Lucas A. Morton
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Lucas A. Morton has a total of 314 co-authors. Here are the top co-authors by number of shared publications:
D. J. Den Hartog
Department of Physics, University of Wisconsin-Madison 1 , 1150 University Avenue, Madison, Wisconsin 53706, USA
6 shared publicationsE. Parke
Department of Physics and Astronomy, University of California Los Angeles 3 , 475 Portola Plaza, Los Angeles, California 90095, USA
5 shared publications- David S. Montgomery
Los Alamos National Laboratory (LANL), Los Alamos, NM (United States)
3 shared publications - Derek B. Schaeffer
University of California Los Angeles
3 shared publications J. Waksman
University of Wisconsin Madison
3 shared publications- Kirk Adler Flippo
Los Alamos National Laboratory , Los Alamos, New Mexico 87545, USA
3 shared publications
Latest Publications
- Open Access
- 1 July 2024
- Published by AIP Publishing in Physics of Plasmas
- Vol. 31 (7)
Plasma pressure profiles in a sheared-flow-stabilized Z-pinch
We report the plasma pressure reached inside the central plasma column of a sheared-flow-stabilized Z-pinch using Thomson scattering measurements. Building on previously reported experimental results and the analysis methods established for the high temperature and moderate density plasmas generated on the FuZE device, we show evidence of a central plasma region with higher electron temperature and density, which is consistent with a pinch behavior. Elevated electron temperatures up to 2.25 ± 0.8 keV and densities up to (4.9±0.2)×1017 cm−3 are observed to temporally coincide with the fusion neutron production from the plasma. Reconstructed plasma pressure profiles highlight the presence of a several millimeter-wide column with elevated pressure whose location varies shot-to-shot. The plasma pressure rises as neutron production from the deuterium plasma increases, reaching a peak value of 2.6 kBar. This peak value is consistent with a radially force-balanced pinch equilibrium model based on the measured ∼320 kA pinch current. Complete datasets were obtained at two axial locations, 10 and 20 cm axial position from the tip of the central electrode, which corroborate the estimated neutron source axial lengths.
- 1 July 2024
- Published by AIP Publishing in Physics of Plasmas
- Vol. 31 (7)
Open AccessPlasma pressure profiles in a sheared-flow-stabilized Z-pinch
We report the plasma pressure reached inside the central plasma column of a sheared-flow-stabilized Z-pinch using Thomson scattering measurements. Building on previously reported experimental results and the analysis methods established for the high temperature and moderate density plasmas generated on the FuZE device, we show evidence of a central plasma region with higher electron temperature and density, which is consistent with a pinch behavior. Elevated electron temperatures up to 2.25 ± 0.8 keV and densities up to (4.9±0.2)×1017 cm−3 are observed to temporally coincide with the fusion neutron production from the plasma. Reconstructed plasma pressure profiles highlight the presence of a several millimeter-wide column with elevated pressure whose location varies shot-to-shot. The plasma pressure rises as neutron production from the deuterium plasma increases, reaching a peak value of 2.6 kBar. This peak value is consistent with a radially force-balanced pinch equilibrium model based on the measured ∼320 kA pinch current. Complete datasets were obtained at two axial locations, 10 and 20 cm axial position from the tip of the central electrode, which corroborate the estimated neutron source axial lengths.
- 1 October 2022
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 93 (10) , 103535
Integrated 2D beam emission spectroscopy diagnostic at the Huan-Liuqi-2A (HL-2A) tokamak
Two newly developed, eight-channel, integrated Beam Emission Spectroscopy (BES) detectors have been installed at Huan-Liuqi-2A tokamak, which extends the existing 16 single-channel modular BES system with additional 16 spatial channels. The BES collects the Doppler-shifted Balmer Dα emission with a spatial resolution of 1 cm (radial) × 1.5 cm (poloidal) and a temporal resolution of 0.5 µs to measure long-wavelength (k⊥ρi < 1) density fluctuations. Compared to the modular BES, the dark noise of the integrated BES is reduced by 50%–60% on average. The signal-to-noise ratio of the integrated BES system is optimized by the high light throughput front-end optics, high quantum efficiency photodiodes, high-gain, low-noise preamplifiers, and sufficient cooling capacity provided by the thermoelectric cooling (TEC) units that maintain the detectors at −20 °C. Crosstalk between channels that share the same optical system is found to be negligible. High-quality density fluctuation data enables 2D (radial–poloidal) imaging of turbulence, which allows for multi-channel spectral analysis, multi-channel cross-correlation analysis and velocimetry analysis. Preliminary results show that BES successfully captures the spatiotemporal features of the local turbulence and obtains statistically consistent turbulence characterization results.
