Mansze Mok
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Mansze Mok has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Richard C. Dowell
Department of Neurodegenerative Diseases, Hertie Institute for Clinical Brain Research, University of Tübingen, Tübingen, Germany
2 shared publications- Adam P. Vogel
The University of Melbourne
1 shared publication - Colleen M. Holt
Department of Community and Clinical Health, La Trobe University, Bundoora, Victoria, Australia
1 shared publication - David Bruce Grayden
Department of Biomedical Engineering, University of Melbourne
1 shared publication David Lawrence
University of Melbourne
1 shared publication- Kathy Yuet Sheung Lee
School of Social Work, University of Texas at Arlington, Arlington, TX, USA
1 shared publication
Latest Publications
- 1 November 2017
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 38 (6) , e359-e368
Cantonese Tone Perception for Children Who Use a Hearing Aid and a Cochlear Implant in Opposite Ears
The ability to recognize tones is vital for speech perception in tonal languages. Cantonese has six tones, which are differentiated almost exclusively by pitch cues (tones 1 to 6). The differences in pitch contours among the tones are subtle, making Cantonese a challenging language for cochlear implant users. The addition of a hearing aid has been shown to improve speech perception in nontonal languages and in Mandarin Chinese. This study (1) investigates the Cantonese tone perception ability of children who use a cochlear implant and a hearing aid in opposite ears; (2) evaluates the effect of varying pitch height and pitch contour cues on Cantonese tone perception for these children; and (3) compares the Cantonese tone perception ability for using a hearing aid and a cochlear implant together versus an implant alone. Eight native Cantonese speaking children using a cochlear implant and a hearing aid in opposite ears were assessed for tone perception and word identification. The tone perception test involved discriminating and ranking tone pairs from natural and artificially manipulated Cantonese tones with various pitch heights and/or pitch contours. The word identification test involved identifying Cantonese words in a four-alternative forced-choice task. All tests were performed in two device conditions: (1) cochlear implant and hearing aid together and (2) implant alone. Seven of the 8 subjects performed significantly above chance in both tests using the cochlear implant alone. Results showed that both pitch height and/or pitch direction were important perceptual cues for implant users. Perception for some tones was improved by increasing the pitch height differences between the tones. The ability to discriminate and rank the tone 2/tone 5 contrast and the tone 4/tone 6 contrast was poor, as the tones in these contrasts are similar in pitch contours and onset frequencies. No significant improvement was observed after artificially increasing the pitch offset differences between the tones in the tone 2/tone 5 and the tone 4/tone 6 contrasts. Tone perception results were significantly better with the addition of the hearing aid in the nonimplanted ear compared with using the implant alone; however, word identification results were not significantly different between using the implant alone and using both the hearing aid and the implant together. None of the subjects performed worse in tone perception or in word identification when the hearing aid was added. Reduced ability to perceive pitch contour cues, even when artificially exaggerated, may explain some of the difficulties in Cantonese word recognition for implant users. The addition of a contralateral hearing aid could be beneficial for Cantonese tone perception for some individuals with a unilateral implant. The results encouraged Cantonese speakers to trial a hearing aid in the nonimplanted ear when using a cochlear implant.
- 1 November 2017
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 38 (6) , e359-e368
Cantonese Tone Perception for Children Who Use a Hearing Aid and a Cochlear Implant in Opposite Ears
The ability to recognize tones is vital for speech perception in tonal languages. Cantonese has six tones, which are differentiated almost exclusively by pitch cues (tones 1 to 6). The differences in pitch contours among the tones are subtle, making Cantonese a challenging language for cochlear implant users. The addition of a hearing aid has been shown to improve speech perception in nontonal languages and in Mandarin Chinese. This study (1) investigates the Cantonese tone perception ability of children who use a cochlear implant and a hearing aid in opposite ears; (2) evaluates the effect of varying pitch height and pitch contour cues on Cantonese tone perception for these children; and (3) compares the Cantonese tone perception ability for using a hearing aid and a cochlear implant together versus an implant alone. Eight native Cantonese speaking children using a cochlear implant and a hearing aid in opposite ears were assessed for tone perception and word identification. The tone perception test involved discriminating and ranking tone pairs from natural and artificially manipulated Cantonese tones with various pitch heights and/or pitch contours. The word identification test involved identifying Cantonese words in a four-alternative forced-choice task. All tests were performed in two device conditions: (1) cochlear implant and hearing aid together and (2) implant alone. Seven of the 8 subjects performed significantly above chance in both tests using the cochlear implant alone. Results showed that both pitch height and/or pitch direction were important perceptual cues for implant users. Perception for some tones was improved by increasing the pitch height differences between the tones. The ability to discriminate and rank the tone 2/tone 5 contrast and the tone 4/tone 6 contrast was poor, as the tones in these contrasts are similar in pitch contours and onset frequencies. No significant improvement was observed after artificially increasing the pitch offset differences between the tones in the tone 2/tone 5 and the tone 4/tone 6 contrasts. Tone perception results were significantly better with the addition of the hearing aid in the nonimplanted ear compared with using the implant alone; however, word identification results were not significantly different between using the implant alone and using both the hearing aid and the implant together. None of the subjects performed worse in tone perception or in word identification when the hearing aid was added. Reduced ability to perceive pitch contour cues, even when artificially exaggerated, may explain some of the difficulties in Cantonese word recognition for implant users. The addition of a contralateral hearing aid could be beneficial for Cantonese tone perception for some individuals with a unilateral implant. The results encouraged Cantonese speakers to trial a hearing aid in the nonimplanted ear when using a cochlear implant.
