Mohamad Hamady
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mohamad Hamady has a total of 160 co-authors. Here are the top co-authors by number of shared publications:
- Celia V. Riga
Regional Vascular Unit, St Mary's Hospital, London, U.K.
6 shared publications - Robert Morgan
Department of Vascular and Interventional Radiology, St George’s University Hospitals NHS Foundation Trust, London, UK
6 shared publications Colin Bicknell
Department of Vascular Surgery, Imperial College Healthcare NHS Trust, London, UK
5 shared publications- Colin Bicknell
Department of Surgery and Cancer, Imperial College London, London, UK
5 shared publications - Xiao Yun Xu
Department of Chemical Engineering, Imperial College London, South Kensington Campus, London, United Kingdom
5 shared publications Celia Riga
Department of Vascular Surgery, Imperial College Healthcare NHS Trust, London, UK
4 shared publications
Latest Publications
- Open Access
- 29 September 2026
- Published by Springer Nature in CardioVascular and Interventional Radiology
- p. 1-21
CIRSE Standards of Practice for the Endovascular Management of Acute Lower Limb Ischaemia
Background: Acute lower limb ischaemia is a medical emergency that requires immediate diagnosis and management to avoid catastrophic consequences. As an alternative to open surgical procedures, endovascular intervention is a minimally invasive approach that can be effective in appropriately selected patients, with outcomes comparable to open surgery in contemporary series. The ongoing improvement and expansion of techniques and tools continue to refine clinical outcomes. Purpose: CIRSE Standards of Practice documents recommend a reasonable approach to, and best practices for, performing procedures, in this case, endovascular procedures to restore flow in acute lower limb ischaemia. Methods: The writing group, established by the CIRSE Standards of Practice Committee on the recommendation of the Endovascular Subcommittee of CIRSE, consisted of five clinicians with internationally recognised expertise in acute lower limb ischaemia and one research assistant. The writing group reviewed the existing literature and conducted a pragmatic evidence search utilising PubMed to identify publications in English pertaining to human subjects from 2013 to 2025. The final recommendations were developed through consensus, incorporating relevant and valid older primary sources, including the 2011 CIRSE Standards of Practice document. Results: Endovascular techniques are established in the treatment of acute lower limb ischaemia and are associated with high technical success rates, which correlate with improved clinical outcomes. Regular follow-up surveillance is recommended to achieve good long-term results.
- 29 September 2026
- Published by Springer Nature in CardioVascular and Interventional Radiology
- p. 1-21
Open AccessCIRSE Standards of Practice for the Endovascular Management of Acute Lower Limb Ischaemia
Background: Acute lower limb ischaemia is a medical emergency that requires immediate diagnosis and management to avoid catastrophic consequences. As an alternative to open surgical procedures, endovascular intervention is a minimally invasive approach that can be effective in appropriately selected patients, with outcomes comparable to open surgery in contemporary series. The ongoing improvement and expansion of techniques and tools continue to refine clinical outcomes. Purpose: CIRSE Standards of Practice documents recommend a reasonable approach to, and best practices for, performing procedures, in this case, endovascular procedures to restore flow in acute lower limb ischaemia. Methods: The writing group, established by the CIRSE Standards of Practice Committee on the recommendation of the Endovascular Subcommittee of CIRSE, consisted of five clinicians with internationally recognised expertise in acute lower limb ischaemia and one research assistant. The writing group reviewed the existing literature and conducted a pragmatic evidence search utilising PubMed to identify publications in English pertaining to human subjects from 2013 to 2025. The final recommendations were developed through consensus, incorporating relevant and valid older primary sources, including the 2011 CIRSE Standards of Practice document. Results: Endovascular techniques are established in the treatment of acute lower limb ischaemia and are associated with high technical success rates, which correlate with improved clinical outcomes. Regular follow-up surveillance is recommended to achieve good long-term results.
