FLFernanda Cordoba Lanza

Fernanda Cordoba Lanza

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Fernanda Cordoba Lanza has a total of 252 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Test‐Retest Reliability, Learning Effect and Measurement Error of the Modified Shuttle Test (MST) in Children With Asthma: A Multicenter Study

    by Lara Bezerra Radis, Vitória Cavalheiro Puzzi, Thaila Corsi Dias, Natielly Soares Correia, Jéssica Lane Felippe Montes, Mariana Mazzuca Reimberg, Fernanda Cordoba Lanza, Evelim Leal de Freitas Dantas Gomes, Cláudio Luiz Castro Gomes de Amorim, Karina Couto Furlanetto

    Objective: To investigate test‐retest reliability, measurement error (standard error of measurement [SEM] and minimum detectable difference [MDD]), and the learning effect of the Modified Shuttle Test (MST) in children with asthma. Methods: Multicenter cross‐sectional study including clinically stable children aged 6–12 years with asthma. Lung function and exercise capacity were assessed using MST. Intraclass Correlation Coefficient (ICC) was calculated to assess test‐retest reliability. The first and second tests were compared using the paired Student's t‐ test to assess differences between tests. SEM and MDD were calculated to quantify measurement error. Results: One hundred and twenty three children were included (71 boys [57%]; median age 9 [7–10] years). The mean distance covered in the best MST was 611 ± 214 meters (confidence interval [95% CI] = 573–649meters). The MST showed an excellent test‐retest reliability (ICC = 0.96; 95% CI: 0.95–0.97). Distance was significantly lower in the second test than in the first (574 ± 218 vs. 601 ± 216 m; p = 0.0001). Learning effect was −27 ± 79 (4% ± 14%), the SEM was 56 meters (9.5%), and the MDD was 156 m (26.6%). Conclusion: The MST demonstrated excellent test–retest reliability and acceptable measurement error for assessing exercise capacity in children with asthma. Although a systematic difference was observed between tests, there was no evidence of a consistent learning effect, with individual variability in repeated performance.

  • ASSOBRAFIR clinical practice guidelines in intensive care physical therapy: Rehabilitation strategies in critically ill adults

    by Saint-Clair Gomes Bernardes Neto, Bruno Prata Martinez, Adriana Claudia Lunardi, Alexandre Simões Dias, Alexia Gabriela da Silva Vieira, Amanda Moreira Ferreira, Ana Carolina Pereira Nunes Pinto, André Luiz Lisboa Cordeiro, Ariany Marques Vieira, Bruno Leonardo da Silva Guimarães, et al.

  • Predictive factors for successful extubation in preterm infants: Relationship with weight, PaCO 2 and heart rate

    by Thalita Vilaboim Santos, Ednaldo D’ANgelis Chaves, Marcos Giovanni Santos Carvalho, Simone Nascimento Santos Ribeiro, Fernanda de Cordoba Lanza

    Objective: To identify variables associated with extubation success in preterm infants undergoing first elective extubation and to determine cutoff values to support clinical decision-making. Methods: This retrospective cohort study included preterm infants (gestational age ≤36 weeks and 6 days) admitted to a neonatal intensive care unit who underwent first elective extubation after orotracheal intubation. Extubation failure was defined as reintubation within 48 h. Bivariate and multivariate analyses were performed. Discriminant analysis defined cutoff values, and bootstrapping (500 replicates) supported comparisons. Results: Among 218 eligible infants, 73.9% achieved extubation success. In multivariate analysis, weight at extubation (OR 1.02; 95% CI 1.01–1.04), PaCO 2 (OR 0.93; 95% CI 0.89–0.98), and heart rate (OR 0.97; 95% CI 0.94–0.99) were independently associated with success. Cutoff values were 34.7 mmHg for PaCO 2 and 156 bpm for heart rate, both with modest sensitivity and specificity. Conclusions: Weight at extubation, PaCO 2 , and heart rate were independently associated with extubation success. Although their discriminatory performance was modest, these variables may provide clinically relevant information when interpreted within the context of early extubation. Their integration into a multidimensional assessment may support more individualized decision-making.