- 1 October 2022
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 93 (10) , 103535
Integrated 2D beam emission spectroscopy diagnostic at the Huan-Liuqi-2A (HL-2A) tokamak
Two newly developed, eight-channel, integrated Beam Emission Spectroscopy (BES) detectors have been installed at Huan-Liuqi-2A tokamak, which extends the existing 16 single-channel modular BES system with additional 16 spatial channels. The BES collects the Doppler-shifted Balmer Dα emission with a spatial resolution of 1 cm (radial) × 1.5 cm (poloidal) and a temporal resolution of 0.5 µs to measure long-wavelength (k⊥ρi < 1) density fluctuations. Compared to the modular BES, the dark noise of the integrated BES is reduced by 50%–60% on average. The signal-to-noise ratio of the integrated BES system is optimized by the high light throughput front-end optics, high quantum efficiency photodiodes, high-gain, low-noise preamplifiers, and sufficient cooling capacity provided by the thermoelectric cooling (TEC) units that maintain the detectors at −20 °C. Crosstalk between channels that share the same optical system is found to be negligible. High-quality density fluctuation data enables 2D (radial–poloidal) imaging of turbulence, which allows for multi-channel spectral analysis, multi-channel cross-correlation analysis and velocimetry analysis. Preliminary results show that BES successfully captures the spatiotemporal features of the local turbulence and obtains statistically consistent turbulence characterization results.
- 1 October 2021
- Published by IOP Publishing in Nuclear Fusion
- Vol. 61 (10) , 106039
Overview of C-2W: high temperature, steady-state beam-driven field-reversed configuration plasmas
- 1 October 2021
- Published by IOP Publishing in Nuclear Fusion
- Vol. 61 (10) , 106039
Overview of C-2W: high temperature, steady-state beam-driven field-reversed configuration plasmas
- 17 February 2021
- Published by IOP Publishing in Nuclear Fusion
- Vol. 61 (3) , 036032
Impact of shape on pedestal characteristics in the wide pedestal quiescent H-mode in the DIII-D tokamak
Experiments on the DIII-D tokamak have advanced the operational limits of wide pedestal quiescent H-mode plasmas towards increased ITER relevance by simultaneously demonstrating well-matched plasma shape and net zero injected torque. Wide pedestal QH-modes are a compelling candidate regime for a future power producing device because they maintain a stationary pedestal without ELMs via additional edge transport. The pedestal is wider than what would be predicted from kinetic ballooning mode physics due to enhanced edge transport generated by broadband turbulence, a limit cycle oscillation, or some combination thereof. Compared to the double null shape, the lower single null shape is observed to have a lower density, narrower pedestal width, larger density fluctuations over a broad range of wavenumber, and operates closer to the peeling-ballooning instability boundary calculated from the simple pedestal scaling, Δ ψ N , which is still observed to be wider than the EPED prediction.
- 17 February 2021
- Published by IOP Publishing in Nuclear Fusion
- Vol. 61 (3) , 036032
Impact of shape on pedestal characteristics in the wide pedestal quiescent H-mode in the DIII-D tokamak
Experiments on the DIII-D tokamak have advanced the operational limits of wide pedestal quiescent H-mode plasmas towards increased ITER relevance by simultaneously demonstrating well-matched plasma shape and net zero injected torque. Wide pedestal QH-modes are a compelling candidate regime for a future power producing device because they maintain a stationary pedestal without ELMs via additional edge transport. The pedestal is wider than what would be predicted from kinetic ballooning mode physics due to enhanced edge transport generated by broadband turbulence, a limit cycle oscillation, or some combination thereof. Compared to the double null shape, the lower single null shape is observed to have a lower density, narrower pedestal width, larger density fluctuations over a broad range of wavenumber, and operates closer to the peeling-ballooning instability boundary calculated from the simple pedestal scaling, Δ ψ N , which is still observed to be wider than the EPED prediction.
