Xiangyin Sha
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Xiangyin Sha has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
Amy Michelle Huang
3 shared publicationsHuyong Zou
3 shared publicationsJiayan Liu
3 shared publicationsMinzhi Zeng
3 shared publications- Xuanwei Liang
State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China
3 shared publications Zhiping Liu
3 shared publications
Latest Publications
- Open Access
- 1 January 2022
- Published by Elsevier in Experimental Eye Research
- Vol. 215, 108919
A modified high-yield method for primary culture of rat retinal microglial cells
- 1 January 2022
- Published by Elsevier in Experimental Eye Research
- Vol. 215, 108919
Open AccessA modified high-yield method for primary culture of rat retinal microglial cells
- Open Access
- 1 June 2020
- Published by AME Publishing Company in Annals of Eye Science
- Vol. 5, 11
Cytoprotective effect of amniotic membrane extracts on human corneal epithelial cells exposed to benzalkonium chloride in vitro
Background: The goal was to explore the protective effect and potential mechanism of amniotic membrane extracts (AME) on the ocular surface exposed to benzalkonium chloride (BAC). Methods: The human corneal epithelial cell (HCEC) line SD-HCEC1s was cultured in 5 groups: normal control (NC), NC + AME, BAC, BAC + NC, and BAC + AME. Cell viability analysis, flow cytometry analysis, real-time polymerase chain reaction (PCR), and western blot were employed to measure changes in cell function. Matrix metalloproteinases (MMPs) and inflammatory cytokines were assayed by enzyme-linked immunosorbent assay (ELISA) and activity assays. Results: Real-time PCR and western blot analysis demonstrated that the expressional level of caspase-8 was increased while the levels of Muc1, Muc4, and Muc16 were decreased after treatment with 0.02% BAC for 1 h. When the SD-HCEC1s were withdrawn from the BAC and switched to media containing 10% AME for 2 days, the expression level of capsase-8 was decreased while the levels of Muc1, Muc4, and Muc16 were increased. Real-time PCR and ELISA demonstrated that the mRNA and protein levels of MMP-1, MMP-3, MMP-13, CXCL1, interleukin (IL)-1β, IL-6, and tumor necrosis factor-alpha (TNF-α) were significantly increased after treatment with 0.02% BAC, whereas those of MMP-8 were decreased. When the 0.02% BAC was withdrawn and the SD-HCEC1s were cultured in 10% AME, the mRNA and protein levels of MMP-1, MMP-3, MMP-13, CXCL1, IL-1β, IL-6, and TNF-α were decreased, while those of MMP-8 were increased. MMP-8 activity assays confirmed that IL-1β and TNF-α downregulated the protein levels of MMP-8. Conclusions: AME protects SD-HCEC1s when stressed in BAC via upregulation of MMP-8 and downregulation of IL-1β and TNF-α. AME may have the potential functions to be employed as a topical adjunctive therapy in eyes chronically exposed to BAC.
- 1 June 2020
- Published by AME Publishing Company in Annals of Eye Science
- Vol. 5, 11
Open AccessCytoprotective effect of amniotic membrane extracts on human corneal epithelial cells exposed to benzalkonium chloride in vitro
Background: The goal was to explore the protective effect and potential mechanism of amniotic membrane extracts (AME) on the ocular surface exposed to benzalkonium chloride (BAC). Methods: The human corneal epithelial cell (HCEC) line SD-HCEC1s was cultured in 5 groups: normal control (NC), NC + AME, BAC, BAC + NC, and BAC + AME. Cell viability analysis, flow cytometry analysis, real-time polymerase chain reaction (PCR), and western blot were employed to measure changes in cell function. Matrix metalloproteinases (MMPs) and inflammatory cytokines were assayed by enzyme-linked immunosorbent assay (ELISA) and activity assays. Results: Real-time PCR and western blot analysis demonstrated that the expressional level of caspase-8 was increased while the levels of Muc1, Muc4, and Muc16 were decreased after treatment with 0.02% BAC for 1 h. When the SD-HCEC1s were withdrawn from the BAC and switched to media containing 10% AME for 2 days, the expression level of capsase-8 was decreased while the levels of Muc1, Muc4, and Muc16 were increased. Real-time PCR and ELISA demonstrated that the mRNA and protein levels of MMP-1, MMP-3, MMP-13, CXCL1, interleukin (IL)-1β, IL-6, and tumor necrosis factor-alpha (TNF-α) were significantly increased after treatment with 0.02% BAC, whereas those of MMP-8 were decreased. When the 0.02% BAC was withdrawn and the SD-HCEC1s were cultured in 10% AME, the mRNA and protein levels of MMP-1, MMP-3, MMP-13, CXCL1, IL-1β, IL-6, and TNF-α were decreased, while those of MMP-8 were increased. MMP-8 activity assays confirmed that IL-1β and TNF-α downregulated the protein levels of MMP-8. Conclusions: AME protects SD-HCEC1s when stressed in BAC via upregulation of MMP-8 and downregulation of IL-1β and TNF-α. AME may have the potential functions to be employed as a topical adjunctive therapy in eyes chronically exposed to BAC.