- 26 September 2026
- Published by Elsevier in Clinical Radiology
- Vol. 103
Current practices in elective embolisation: insights from a UK national cross-sectional survey
- 26 September 2026
- Published by Elsevier in Clinical Radiology
- Vol. 103
Current practices in elective embolisation: insights from a UK national cross-sectional survey
- Open Access
- 27 May 2026
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 49 (8) , 1488-1497
Quantitative Assessment of Aortic Arch Conformability and Clinical Outcomes Following Thoracic Endovascular Aortic Repair
Purpose: Thoracic stent graft conformability is believed to provide mechanical advantages during thoracic endovascular aortic repair (TEVAR); however, quantitative evidence and associated clinical outcomes remain limited. This study aimed to assess stent graft conformability across varying aortic arch configurations and pathologies, and to evaluate short- and mid-term technical and clinical outcomes. Materials and Methods: A retrospective, single-centre review was conducted of TEVAR procedures performed using the GORE cTAG stent graft over a seven-year period. Pre- and post-deployment anatomical measurements were obtained using Endosize® software to assess conformability across a range of aortic arch morphologies and aortic syndromes. Conformability was defined as a < 10% change in predefined anatomical parameters, including aortic arch angle and proximal landing zone (PLZ) angle. Demographic data, mortality, complications, incidence of bird beaking, and reintervention rates were analysed. Results: Of 189 TEVAR procedures performed during the study period, 111 met inclusion criteria and utilised the GORE cTAG stent graft. High conformability was observed following intervention, with 79% of patients demonstrating < 10% change in aortic arch angle and 88% demonstrating < 10% change in PLZ angle. Bird beaking occurred in 10.8% of patients. The overall reintervention rate was 5.4%, with greater angular changes significantly associated with reintervention ( p = 0.039). Overall survival rates at 30 days, 1 year, and 5 years were 95%, 86%, and 80%, respectively. Conclusion: The GORE cTAG stent graft demonstrates high conformability across diverse aortic arch morphologies and pathologies, which is associated with favourable short- and mid-term technical and clinical outcomes.
- 27 May 2026
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 49 (8) , 1488-1497
Open AccessQuantitative Assessment of Aortic Arch Conformability and Clinical Outcomes Following Thoracic Endovascular Aortic Repair
Purpose: Thoracic stent graft conformability is believed to provide mechanical advantages during thoracic endovascular aortic repair (TEVAR); however, quantitative evidence and associated clinical outcomes remain limited. This study aimed to assess stent graft conformability across varying aortic arch configurations and pathologies, and to evaluate short- and mid-term technical and clinical outcomes. Materials and Methods: A retrospective, single-centre review was conducted of TEVAR procedures performed using the GORE cTAG stent graft over a seven-year period. Pre- and post-deployment anatomical measurements were obtained using Endosize® software to assess conformability across a range of aortic arch morphologies and aortic syndromes. Conformability was defined as a < 10% change in predefined anatomical parameters, including aortic arch angle and proximal landing zone (PLZ) angle. Demographic data, mortality, complications, incidence of bird beaking, and reintervention rates were analysed. Results: Of 189 TEVAR procedures performed during the study period, 111 met inclusion criteria and utilised the GORE cTAG stent graft. High conformability was observed following intervention, with 79% of patients demonstrating < 10% change in aortic arch angle and 88% demonstrating < 10% change in PLZ angle. Bird beaking occurred in 10.8% of patients. The overall reintervention rate was 5.4%, with greater angular changes significantly associated with reintervention ( p = 0.039). Overall survival rates at 30 days, 1 year, and 5 years were 95%, 86%, and 80%, respectively. Conclusion: The GORE cTAG stent graft demonstrates high conformability across diverse aortic arch morphologies and pathologies, which is associated with favourable short- and mid-term technical and clinical outcomes.
- Open Access
- 19 November 2025
- Published by SAGE Publications in Vascular and Endovascular Surgery
- Vol. 60 (3) , 271-282
The Use of Pressure Indices, Such as Fractional Flow Reserve, in Peripheral Arterial Disease-A Review of Current Literature and Potential Prospects
Purpose: To assess the evidence in the current literature, identify the knowledge gaps and propose future standards for the use of pressure indices in peripheral arterial disease (PAD). Methods: A search of all medical databases was performed to identify studies performed between 01/01/2000 and 31/12/2024, looking at the use of FFR or IFR in the management of PAD. The Newcastle-Ottawa scale was used to assess the quality of the papers. A comparison of the studies was performed using various parameters including; study design, cohort demographics, aim, lesions treated, hyperaemic agent used/pressure indices utilised, FFR endpoint and clinical outcomes. Results: 136 studies were found in initial search. Only studies investigating FFR were identified, none looked at IFR. Following the application of the exclusion criteria, 8 relevant studies with a total of 247 patients were included in the final analyses. No randomised controlled or prospective trials were found. Significant heterogeneity was observed in the methodology and data collection among the included papers. Despite this, the analysis demonstrated initial evidence showing the potential of pressure measurements to revolutionise diagnostic, intra-procedural and prognostic decisions in PAD, akin to the data that already exists in coronary artery disease. Conclusions: Further standardised research of FFR is needed in peripheral vascular disease to improve objective understanding of physiological parameters pre and post-treatment. To this end, a standardisation tool has been proposed to homogenise and aid future research in drawing more robust conclusions for the use of pressure indices in PAD.
