Jie Huang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jie Huang has a total of 70 co-authors. Here are the top co-authors by number of shared publications:
Qian Zhao
Department of Development Planning and Disciplinary Construction, Southwest University, Chongqing, China
13 shared publicationsYongfeng Wu
6 shared publicationsGuoqing Xu
College of Engineering and Technology Southwest University 400715 Chongqing China
5 shared publicationsJing Li
College of Engineering and Technology Southwest University 400715 Chongqing China
5 shared publicationsWenwen Gu
College of Engineering and Technology, Southwest University, Chongqing, China
5 shared publicationsYuhan Xiang
College of Engineering and Technology, Southwest University, Chongqing, China
5 shared publications
Latest Publications
- Open Access
A Multiport Network-Based Integrated Sensing System Using Rectangular Cavity Resonators for Volatile Organic Compounds
This work presents a novel microwave sensor system for volatile gas detection, integrating sensing elements based on rectangular cavity resonators (RCR) and multiport demodulation circuitry. Initially, a pump-through gas sensing element utilizing an RCR was developed, and its core sensing functionality was experimentally validated. Subsequently, a rat-race coupler was employed to seamlessly integrate two such rectangular cavity resonator elements—serving as reference and sensing branches—within the multiport demodulation network. This configuration enabled an in-depth investigation of the network’s operating principle, elucidating the critical relationship between the reference and sensing arms. The demodulation network translates the critical output phase shift into corresponding power readings. The quantitative relationship linking phase shift to power output was rigorously characterized and utilized as the basis for estimating volatile gas concentration. Finally, a dedicated LabVIEW-based platform was developed for real-time, quantitative volatile gas monitoring. This integrated measurement system demonstrates excellent detection limits (300 ppm for acetone, 200 ppm for ethanol) and exhibits robust mitigation of measurement artifacts caused by ambient temperature and humidity fluctuations. Comprehensive theoretical analysis and experimental results jointly validate the efficacy of the proposed multiport network and RCR volatile gas sensing architecture.
Open AccessA Multiport Network-Based Integrated Sensing System Using Rectangular Cavity Resonators for Volatile Organic Compounds
This work presents a novel microwave sensor system for volatile gas detection, integrating sensing elements based on rectangular cavity resonators (RCR) and multiport demodulation circuitry. Initially, a pump-through gas sensing element utilizing an RCR was developed, and its core sensing functionality was experimentally validated. Subsequently, a rat-race coupler was employed to seamlessly integrate two such rectangular cavity resonator elements—serving as reference and sensing branches—within the multiport demodulation network. This configuration enabled an in-depth investigation of the network’s operating principle, elucidating the critical relationship between the reference and sensing arms. The demodulation network translates the critical output phase shift into corresponding power readings. The quantitative relationship linking phase shift to power output was rigorously characterized and utilized as the basis for estimating volatile gas concentration. Finally, a dedicated LabVIEW-based platform was developed for real-time, quantitative volatile gas monitoring. This integrated measurement system demonstrates excellent detection limits (300 ppm for acetone, 200 ppm for ethanol) and exhibits robust mitigation of measurement artifacts caused by ambient temperature and humidity fluctuations. Comprehensive theoretical analysis and experimental results jointly validate the efficacy of the proposed multiport network and RCR volatile gas sensing architecture.
- 21 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74  (00189456) , 1-11
An Injection-Locked-Oscillation-Based SIW Shorted Coaxial-Line Active Sensor for Detecting the MNPs Content in Water-Based Ferrofluid
A novel shorted coaxial-line resonator (SCR) in substrate integrated waveguide (SIW) configuration is integrated with a negative resistance circuit (NRC) to implement an ultrahigh Q-factor injection-locked-oscillation (ILO)-based active sensor for high-resolution detection to an ultralow magnetic nanoparticles (MNPs) content in water-based ferrofluid (WFF). Two microfluidic chips, one of which is etched for a dielectric sensing channel and the other for a magnetic sensing channel, are embedded into the highly concentrated time harmonic E-field and H-field distributions region of the SIW SCR ILO-based active sensor, respectively. Then, WFF with different MNPs content is injected into the dielectric and magnetic sensing channels, and its dielectric and magnetic properties are used to detect the MNPs content, respectively. During the solution replacement, the corresponding ILO frequency shifts are recorded in real time by the LabVIEW-based ILO frequency monitoring system, and then the ILO frequency shifts in a stable convergence state are used to characterize the MNPs content in these two sensing channels. The minimum MNPs content in WFF detected by utilizing both electrical and magnetic properties is 0.25%. Besides, a radially magnetized cylindrical magnet is cleverly embedded in the hollow inner conductor of the SCR to capture MNPs flowing through the magnetic sensing channel. Then, the MNPs will be gradually concentrated in the whole magnetic sensing channel due to the enrichment effects, and the corresponding ILO frequency shift rate is used as the response parameter to further improve the minimum detectable MNPs content to 0.125%.
