JSJeff A. Sherman

Jeff A. Sherman

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jeff A. Sherman has a total of 43 co-authors. Here are the top co-authors by number of shared publications:

  • C. W. Oates

    National Institute of Standards and Technology, 325 Broadway, Boulder, Colorado 80305, USA

    4 shared publications
  • A. D. Ludlow

    National Institute of Standards and Technology, 325 Broadway, Boulder, Colorado 80305, USA

    3 shared publications
  • N. D. Lemke

    National Institute of Standards and Technology, 325 Broadway, Boulder, Colorado 80305, USA

    3 shared publications
  • N. Hinkley

    National Institute of Standards and Technology, 325 Broadway, Boulder, Colorado 80305, USA

    3 shared publications
  • A. M. Steane

    Department of Physics Clarendon Laboratory University of Oxford Parks Road OX1 3PU Oxford UK

    2 shared publications
  • D. M. Lucas

    Clarendon Laboratory, Department of Physics, University of Oxford, Parks Road, Oxford OX1 3PU, United Kingdom

    2 shared publications

Latest Publications

  • Measurement of the 27 Al + and 87 Sr absolute optical frequencies

    by Holly Leopardi, Kyle Beloy, Tobias Bothwell, Samuel M Brewer, Sarah L Bromley, Jwo-Sy Chen, Scott A Diddams, Robert J Fasano, Youssef S Hassan, David B Hume, et al.

    We perform absolute measurement of the 27 Al + single-ion and 87 Sr neutral lattice clock frequencies at the National Institute of Standards and Technology and JILA at the University of Colorado against a global ensemble of primary frequency standards. Over an eight month period multiple measurements yielded the mean optical atomic transition frequencies ν Al + = 1 121 015 393 207 859.50 ( 0.36 ) Hz and ν Sr = 429 228 004 229 873.19(0.15) Hz, where the stated uncertainties are dominated by statistical noise and gaps in the observation interval (‘dead-time’ uncertainty).


  • Open Access

    Oscillator metrology with software defined radio

    by Jeff A. Sherman, Robert Jördens

    Analog electrical elements such as mixers, filters, transfer oscillators, isolating buffers, dividers, and even transmission lines contribute technical noise and unwanted environmental coupling in time and frequency measurements. Software defined radio (SDR) techniques replace many of these analog components with digital signal processing (DSP) on rapidly sampled signals. We demonstrate that, generically, commercially available multi-channel SDRs are capable of time and frequency metrology, outperforming purpose-built devices by as much as an order-of-magnitude. For example, for signals at 10 MHz and 6 GHz, we observe SDR time deviation noise floors of about 20 fs and 1 fs, respectively, in under 10 ms of averaging. Examining the other complex signal component, we find a relative amplitude measurement instability of 3e-7 at 5 MHz. We discuss the scalability of a SDR-based system for simultaneous measurement of many clocks. SDR's frequency agility allows for comparison of oscillators at widely different frequencies. We demonstrate a novel and extreme example with optical clock frequencies differing by many terahertz: using a femtosecond-laser frequency comb and SDR, we show femtosecond-level time comparisons of ultra-stable lasers with zero measurement dead-time.

  • Usage Analysis of the NIST Internet Time Service

    by Jeff A. Sherman, Judah Levine

    The Internet Time Service (ITS) at the National Institute of Standards and Technology (NIST) currently receives over 16 billion time requests per day. ITS servers derive their system time from the NIST atomic-referenced time scale and distribute it freely to the public. Here we explore ITS usage patterns discovered by analysis of inbound network traffic. For example, over a period of four weeks, just two of the ≈ 20 ITS servers received requests from 316 million unique Internet Protocol (IPv4) addresses, which is at least 8.5 % of the entire Internet. We offer recommendations for networked device/software manufacturers, and providers and consumers of network time services.


  • Open Access

    Experimental recovery of a qubit from partial collapse

    by J. A. Sherman, M. J. Curtis, D. J. Szwer, D. T. C. Allcock, G. Imreh, D. M. Lucas, A. M. Steane

    We describe and implement a method to restore the state of a single qubit, in principle perfectly, after it has partially collapsed. The method resembles the classical Hahn spin-echo, but works on a wider class of relaxation processes, in which the quantum state partially leaves the computational Hilbert space. It is not guaranteed to work every time, but successful outcomes are heralded. We demonstrate using a single trapped ion better performance from this recovery method than can be obtained employing projection and post-selection alone. The demonstration features a novel qubit implementation that permits both partial collapse and coherent manipulations with high fidelity.

