H. M. Hertz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
H. M. Hertz has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
M. Berglund
Biomedical and X-Ray Physics, Royal Institute of Technology, 10044 Stockholm, Sweden
3 shared publicationsB. A.M. Hansson
Biomedical and X-Ray Physics, Royal Institute of Technology, 10044 Stockholm, Sweden
1 shared publicationD. Hambach
Forschungseinrichtung Röntgenphysik, Georg-August Universität Göttingen, Geiststr. 11, D-37073 Göttingen, Germany
1 shared publicationF. Eriksson
Thin Film Division, Department of Physics (IFM), Linköping University, SE-58183 Linköping, Sweden
1 shared publicationG. A. Johansson
Biomedical and X-Ray Physics, Royal Institute of Technology, SE-10044 Stockholm, Sweden
1 shared publicationG. J. Johansson
Biomedical and X-Ray Physics, Royal Institute of Technology, 10044 Stockholm, Sweden
1 shared publication
Latest Publications
- 1 July 2001
- Published by EDP Sciences in Journal de Physique IV
- Vol. 11 (PR2) , Pr2-389
Liquid-jet laser-plasma X-ray sources for microscopy and lithography
- 1 July 2001
- Published by EDP Sciences in Journal de Physique IV
- Vol. 11 (PR2) , Pr2-389
Liquid-jet laser-plasma X-ray sources for microscopy and lithography
- 1 January 2001
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 72 (1) , 58-62
Compact soft x-ray reflectometer based on a line-emitting laser-plasma source
We describe a compact soft x-ray reflectometer for in-house characterization of water-window multilayer optics. The instrument is based on a line-emitting, liquid-jet, laser-plasma source in combination with angular scanning of the studied multilayer optics. With a proper choice of target liquid and thin-film filters, one or a few lines of well-defined wavelength dominate the spectrum and multilayer periods are measured with an accuracy of 0.003 nm using a multi-line calibration procedure. Absolute reflectivity may also be estimated with the instrument. The typical measurement time is currently 10 min. Although the principles of the reflectometer may be used in the entire soft x-ray and extreme ultraviolet range, the current instrument is primarily directed towards normal-incidence multilayer optics for water-window x-ray microscopy, and is thus demonstrated on multilayers for this wavelength range.- 1 January 2001
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 72 (1) , 58-62
Compact soft x-ray reflectometer based on a line-emitting laser-plasma source
We describe a compact soft x-ray reflectometer for in-house characterization of water-window multilayer optics. The instrument is based on a line-emitting, liquid-jet, laser-plasma source in combination with angular scanning of the studied multilayer optics. With a proper choice of target liquid and thin-film filters, one or a few lines of well-defined wavelength dominate the spectrum and multilayer periods are measured with an accuracy of 0.003 nm using a multi-line calibration procedure. Absolute reflectivity may also be estimated with the instrument. The typical measurement time is currently 10 min. Although the principles of the reflectometer may be used in the entire soft x-ray and extreme ultraviolet range, the current instrument is primarily directed towards normal-incidence multilayer optics for water-window x-ray microscopy, and is thus demonstrated on multilayers for this wavelength range.- 1 March 2000
- Published by Wiley in Journal of Microscopy
- Vol. 197 (3) , 268-273
Compact water‐window transmission X‐ray microscopy
We demonstrate sub‐100 nm resolution water‐window soft X‐ray full‐field transmission microscopy with a compact system. The microscope operates at λ = 3.37 nm and is based on a 100 Hz table‐top regenerative debris‐free droplet‐target laser‐plasma X‐ray source in combination with normal‐incidence multilayer condenser optics for sample illumination. High‐spatial‐resolution imaging is performed with a 7.3% efficiency nickel zone plate and a 1024 × 1024 pixel CCD detector. Images of dry test samples are recorded with exposure times of a few minutes and show features smaller than 60 nm.
- 1 March 2000
- Published by Wiley in Journal of Microscopy
- Vol. 197 (3) , 268-273
Compact water‐window transmission X‐ray microscopy
We demonstrate sub‐100 nm resolution water‐window soft X‐ray full‐field transmission microscopy with a compact system. The microscope operates at λ = 3.37 nm and is based on a 100 Hz table‐top regenerative debris‐free droplet‐target laser‐plasma X‐ray source in combination with normal‐incidence multilayer condenser optics for sample illumination. High‐spatial‐resolution imaging is performed with a 7.3% efficiency nickel zone plate and a 1024 × 1024 pixel CCD detector. Images of dry test samples are recorded with exposure times of a few minutes and show features smaller than 60 nm.
- 1 March 1999
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 70 (3) , 1694-1699
A slit grating spectrograph for quantitative soft x-ray spectroscopy
- 1 March 1999
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 70 (3) , 1694-1699
A slit grating spectrograph for quantitative soft x-ray spectroscopy