  • Open Access

    Ultrasound assessment of diaphragmatic function during weaning and after extubation in preterm newborns: brief report

    by Marcos Giovanni Santos Carvalho, Juliana Nasu Tomiyama, Marcelo Azeredo Terra, Fernanda Cordoba Lanza

    To describe and assess diaphragmatic function by ultrasound during the weaning and post-extubation phases in preterm newborns. This cross-sectional study included intubated preterm newborns eligible for extubation. Inspiratory diaphragmatic thickness (IDT), expiratory diaphragmatic thickness (EDT), diaphragmatic thickening fraction (DTF), and diaphragmatic excursion (DE) were evaluated at three time points: T1—during invasive mechanical ventilation (IMV); T2—during the spontaneous breathing trial (SBT); and T3—during nasal intermittent positive pressure ventilation (NIPPV). Friedman test and Wilcoxon signed-rank post hoc test were used for comparisons ( p < 0.05). Fifty preterm newborns were evaluated. Forty-five (mean gestational age 30.9 ± 2.2 weeks; mean weight 1377.5 ± 432 g) received IMV for 4 ± 3 days and were successfully extubated (extubation failure rate 10%). Due to the small number of failures ( n = 5), only descriptive analyses were performed. In successfully extubated newborns, IDT and DE increased at T2 and T3 compared to T1 ( p < 0.05), with IDT highest at T2. No significant changes were observed in EDT or DTF, which remained consistently elevated. Conclusion : In preterm newborns successfully extubated, diaphragmatic thickness and excursion increased during the SBT and remained elevated after extubation. These findings may support the use of diaphragmatic ultrasound to guide extubation readiness and monitor post-extubation adaptation in preterm infants. What is Known: • Extubation decisions in preterm infants rely mainly on clinical judgment .• Diaphragmatic ultrasound is used to assess diaphragmatic function in various neonatal clinical situations . What is New: • This study provides descriptive data on diaphragmatic function throughout the entire weaning and post-extubation process in preterm newborns undergoing a spontaneous breathing trial (SBT) .• In successfully extubated preterm newborns, diaphragmatic thickness and excursion increased during the SBT and remained elevated after extubation, suggesting that the SBT may increase respiratory effort without reliably indicating extubation readiness in this population .

  • Open Access

    Exercise training program in children and adolescents with asthma: a randomized clinical trial

    by Mariana Mazzuca Reimberg, Rebeca Souza Scalco, Bruno Ramos Salu, Andrey Jorge Serra, Gustavo Falbo Wandalsen, Dirceu Solé, Simone Dal Corso, Fernanda de Cordoba Lanza

    Objective: To evaluate, in children and adolescents with asthma, the effects of an 8-week exercise training program on exercise capacity. Methods: Single-blind, randomized clinical trial in participants with asthma between six and 17 years old under regular treatment. The intervention group performed supervised aerobic and resistance training, and the control group performed supervised stretching in 60-minute sessions twice a week for eight weeks. They were assessed at baseline and following the intervention. The primary outcomes were (VO2peak) and distance walked on the Modified Shuttle Test (MST). Secondary outcomes included quality of life, physical activity in daily living, and serum inflammatory profile. The analyses were intention-to-treat and per protocol. Results: Thirty participants in the intervention group and 29 in the control group, mean age 10±3 years old, normal lung function (forced expiratory volume — FEV1/forced vital capacity — FVC: 86±8), Global Initiative for Asthma (GINA) step: 2 (1–3). No significant differences between groups were observed at the end of the protocol regarding all outcomes. The VO2 peak was 40.3±12.4 mL/kg in the intervention group and 39.2±16.0 mL/kg in the control group (p=0.764). The distance walked on the MST was 852±219 m for the intervention group and 759±255 m for the control group (p=0.142). Conclusions: A twice-weekly, 8-week exercise program for children and adolescents with asthma did not improve exercise capacity, quality of life, or the inflammatory profile. The optimal frequency of intervention for this population requires further investigation.

  • Open Access

    “I know that exercise is very good for me”: perception of pediatric patients with cystic fibrosis about physical exercise program

    by Cristiane Cenachi Coelho, Marcella Guimarães Assis, Evanirso da Silva Aquino, Lídia Cunha de Oliveira, Priscila Souza, Anny Caroline Silva Ribeiro Oliveira, Fernanda Cordoba Lanza, Danielle Aparecida Gomes Pereira

