Natalie L. Davis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Natalie L. Davis has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
A. Pickering
University of Maryland School of Medicine, Baltimore, MD, USA
1 shared publicationAnn Liu
Division of Respiratory Diseases Boston Children's Hospital Boston MA
1 shared publicationBrian N. Corwell
University of Maryland School of Medicine, Baltimore, Maryland
1 shared publicationElena Donald
University of Maryland School of Medicine, Baltimore, Maryland
1 shared publicationL Rhein
Division of Respiratory Diseases, Boston Children’s Hospital, Boston, MA, USA
1 shared publicationLawrence Rhein
Division of Respiratory Diseases Boston Children's Hospital Boston MA
1 shared publication
Latest Publications
- 23 May 2018
- Published by SAGE Publications in Journal of Neonatal-Perinatal Medicine
- Vol. 11 (3) , 249-255
Post-discharge outcomes of failed car seat tolerance screens: A case-control and follow-up study
BACKGROUND: Despite widespread implementation, limited data exists relating morbidity or adverse outcomes to Car Seat Tolerance Screen (CSTS) result in preterm and low birth weight (LBW) neonates. The objective of this study was to determine longer term post-discharge outcomes of infants who failed a CSTS. METHODS: We performed a case control study evaluating outcomes of infants born over one year who failed vs. passed an initial CSTS, utilizing both retrospective medical record review and parental survey data 2–3 years after discharge. Subjects were matched one case of failed CSTS to two controls who passed CSTS based on sex, gestational age, and BW. We performed bivariate analysis of clinical and demographic risk factors comparing those who passed vs. failed CSTS. RESULTS: We identified 19 subjects who failed and matched to 37 controls. Cases were significantly more likely to be diagnosed with obstructive sleep apnea ( p = 0.027), asthma ( p = 0.016), and be treated with albuterol ( p = 0.008). We did not find differences in frequency of urgent care visits or hospital admissions between the groups. Although more of the cases were noted to have developmental delays, the difference was not statistically significant. CONCLUSION: This is the first study to evaluate longer term post-discharge outcomes of subjects having undergone CSTS. Subjects who failed CSTS had significantly increased incidence of respiratory diagnoses such as OSA and asthma than matched controls by 2–3 years after discharge. Larger studies are necessary to further evaluate these findings, but this does provide data that CSTS may be useful in identifying at risk neonates.
- 23 May 2018
- Published by SAGE Publications in Journal of Neonatal-Perinatal Medicine
- Vol. 11 (3) , 249-255
Post-discharge outcomes of failed car seat tolerance screens: A case-control and follow-up study
BACKGROUND: Despite widespread implementation, limited data exists relating morbidity or adverse outcomes to Car Seat Tolerance Screen (CSTS) result in preterm and low birth weight (LBW) neonates. The objective of this study was to determine longer term post-discharge outcomes of infants who failed a CSTS. METHODS: We performed a case control study evaluating outcomes of infants born over one year who failed vs. passed an initial CSTS, utilizing both retrospective medical record review and parental survey data 2–3 years after discharge. Subjects were matched one case of failed CSTS to two controls who passed CSTS based on sex, gestational age, and BW. We performed bivariate analysis of clinical and demographic risk factors comparing those who passed vs. failed CSTS. RESULTS: We identified 19 subjects who failed and matched to 37 controls. Cases were significantly more likely to be diagnosed with obstructive sleep apnea ( p = 0.027), asthma ( p = 0.016), and be treated with albuterol ( p = 0.008). We did not find differences in frequency of urgent care visits or hospital admissions between the groups. Although more of the cases were noted to have developmental delays, the difference was not statistically significant. CONCLUSION: This is the first study to evaluate longer term post-discharge outcomes of subjects having undergone CSTS. Subjects who failed CSTS had significantly increased incidence of respiratory diagnoses such as OSA and asthma than matched controls by 2–3 years after discharge. Larger studies are necessary to further evaluate these findings, but this does provide data that CSTS may be useful in identifying at risk neonates.