- 21 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74  (00189456) , 1-11
An Injection-Locked-Oscillation-Based SIW Shorted Coaxial-Line Active Sensor for Detecting the MNPs Content in Water-Based Ferrofluid
A novel shorted coaxial-line resonator (SCR) in substrate integrated waveguide (SIW) configuration is integrated with a negative resistance circuit (NRC) to implement an ultrahigh Q-factor injection-locked-oscillation (ILO)-based active sensor for high-resolution detection to an ultralow magnetic nanoparticles (MNPs) content in water-based ferrofluid (WFF). Two microfluidic chips, one of which is etched for a dielectric sensing channel and the other for a magnetic sensing channel, are embedded into the highly concentrated time harmonic E-field and H-field distributions region of the SIW SCR ILO-based active sensor, respectively. Then, WFF with different MNPs content is injected into the dielectric and magnetic sensing channels, and its dielectric and magnetic properties are used to detect the MNPs content, respectively. During the solution replacement, the corresponding ILO frequency shifts are recorded in real time by the LabVIEW-based ILO frequency monitoring system, and then the ILO frequency shifts in a stable convergence state are used to characterize the MNPs content in these two sensing channels. The minimum MNPs content in WFF detected by utilizing both electrical and magnetic properties is 0.25%. Besides, a radially magnetized cylindrical magnet is cleverly embedded in the hollow inner conductor of the SCR to capture MNPs flowing through the magnetic sensing channel. Then, the MNPs will be gradually concentrated in the whole magnetic sensing channel due to the enrichment effects, and the corresponding ILO frequency shift rate is used as the response parameter to further improve the minimum detectable MNPs content to 0.125%.
- 11 August 2025
- Published by Elsevier in Measurement
- Vol. 257
Study of gasoline quality evaluation based on substrate integrated waveguide back-to-back reentrant cavity resonator sensing system
- 11 August 2025
- Published by Elsevier in Measurement
- Vol. 257
Study of gasoline quality evaluation based on substrate integrated waveguide back-to-back reentrant cavity resonator sensing system
- 20 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74  (00189456) , 1-11
Injection-Locked-Oscillation-Based Active Sensor on Folded SIW Dual Re-Entrant Cavities Resonator for High-Resolution Detection to VOC Concentration
In this paper, an injection-locked-oscillation (ILO)-based active microwave sensor formed by a folded substrate integrated waveguide (FSIW) dual re-entrant cavities resonator (DRECR) coupled with a negative resistance circuit (NRC) is proposed to perform high-resolution detection to volatile organic compounds (VOCs). First, the folding technique is used to longitudinally distribute the two strongly induced E-field regions, which enables miniaturization and high sensitivity. To further increase sensitivity, polydimethylsiloxane (PDMS) is used as a sensitive material deposited in the two gap sensing regions. Subsequently, the FSIW DRECR is coupled with an NRC to implement a negative-resistance (NR)-based voltage-controlled oscillator (VCO). By injecting a wideband low-power-level swept signal from a vector network analyzer (VNA), the ILO signal with a very small lock range is obtained to form a very sharp transmission coefficient S21 for high-resolution VOC detection. Finally, a series of LabVIEW-based experiments are performed for ethanol and acetone when the ILO-based active microwave sensor operates in both active and passive modes. The measured results indicate that the FSIW DRECR sensor in the active mode demonstrates a higher Q-factor (104 for the passive mode and 25000 for the active mode), a lower self-shift noise Δfself (4.3 MHz for the passive mode and 19 kHz for the active mode), and a wider concentration range of VOCs, proving that the ILO-based FSIW DRECR sensors in the active mode can easily realize highresolution detection to VOC compared to that in the passive mode.
