined as the sum of internal carotid and vertebral arteries. We also assessed the head outflow (HBoutF) defined as the sum of the measurements at the junction of the IJV and the vertebral veins. In addition, we also calculated the collateral flow index (CFI) by estimating the flow which re-enters directly into the superior vena cava as the amount of blood extrapolated by the difference between the HBinF and the HBoutF. We preliminarily tested the model by comparing ten healthy controls (HC) with ten patients affected by chronic cerebral spinal venous insufficiency (CCSVI), a condition characterized by some blockages in the IJV which are bypassed by collateral circulation. In HC the HBinF was 956+-105ml/min, whereas the HBoutF was > 90% of the HBinF, leading to a final CFI value of 1%. The last result shows that a very small amount of blood is drained by the collaterals. In upright we confirmed a reduction of the outflow through the IJV which increased CFI to 9%. When we applied the model to CCSVI, the HBinF was not significantly different from controls. In supine, the flow of CCSVI patients in the IJV junction was significantly lower (p < 0.001) while the correspondent CFI value significantly increased (61%, p < 0.0002). Our preliminary application of the novel model in the clinical setting suggests the pivotal role of the collateral network in draining the blood into the superior vena cava under CCSVI condition.
- 11 July 2013
- Published by Springer Nature in BMC Neurology
- Vol. 13  (1) , 1-10
Open AccessAn ultrasound model to calculate the brain blood outflow through collateral vessels: a pilot study
The quantification of the flow returning from the head through the cervical veins and the collaterals of the internal jugular vein (IJV), is becoming of prominent interest in clinical practice. We developed a novel model to calculate the cerebral venous return, normalized to the arterial inflow, in the different segments of the IJV. We assessed, by established Echo Colour Doppler (ECD) methodology, the head inflow (HBinF) defined as the sum of common carotids and vertebral arteries, as well as the cerebral flow (CBF) defined as the sum of internal carotid and vertebral arteries. We also assessed the head outflow (HBoutF) defined as the sum of the measurements at the junction of the IJV and the vertebral veins. In addition, we also calculated the collateral flow index (CFI) by estimating the flow which re-enters directly into the superior vena cava as the amount of blood extrapolated by the difference between the HBinF and the HBoutF. We preliminarily tested the model by comparing ten healthy controls (HC) with ten patients affected by chronic cerebral spinal venous insufficiency (CCSVI), a condition characterized by some blockages in the IJV which are bypassed by collateral circulation. In HC the HBinF was 956+-105ml/min, whereas the HBoutF was > 90% of the HBinF, leading to a final CFI value of 1%. The last result shows that a very small amount of blood is drained by the collaterals. In upright we confirmed a reduction of the outflow through the IJV which increased CFI to 9%. When we applied the model to CCSVI, the HBinF was not significantly different from controls. In supine, the flow of CCSVI patients in the IJV junction was significantly lower (p < 0.001) while the correspondent CFI value significantly increased (61%, p < 0.0002). Our preliminary application of the novel model in the clinical setting suggests the pivotal role of the collateral network in draining the blood into the superior vena cava under CCSVI condition.
- 1 December 2011
- Vol. 30  (6) , 571-97
Screening for chronic cerebrospinal venous insufficiency (CCSVI) using ultrasound--recommendations for a protocol.
Chronic cerebrospinal venous insufficiency (CCSVI) is a syndrome characterized by stenoses or obstructions of the internal jugular and/or azygos veins with disturbed flow and formation of collateral venous channels. Studies using ultrasound in patients with multiple sclerosis (MS) have demonstrated a high prevalence of CCSVI (mean 70%; range 0-100%; N.=1496), whereas, in normal controls and patients without MS the prevalence was much lower (mean 10%; range 0-36%; N.=635). Ultrasound uses a combination of physiological measurements as well as anatomical imaging and has been used for the detection of CCSVI by different centers with variable results. A high prevalence ranging from 62% to 100% of obstructive lesions has been found by some teams in patients with MS compared with a lower prevalence of 0-25% in controls. However, absence of such lesions or a lower prevalence (16-52%) has been reported by others. This variability could be the result of differences in technique, training, experience or criteria used. The current lack of a methodology shared among experts is a confounding element in epidemiologic studies, and does not permit further Bayesan or other kind of analysis. In order to ensure a high reproducibility of Duplex scanning with comparable accuracy between centers, a detailed protocol with standard methodology and criteria is proposed. This is also necessary for training. It has been shown that inter-rater variability increases post-training (from k=0.47 to k=0.80), while within-rater reproducibility in trained operators was k=0.75. Finally, the consensus document proposes a reporting standard of Duplex measurements, and future research to answer areas of uncertainty.