- Open Access
- 1 June 2020
- Published by AIP Publishing in Physics of Plasmas
- Vol. 27 (6) , 062507
Effect of magnetic perturbations on turbulence-flow dynamics at the L-H transition on DIII-D
Detailed 2D turbulence measurements from the DIII-D tokamak provide an explanation for how resonant magnetic perturbations (RMPs) raise the L-H power threshold [P. Gohil et al., Nucl. Fusion 51, 103020 (2011)] in ITER-relevant, low rotation, ITER-similar-shape plasmas with favorable ion direction. RMPs simultaneously raise the turbulence decorrelation rate and reduce the flow shear rate in the stationary L-mode state preceding the L-H transition, thereby disrupting the turbulence shear suppression mechanism. RMPs also reduce the Reynolds stress drive for poloidal flow, contributing to the reduction of . On the ∼100 μs timescale of the L-H transition, RMPs reduce Reynolds-stress-driven energy transfer from turbulence to flows by an order of magnitude, challenging the energy depletion theory for the L-H trigger mechanism. In contrast, non-resonant magnetic perturbations, which do not significantly affect , do not affect and only slightly reduce and Reynolds-stress-driven energy transfer.- 1 June 2020
- Published by AIP Publishing in Physics of Plasmas
- Vol. 27 (6) , 062507
Open AccessEffect of magnetic perturbations on turbulence-flow dynamics at the L-H transition on DIII-D
Detailed 2D turbulence measurements from the DIII-D tokamak provide an explanation for how resonant magnetic perturbations (RMPs) raise the L-H power threshold [P. Gohil et al., Nucl. Fusion 51, 103020 (2011)] in ITER-relevant, low rotation, ITER-similar-shape plasmas with favorable ion direction. RMPs simultaneously raise the turbulence decorrelation rate and reduce the flow shear rate in the stationary L-mode state preceding the L-H transition, thereby disrupting the turbulence shear suppression mechanism. RMPs also reduce the Reynolds stress drive for poloidal flow, contributing to the reduction of . On the ∼100 μs timescale of the L-H transition, RMPs reduce Reynolds-stress-driven energy transfer from turbulence to flows by an order of magnitude, challenging the energy depletion theory for the L-H trigger mechanism. In contrast, non-resonant magnetic perturbations, which do not significantly affect , do not affect and only slightly reduce and Reynolds-stress-driven energy transfer. - 1 October 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (10) , 10D122
Initial beam emission spectroscopy diagnostic system on HL-2A tokamak
A beam emission spectroscopy system is being developed and deployed on the HL-2A tokamak to measure local low wavenumber (k⊥ρi < 1) density fluctuations by measuring the Doppler-shifted emission from a 50 kV deuterium heating neutral beam. High spatial resolution (Δr ≤ 1 cm, Δz ≤ 1.5 cm) measurements are achieved with customized in-vacuum optics. High frequency, high-gain preamplifiers sample the light intensity at a Nyquist frequency of 1 MHz and achieve a high S/N ratio via high optical throughput, low-noise preamplifiers, and high quantum efficiency photodiodes. A first set of 16 detector channels [configured in an 8 (radial) × 2 (poloidal) array] has been installed and tested at HL-2A, covering the radial range r/a = 0.8–1.1. The frequency and wavenumber spectra have been measured under different plasma conditions. Initial measurements have demonstrated the capability of measuring edge plasma density fluctuation spectra and the poloidal flow velocity fields with a high S/N ratio.