- 20 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74  (00189456) , 1-11
Injection-Locked-Oscillation-Based Active Sensor on Folded SIW Dual Re-Entrant Cavities Resonator for High-Resolution Detection to VOC Concentration
In this paper, an injection-locked-oscillation (ILO)-based active microwave sensor formed by a folded substrate integrated waveguide (FSIW) dual re-entrant cavities resonator (DRECR) coupled with a negative resistance circuit (NRC) is proposed to perform high-resolution detection to volatile organic compounds (VOCs). First, the folding technique is used to longitudinally distribute the two strongly induced E-field regions, which enables miniaturization and high sensitivity. To further increase sensitivity, polydimethylsiloxane (PDMS) is used as a sensitive material deposited in the two gap sensing regions. Subsequently, the FSIW DRECR is coupled with an NRC to implement a negative-resistance (NR)-based voltage-controlled oscillator (VCO). By injecting a wideband low-power-level swept signal from a vector network analyzer (VNA), the ILO signal with a very small lock range is obtained to form a very sharp transmission coefficient S21 for high-resolution VOC detection. Finally, a series of LabVIEW-based experiments are performed for ethanol and acetone when the ILO-based active microwave sensor operates in both active and passive modes. The measured results indicate that the FSIW DRECR sensor in the active mode demonstrates a higher Q-factor (104 for the passive mode and 25000 for the active mode), a lower self-shift noise Δfself (4.3 MHz for the passive mode and 19 kHz for the active mode), and a wider concentration range of VOCs, proving that the ILO-based FSIW DRECR sensors in the active mode can easily realize highresolution detection to VOC compared to that in the passive mode.
- 11 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 73  (5) , 2739-2751
Sensitivity-Enhanced Multiport-Network-Based Sensor for Moisture Detection in Lubricant Oil
In this article, a multiport-network-based microwave sensor integrated with an interference circuit is proposed to detect the moisture content in lubricant oil for the purpose of phase-sensitivity enhancement. First, a composite right-/left-handed (CRLH) transmission lines (TLs)-based sensing element is developed to carry moisture content information characterized by a change in the transmission phase. Then, two CRLH TLs-based sensing elements in the differential configuration are integrated into an interference circuit, and the coupling coefficients of the hybrid coupler in the interference circuit are investigated to analyze the power distribution ratio between the reference and sensing branches and obtain an output phase-sensitivity enhancement. Subsequently, the output phase from the interference circuit is translated into power readings through the multiport circuit, and then the corresponding relationship between them is analyzed and utilized to estimate the moisture content in lubricant oil. Finally, a LabVIEW-based real-time measurement system is developed to characterize the moisture content in lubricant oil with the volume fraction from 0.2% to 15%. The measured results exhibit an improvement in phase sensitivity from 1.03 $^{\circ}$ /(v%) to 3.82 $^{\circ}$ /(v%) compared to the CRLH TLs-based sensing elements itself. Both theoretical analysis and experimental results validate the sensitivity enhancement scheme by use of a multiport-network-based topological structure.
- 11 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 73  (5) , 2739-2751
Sensitivity-Enhanced Multiport-Network-Based Sensor for Moisture Detection in Lubricant Oil
In this article, a multiport-network-based microwave sensor integrated with an interference circuit is proposed to detect the moisture content in lubricant oil for the purpose of phase-sensitivity enhancement. First, a composite right-/left-handed (CRLH) transmission lines (TLs)-based sensing element is developed to carry moisture content information characterized by a change in the transmission phase. Then, two CRLH TLs-based sensing elements in the differential configuration are integrated into an interference circuit, and the coupling coefficients of the hybrid coupler in the interference circuit are investigated to analyze the power distribution ratio between the reference and sensing branches and obtain an output phase-sensitivity enhancement. Subsequently, the output phase from the interference circuit is translated into power readings through the multiport circuit, and then the corresponding relationship between them is analyzed and utilized to estimate the moisture content in lubricant oil. Finally, a LabVIEW-based real-time measurement system is developed to characterize the moisture content in lubricant oil with the volume fraction from 0.2% to 15%. The measured results exhibit an improvement in phase sensitivity from 1.03 $^{\circ}$ /(v%) to 3.82 $^{\circ}$ /(v%) compared to the CRLH TLs-based sensing elements itself. Both theoretical analysis and experimental results validate the sensitivity enhancement scheme by use of a multiport-network-based topological structure.