- 1 December 2011
- Vol. 30  (6) , 571-97
Screening for chronic cerebrospinal venous insufficiency (CCSVI) using ultrasound--recommendations for a protocol.
Chronic cerebrospinal venous insufficiency (CCSVI) is a syndrome characterized by stenoses or obstructions of the internal jugular and/or azygos veins with disturbed flow and formation of collateral venous channels. Studies using ultrasound in patients with multiple sclerosis (MS) have demonstrated a high prevalence of CCSVI (mean 70%; range 0-100%; N.=1496), whereas, in normal controls and patients without MS the prevalence was much lower (mean 10%; range 0-36%; N.=635). Ultrasound uses a combination of physiological measurements as well as anatomical imaging and has been used for the detection of CCSVI by different centers with variable results. A high prevalence ranging from 62% to 100% of obstructive lesions has been found by some teams in patients with MS compared with a lower prevalence of 0-25% in controls. However, absence of such lesions or a lower prevalence (16-52%) has been reported by others. This variability could be the result of differences in technique, training, experience or criteria used. The current lack of a methodology shared among experts is a confounding element in epidemiologic studies, and does not permit further Bayesan or other kind of analysis. In order to ensure a high reproducibility of Duplex scanning with comparable accuracy between centers, a detailed protocol with standard methodology and criteria is proposed. This is also necessary for training. It has been shown that inter-rater variability increases post-training (from k=0.47 to k=0.80), while within-rater reproducibility in trained operators was k=0.75. Finally, the consensus document proposes a reporting standard of Duplex measurements, and future research to answer areas of uncertainty.
- Open Access
- 7 March 2011
- Published by Springer Nature in BMC Medicine
- Vol. 9  (1) , 22
Hypoperfusion of brain parenchyma is associated with the severity of chronic cerebrospinal venous insufficiency in patients with multiple sclerosis: a cross-sectional preliminary report
Several studies have reported hypoperfusion of the brain parenchyma in multiple sclerosis (MS) patients. We hypothesized a possible relationship between abnormal perfusion in MS and hampered venous outflow at the extracranial level, a condition possibly associated with MS and known as chronic cerebrospinal venous insufficiency (CCSVI).
- 7 March 2011
- Published by Springer Nature in BMC Medicine
- Vol. 9  (1) , 22
Open AccessHypoperfusion of brain parenchyma is associated with the severity of chronic cerebrospinal venous insufficiency in patients with multiple sclerosis: a cross-sectional preliminary report
Several studies have reported hypoperfusion of the brain parenchyma in multiple sclerosis (MS) patients. We hypothesized a possible relationship between abnormal perfusion in MS and hampered venous outflow at the extracranial level, a condition possibly associated with MS and known as chronic cerebrospinal venous insufficiency (CCSVI).
- 1 April 2010
- Vol. 29  (2) , 121-6
The reproducibility of colour Doppler in chronic cerebrospinal venous insufficiency associated with multiple sclerosis.
Chronic cerebrospinal venous insufficiency (CCSVI) is a syndrome described in multiple sclerosis (MS) patients, characterized by stenosis of the main extracranial veins with hampered cerebral venous outflow. In the original description echo-colour Doppler demonstrated to be an ideal non invasive tool for screening CCSVI patients, but the reproducibility was not assessed. Aim of this study is to assess the variability coefficient between trained and in not trained echo-colour Doppler operators. Thirty-six (36) subjects, matched for age and gender, were subset in 3 groups (group A, 12 healthy controls, HC; group B, 12 multiple sclerosis patients, MS; group C, 12 patients with other neurological disease, OND) underwent echo-colour Doppler screening for CCSVI according to an original protocol previously described. The inter observer variability rate was assessed by comparing respectively trained vs not trained operators, and trained vs trained operators, by using the same echo-colour Doppler equipment. In addition, by scanning 15 subjects after one month from the first session, intra observer coefficient was also assessed in trained operator. The inter observer variability rate between trained and not trained echo-colour Doppler operators, were not completely satisfactory (K coefficient 0.47 95% CI 0.27-0.68). To the contrary the inter observer agreement between trained operators was much more reliable (K coefficient 0.80 95% CI 0.59-1.01). Finally, the intra observer variability rate in trained operators was 0.93, (95% CI 0.80-1.06) confirming a highly satisfactory agreement. Echo-colour Doppler is a powerful, non-invasive and reproducible tool for screening CCSVI-MS but it needs special training.