- 1 October 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (10) , 10D122
Initial beam emission spectroscopy diagnostic system on HL-2A tokamak
A beam emission spectroscopy system is being developed and deployed on the HL-2A tokamak to measure local low wavenumber (k⊥ρi < 1) density fluctuations by measuring the Doppler-shifted emission from a 50 kV deuterium heating neutral beam. High spatial resolution (Δr ≤ 1 cm, Δz ≤ 1.5 cm) measurements are achieved with customized in-vacuum optics. High frequency, high-gain preamplifiers sample the light intensity at a Nyquist frequency of 1 MHz and achieve a high S/N ratio via high optical throughput, low-noise preamplifiers, and high quantum efficiency photodiodes. A first set of 16 detector channels [configured in an 8 (radial) × 2 (poloidal) array] has been installed and tested at HL-2A, covering the radial range r/a = 0.8–1.1. The frequency and wavenumber spectra have been measured under different plasma conditions. Initial measurements have demonstrated the capability of measuring edge plasma density fluctuation spectra and the poloidal flow velocity fields with a high S/N ratio.
- 1 April 2018
- Published by AIP Publishing in Physics of Plasmas
- Vol. 25 (4) , 042306
Electron thermal confinement in a partially stochastic magnetic structure
Using a high-repetition-rate Thomson scattering diagnostic, we observe a peak in electron temperature coinciding with the location of a large magnetic island in the Madison Symmetric Torus. Magnetohydrodynamic modeling of this quasi-single helicity plasma indicates that smaller adjacent islands overlap with and destroy the large island flux surfaces. The estimated stochastic electron thermal conductivity ( ) is consistent with the conductivity inferred from the observed gradient and ohmic heating power. Island-shaped peaks can result from partially stochastic magnetic islands.- 1 April 2018
- Published by AIP Publishing in Physics of Plasmas
- Vol. 25 (4) , 042306
Electron thermal confinement in a partially stochastic magnetic structure
Using a high-repetition-rate Thomson scattering diagnostic, we observe a peak in electron temperature coinciding with the location of a large magnetic island in the Madison Symmetric Torus. Magnetohydrodynamic modeling of this quasi-single helicity plasma indicates that smaller adjacent islands overlap with and destroy the large island flux surfaces. The estimated stochastic electron thermal conductivity ( ) is consistent with the conductivity inferred from the observed gradient and ohmic heating power. Island-shaped peaks can result from partially stochastic magnetic islands.- 13 September 2016
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87 (11) , 11E547
Upgrades to improve the usability, reliability, and spectral range of the MST Thomson scattering diagnostic
The Thomson scattering diagnostic on MST records both equilibrium and fluctuating electron temperature with a range capability of 10 eV–5 keV. Standard operation with two modified commercial Nd:YAG lasers allows measurements at rates of 1 kHz–25 kHz. Several subsystems of the diagnostic are being improved. The power supplies for the avalanche photodiode detectors (APDs) that record the scattered light are being replaced to improve usability, reliability, and maintainability. Each of the 144 APDs will have an individual rack mounted switching supply, with bias voltage adjustable to match the APD. Long-wavelength filters (1140 nm center, 80 nm bandwidth) have been added to the polychromators to improve capability to resolve non-Maxwellian distributions and to enable directed electron flow measurements. A supercontinuum (SC) pulsed white light source has replaced the tungsten halogen lamp previously used for spectral calibration of the polychromators. The SC source combines substantial brightness produced in nanosecond pulses with a spectrum that covers the entire range of the polychromators.
- 13 September 2016
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87 (11) , 11E547
Upgrades to improve the usability, reliability, and spectral range of the MST Thomson scattering diagnostic
The Thomson scattering diagnostic on MST records both equilibrium and fluctuating electron temperature with a range capability of 10 eV–5 keV. Standard operation with two modified commercial Nd:YAG lasers allows measurements at rates of 1 kHz–25 kHz. Several subsystems of the diagnostic are being improved. The power supplies for the avalanche photodiode detectors (APDs) that record the scattered light are being replaced to improve usability, reliability, and maintainability. Each of the 144 APDs will have an individual rack mounted switching supply, with bias voltage adjustable to match the APD. Long-wavelength filters (1140 nm center, 80 nm bandwidth) have been added to the polychromators to improve capability to resolve non-Maxwellian distributions and to enable directed electron flow measurements. A supercontinuum (SC) pulsed white light source has replaced the tungsten halogen lamp previously used for spectral calibration of the polychromators. The SC source combines substantial brightness produced in nanosecond pulses with a spectrum that covers the entire range of the polychromators.