- 1 April 2006
- Published by American Speech Language Hearing Association in Journal of Speech, Language, and Hearing Research
- Vol. 49 (2) , 338-351
Speech Perception for Adults Who Use Hearing Aids in Conjunction With Cochlear Implants in Opposite Ears
This study aimed to (a) investigate the effect of using a hearing aid in conjunction with a cochlear implant in opposite ears on speech perception in quiet and in noise, (b) identify the speech information obtained from a hearing aid that is additive to the information obtained from a cochlear implant, and (c) explore the relationship between aided thresholds in the nonimplanted ear and speech perception benefit from wearing a hearing aid in conjunction with a cochlear implant in opposite ears. Fourteen adults who used the Nucleus 24 cochlear implant system in 1 ear participated in the study. All participants had either used a hearing aid in the nonimplanted ear for at least 75% of waking hours after cochlear implantation, and/or, hearing loss less than 90 dB HL in the low frequencies in the nonimplanted ear. Speech perception was evaluated in 3 conditions: cochlear implant alone (CI), hearing aid alone (HA), and cochlear implant in conjunction with hearing aid in opposite ears (CIHA). Three speech perception tests were used: consonant–vowel nucleus–consonant (CNC) words in quiet, City University of New York style (CUNY) sentences in coincident signal and noise, and spondees in coincidental and spatially separated signal and noise. Information transmission analyses were performed on the CNC responses. Of the 14 participants tested, 6 showed significant bimodal benefit on open-set speech perception measures and 5 showed benefit on close-set spondees. However, 2 participants showed poorer speech perception with CIHA than CI in at least 1 of the speech perception tests. Results of information transmission analyses showed that bimodal benefit (performance with CIHA minus that with CI) in quiet arises from improved perception of the low frequency components in speech. Results showed that participants with poorer aided thresholds in the mid-to-high frequencies demonstrated greater bimodal benefit. It is possible that the mid-to-high frequency information provided by the hearing aids may be conflicting with the cochlear implants.
- 1 April 2006
- Published by American Speech Language Hearing Association in Journal of Speech, Language, and Hearing Research
- Vol. 49 (2) , 338-351
Speech Perception for Adults Who Use Hearing Aids in Conjunction With Cochlear Implants in Opposite Ears
This study aimed to (a) investigate the effect of using a hearing aid in conjunction with a cochlear implant in opposite ears on speech perception in quiet and in noise, (b) identify the speech information obtained from a hearing aid that is additive to the information obtained from a cochlear implant, and (c) explore the relationship between aided thresholds in the nonimplanted ear and speech perception benefit from wearing a hearing aid in conjunction with a cochlear implant in opposite ears. Fourteen adults who used the Nucleus 24 cochlear implant system in 1 ear participated in the study. All participants had either used a hearing aid in the nonimplanted ear for at least 75% of waking hours after cochlear implantation, and/or, hearing loss less than 90 dB HL in the low frequencies in the nonimplanted ear. Speech perception was evaluated in 3 conditions: cochlear implant alone (CI), hearing aid alone (HA), and cochlear implant in conjunction with hearing aid in opposite ears (CIHA). Three speech perception tests were used: consonant–vowel nucleus–consonant (CNC) words in quiet, City University of New York style (CUNY) sentences in coincident signal and noise, and spondees in coincidental and spatially separated signal and noise. Information transmission analyses were performed on the CNC responses. Of the 14 participants tested, 6 showed significant bimodal benefit on open-set speech perception measures and 5 showed benefit on close-set spondees. However, 2 participants showed poorer speech perception with CIHA than CI in at least 1 of the speech perception tests. Results of information transmission analyses showed that bimodal benefit (performance with CIHA minus that with CI) in quiet arises from improved perception of the low frequency components in speech. Results showed that participants with poorer aided thresholds in the mid-to-high frequencies demonstrated greater bimodal benefit. It is possible that the mid-to-high frequency information provided by the hearing aids may be conflicting with the cochlear implants.