- 1 April 2010
- Vol. 29  (2) , 121-6
The reproducibility of colour Doppler in chronic cerebrospinal venous insufficiency associated with multiple sclerosis.
Chronic cerebrospinal venous insufficiency (CCSVI) is a syndrome described in multiple sclerosis (MS) patients, characterized by stenosis of the main extracranial veins with hampered cerebral venous outflow. In the original description echo-colour Doppler demonstrated to be an ideal non invasive tool for screening CCSVI patients, but the reproducibility was not assessed. Aim of this study is to assess the variability coefficient between trained and in not trained echo-colour Doppler operators. Thirty-six (36) subjects, matched for age and gender, were subset in 3 groups (group A, 12 healthy controls, HC; group B, 12 multiple sclerosis patients, MS; group C, 12 patients with other neurological disease, OND) underwent echo-colour Doppler screening for CCSVI according to an original protocol previously described. The inter observer variability rate was assessed by comparing respectively trained vs not trained operators, and trained vs trained operators, by using the same echo-colour Doppler equipment. In addition, by scanning 15 subjects after one month from the first session, intra observer coefficient was also assessed in trained operator. The inter observer variability rate between trained and not trained echo-colour Doppler operators, were not completely satisfactory (K coefficient 0.47 95% CI 0.27-0.68). To the contrary the inter observer agreement between trained operators was much more reliable (K coefficient 0.80 95% CI 0.59-1.01). Finally, the intra observer variability rate in trained operators was 0.93, (95% CI 0.80-1.06) confirming a highly satisfactory agreement. Echo-colour Doppler is a powerful, non-invasive and reproducible tool for screening CCSVI-MS but it needs special training.
- 1 April 2010
- Vol. 29  (2) , 127-39
Use of neck magnetic resonance venography, Doppler sonography and selective venography for diagnosis of chronic cerebrospinal venous insufficiency: a pilot study in multiple sclerosis patients and healthy controls.
Chronic cerebrospinal venous insufficiency (CCSVI) is a vascular condition characterized by anomalies of primary veins outside the skull that restrict normal outflow of blood from the brain. CCSVI was recently described as highly prevalent in patients with multiple sclerosis (MS), and can be non-invasively diagnosed by Doppler sonography (DS) and invasively by selective venography (SV). The aim of this paper was to investigate the value of neck magnetic resonance venography (MRV) for the diagnosis of CCSVI compared to DS and SV in patients with MS and in healthy controls (HC). Ten MS patients and 7 HC underwent DS, 2D-Time-Of-Flight venography (TOF) and 3D-Time Resolved Imaging of Contrast Kinetics angiography (TRICKS). MS patients also underwent SV. The internal jugular veins (IJVs) and the vertebral veins (VVs) were assessed by both MRV sequences, and the findings were validated against SV and DS. SV has been considered the diagnostic gold standard for MS patients. All MS patients and none of the HC presented CCSVI, according to the DS criteria. This was confirmed by SV. For CCSVI diagnosis, DS showed sensitivity, specificity, accuracy, PPV and NPV of 100%, whereas the figures were 40%, 85%, 58%, 80% and 50% for 3D-TRICKS, and 30%, 85%, 52%, 75% and 46% for 2D-TOF in the IJVs. In MS patients, compared to SV, DS showed sensitivity, specificity, accuracy, PPV and NPV of 100%, 75%, 95%, 94% and 100%, whereas the figures were 31%, 100%, 45%, 100% and 26% for 3D-TRICKS and 25%, 100%, 40%, 100% and 25% for 2D-TOF in the IJVs. The use of MRV for diagnosis of CCSVI in MS patients has limited value, and the findings should be interpreted with caution and confirmed by other imaging techniques such as DS and SV.