- 1 August 2016
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87 (11) , 11E511
Identification and mitigation of stray laser light in the Thomson scattering system on the Madison Symmetric Torus (MST)
The Thomson scattering diagnostic on the Madison Symmetric Torus (MST) records excessive levels of stray Nd:YAG laser light. Stray light saturates the 1064 nm spectral channel in all polychromators, which prevents absolute electron density measurements via Rayleigh scattering calibration. Furthermore, stray light contaminates adjacent spectral channels for r/a ≥ 0.75, which renders the diagnostic unable to make electron temperature measurements at these radii. In situ measurements of stray light levels during a vacuum vessel vent are used to identify stray light sources and strategies for reduction of stray light levels. Numerical modeling using Zemax OpticStudio supports these measurements. The model of the vacuum vessel and diagnostic includes synthetic collection optics to enable direct comparison of measured and simulated stray light levels. Modeling produces qualitatively similar stray light distributions to MST measurements, and quantifies the mitigation effects of stray light mitigation strategies prior to implementation.
- 1 August 2016
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87 (11) , 11E511
Identification and mitigation of stray laser light in the Thomson scattering system on the Madison Symmetric Torus (MST)
The Thomson scattering diagnostic on the Madison Symmetric Torus (MST) records excessive levels of stray Nd:YAG laser light. Stray light saturates the 1064 nm spectral channel in all polychromators, which prevents absolute electron density measurements via Rayleigh scattering calibration. Furthermore, stray light contaminates adjacent spectral channels for r/a ≥ 0.75, which renders the diagnostic unable to make electron temperature measurements at these radii. In situ measurements of stray light levels during a vacuum vessel vent are used to identify stray light sources and strategies for reduction of stray light levels. Numerical modeling using Zemax OpticStudio supports these measurements. The model of the vacuum vessel and diagnostic includes synthetic collection optics to enable direct comparison of measured and simulated stray light levels. Modeling produces qualitatively similar stray light distributions to MST measurements, and quantifies the mitigation effects of stray light mitigation strategies prior to implementation.
- 1 March 2016
- Published by AIP Publishing in Physics of Plasmas
- Vol. 23 (3) , 032508
Three dimensional equilibrium solutions for a current-carrying reversed-field pinch plasma with a close-fitting conducting shell
In order to characterize the Madison Symmetric Torus (MST) reversed-field pinch (RFP) plasmas that bifurcate to a helical equilibrium, the V3FIT equilibrium reconstruction code was modified to include a conducting boundary. RFP plasmas become helical at a high plasma current, which induces large eddy currents in MST's thick aluminum shell. The V3FIT conducting boundary accounts for the contribution from these eddy currents to external magnetic diagnostic coil signals. This implementation of V3FIT was benchmarked against MSTFit, a 2D Grad-Shafranov solver, for axisymmetric plasmas. The two codes both fit Bθ measurement loops around the plasma minor diameter with qualitative agreement between each other and the measured field. Fits in the 3D case converge well, with q-profile and plasma shape agreement between two distinct toroidal locking phases. Greater than 60% of the measured n = 5 component of Bθ at r = a is due to eddy currents in the shell, as calculated by the conducting boundary model.
- 1 March 2016
- Published by AIP Publishing in Physics of Plasmas
- Vol. 23 (3) , 032508
Three dimensional equilibrium solutions for a current-carrying reversed-field pinch plasma with a close-fitting conducting shell
In order to characterize the Madison Symmetric Torus (MST) reversed-field pinch (RFP) plasmas that bifurcate to a helical equilibrium, the V3FIT equilibrium reconstruction code was modified to include a conducting boundary. RFP plasmas become helical at a high plasma current, which induces large eddy currents in MST's thick aluminum shell. The V3FIT conducting boundary accounts for the contribution from these eddy currents to external magnetic diagnostic coil signals. This implementation of V3FIT was benchmarked against MSTFit, a 2D Grad-Shafranov solver, for axisymmetric plasmas. The two codes both fit Bθ measurement loops around the plasma minor diameter with qualitative agreement between each other and the measured field. Fits in the 3D case converge well, with q-profile and plasma shape agreement between two distinct toroidal locking phases. Greater than 60% of the measured n = 5 component of Bθ at r = a is due to eddy currents in the shell, as calculated by the conducting boundary model.