- 19 November 2025
- Published by SAGE Publications in Vascular and Endovascular Surgery
- Vol. 60 (3) , 271-282
Open AccessThe Use of Pressure Indices, Such as Fractional Flow Reserve, in Peripheral Arterial Disease-A Review of Current Literature and Potential Prospects
Purpose: To assess the evidence in the current literature, identify the knowledge gaps and propose future standards for the use of pressure indices in peripheral arterial disease (PAD). Methods: A search of all medical databases was performed to identify studies performed between 01/01/2000 and 31/12/2024, looking at the use of FFR or IFR in the management of PAD. The Newcastle-Ottawa scale was used to assess the quality of the papers. A comparison of the studies was performed using various parameters including; study design, cohort demographics, aim, lesions treated, hyperaemic agent used/pressure indices utilised, FFR endpoint and clinical outcomes. Results: 136 studies were found in initial search. Only studies investigating FFR were identified, none looked at IFR. Following the application of the exclusion criteria, 8 relevant studies with a total of 247 patients were included in the final analyses. No randomised controlled or prospective trials were found. Significant heterogeneity was observed in the methodology and data collection among the included papers. Despite this, the analysis demonstrated initial evidence showing the potential of pressure measurements to revolutionise diagnostic, intra-procedural and prognostic decisions in PAD, akin to the data that already exists in coronary artery disease. Conclusions: Further standardised research of FFR is needed in peripheral vascular disease to improve objective understanding of physiological parameters pre and post-treatment. To this end, a standardisation tool has been proposed to homogenise and aid future research in drawing more robust conclusions for the use of pressure indices in PAD.
- Open Access
- 16 October 2025
- Published by Springer Nature in CVIR Endovascular
- Vol. 8 (1) , 1-11
Computed tomography assessment of the gastric arterial anatomy for embolisation treatment of obesity
Background: Obesity is a global pandemic affecting more than 1 billion people worldwide and a leading cause of preventable death. Left gastric artery embolisation to inhibit ghrelin secretion, a hormonal driver of appetite, has been proposed as a potentially safer treatment for obesity than surgery. This study describes the incidence of anatomical variation, gastric artery anastomoses, collateral supply and vessel lengths, diameters and angles of origin relevant to embolisation of the LGA in the EMBIO cohort of obese patients. Results: Arterial phase CT scans (n = 90) were performed as part of screening for the EMBIO trial. 62 participants (69%) had conventional coeliac and hepatic artery anatomy. 14 participants (16%) had left hepatic arterial supply originating from the LGA. The most common LGA branching pattern (37%) was for the first branch to supply the cardia / gastro-oesophageal junction and then for the LGA to split into two main branches supplying the gastric fundus. 34% had a left- right gastric artery anastomosis visible on CT. The LGA was the dominant artery supplying the gastric fundus in 51% with supply from multiple arteries, most frequently the LGA and short gastric arteries (27%), seen in the other participants. Conclusion: This study presents detailed analysis of the arterial anatomy relevant to performing successful and safe embolisation of the LGA for treatment of obesity and acute haemorrhage. Graphical
- 16 October 2025
- Published by Springer Nature in CVIR Endovascular
- Vol. 8 (1) , 1-11
Open AccessComputed tomography assessment of the gastric arterial anatomy for embolisation treatment of obesity
Background: Obesity is a global pandemic affecting more than 1 billion people worldwide and a leading cause of preventable death. Left gastric artery embolisation to inhibit ghrelin secretion, a hormonal driver of appetite, has been proposed as a potentially safer treatment for obesity than surgery. This study describes the incidence of anatomical variation, gastric artery anastomoses, collateral supply and vessel lengths, diameters and angles of origin relevant to embolisation of the LGA in the EMBIO cohort of obese patients. Results: Arterial phase CT scans (n = 90) were performed as part of screening for the EMBIO trial. 62 participants (69%) had conventional coeliac and hepatic artery anatomy. 14 participants (16%) had left hepatic arterial supply originating from the LGA. The most common LGA branching pattern (37%) was for the first branch to supply the cardia / gastro-oesophageal junction and then for the LGA to split into two main branches supplying the gastric fundus. 34% had a left- right gastric artery anastomosis visible on CT. The LGA was the dominant artery supplying the gastric fundus in 51% with supply from multiple arteries, most frequently the LGA and short gastric arteries (27%), seen in the other participants. Conclusion: This study presents detailed analysis of the arterial anatomy relevant to performing successful and safe embolisation of the LGA for treatment of obesity and acute haemorrhage. Graphical
