ADAnkona Datta

Ankona Datta

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ankona Datta has a total of 97 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    High-Sensitivity, Dual Ratiometric and Turn-on ABATaRs for Multiplexed Temporal Imaging of Ferroptosis Hallmarks in Living Cells

    by Sujit K Das, Heqi Xi, Saurabh Kumar, Katsumasa Fujita, Ankona Datta

    We present a computationally-guided workflow for designing dual turn-on and ratiometric Raman sensors. The workflow has been used to rationally design activity-based alkyne tagged Raman, ABATaR , sensors that overcome the inherently low Raman sensitivity via strategic placement of electron-donating and electron-withdrawing groups. An ABATaR sensing scaffold designed via the workflow afforded ~ 9000 times higher Raman scattering cross-section than the dimethylsulfoxide C-H stretching-mode. The sensitivity of the scaffold was compared to that of 5-ethynyl-2'-deoxyuridine ( EdU ) to determine Raman intensity versus EdU , RIE, a parameter used to benchmark Raman probes. An RIE value of 170 was obtained which is one of the highest amongst previously reported monoyne and diyne-based Raman probes. The sensitive ABATaR -scaffold was developed into a dual turn-on and ratiometric Fe 2+ -sensor that was applied to distinctly quantify endogenous cellular labile Fe 2+ ion levels. In a key result, live-cell, temporal imaging with the Fe 2+ - ABATaR sensor revealed that intracellular labile Fe 2+ levels progressively increase with ferroptosis while the total Fe-level remains constant. To demonstrate the generalizability of the design workflow, we synthesized an orthogonal ABATaR -sensor for H 2 O 2 . The H 2 O 2 -sensor was applied together with the Fe 2+ -sensor along with inherent Raman peaks for cytochromes to enable simultaneous, multiplexed spontaneous Raman imaging of three distinct ferroptosis hallmarks—labile Fe 2+ , H 2 O 2 , and redox-sensitive cytochrome Raman signals—in living cells. Importantly, the ability to pre-design orthogonal ratiometric Raman sensors and simultaneously track three regulators of ferroptosis via discrete non-overlapping Raman peaks highlights the tremendous potential of Raman sensors toward attaining live cell multiplexed imaging and quantification.

  • Open Access

    Cellular Quiescence Involves Trigger-Specific Remodeling of Metal Homeostasis

    by Ananya Rakshit, Samuel E. Holtzen, Allegra Aron, Aidan T. Pezacki, Smitaroopa Kahali, Sujit K. Das, Lynn Sanford, Martina Ralle, Ankona Datta, Amy E. Palmer

    Cells continuously evaluate their nutrient status to make proliferation-quiescence decisions. Zinc is one such essential nutrient and zinc deprivation drives cells into quiescence. How other metal micronutrients are altered in quiescence has not been established. Here, we examined three quiescence triggers (zinc deficiency, serum starvation, and growth factor withdrawal) in MCF10A cells by modifying growth media, the primary source of metals. Fluorescence microscopy and elemental analysis reveal trigger-dependent changes in the labile and total transition metal pools of quiescent cells. RNA sequencing and differential expression analysis of metal associated, regulatory, and homeostasis genes shows that while core quiescence pathways are shared across triggers, quiescence states remain molecularly distinct. A significant percent of 2458 metal homeostasis genes are differentially expressed, including genes involved in antioxidant activity, oxidative phosphorylation, and heme metabolism. Overall, this work demonstrates that metal homeostasis is systematically rewired during cellular quiescence, with different signatures for different quiescence triggers.

  • Open Access

    Metal homeostasis is remodeled in response to different quiescence triggers

    by Ananya Rakshit, Samuel E Holtzen, Allegra T. Aron, Aidan T. Pezacki, Smitaroopa Kahali, Sujit K. Das, Lynn Sanford, Martina Ralle, Ankona Datta, Amy E Palmer

