JLJeffery Blythe Larsen

Jeffery Blythe Larsen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jeffery Blythe Larsen has a total of 2 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Noise Levels Among Spectators at an Intercollegiate Sporting Event

    by Beau England, Jeffery Blythe Larsen

    Purpose: The intensity of noise levels in a basketball arena during games, as well as the hearing sensitivity of attendees, was measured for the purpose of assessing the impact of the noise on hearing thresholds. Method: Noise levels at 10 intercollegiate basketball games were measured with a dosimeter affixed on the shoulders of attendees. Hearing thresholds and distortion product otoacoustic emissions were measured for 20 participants just before attending a basketball game and within an hour of the end of the game to determine whether changes in hearing thresholds resulted from exposure to the sound levels within the arena during the games. Results: Participants demonstrated temporary shifts in pure-tone thresholds and reductions in the intensity of their otoacoustic emissions after attendance at 1 of the basketball games. Dosimeter measurements showed that noise at 6 of the 10 basketball games exceeded acceptable intensity levels when compared with a national workplace noise exposure standard. Conclusion: Although noise intensities, on average, did not exceed workplace exposure standards, universities would be wise to be proactive in warning spectators about the potential dangers of noise exposure at sporting events, make earplugs available to interested spectators, and implement a hearing conservation program for employees working in noise.


  • The Effect of Classroom Amplification on the Signal-to-Noise Ratio in Classrooms While Class Is in Session

    by Jeffery B. Larsen, James C. Blair

    Purpose: The purpose of this study was to measure the signal-to-noise ratios in classrooms while class was in session and students were interacting with the teacher and each other. Method: Measurements of noise and reverberation were collected for 5 different classrooms in 3 different schools while class was in session. Activities taking place during the measurements were recorded to compare with sound level measures. The use of infrared classroom amplification was compared with no amplification. Results/Conclusion: The results revealed that when classroom amplification was used, students heard the teacher’s voice at a level that was an average of 13 dB above the noise floor as compared to an average of +2 dB above the noise floor without amplification.