- 1 April 2010
- Vol. 29  (2) , 127-39
Use of neck magnetic resonance venography, Doppler sonography and selective venography for diagnosis of chronic cerebrospinal venous insufficiency: a pilot study in multiple sclerosis patients and healthy controls.
Chronic cerebrospinal venous insufficiency (CCSVI) is a vascular condition characterized by anomalies of primary veins outside the skull that restrict normal outflow of blood from the brain. CCSVI was recently described as highly prevalent in patients with multiple sclerosis (MS), and can be non-invasively diagnosed by Doppler sonography (DS) and invasively by selective venography (SV). The aim of this paper was to investigate the value of neck magnetic resonance venography (MRV) for the diagnosis of CCSVI compared to DS and SV in patients with MS and in healthy controls (HC). Ten MS patients and 7 HC underwent DS, 2D-Time-Of-Flight venography (TOF) and 3D-Time Resolved Imaging of Contrast Kinetics angiography (TRICKS). MS patients also underwent SV. The internal jugular veins (IJVs) and the vertebral veins (VVs) were assessed by both MRV sequences, and the findings were validated against SV and DS. SV has been considered the diagnostic gold standard for MS patients. All MS patients and none of the HC presented CCSVI, according to the DS criteria. This was confirmed by SV. For CCSVI diagnosis, DS showed sensitivity, specificity, accuracy, PPV and NPV of 100%, whereas the figures were 40%, 85%, 58%, 80% and 50% for 3D-TRICKS, and 30%, 85%, 52%, 75% and 46% for 2D-TOF in the IJVs. In MS patients, compared to SV, DS showed sensitivity, specificity, accuracy, PPV and NPV of 100%, 75%, 95%, 94% and 100%, whereas the figures were 31%, 100%, 45%, 100% and 26% for 3D-TRICKS and 25%, 100%, 40%, 100% and 25% for 2D-TOF in the IJVs. The use of MRV for diagnosis of CCSVI in MS patients has limited value, and the findings should be interpreted with caution and confirmed by other imaging techniques such as DS and SV.
- 1 April 2010
- Vol. 29  (2) , 140-8
CSF dynamics and brain volume in multiple sclerosis are associated with extracranial venous flow anomalies: a pilot study.
We previously reported unexpectedly robust associations between vascular haemodynamic (VH) anomalies in the principal extracranial cerebral veins, causing chronic cerebrospinal venous insufficiency (CCSVI), and multiple sclerosis (MS). Aim of this study was to investigate the relationship between the VH changes and MRI measures of MS disease severity in a cross sectional survey. The number of anomalous VH criteria were measured using an echo-color Doppler, whereas CSF flow, atrophy and lesion measures were obtained from quantitative magnetic resonance imaging (MRI) analysis in sixteen consecutive relapsing-remitting MS patients, (mean age: 36.1+/-SD 7.3 years, disease duration: 7.5+/-1.9 years and median EDSS: 2.5) and in 8 healthy controls (HC) with similar age and sex distributions. All 16 MS patients investigated and none of the HCs met the VH criteria for CCSVI (P<0.0001). MS patients showed significantly lower net CSF flow compared to the HC (P=0.038) that was associated with number of anomalous VH criteria present (r=0.79, P<0.001). Moreover, increases in the number of anomalous VH criteria present were negatively associated with lower whole brain volume (Spearman R=-0.5, P=0.05). VH changes occur more frequently in MS patients than controls. Altered VH is associated with abnormal CSF flow dynamics and decreased brain volume.
- 1 April 2010
- Vol. 29  (2) , 140-8
CSF dynamics and brain volume in multiple sclerosis are associated with extracranial venous flow anomalies: a pilot study.
We previously reported unexpectedly robust associations between vascular haemodynamic (VH) anomalies in the principal extracranial cerebral veins, causing chronic cerebrospinal venous insufficiency (CCSVI), and multiple sclerosis (MS). Aim of this study was to investigate the relationship between the VH changes and MRI measures of MS disease severity in a cross sectional survey. The number of anomalous VH criteria were measured using an echo-color Doppler, whereas CSF flow, atrophy and lesion measures were obtained from quantitative magnetic resonance imaging (MRI) analysis in sixteen consecutive relapsing-remitting MS patients, (mean age: 36.1+/-SD 7.3 years, disease duration: 7.5+/-1.9 years and median EDSS: 2.5) and in 8 healthy controls (HC) with similar age and sex distributions. All 16 MS patients investigated and none of the HCs met the VH criteria for CCSVI (P<0.0001). MS patients showed significantly lower net CSF flow compared to the HC (P=0.038) that was associated with number of anomalous VH criteria present (r=0.79, P<0.001). Moreover, increases in the number of anomalous VH criteria present were negatively associated with lower whole brain volume (Spearman R=-0.5, P=0.05). VH changes occur more frequently in MS patients than controls. Altered VH is associated with abnormal CSF flow dynamics and decreased brain volume.