    Objective: To explore and understand the perception of children and adolescents with cystic fibrosis diagnosis regarding the integration of a home physical exercise program into their daily routine. Methods: This study used a qualitative method. Children and adolescents diagnosed with cystic fibrosis who were being followed up in a home exercise program participated by answering a semi-structured, face-to-face interview. The data were analyzed using the thematic analysis technique. Results: Data from 38 participants were collected: 29 were pre-school/school ages (between six and 12 years old), nine were adolescents (between 13 and 16 years old). The median age of the participants was ten (interquartile range 8–10) years. Three thematic categories were identified from analyzing the interviews using a qualitative, descriptive and exploratory methodology: 1) I feel that I am better; 2) I did almost everything (all the exercises of the daily routine); 3) “If I could remove one exercise…” (the expression of preferences). Conclusions: The perception of children and adolescents with cystic fibrosis diagnosis who completed the home exercise program was that it improved their health condition. This type of program positively changed the participants’ perception of their symptoms and may allow participants diagnosed with cystic fibrosis to have greater engagement and adherence to their care.

  • Diaphragmatic ultrasonography: reference values and reliability for thickness, thickening fraction, and excursion in neonates

    by Marcos Giovanni Santos Carvalho, Juliana Nasu Tomiyama, Marcelo Azeredo Terra, Fernanda Cordoba Lanza

    To establish reference values and assess the intra- and inter-rater reliability of inspiratory diaphragmatic thickness (IDT), expiratory diaphragmatic thickness (EDT), diaphragmatic thickening fraction (DTF), and diaphragmatic excursion (DE) using ultrasound, including the lower (LLN) and upper (ULN) limits of normality in neonates. This cross-sectional study included healthy neonates from a public hospital (July 2022–December 2023). IDT, EDT, DTF, and DE were measured by PT 1 (an experienced ultrasound physiotherapist). Reliability was assessed by having PT 1 and PT 2 (experts ultrasound physiotherapists) independently evaluate the exams twice using ImageJ software. Intraclass correlation coefficients (ICC) with 95% confidence intervals (CI) were calculated to assess intra- and inter-rater reliability. One hundred neonates were assessed [39 (38–40) weeks, 3168 ± 475 g, 49 (47.5–50) cm]. Reference values were EDT: 2.17 ± 0.59 mm, LLN: 2.05 mm and ULN: 2.29 mm; IDT: 1.71 ± 0.48 mm, LLN: 1.62 mm and ULN: 1.80 mm; DTF: 28.02 ± 9.88%, LLN: 26.08% and ULN: 29.96%; DE: 2.47 ± 0.72 mm, LLN: 2.33 mm and ULN: 2.61 mm. No significant differences were observed between the assessments of PT 1 and PT 2 (p > 0.05), intra- and inter-rater reliability were ICC ≥ 0.98 (0.97–1.00) (p < 0.001) and ICC ≥ 0.91 (0.85–0.99) (p < 0.001), respectively. Conclusion: The established values support interpreting neonatal diaphragmatic function and detecting changes in contractility and motion range, with high intra- and inter-rater reliability for EDT, IDT, DTF, and DE. What is Known: • Diaphragmatic ultrasound is used to assess diaphragm function in various clinical contexts; however, its reliability and reference values for neonates are limited. What is New: • Performing diaphragmatic ultrasound in neonates requires specific precautions to obtain accurate and reliable measurements. • The established normal, lower, and upper limits for diaphragmatic thickness and excursion support the functional assessment of the diaphragm in neonates by aiding in the detection of changes in contractility and movement, providing valuable reference values for clinical decision-making.


  • ASSOBRAFIR clinical practice guidelines in respiratory physical therapy: Exercise-based interventions in people with chronic obstructive pulmonary disease (COPD)

    by Carlos Augusto Camillo, Valéria A Pires Di Lorenzo, Carla Malaguti, Celso Ricardo Fernandes de Carvalho, Ercy Mara Cipulo Ramos, Fábio de Oliveira Pitta, Marcelo Velloso, Nidia Aparecida Hernandes, Rafael Mesquita, Renata Goncalves Mendes, et al.