    Cells can enter a reversible non-proliferative state called quiescence either spontaneously or in response to nutrient deprivations. Metal ions are essential nutrients and play wide-ranging regulatory and signaling roles in biological processes. We previously showed that zinc is an essential nutrient for the mammalian cell cycle as zinc deprivation drives cells into quiescence, and this quiescent state is associated with changes in iron, copper, and manganese, suggesting broad remodeling of metal homeostasis. Here we examine whether metal remodeling is a general feature of quiescence by inducing quiescence via different triggers (zinc deficiency, serum starvation, and growth factor withdrawal) in MCF10A cells. Fluorescence microscopy and elemental analysis reveal significant trigger-dependent changes in the labile and total metal pools of quiescent cells. To gain insight into these differences, we carried out RNA sequencing and differential expression analysis, focusing on metal associated, metal regulatory, and metal homeostasis genes. While core quiescence pathways are shared across triggers, quiescence states remain molecularly distinct. A significant percent of 2458 metal homeostasis annotated genes are differentially expressed including 55% in starvation-induced quiescence, 50% in zinc deficiency-induced quiescence and 21% in growth factor withdrawal-induced quiescence. Our results also showed unique alteration of genes involved in major metal dependent processes including antioxidant activity, oxidative phosphorylation, heme metabolism, and chromatin accessibility in different quiescence states. Overall, this work demonstrates that metal homeostasis is systematically rewired during cellular quiescence with associated effects on genes that regulate critical biological processes. Significance Statement: Cells constantly evaluate their nutrient and energy status and integrate these signals into proliferation-quiescence decisions. Quiescence prevents cells from passing damage to daughter cells. Metals are essential micronutrients for biological processes. While limitation of zinc can drive cells into quiescence and alter other metals, how metals are remodeled and whether this is a common feature of quiescence was unknown. Here we examined three quiescence triggers by modifying growth media and serum, the primary source of metals. We report significant changes in labile and total Cu, Fe, Zn and Mn pools, and metal associated genes in response to distinct quiescence triggers. These changes converge on mitochondrial function, cellular antioxidant activity, and heme biosynthesis in a trigger specific manner.

  • Open Access

    A Miniature Peptide-based Ratiometric, Cell Permeable Sensor Images PI(3,5)P2 Lipid Pools in Organelle Membranes of Living Cells

    by Shamasoddin Shekh, Diya Elizabeth Prince, Smitaroopa Kahali, Ankona Datta

    Phosphatidylinositol 3,5-bisphosphate [PI(3,5)P2] is a low-abundance phosphoinositide, constituting ~0.05–0.1 mol % of total cellular phosphoinositides, yet plays crucial roles in innate immunity, endolysosomal trafficking, autophagy, and ion channel regulation. Owing to its transient occurrence, fast metabolic turnover, and presence in membranes of acidic intracellular compartments, selective and rapid visualization of PI(3,5)P2 pools in living cells has remained a challenge. Here, we report DAN–TRPML1-PEP , a cell-permeable, peptide-based, ratiometric fluorescent sensor for PI(3,5)P2. The sensor comprises of a 20-amino acid polybasic segment from the N-terminal domain of TRPML1 channel, a native PI(3,5)P2-binding protein. The peptide has been conjugated to a polarity-sensitive dye, 6-dimethylamino-2-acetylnaphthalene (DAN), to afford the sensor. DAN–TRPML1-PEP exhibits a selective ratiometric fluorescence response upon PI(3,5)P2 binding. Importantly, the sensor not only selectively detects PI(3,5)P2 over other physiologically relevant phospholipids but can also distinguish PI(3,5)P2 from closely related phosphoinositides, including PI(3)P and PI(5)P. DAN–TRPML1-PEP rapidly and directly enters living cells and selectively images PI(3,5)P2 within late endosomes, lysosomes, autophagosomes, and endocytic vesicles. The sensor could also be applied for wash-free live-cell imaging of PI(3,5)P2. Hence, DAN–TRPML1-PEP successfully reveals PI(3,5)P2 localization in living cells bringing in a much-required chemical tool for interrogating this key signaling lipid.

  • Open Access

    Determining live-cell integrity of metallodrugs using reversible fluorescent metal ion sensors: intrinsic inertness matters for stability in cells

    by Kunika Gupta, Jean Bouvet, Didine Biatuma, Namita Raju John, Sujit Kumar Das, Avishek Jana, Nicolas Delsuc, Andrea Somogyi, Kadda Medjoubi, Philippe Seksik, et al.