- 22 May 2017
- Published by Georg Thieme Verlag KG in American Journal of Perinatology
- Vol. 34 (13) , 1318-1325
Assessment of Anthropometric Measurements as Predictors of Car Seat Screening Failure
Objective The objective of this study was to determine whether anthropometric measurements such as head circumference (HC), body mass index (BMI), and body surface area (BSA) can predict car seat tolerance screen (CSTS) failure. We hypothesized that subjects with larger HC and lower BMI/BSA would have increased risk of failure. Study Design We performed retrospective medical record review of infants born in 2013 who qualified for CSTS due to being born preterm (< 37 weeks) or low birth weight (LBW). We performed bivariate analyses of clinical and demographic risk factors including anthropometrics to identify predictors of CSTS failure. Results In this study, 19 of 366 subjects failed their CSTS (5.3%). There were no significant differences in HC, length, BSA, BMI, or ratio of HC to length, BMI, or BSA between those who passed versus failed. On subgroup analysis of preterm infants, the significant predictor of failure was multiple gestation (p = 0.024). In the term LBW cohort, requiring nasal canula (NC) (p = 0.03) and having limited or no prenatal care (PNC) (p = 0.0006) were both significant predictors of failure. Conclusion Neither absolute measurements nor the ratios of HC to body measurements predicted CSTS outcome. Multiple gestation was a significant predictor of failure in preterm infants, while NC requirement and poor PNC were predictors in LBW term infants.
- 22 May 2017
- Published by Georg Thieme Verlag KG in American Journal of Perinatology
- Vol. 34 (13) , 1318-1325
Assessment of Anthropometric Measurements as Predictors of Car Seat Screening Failure
Objective The objective of this study was to determine whether anthropometric measurements such as head circumference (HC), body mass index (BMI), and body surface area (BSA) can predict car seat tolerance screen (CSTS) failure. We hypothesized that subjects with larger HC and lower BMI/BSA would have increased risk of failure. Study Design We performed retrospective medical record review of infants born in 2013 who qualified for CSTS due to being born preterm (< 37 weeks) or low birth weight (LBW). We performed bivariate analyses of clinical and demographic risk factors including anthropometrics to identify predictors of CSTS failure. Results In this study, 19 of 366 subjects failed their CSTS (5.3%). There were no significant differences in HC, length, BSA, BMI, or ratio of HC to length, BMI, or BSA between those who passed versus failed. On subgroup analysis of preterm infants, the significant predictor of failure was multiple gestation (p = 0.024). In the term LBW cohort, requiring nasal canula (NC) (p = 0.03) and having limited or no prenatal care (PNC) (p = 0.0006) were both significant predictors of failure. Conclusion Neither absolute measurements nor the ratios of HC to body measurements predicted CSTS outcome. Multiple gestation was a significant predictor of failure in preterm infants, while NC requirement and poor PNC were predictors in LBW term infants.
- 19 May 2016
- Published by SAGE Publications in Journal of Neonatal-Perinatal Medicine
- Vol. 9 (2) , 171-178
Routine fecal occult blood testing does not predict necrotizing enterocolitis in very low birth weight neonates
OBJECTIVE: To determine sensitivity, specificity, predictive value of routine fecal occult blood (FOB) testing on the identification of Bell’s Stage II or III necrotizing enterocolitis (NEC) in very low birth weight (VLBW) infants. METHODS: Retrospective medical record review of VLBW infants from 2012– 2013 evaluating FOB results and clinical and demographic risk factors. We determined predictive values of positive FOB testing within 48 hours of definite NEC diagnosis. We performed logistic regression analyses for predictors of NEC and for predictors of having positive FOB during NICU admission. RESULTS: The incidence of NEC in our cohort of 203 infants was 3.9% ( n = 8). None had positive FOB results within 48 hours of diagnosis, and only 12.5% had any positive FOB within 7 days. Sensitivity of positive FOB for predicting definite NEC = 0%, specificity = 34.4%, and positive predictive value = 0%. A majority of VLBWs (67.0%) had > one positive FOB result during their NICU course. On logistic regression, intrauterine growth restricted (IUGR) infants had significantly higher odds of both developing NEC and of having positive FOB. Positive FOB was not a significant predictor of NEC. Those with lower birth gestational ages had higher odds of positive FOB. CONCLUSIONS: Positive FOB testing occurred in a majority of VLBW infants, with higher odds in the more preterm and IUGR. However, the sensitivity, specificity, and predictive value of routine FOB testing for identifying NEC were all very poor. Our data demonstrates that this test offers no advantages in the early diagnosis of NEC.