- 25 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25  (1) , 476-488
A Microwave Sensing System Based on Reflective RF Oscillator and High-Sensitivity Coupled-Line Sensor for Extracting Permittivity of Liquid Samples
A microwave sensing system based on reflective RF oscillator and high-sensitivity coupled-line sensor is proposed in this manuscript. The coupled microstrip lines with the pass through and isolation ports open-circuited, and the coupling port short-circuited is adopted to analyze the conditions for achieving the maximum phase variation of reflection coefficient by Z-parameter matrix. The maximum value of phase variation of reflection coefficient is obtained by acquiring the optimal values of odd- and even-mode characteristic impedances, and electrical length of coupled-line. The RF oscillator designed by optimal coupled-line sensor and pseudomorphic high electron mobility transistor (PHEMT) ATF34143 can transform the relationship between reflection coefficient phase and permittivity into the relation between oscillation frequency and permittivity. Further, the microwave components, including power divider, phase shifter, mixer, and low-pass filter (LPF) are cascaded with the RF oscillator to form the microwave sensing system. In measurement, the measured sensitivities of two circuit channels are about 0.44% and 0.31%, respectively, which is separately improved by hundreds of times and dozens of times compared to the other recently reported detection systems. The proposed microwave sensing system has the merits of high sensitivity, non-use of Vector Network Analyzer (VNA), and high portability, which determines it to be an excellent role in the field of detecting liquid samples.
- 25 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25  (1) , 476-488
A Microwave Sensing System Based on Reflective RF Oscillator and High-Sensitivity Coupled-Line Sensor for Extracting Permittivity of Liquid Samples
A microwave sensing system based on reflective RF oscillator and high-sensitivity coupled-line sensor is proposed in this manuscript. The coupled microstrip lines with the pass through and isolation ports open-circuited, and the coupling port short-circuited is adopted to analyze the conditions for achieving the maximum phase variation of reflection coefficient by Z-parameter matrix. The maximum value of phase variation of reflection coefficient is obtained by acquiring the optimal values of odd- and even-mode characteristic impedances, and electrical length of coupled-line. The RF oscillator designed by optimal coupled-line sensor and pseudomorphic high electron mobility transistor (PHEMT) ATF34143 can transform the relationship between reflection coefficient phase and permittivity into the relation between oscillation frequency and permittivity. Further, the microwave components, including power divider, phase shifter, mixer, and low-pass filter (LPF) are cascaded with the RF oscillator to form the microwave sensing system. In measurement, the measured sensitivities of two circuit channels are about 0.44% and 0.31%, respectively, which is separately improved by hundreds of times and dozens of times compared to the other recently reported detection systems. The proposed microwave sensing system has the merits of high sensitivity, non-use of Vector Network Analyzer (VNA), and high portability, which determines it to be an excellent role in the field of detecting liquid samples.
- 16 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24  (13) , 20549-20558
A Novel Substrate Integrated Waveguide Shorted Coaxial Resonator for Characterizing Complex Permittivity of Liquids and Solid Content of Water-Based Ferrofluid
A novel substrate integrated waveguide (SIW) shorted coaxial resonator (SCR), embedded with a dual-channel microfluidic, is proposed to implement a microwave liquid sensor. The novel SIW SCR not only demonstrates the highly concentrated E-field by innovatively inserting an annular parallel plate capacitance between the outer conductors of the SIW SCR, but also represents the uniformly distributed strong H-field intensity distribution between the inner and outer conductors of the SIW SCR, which is similar to those of the traditional coaxial line. Then, the dielectric and magnetic sensing channel in the dual-channel microfluidic are skillfully designed to be placed in the strong E-field and H-field regions of the SIW SCR, which are used to characterize the complex permittivity of liquids and the solid content of water-based Ferrofluid (WFF), respectively. In addition, the equivalent lumped circuit model of the SIW SCR is successfully established to analyze its sensing mechanism, and the values of the equivalent lumped elements are extracted. Moreover, a LabVIEW-based real-time test system is combined with an averaging data processing method to ensure the reliability of the measured results, and the maximum measurement errors of the complex permittivity and solid content of WFF are 3.83% and 2.26%, respectively. The SIW SCR is an excellent candidate for accurate characterize the liquid, and provides technical support for the non-destructive testing of liquid materials.