    The therapeutic effectiveness of metallodrugs is heavily influenced by their propensity to release metal ions within biological systems. This is particularly relevant in the case of labile first series transition metal ions, the release leading to loss in complex-based activity. While thermodynamic parameters governing the stability and efficacy of metallodrugs can be analyzed using established analytical techniques, assessing live-cell integrity of a metallodrug remains a significant challenge. Determination of in-cell integrity is essential for optimizing the design and therapeutic potential of metallodrugs. Importantly, the study should be performed in living cells because biological environments can significantly impact the stability and lability. Currently, no experimental approach directly visualizes metal ions released by metallodrugs and determines their in-cell-integrity. To address this gap, we propose a novel assay to monitor the extent of release of metal ions from metallodrugs using binding-based, reversible fluorescent metal ion sensors in live cells. We tested the relevance of the assay on a series of manganese antioxidants (Mn superoxide dismutase (SOD) mimics) utilizing Mn(II) selective reversible fluorescent sensors. The results showed that the SOD mimic Mn1 , with the lowest intrinsic K d from the series of antioxidants tested, exhibited the highest amount of Mn-release, while Mn1CP , with the highest K d , demonstrated lower Mn-release. Interestingly, the level of metal-release correlates with the intrinsic lability of metallodrugs and not with their intrinsic thermodynamic stability. The study demonstrates the importance of assessing in-cell metal ion release for optimizing the therapeutic outcome of metallodrugs. The novel fluorescence assay developed here offers a valuable tool for the evaluation of metallodrug behavior in cellular environments. Overall, this work shows that in-cell metal ion release from these manganese metallodrugs appears to correlate with intrinsic lability and thus is under kinetic control.

  • Open Access

    Morphable ‘Stitched’ Sensors for Simultaneous Spatiotemporal Tracking of Correlated Bioanalytes in Living Cells

    by Smitaroopa Kahali, Manisha Bose, Sujit Kumar Das, Ankona Datta

    Correlated changes in molecular levels and distributions are associated with all life processes and importantly regulate key decision-making events in biology. Spatiotemporal dynamics of biomolecules are essential for functions like cell signaling, transport, immunity, and recycling, and are either affected by or cause diseases such as cancers, inflammation, and neurodegeneration. In this backdrop, the ability to catch molecules of life in action using optical imaging is extremely powerful. Simultaneous tracking of biologically correlated analytes in living cells necessitates cell-permeable, multianalyte sensors. Key criteria for achieving simultaneous, correlated tracking of multiple analytes are that sensors for these analytes should enter cells at the same time and concomitantly reach the same location where we want to detect the analytes. Separate sensors, either small-molecule- or macromolecule-based, cannot fulfill these requirements directly. We introduce morphable ‘stitched’ sensors, where fluorescent sensors for single analytes can be strategically joined via native chemical ligation (NCL) on a made-to-order basis. Morphable ‘stitched’ sensors are built from a library of single-analyte sensing units conjugated to short peptide scaffolds. The use of peptide-based scaffolds in combination with NCL allows generation of modular, biocompatible, water-soluble, and importantly cell-permeable multianalyte sensors tailored to address specific biological questions. We report five proof-of-concept multianalyte sensors created from a common single-analyte sensor library using this ‘stitching’ strategy. ‘Stitched’ sensors enable simultaneous imaging and temporal tracking of bioanalytes via time-lapse imaging. In our pilot studies we image different combinations of analytes including protons, hydrogen peroxide, and enzyme activity, in live cells, affording insights into pH- and hydrogen peroxide-dependent enzyme activity. Cellular uptake studies show that the analyte-sensing modules in ‘stitched’ sensors enter cells simultaneously and as rapidly as 5 min, exhibit synchronized uptake dynamics, and are internalized in equal proportions, resulting in a uniform distribution across the cell population. Our novel morphable ‘stitching’ platform therefore offers a universal approach toward live-cell multianalyte imaging.


  • Reaction‐Based Ratiometric Sensors for Simultaneous Multi‐Bio‐Analyte Imaging in Living Cells Using Spontaneous Raman Scattering

    by Sujit K Das, Heqi Xi, Itsuki Yamamoto, Katsumasa Fujita, Ankona Datta

    Raman‐scattering comes with the promise of multi‐bio‐analyte imaging because of narrow peak‐widths. This feature combined with alkyne/nitrile tags accessing the cell‐silent region, have catalyzed the development of Raman‐probes. In this backdrop, Raman‐responsive ratiometric sensors will be key players for imaging bio‐analytes. A major challenge, however, is low Raman‐scattering cross‐sections of alkynes/nitriles, leading to probes with low sensitivity and reliance on stimulated Raman which is not widely accessible. Raman‐responsive ratiometric sensors for the accessible spontaneous Raman imaging platform still remain elusive. We have leveraged the “push–pull” effect to achieve novel activity‐based alkyne‐tag Raman sensors ( ABATaR s) with high sensitivity. ABATaR s show high computed Raman‐scattering activities 12–38 times that of benchmark 5‐Ethynyl‐2′‐deoxyuridine ( EdU ), significantly high experimental Raman intensity versus EdU between 5 and 22, and relative Raman scattering cross‐sections for the alkyne stretching with respect to dimethyl‐sulfoxide C‐H stretching as high as 466. To demonstrate generality, cell‐permeable, ratiometric ABATaR s for pH, hydrogen peroxide, and Cu ions were developed. ABATaR s can image physiological and pathophysiological levels of bio‐analytes in live‐cells at as low as 1–5 µM sensor concentrations on a spontaneous Raman microscope and distinctly enhance spontaneous Raman imaging‐speed. In a key advance, we demonstrate simultaneous multi‐analyte Raman‐imaging of bio‐correlated Cu ions and hydrogen peroxide in live‐cells.