- 19 May 2016
- Published by SAGE Publications in Journal of Neonatal-Perinatal Medicine
- Vol. 9 (2) , 171-178
Routine fecal occult blood testing does not predict necrotizing enterocolitis in very low birth weight neonates
OBJECTIVE: To determine sensitivity, specificity, predictive value of routine fecal occult blood (FOB) testing on the identification of Bell’s Stage II or III necrotizing enterocolitis (NEC) in very low birth weight (VLBW) infants. METHODS: Retrospective medical record review of VLBW infants from 2012– 2013 evaluating FOB results and clinical and demographic risk factors. We determined predictive values of positive FOB testing within 48 hours of definite NEC diagnosis. We performed logistic regression analyses for predictors of NEC and for predictors of having positive FOB during NICU admission. RESULTS: The incidence of NEC in our cohort of 203 infants was 3.9% ( n = 8). None had positive FOB results within 48 hours of diagnosis, and only 12.5% had any positive FOB within 7 days. Sensitivity of positive FOB for predicting definite NEC = 0%, specificity = 34.4%, and positive predictive value = 0%. A majority of VLBWs (67.0%) had > one positive FOB result during their NICU course. On logistic regression, intrauterine growth restricted (IUGR) infants had significantly higher odds of both developing NEC and of having positive FOB. Positive FOB was not a significant predictor of NEC. Those with lower birth gestational ages had higher odds of positive FOB. CONCLUSIONS: Positive FOB testing occurred in a majority of VLBW infants, with higher odds in the more preterm and IUGR. However, the sensitivity, specificity, and predictive value of routine FOB testing for identifying NEC were all very poor. Our data demonstrates that this test offers no advantages in the early diagnosis of NEC.
- 1 July 2015
- Published by American Academy of Pediatrics (AAP) in Pediatrics
- Vol. 136 (1) , 89-96
Car Seat Screening for Low Birth Weight Term Neonates
BACKGROUND AND OBJECTIVE: Car seat tolerance screening (CSTS) is a common predischarge assessment of neonates. Almost half of nurseries and NICUs have low birth weight (LBW, METHODS: This was a retrospective medical record review of 220 full-term LBW infants qualifying for CSTS over a 4-year period between January 2010 to December 2013. We described CSTS results and performed bivariate analyses to evaluate for predictors of failure. RESULTS: Overall failure incidence was 4.8%. There were no differences between those who passed and those who failed based on birth weight, birth GA, race, gender, Apgar scores, respiratory support requirements, magnesium exposure, corrected GA, or weight at the time of CSTS. Maternal urine toxicology positive for opiates was found to be a significant predictor of CSTS failure. Of the 9 subjects who failed, 2 had a specific diagnosis identified (Prader–Willi syndrome and long QT syndrome) after a failed CSTS prompted closer examination and workup before discharge. CONCLUSIONS: We found a similar incidence of failure for full-term LBW infants as has been previously reported for preterm infants. The infants who failed were more likely to have mothers who tested positive for opiates before delivery. Epidemiologic data are provided to help guide future CSTS policies and protocol development for this group.