  • Feasibility and Reproducibility of the Unsupported Upper Limb Exercise Test and Six‐Minute Peg Board Ring Test for Children and Adolescents

    by Marina Rodrigues, Renatha Carvalho, Brenda Vilas‐Boas Gomes, Vanessa Pereira Lima, Raquel Annoni, Fernando Holguin, María Teresa Politi, Fernanda Cordoba Lanza

    Objective: To evaluate the feasibility and reproducibility of two field tests for upper limbs (Unsupported Upper Limb Exercise Test ‐ UULEX and 6‐min Pegboard Ring Test − 6PBRT) in children and adolescents. Methods: Feasibility study. Fifteen healthy volunteers aged 6–17 years were included. Lung function was performed, followed by: Cardiopulmonary Exercise Test (CPET), UULEX and 6PBRT. The CPET was performed on an upper limb ergometer using an incremental protocol. UULEX: seated arm‐raising while holding weighted bars (0.25–2.0 kg) through graded heights; outcome = test duration (min). 6PBRT: seated transfer of rings between lower and upper pegs for 6 min; outcome = total rings moved. For all tests, peak oxygen consumption (VO₂peak) was also an outcome. The UULEX and 6PBRT were performed twice each (test and retest), 30‐min apart. Feasibility criteria were (i) no major procedural difficulties and (ii) < 15% of participants reaching ceiling or floor thresholds. Results: Median age 11 [9–15] years‐old, and normal lung function (> 80% predicted). No volunteers considered the tests challenging. UULEX: Two volunteers (13%) reached the celling (13 min), none reached the floor (1 min). 6MPRT: no ceiling cases, one volunteer (6%) stopped above the floor (206 rings). The UULEX test versus retest was 9.5 [8.0−12.0] min versus 9.4 [8.2–12.0] min ( p = 0.13) (ICC = 0.93 (0.78–0.97), p < 0.001). The 6PBRT test vs. retest was 299 [258–373] rings vs. 340 [244–387] rings ( p = 0.05) (ICC = 0.97 (0.91–0.99), p < 0.001). Standard errors were < 10% of their respective medians. The CPET elicited higher VO₂peak (22.8 [19.4–26] mL/kg·min −1 ) compared to UULEX (11.8 [10.2–13.6] mL/kg) or 6PBRT (11.6 [9–12] mL/kg) ( p = 0.001). Conclusion: Both UULEX and 6PBRT are feasible and reproducible field tests for upper limbs in children and adolescents, providing practical options for upper‐limb functional assessment.

  • Open Access

    Feasibility and Reproducibility of the Unsupported Upper Limb Exercise Test And Six-Minute Peg Board Ring Test for Children and Adolescents

    by Marina Rodrigues, Renatha Carvalho, Brenda Vilas-Boas Gomes, Vanessa Pereira Lima, Raquel Annoni, Fernando Holguin, María Teresa Politi, Fernanda Lanza

    Objective: To evaluate the feasibility and reproducibility of two field tests for upper limbs (Unsupported Upper Limb Exercise Test - UULEX and Six-Minute Pegboard Ring Test - 6PBRT) in children and adolescents. Methods: Feasibility study. Fifteen healthy volunteers aged 6 to 17 years were included. Lung function was performed, followed by: Cardiopulmonary Exercise Test (CPET), UULEX and 6PBRT. The CPET was performed on an upper limb ergometer using an incremental protocol. UULEX: seated arm-raising while holding weighted bars (0.25–2.0 kg) through graded heights; outcome = test duration (min). 6PBRT: seated transfer of rings between lower and upper pegs for 6 min; outcome = total rings moved. For all tests, peak oxygen consumption (VO 2 peak) was also an outcome. The UULEX and 6PBRT were performed twice each (test and retest), 30-minute apart. Feasibility criteria were (i) no major procedural difficulties and (ii) < 15 % of participants reaching ceiling or floor thresholds. Results: 15 volunteers, median age 11 [9-15] years-old, and normal lung function (> 80% predicted). No volunteers considered the tests challenging. UULEX: Two volunteers (13%) reached the celling (13 min), none reached the floor (1 min). 6MPRT: no ceiling cases, one volunteer (6%) stopped above the floor (206 rings). The UULEX test vs. retest was 9.5 [8.0 - 12.0] min vs. 9.4 [8.2-12.0] min (p = 0.13) (ICC = 0.93 (0.78–0.97), p < 0.001). The 6PBRT test vs. retest was 299 [258-373] rings vs. 340 [244-387] rings (p = 0.05) (ICC = 0.97 (0.91–0.99), p < 0.001). Standard errors were < 10 % of their respective medians. The CPET elicited higher VO 2 peak (22.8 [19.4–26] mL/kg•min -1 ) compared to UULEX (11.8 [10.2-13.6] mL/kg) or 6PBRT (11.6 [9–12] mL/kg) (p = 0.001). Conclusion: Both UULEX and 6PBRT are feasible and reproducible field tests for upper limbs in children and adolescents, providing practical options for upper-limb functional assessment.