- 1 April 2010
- Vol. 29  (2) , 158-75
Chronic cerebrospinal venous insufficiency and iron deposition on susceptibility-weighted imaging in patients with multiple sclerosis: a pilot case-control study.
Chronic cerebrospinal venous insufficiency (CCSVI) is a vascular phenomenon recently described in multiple sclerosis (MS) that is characterized by stenoses affecting the main extracranial venous outflow pathways and by a high rate of cerebral venous reflux that may lead to increased iron deposition in the brain. Aim of this study was to investigate the relationship between CCSVI and iron deposition in the brain of MS patients by correlating venous hemodynamic (VH) parameters and iron concentration in deep-gray matter structures and lesions, as measured by susceptibility-weighted imaging (SWI), and to preliminarily define the relationship between iron measures and clinical and other magnetic resonance imaging (MRI) outcomes. Sixteen (16) consecutive relapsing-remitting MS patients and 8 age- and sex-matched healthy controls (HC) were scanned on a GE 3T scanner, using SWI. All 16 MS patients fulfilled the diagnosis of CCSVI (median VH=4), compared to none of the HC. In MS patients, the higher iron concentration in the pulvinar nucleus of the thalamus, thalamus, globus pallidus, and hippocampus was related to a higher number of VH criteria (P<0.05). There was also a significant association between a higher number of VH criteria and higher iron concentration of overlapping T2 (r=-0.64, P=0.007) and T1 (r=-0.56, P=0.023) phase lesions. Iron concentration measures were related to longer disease duration and increased disability as measured by EDSS and MSFC, and to increased MRI lesion burden and decreased brain volume. The findings from this pilot study suggest that CCSVI may be an important mechanism related to iron deposition in the brain parenchyma of MS patients. In turn, iron deposition, as measured by SWI, is a modest-to-strong predictor of disability progression, lesion volume accumulation and atrophy development in patients with MS.
- 1 April 2010
- Vol. 29  (2) , 158-75
Chronic cerebrospinal venous insufficiency and iron deposition on susceptibility-weighted imaging in patients with multiple sclerosis: a pilot case-control study.
Chronic cerebrospinal venous insufficiency (CCSVI) is a vascular phenomenon recently described in multiple sclerosis (MS) that is characterized by stenoses affecting the main extracranial venous outflow pathways and by a high rate of cerebral venous reflux that may lead to increased iron deposition in the brain. Aim of this study was to investigate the relationship between CCSVI and iron deposition in the brain of MS patients by correlating venous hemodynamic (VH) parameters and iron concentration in deep-gray matter structures and lesions, as measured by susceptibility-weighted imaging (SWI), and to preliminarily define the relationship between iron measures and clinical and other magnetic resonance imaging (MRI) outcomes. Sixteen (16) consecutive relapsing-remitting MS patients and 8 age- and sex-matched healthy controls (HC) were scanned on a GE 3T scanner, using SWI. All 16 MS patients fulfilled the diagnosis of CCSVI (median VH=4), compared to none of the HC. In MS patients, the higher iron concentration in the pulvinar nucleus of the thalamus, thalamus, globus pallidus, and hippocampus was related to a higher number of VH criteria (P<0.05). There was also a significant association between a higher number of VH criteria and higher iron concentration of overlapping T2 (r=-0.64, P=0.007) and T1 (r=-0.56, P=0.023) phase lesions. Iron concentration measures were related to longer disease duration and increased disability as measured by EDSS and MSFC, and to increased MRI lesion burden and decreased brain volume. The findings from this pilot study suggest that CCSVI may be an important mechanism related to iron deposition in the brain parenchyma of MS patients. In turn, iron deposition, as measured by SWI, is a modest-to-strong predictor of disability progression, lesion volume accumulation and atrophy development in patients with MS.