- 1 July 2015
- Published by American Academy of Pediatrics (AAP) in Pediatrics
- Vol. 136 (1) , 89-96
Car Seat Screening for Low Birth Weight Term Neonates
BACKGROUND AND OBJECTIVE: Car seat tolerance screening (CSTS) is a common predischarge assessment of neonates. Almost half of nurseries and NICUs have low birth weight (LBW, METHODS: This was a retrospective medical record review of 220 full-term LBW infants qualifying for CSTS over a 4-year period between January 2010 to December 2013. We described CSTS results and performed bivariate analyses to evaluate for predictors of failure. RESULTS: Overall failure incidence was 4.8%. There were no differences between those who passed and those who failed based on birth weight, birth GA, race, gender, Apgar scores, respiratory support requirements, magnesium exposure, corrected GA, or weight at the time of CSTS. Maternal urine toxicology positive for opiates was found to be a significant predictor of CSTS failure. Of the 9 subjects who failed, 2 had a specific diagnosis identified (Prader–Willi syndrome and long QT syndrome) after a failed CSTS prompted closer examination and workup before discharge. CONCLUSIONS: We found a similar incidence of failure for full-term LBW infants as has been previously reported for preterm infants. The infants who failed were more likely to have mothers who tested positive for opiates before delivery. Epidemiologic data are provided to help guide future CSTS policies and protocol development for this group.
- 12 February 2015
- Published by Springer Nature in Journal of Perinatology
- Vol. 35 (4) , 235-240
Screening for cardiopulmonary events in neonates: a review of the infant car seat challenge
The infant car seat challenge (ICSC), or period of observation in a car safety seat before discharge to monitor for episodes of apnea, bradycardia and desaturation, is one of the most common tests performed on preterm neonates in the United States. However, the utility of the ICSC to identify infants at risk for adverse cardiopulmonary events in the car seat remains unclear. Minimal evidence exists to guide clinicians in performance of this test including appropriate inclusion criteria and failure criteria. In this article, the origins of the ICSC are discussed as well as potential etiologies of desaturations and bradycardia in the car seat position. Current literature on implementation, inclusion and failure criteria, incidence of failure and data on the meaning of a ‘passed’ vs ‘failed’ ICSC are discussed. Emphasis is made on minimizing time in car seats and seated devices given concern over the risk of desaturations.
- 12 February 2015
- Published by Springer Nature in Journal of Perinatology
- Vol. 35 (4) , 235-240
Screening for cardiopulmonary events in neonates: a review of the infant car seat challenge
The infant car seat challenge (ICSC), or period of observation in a car safety seat before discharge to monitor for episodes of apnea, bradycardia and desaturation, is one of the most common tests performed on preterm neonates in the United States. However, the utility of the ICSC to identify infants at risk for adverse cardiopulmonary events in the car seat remains unclear. Minimal evidence exists to guide clinicians in performance of this test including appropriate inclusion criteria and failure criteria. In this article, the origins of the ICSC are discussed as well as potential etiologies of desaturations and bradycardia in the car seat position. Current literature on implementation, inclusion and failure criteria, incidence of failure and data on the meaning of a ‘passed’ vs ‘failed’ ICSC are discussed. Emphasis is made on minimizing time in car seats and seated devices given concern over the risk of desaturations.
- 1 December 2013
- Published by Wiley in Journal of Pediatric Gastroenterology and Nutrition
- Vol. 57 (6) , 735-740
Feeding Immaturity in Preterm Neonates
Objective: Oropharyngeal aspiration (OPA) is a common cause of morbidity in premature neonates. We sought to identify significant risk factors and determine the timing of feeding maturation in preterm infants with OPA.Methods: We performed a retrospective medical record review of 148 former preterm neonates referred for modified barium swallow study (MBSS) during a 3‐year period. We looked at the MBSS results and potential clinical and demographic risk factors and performed bivariate and multivariable logistic regression analyses to evaluate predictors of failure. We evaluated the timing of resolution of OPA based on MBSS results.Results: Of the 148 infants comprising our study cohort, 47 (32%) passed their initial MBSS and 101 (68%) were found to aspirate thin liquids. Infants who aspirate had younger corrected gestational age (CGA) and postnatal age at the time of testing. Increasing CGA led to lower odds of failing. Infants passed a MBSS at a median CGA of 53 weeks and those who failed an initial MBSS eventually passed after a median of ∼3.4 months from the first study. Infants with bronchopulmonary dysplasia had lower odds of failing their MBSS (odds ratio 0.16), but those taking inhaled corticosteroids and diuretics had higher odds of failing, and infants who were multiples also had higher odds of failing.Conclusions: We determined the median CGA for passing MBSS and identified risk factors for OPA in this population. This information can help guide providers when counseling families on timing of feeding maturity and anticipation of appropriate timing for follow‐up MBSS testing.