- 16 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24  (13) , 20549-20558
A Novel Substrate Integrated Waveguide Shorted Coaxial Resonator for Characterizing Complex Permittivity of Liquids and Solid Content of Water-Based Ferrofluid
A novel substrate integrated waveguide (SIW) shorted coaxial resonator (SCR), embedded with a dual-channel microfluidic, is proposed to implement a microwave liquid sensor. The novel SIW SCR not only demonstrates the highly concentrated E-field by innovatively inserting an annular parallel plate capacitance between the outer conductors of the SIW SCR, but also represents the uniformly distributed strong H-field intensity distribution between the inner and outer conductors of the SIW SCR, which is similar to those of the traditional coaxial line. Then, the dielectric and magnetic sensing channel in the dual-channel microfluidic are skillfully designed to be placed in the strong E-field and H-field regions of the SIW SCR, which are used to characterize the complex permittivity of liquids and the solid content of water-based Ferrofluid (WFF), respectively. In addition, the equivalent lumped circuit model of the SIW SCR is successfully established to analyze its sensing mechanism, and the values of the equivalent lumped elements are extracted. Moreover, a LabVIEW-based real-time test system is combined with an averaging data processing method to ensure the reliability of the measured results, and the maximum measurement errors of the complex permittivity and solid content of WFF are 3.83% and 2.26%, respectively. The SIW SCR is an excellent candidate for accurate characterize the liquid, and provides technical support for the non-destructive testing of liquid materials.
- 10 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 72  (9) , 5406-5419
Oscillation-Based Active Sensor on SIW Reentrant Cavity Resonator for Self-Sustained Ultralow Concentration Detection to Saline Solution
A back-to-back reentrant cavity resonator (BTB RECR) in substrate integrated waveguide (SIW) configuration is integrated with a negative resistance oscillation (NRO) circuit to implement an SIW BTB RECR NRO-based active sensor for self-sustained sensing application. The dependence of sensitivity on the polarization between the dielectric sample and the induced E -field of the passive SIW BTB RECR is investigated to obtain sensitivity as high as possible. A multitask LabVIEW-based real-time test system, which can avoid disassembly and ensure the reliability of the measured results, is built up to selectively measure for transmission coefficient S $_{{21}}$ and frequency spectrum through a microwave switch. During the process of real-time replacement of deionized (DI) water reference solution with NaCl solution in dielectric sensing channel, the in-between real-time recorded oscillation frequency is cleverly used as the frequency-modulated (FM) input signal to the delay-line-based frequency demodulator and is transferred to in-phase V $_{{\text{I}}}$ and quadrature V $_{{\text{Q}}}$ dc voltages. Then, the modulated V $_{{\text{I}}}$ and V $_{{\text{Q}}}$ dc voltages are postprocessed into phase angle by using arctangent algorithm, and the phase angle in stable convergence state is finally used as response parameter for self-sustaining measurement for the concentration of NaCl solution. The NRO-based active sensor demonstrates a phase angle self-shift noise of 7.8 $^{\circ}$ and a high-resolution detection to NaCl solution at low concentration level from 2.5 to 80 mM/L and high concentration level from 100 to 800 mM/L. The measured minimum detectable lower limit concentration is 2.5 mM/L, and maximum sensitivity is 40 kHz/mM $\cdot$ L $^{{-1}}$ (0.31 $^{\circ}$ /mM $\cdot$ L $^{{-1}}$ ).