  • Reaction‐Based Ratiometric Sensors for Simultaneous Multi‐Bio‐Analyte Imaging in Living Cells Using Spontaneous Raman Scattering

    by Sujit K Das, Heqi Xi, Itsuki Yamamoto, Katsumasa Fujita, Ankona Datta

    Raman‐scattering comes with the promise of multi‐bio‐analyte imaging because of narrow peak‐widths. This feature combined with alkyne/nitrile tags accessing the cell‐silent region, have catalyzed the development of Raman‐probes. In this backdrop, Raman‐responsive ratiometric sensors will be key players for imaging bio‐analytes. A major challenge, however, is low Raman‐scattering cross‐sections of alkynes/nitriles, leading to probes with low sensitivity and reliance on stimulated Raman which is not widely accessible. Raman‐responsive ratiometric sensors for the accessible spontaneous Raman imaging platform still remain elusive. We have leveraged the “push–pull” effect to achieve novel activity‐based alkyne‐tag Raman sensors ( ABATaR s) with high sensitivity. ABATaR s show high computed Raman‐scattering activities 12–38 times that of benchmark 5‐Ethynyl‐2′‐deoxyuridine ( EdU ), significantly high experimental Raman intensity versus EdU between 5 and 22, and relative Raman scattering cross‐sections for the alkyne stretching with respect to dimethyl‐sulfoxide C‐H stretching as high as 466. To demonstrate generality, cell‐permeable, ratiometric ABATaR s for pH, hydrogen peroxide, and Cu ions were developed. ABATaR s can image physiological and pathophysiological levels of bio‐analytes in live‐cells at as low as 1–5 µM sensor concentrations on a spontaneous Raman microscope and distinctly enhance spontaneous Raman imaging‐speed. In a key advance, we demonstrate simultaneous multi‐analyte Raman‐imaging of bio‐correlated Cu ions and hydrogen peroxide in live‐cells.


  • Open Access

    Reaction-based Ratiometric Sensors for Simultaneous Multi-Bio-Analyte Imaging in Living Cells Using Spontaneous Raman Scattering

    by Sujit Kumar Das, Heqi Xi, Itsuki Yamamoto, Katsumasa Fujita, Ankona Datta

    Raman scattering comes with the promise of live-cell multi-bio-analyte imaging because of narrow peak-widths. This feature combined with the strategy of utilizing alkyne/nitrile tags with peaks in the cell-silent region, have catalyzed the development of Raman probes. In this context, Raman-responsive ratiometric sensors will be key players for imaging bio-analytes in living cells. However, a major challenge is low Raman scattering cross-sections of alkynes/nitriles, leading to either probes with low sensitivity or reliance on stimulated Raman which is not widely-accessible. Raman-responsive ratiometric sensors functioning in the accessible Raman scattering-imaging platform remain elusive. We have leveraged the ‘push-pull’ effect to achieve a series of mono-alkyne-sensors that have computed Raman-scattering activities 12-34 times that of the benchmark 5-Ethynyl-2′-deoxyuridine (EdU) and significantly high experimental Raman intensity versus EdU between 5-22. The sensors afford relative Raman scattering cross-sections for the alkyne stretching with respect to dimethyl-sulfoxide C-H stretching as high as 466. Herein we report, Activity-based Alkyne tag Raman (ABATaR) sensors that undergo bio-analyte specific reactions giving distinct 9-18 cm-1 shifts in alkyne-peaks from before to after reaction. We demonstrate the generality of our novel ABATaR strategy by developing cell-permeable, sensitive, ratiometric Raman sensors for pH, hydrogen peroxide, and Cu ions. The ABATaR sensors can image physiological and pathophysiological levels of bio-analytes in living cells at as low as 1-5 µM sensor concentrations on a spontaneous Raman microscopy setup and distinctly enhance spontaneous Raman imaging speed. In a key advance, we demonstrate simultaneous multi-analyte imaging of Cu ions and hydrogen peroxide in living cells.