- Open Access
- 15 October 2025
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 48 (12) , 1837-1839
CIRSE Position Statement on Endovascular Aortic Repair
- 15 October 2025
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 48 (12) , 1837-1839
Open AccessCIRSE Position Statement on Endovascular Aortic Repair
- Open Access
- 15 October 2025
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 48 (12) , 1887-1893
The Contemporary Role of Interventional Radiologists in Endovascular Aortic Repair: A Survey of CIRSE Members
Purpose: To describe the outcomes of a survey conducted among CIRSE members on endovascular aortic repair and to outline the future practice and needs of CIRSE members in this area. Materials and methods: An anonymous online survey with 21 questions was designed by the authors and sent to CIRSE members worldwide; data were collected for 12 weeks. Results: The survey collected 326 complete responses, with most respondents practicing in Europe. Two-thirds of respondents indicated that aortic repair is performed by multidisciplinary teams including IRs, with more than half reporting that they are equal partners in performing the procedure, and 27% acting as primary operators. In their practice, the most frequently performed endovascular aortic procedures were EVAR and embolisation of endoleaks, followed by FEVAR and TEVAR. A majority of 64% of respondents predict a growth in their endovascular aortic practice in the next 5 to 10 years that could further be supported by training, an increase in the workforce, societal guidelines, and additional qualifications. Hindrances for growth include turf competition as well as hospital management decisions. Conclusion: The survey indicates that Interventional Radiologists continue to play a significant role in endovascular aortic procedures and identifies challenges and opportunities to further increase the role of IR in endovascular aortic aneurysm procedures for the benefit of patients. The authors consider it essential for national societies as well as CIRSE to facilitate and encourage the clinical role of IRs in standard and complex EVAR to best guide future developments for optimal patient management in aortic disease.
- 15 October 2025
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 48 (12) , 1887-1893
Open AccessThe Contemporary Role of Interventional Radiologists in Endovascular Aortic Repair: A Survey of CIRSE Members
Purpose: To describe the outcomes of a survey conducted among CIRSE members on endovascular aortic repair and to outline the future practice and needs of CIRSE members in this area. Materials and methods: An anonymous online survey with 21 questions was designed by the authors and sent to CIRSE members worldwide; data were collected for 12 weeks. Results: The survey collected 326 complete responses, with most respondents practicing in Europe. Two-thirds of respondents indicated that aortic repair is performed by multidisciplinary teams including IRs, with more than half reporting that they are equal partners in performing the procedure, and 27% acting as primary operators. In their practice, the most frequently performed endovascular aortic procedures were EVAR and embolisation of endoleaks, followed by FEVAR and TEVAR. A majority of 64% of respondents predict a growth in their endovascular aortic practice in the next 5 to 10 years that could further be supported by training, an increase in the workforce, societal guidelines, and additional qualifications. Hindrances for growth include turf competition as well as hospital management decisions. Conclusion: The survey indicates that Interventional Radiologists continue to play a significant role in endovascular aortic procedures and identifies challenges and opportunities to further increase the role of IR in endovascular aortic aneurysm procedures for the benefit of patients. The authors consider it essential for national societies as well as CIRSE to facilitate and encourage the clinical role of IRs in standard and complex EVAR to best guide future developments for optimal patient management in aortic disease.
- RetractedOpen Access
- 18 September 2025
- Published by Elsevier in Clinical Radiology
- Vol. 91, 107094
Interventional radiology in the United Kingdom - A long-term strategic plan
- 18 September 2025
- Published by Elsevier in Clinical Radiology
- Vol. 91, 107094
RetractedOpen AccessInterventional radiology in the United Kingdom - A long-term strategic plan
- Open Access
- 28 May 2025
- Published by Springer Nature in CVIR Endovascular
- Vol. 8 (1) , 1-13
Is uterine artery embolisation a safe and effective modality to treat submucosal fibroids?
