Marko Pavlovic
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Marko Pavlovic has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Zlatko Marković
University of Belgrade - Faculty of Civil Engineering,Belgrade,Serbia
3 shared publications Dragan Budjevac
2 shared publications- Milan Spremić
University of Belgrade - Faculty of Civil Engineering,Belgrade,Serbia
2 shared publications - Milan Veljkovic
Univ. of Technology
2 shared publications - Aldina Santiago
ISISE—Institute for Sustainability and Innovation in Structural, Department of Civil Engineering, University of Coimbra, 3030-788 Coimbra, Portugal
1 shared publication - Fernanda Lopes
Univ. of Technology
1 shared publication
Latest Publications
- 18 February 2016
- Published by American Society of Civil Engineers (ASCE)
- p. 687-702
Headed Shear Studs versus High-Strength Bolts in Prefabricated Composite Decks
Prefabricated steel and concrete composite decks are an interesting option to improve competitiveness and sustainability of the composite structures. Longitudinal shear connection is usually established by grouped headed studs, but possible alternative solution is to use bolted shear connectors. Welded headed studs and bolts (grade 8.8) are experimentally examined in the push-out tests (four tests on each). The same arrangement and dimensions of shear connectors (16 mm diameter and 100 mm height above flange) are considered and their resistances and behaviour are compared. Experimental results showed that headed studs and bolted shear connectors have similar shear resistance, while headed studs are more ductile. FEA is performed by ABAQUS/Explicit solver with damage material models to get more insight into behaviour of the specimens. FEA shows rather good agreement with experimental results. Influence of the bolt to hole clearance on the behaviour of specimens with bolted shear connectors is analysed and discussed.
- 18 February 2016
- Published by American Society of Civil Engineers (ASCE)
- p. 687-702
Headed Shear Studs versus High-Strength Bolts in Prefabricated Composite Decks
Prefabricated steel and concrete composite decks are an interesting option to improve competitiveness and sustainability of the composite structures. Longitudinal shear connection is usually established by grouped headed studs, but possible alternative solution is to use bolted shear connectors. Welded headed studs and bolts (grade 8.8) are experimentally examined in the push-out tests (four tests on each). The same arrangement and dimensions of shear connectors (16 mm diameter and 100 mm height above flange) are considered and their resistances and behaviour are compared. Experimental results showed that headed studs and bolted shear connectors have similar shear resistance, while headed studs are more ductile. FEA is performed by ABAQUS/Explicit solver with damage material models to get more insight into behaviour of the specimens. FEA shows rather good agreement with experimental results. Influence of the bolt to hole clearance on the behaviour of specimens with bolted shear connectors is analysed and discussed.
- 18 February 2016
- Published by American Society of Civil Engineers (ASCE)
- p. 199-213
Numerical Investigation of the Behaviour of Steel Beams in Steel-Concrete Composite Frames
The methods proposed by the design codes for single member design in fire situation assume that these members are isolated in their response. The real response of structural members such as beams is, however, more complex due to thermal expansion and the presence of restraints against this expansion by the surrounding structure. It is therefore imperative to study the response of structure at high temperature in a way which includes its interaction with its surroundings such as in a full-scale fire test and in numerical analysis. This paper focuses on the numerical investigation of steel beams, with a concrete slab and connected to concrete filled tubular (CFT) columns through reverse channel connections. The finite element software ABAQUS has been used in this study. The aim of the investigation is to study the behaviour of the composite steel-concrete beam exposed to increasing temperature in fire.
- 18 February 2016
- Published by American Society of Civil Engineers (ASCE)
- p. 199-213
Numerical Investigation of the Behaviour of Steel Beams in Steel-Concrete Composite Frames
The methods proposed by the design codes for single member design in fire situation assume that these members are isolated in their response. The real response of structural members such as beams is, however, more complex due to thermal expansion and the presence of restraints against this expansion by the surrounding structure. It is therefore imperative to study the response of structure at high temperature in a way which includes its interaction with its surroundings such as in a full-scale fire test and in numerical analysis. This paper focuses on the numerical investigation of steel beams, with a concrete slab and connected to concrete filled tubular (CFT) columns through reverse channel connections. The finite element software ABAQUS has been used in this study. The aim of the investigation is to study the behaviour of the composite steel-concrete beam exposed to increasing temperature in fire.
- Open Access
- 1 January 2016
- Published by Centre for Evaluation in Education and Science (CEON/CEES) in Građevinski materijali i konstrukcije
- Vol. 59 (4) , 3-15
Calibration of the bolt pretension by strain gauges vs. FEA
When applying high strength bolts in friction connections, a load-bearing capacity depends on pretension force in the bolts as well as on friction coefficient found on friction surfaces. It is important to get the reliable value of the pretension force, so friction connections often undergo experimental research. In order to use strain gauges, which are inserted into the bolt shank, bolts need to be calibrated before we even use them in experimental research. Research that has been conducted shows a great difference between nominal and experimental strain in bolts, therefore FEA calibration of the bolts had to be carried out. Good results matching were obtained, hence a use of strain gauges was justified even for bolts without a shank.
- 1 January 2016
- Published by Centre for Evaluation in Education and Science (CEON/CEES) in Građevinski materijali i konstrukcije
- Vol. 59 (4) , 3-15
Open AccessCalibration of the bolt pretension by strain gauges vs. FEA
When applying high strength bolts in friction connections, a load-bearing capacity depends on pretension force in the bolts as well as on friction coefficient found on friction surfaces. It is important to get the reliable value of the pretension force, so friction connections often undergo experimental research. In order to use strain gauges, which are inserted into the bolt shank, bolts need to be calibrated before we even use them in experimental research. Research that has been conducted shows a great difference between nominal and experimental strain in bolts, therefore FEA calibration of the bolts had to be carried out. Good results matching were obtained, hence a use of strain gauges was justified even for bolts without a shank.
- Open Access
- 1 January 2014
- Published by Centre for Evaluation in Education and Science (CEON/CEES) in Journal of Applied Engineering Science
- Vol. 12 (1) , 75-80
Recent research of shear connection in prefabricated steel-concrete composite beams
Prefabrication of steel-concrete composite decks can improve their competitiveness and sustainability. This paper presents recent studies of longitudinal shear connection at the University of Belgrade, Faculty of Civil Engineering. Grouped welded headed studs and bolted shear connectors, suitable for prefabricated composite construction, has been examined in push-out tests. Totally 30 tests were conducted, and advanced FEA were made using Abaqus/Explicit dynamic solver. Based on the experimental and numerical studies behaviour those two shear connectors are compared.
- 1 January 2014
- Published by Centre for Evaluation in Education and Science (CEON/CEES) in Journal of Applied Engineering Science
- Vol. 12 (1) , 75-80
Open AccessRecent research of shear connection in prefabricated steel-concrete composite beams
Prefabrication of steel-concrete composite decks can improve their competitiveness and sustainability. This paper presents recent studies of longitudinal shear connection at the University of Belgrade, Faculty of Civil Engineering. Grouped welded headed studs and bolted shear connectors, suitable for prefabricated composite construction, has been examined in push-out tests. Totally 30 tests were conducted, and advanced FEA were made using Abaqus/Explicit dynamic solver. Based on the experimental and numerical studies behaviour those two shear connectors are compared.