  • Experimental Recovery of a Qubit from Partial Collapse

    by J. A. Sherman, M. J. Curtis, D. J. Szwer, D. T. C. Allcock, G. Imreh, D. M. Lucas, A. M. Steane

    We describe and implement a method to restore the state of a single qubit, in principle perfectly, after it has partially collapsed. The method resembles the classical Hahn spin echo but works on a wider class of relaxation processes, in which the quantum state partially leaves the computational Hilbert space. It is not guaranteed to work every time, but successful outcomes are heralded. We demonstrate, using a single trapped ion, a better performance from this recovery method than can be obtained employing projection and postselection alone. The demonstration features a novel qubit implementation that permits both partial collapse and coherent manipulations with high fidelity.


  • Determination of the5d6s3D1state lifetime and blackbody-radiation clock shift in Yb

    by K. Beloy, J. A. Sherman, N. D. Lemke, N. Hinkley, C. W. Oates, A. D. Ludlow

    The Stark shift of the ytterbium (Yb) optical clock transition due to room-temperature blackbody radiation is dominated by a static Stark effect, which was recently measured to high accuracy [J. A. Sherman et al., Phys. Rev. Lett. 108, 153002 (2012)]. However, room-temperature realization of the clock at 10−18 uncertainty requires a dynamic contribution to this static approximation. This dynamic term largely depends on a single electric dipole matrix element for which theoretically and experimentally derived values disagree significantly. We determine this important matrix element by two independent methods, which yield consistent values. Along with precise radiative lifetimes of 6s6p3P1 and 5d6s3D1, we report the clock shift due to an ideal 300 K blackbody environment to 0.05% precision.


  • Open Access

    Determination of the 5d6s 3D1 state lifetime and blackbody radiation clock shift in Yb

    by K. Beloy, J. A. Sherman, N. D. Lemke, N. Hinkley, C. W. Oates, A. D. Ludlow

    The Stark shift of the ytterbium optical clock transition due to room temperature blackbody radiation is dominated by a static Stark effect, which was recently measured to high accuracy [J. A. Sherman et al., Phys. Rev. Lett. 108, 153002 (2012)]. However, room temperature operation of the clock at 10^{-18} inaccuracy requires a dynamic correction to this static approximation. This dynamic correction largely depends on a single electric dipole matrix element for which theoretically and experimentally derived values disagree significantly. We determine this important matrix element by two independent methods, which yield consistent values. Along with precise radiative lifetimes of 6s6p 3P1 and 5d6s 3D1, we report the clock's blackbody radiation shift to 0.05% precision.

  • Open Access

    High-Accuracy Measurement of Atomic Polarizability in an Optical Lattice Clock

    by J. A. Sherman, N. D. Lemke, N. Hinkley, M. Pizzocaro, R. W. Fox, A. D. Ludlow, C. W. Oates

    Presently, the Stark effect contributes the largest source of uncertainty in a ytterbium optical atomic clock through blackbody radiation. By employing an ultracold, trapped atomic ensemble and high stability optical clock, we characterize the quadratic Stark effect with unprecedented precision. We report the ytterbium optical clock’s sensitivity to electric fields (such as blackbody radiation) as the differential static polarizability of the ground and excited clock levels αclock=36.2612(7)  kHz (kV/cm)−2. The clock’s uncertainty due to room temperature blackbody radiation is reduced by an order of magnitude to 3×10−17.


  • Open Access

    Stability limits of an optical frequency standard based on free Ca atoms

    by J. A. Sherman, C. W. Oates

    We have quantified a short term instability budget for an optical frequency standard based on cold, freely expanding calcium atoms. Such systems are the subject of renewed interest due to their high frequency stability and relative technical simplicity compared to trapped atom optical clocks. By filtering the clock laser light at 657 nm through a high finesse cavity, we observe a slight reduction in the optical Dick effect caused by aliased local oscillator noise. The ultimately limiting technical noise is measured using a technique that does not rely on a second clock or fs-comb.