- 10 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 72  (9) , 5406-5419
Oscillation-Based Active Sensor on SIW Reentrant Cavity Resonator for Self-Sustained Ultralow Concentration Detection to Saline Solution
A back-to-back reentrant cavity resonator (BTB RECR) in substrate integrated waveguide (SIW) configuration is integrated with a negative resistance oscillation (NRO) circuit to implement an SIW BTB RECR NRO-based active sensor for self-sustained sensing application. The dependence of sensitivity on the polarization between the dielectric sample and the induced E -field of the passive SIW BTB RECR is investigated to obtain sensitivity as high as possible. A multitask LabVIEW-based real-time test system, which can avoid disassembly and ensure the reliability of the measured results, is built up to selectively measure for transmission coefficient S $_{{21}}$ and frequency spectrum through a microwave switch. During the process of real-time replacement of deionized (DI) water reference solution with NaCl solution in dielectric sensing channel, the in-between real-time recorded oscillation frequency is cleverly used as the frequency-modulated (FM) input signal to the delay-line-based frequency demodulator and is transferred to in-phase V $_{{\text{I}}}$ and quadrature V $_{{\text{Q}}}$ dc voltages. Then, the modulated V $_{{\text{I}}}$ and V $_{{\text{Q}}}$ dc voltages are postprocessed into phase angle by using arctangent algorithm, and the phase angle in stable convergence state is finally used as response parameter for self-sustaining measurement for the concentration of NaCl solution. The NRO-based active sensor demonstrates a phase angle self-shift noise of 7.8 $^{\circ}$ and a high-resolution detection to NaCl solution at low concentration level from 2.5 to 80 mM/L and high concentration level from 100 to 800 mM/L. The measured minimum detectable lower limit concentration is 2.5 mM/L, and maximum sensitivity is 40 kHz/mM $\cdot$ L $^{{-1}}$ (0.31 $^{\circ}$ /mM $\cdot$ L $^{{-1}}$ ).
- 13 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24  (3) , 2734-2745
A Tunable Interferometer for High Sensitivity and Resolution Humidity Sensing
Here, a six-port network, consisting of power splitter/combiner, two hybrid couplers and a composite right-/left-handed (CRLH) transmission-lines (TLs) voltage-controlled phase shifter (CRLH-TLs-VC PS), is loaded with the reference and sensing re-entrant cavity resonators (RECRs) in substrate integrated waveguide (SIW) configuration to implement a tunable microwave interferometer for high sensitivity and resolution humidity sensing. The humidity sensitive material PEDOT:PSS is deposited only in the sensing SIW RECR to form a phase difference between the reference and sensing RECRs. Then, the phase difference is loaded into the transmission branch of the six-port network and can be easily compensated to 180° by a positive phase provided by the CRLH-TLs-VC PS. Besides, the interferometer implemented in differential configuration not only avoids the use of an additional attenuator, but also can suppress the temperature effect. A series of LabVIEW-based real-time measurement experiments are performed using a vector network analyzer to demonstrate the good humidity response characteristics, such as the high sensitivity of 678.85 kHz/%RH, the high resolution for the discriminable minimum RH change in the range from 0.37% to 5.5%, and the low temperature coefficient of frequency (TCF) of -10.699 ppm/°C.
- 13 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24  (3) , 2734-2745
A Tunable Interferometer for High Sensitivity and Resolution Humidity Sensing
Here, a six-port network, consisting of power splitter/combiner, two hybrid couplers and a composite right-/left-handed (CRLH) transmission-lines (TLs) voltage-controlled phase shifter (CRLH-TLs-VC PS), is loaded with the reference and sensing re-entrant cavity resonators (RECRs) in substrate integrated waveguide (SIW) configuration to implement a tunable microwave interferometer for high sensitivity and resolution humidity sensing. The humidity sensitive material PEDOT:PSS is deposited only in the sensing SIW RECR to form a phase difference between the reference and sensing RECRs. Then, the phase difference is loaded into the transmission branch of the six-port network and can be easily compensated to 180° by a positive phase provided by the CRLH-TLs-VC PS. Besides, the interferometer implemented in differential configuration not only avoids the use of an additional attenuator, but also can suppress the temperature effect. A series of LabVIEW-based real-time measurement experiments are performed using a vector network analyzer to demonstrate the good humidity response characteristics, such as the high sensitivity of 678.85 kHz/%RH, the high resolution for the discriminable minimum RH change in the range from 0.37% to 5.5%, and the low temperature coefficient of frequency (TCF) of -10.699 ppm/°C.