- 1 December 2013
- Published by Wiley in Journal of Pediatric Gastroenterology and Nutrition
- Vol. 57 (6) , 735-740
Feeding Immaturity in Preterm Neonates
Objective: Oropharyngeal aspiration (OPA) is a common cause of morbidity in premature neonates. We sought to identify significant risk factors and determine the timing of feeding maturation in preterm infants with OPA.Methods: We performed a retrospective medical record review of 148 former preterm neonates referred for modified barium swallow study (MBSS) during a 3‐year period. We looked at the MBSS results and potential clinical and demographic risk factors and performed bivariate and multivariable logistic regression analyses to evaluate predictors of failure. We evaluated the timing of resolution of OPA based on MBSS results.Results: Of the 148 infants comprising our study cohort, 47 (32%) passed their initial MBSS and 101 (68%) were found to aspirate thin liquids. Infants who aspirate had younger corrected gestational age (CGA) and postnatal age at the time of testing. Increasing CGA led to lower odds of failing. Infants passed a MBSS at a median CGA of 53 weeks and those who failed an initial MBSS eventually passed after a median of ∼3.4 months from the first study. Infants with bronchopulmonary dysplasia had lower odds of failing their MBSS (odds ratio 0.16), but those taking inhaled corticosteroids and diuretics had higher odds of failing, and infants who were multiples also had higher odds of failing.Conclusions: We determined the median CGA for passing MBSS and identified risk factors for OPA in this population. This information can help guide providers when counseling families on timing of feeding maturity and anticipation of appropriate timing for follow‐up MBSS testing.
- 17 October 2013
- Published by Springer Nature in Journal of Perinatology
- Vol. 34 (1) , 54-58
Test−retest reliability of the infant car-seat challenge
Objective: To evaluate how a single infant car-seat challenge (ICSC) predicts subsequent respiratory physiology in premature infants. Study Design: Prospective observational study of infants born at <37 weeks gestational age. Subjects underwent three ICSCs and we evaluated clinical characteristics, pass rate, and predictive value of a single ICSC pass. Result: Completed three ICSCs on 60 subjects. Seven failed initial ICSC (11.7%). Those who failed had lower birth weights. Of the 53 that initially passed, 47 passed two subsequent tests (89%). Those who passed an initial test and failed a subsequent test had lower weights at each ICSC. Conclusion: Our results indicate that passing an ICSC is highly predictive of passing subsequent ICSCs. Lower weights at birth and at the time of ICSC were associated with increased risk of failure. We recommend including low birth weight as an inclusion criterion for ICSCs.
- 17 October 2013
- Published by Springer Nature in Journal of Perinatology
- Vol. 34 (1) , 54-58
Test−retest reliability of the infant car-seat challenge
Objective: To evaluate how a single infant car-seat challenge (ICSC) predicts subsequent respiratory physiology in premature infants. Study Design: Prospective observational study of infants born at <37 weeks gestational age. Subjects underwent three ICSCs and we evaluated clinical characteristics, pass rate, and predictive value of a single ICSC pass. Result: Completed three ICSCs on 60 subjects. Seven failed initial ICSC (11.7%). Those who failed had lower birth weights. Of the 53 that initially passed, 47 passed two subsequent tests (89%). Those who passed an initial test and failed a subsequent test had lower weights at each ICSC. Conclusion: Our results indicate that passing an ICSC is highly predictive of passing subsequent ICSCs. Lower weights at birth and at the time of ICSC were associated with increased risk of failure. We recommend including low birth weight as an inclusion criterion for ICSCs.