Highlights: • Uterine fibroid embolization (UFE) reduced the median volume of dominant submucosal leiomyomas by 64% and achieved over 90% devascularization in 94.8% of cases. • High patient satisfaction was observed, with 84.5% of patients successfully discharged without needing further intervention. • Severe adverse events were rare, affecting only 3.2% of patients, with pelvic infections being the most significant. • Mild adverse events occurred in 16.8% of patients, including infections requiring antibiotics and persistent vaginal discharge. • A multidisciplinary approach is essential for managing patients with submucosal leiomyomas undergoing UFE to ensure optimal treatment outcomes.
- 28 May 2025
- Published by Springer Nature in CVIR Endovascular
- Vol. 8 (1) , 1-13
Open AccessIs uterine artery embolisation a safe and effective modality to treat submucosal fibroids?
Highlights: • Uterine fibroid embolization (UFE) reduced the median volume of dominant submucosal leiomyomas by 64% and achieved over 90% devascularization in 94.8% of cases. • High patient satisfaction was observed, with 84.5% of patients successfully discharged without needing further intervention. • Severe adverse events were rare, affecting only 3.2% of patients, with pelvic infections being the most significant. • Mild adverse events occurred in 16.8% of patients, including infections requiring antibiotics and persistent vaginal discharge. • A multidisciplinary approach is essential for managing patients with submucosal leiomyomas undergoing UFE to ensure optimal treatment outcomes.
- Open Access
- 13 March 2025
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 48 (6) , 851-856
The Central Role of the Interventional Radiologist in Advanced Therapies for Pulmonary Embolism: Results from An Online Member Survey by the Cardiovascular and Interventional Radiological Society of Europe
Purpose: To describe the outcomes of a survey on the provision of interventional radiology procedures for the treatment of acute pulmonary embolism (PE) in Europe and beyond. Methods: An online survey with 14 structured items was designed by the authors and was sent to 7116 CIRSE members via email. The anonymous online survey collected data for eight weeks; only complete responses were statistically analysed. Results: The survey was completed by 373 members (5.24%). Among these, 75.1% worked at centres offering catheter-directed thrombolysis or thrombectomy, in which 89.3% (250) personally perform endovascular treatment techniques for pulmonary embolism and the IR department is primarily responsible for the endovascular treatment techniques of PE in 83.2% of cases. The most frequently used endovascular techniques were (large bore) aspiration thrombectomy (85%) and catheter-directed thrombolysis (58.9%). The most common indications for intervention were sub-massive and massive PE (69.9%) and massive PE only (28%). In 70% of centres offering catheter-directed thrombolysis or thrombectomy, three or more Interventional Radiologists (IRs) are involved in PE treatment. Multidisciplinary rapid response teams for PE were available in 40.8% of centres, and included IRs in 91.4%. Conclusion: IRs are heavily involved in the management of patients with massive and sub-massive pulmonary embolism; further research is mandated to address clinical questions including patient selection and the timing for transcatheter therapies of PE provided by IR. Graphical
- 13 March 2025
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 48 (6) , 851-856
Open AccessThe Central Role of the Interventional Radiologist in Advanced Therapies for Pulmonary Embolism: Results from An Online Member Survey by the Cardiovascular and Interventional Radiological Society of Europe
Purpose: To describe the outcomes of a survey on the provision of interventional radiology procedures for the treatment of acute pulmonary embolism (PE) in Europe and beyond. Methods: An online survey with 14 structured items was designed by the authors and was sent to 7116 CIRSE members via email. The anonymous online survey collected data for eight weeks; only complete responses were statistically analysed. Results: The survey was completed by 373 members (5.24%). Among these, 75.1% worked at centres offering catheter-directed thrombolysis or thrombectomy, in which 89.3% (250) personally perform endovascular treatment techniques for pulmonary embolism and the IR department is primarily responsible for the endovascular treatment techniques of PE in 83.2% of cases. The most frequently used endovascular techniques were (large bore) aspiration thrombectomy (85%) and catheter-directed thrombolysis (58.9%). The most common indications for intervention were sub-massive and massive PE (69.9%) and massive PE only (28%). In 70% of centres offering catheter-directed thrombolysis or thrombectomy, three or more Interventional Radiologists (IRs) are involved in PE treatment. Multidisciplinary rapid response teams for PE were available in 40.8% of centres, and included IRs in 91.4%. Conclusion: IRs are heavily involved in the management of patients with massive and sub-massive pulmonary embolism; further research is mandated to address clinical questions including patient selection and the timing for transcatheter therapies of PE provided by IR. Graphical