- 1 February 2020
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 46 (2) , 250-259
Transient effect of suction on the retinal neurovasculature in myopic patients after small-incision lenticule extraction
Purpose: To characterize retinal neurovasculature changes after small-incision lenticule extraction (SMILE) in myopic patients. Setting: Ophthalmic Center, the Second Affiliated Hospital of Guangzhou Medical University, China. Design: Prospective interventional study. Methods: The corrected distance visual acuity/uncorrected distance visual acuity, corrected intraocular pressure (CIOP), and corneal tomography were evaluated at baseline (PRE), postoperative day (POD) 1, and POD 7. Ganglion cell-inner plexiform layer (GCIPL) and peripapillary retinal nerve fiber layer (pRNFL) thicknesses were measured. The vessel area densities (VADs, %), vessel skeleton densities (VSDs, %), vessel diameter index (VDI), and fractal dimensions (Dbox) of the superficial vascular plexus (SVP) and deep vascular plexus (DVP) were measured in a circular area (ϕ 2.5 mm) centered on the fovea. Results: A total of 38 myopic patients were recruited. The GCIPL thickness was increased after SMILE at POD 1 and POD 7 (P < .01) but no significant changes in the pRNFL thickness. The VAD, VSD, and Dbox of the SVP were decreased at POD 1 (P < .01), but not at POD 7. The VDI in small vessels of the SVP and DVP was decreased at POD 1 (P < .05) and increased at POD 7 (P < .05). Changes in CIOP were positively correlated with changes in the GCIPL thickness. Changes in CIOP were negatively correlated with changes in the VAD of small vessels and the Dbox of total vessels in the DVP. Changes in CIOP were negatively correlated with the VSD and VDI of small vessels in the DVP and changes in the VDI of big vessels in the SVP. Conclusions: The transient fluctuations in the retinal neurovasculature after SMILE may represent a characteristic homeostasis pattern in patients after refractive surgery.
- 1 February 2020
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 46 (2) , 250-259
Transient effect of suction on the retinal neurovasculature in myopic patients after small-incision lenticule extraction
Purpose: To characterize retinal neurovasculature changes after small-incision lenticule extraction (SMILE) in myopic patients. Setting: Ophthalmic Center, the Second Affiliated Hospital of Guangzhou Medical University, China. Design: Prospective interventional study. Methods: The corrected distance visual acuity/uncorrected distance visual acuity, corrected intraocular pressure (CIOP), and corneal tomography were evaluated at baseline (PRE), postoperative day (POD) 1, and POD 7. Ganglion cell-inner plexiform layer (GCIPL) and peripapillary retinal nerve fiber layer (pRNFL) thicknesses were measured. The vessel area densities (VADs, %), vessel skeleton densities (VSDs, %), vessel diameter index (VDI), and fractal dimensions (Dbox) of the superficial vascular plexus (SVP) and deep vascular plexus (DVP) were measured in a circular area (ϕ 2.5 mm) centered on the fovea. Results: A total of 38 myopic patients were recruited. The GCIPL thickness was increased after SMILE at POD 1 and POD 7 (P < .01) but no significant changes in the pRNFL thickness. The VAD, VSD, and Dbox of the SVP were decreased at POD 1 (P < .01), but not at POD 7. The VDI in small vessels of the SVP and DVP was decreased at POD 1 (P < .05) and increased at POD 7 (P < .05). Changes in CIOP were positively correlated with changes in the GCIPL thickness. Changes in CIOP were negatively correlated with changes in the VAD of small vessels and the Dbox of total vessels in the DVP. Changes in CIOP were negatively correlated with the VSD and VDI of small vessels in the DVP and changes in the VDI of big vessels in the SVP. Conclusions: The transient fluctuations in the retinal neurovasculature after SMILE may represent a characteristic homeostasis pattern in patients after refractive surgery.
- 20 January 2020
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. Publish Ah
Transient Effect of Suction on Retinal Neuro-vasculature in Myopic Patients after Small Incision Lenticule Extraction
Purpose: To characterize retinal neuro-vasculature changes after small incision lenticule extraction (SMILE) in myopic patients. Setting: Ophthalmic Center, the Second Affiliated Hospital of Guangzhou Medical University, China. Design: Prospective, interventional study. Methods: 38 myopic patients were recruited. The corrected/uncorrected distance visual acuity (CDVA/UDVA), corrected intraocular pressure (CIOP), and corneal tomography were evaluated at baseline (PRE), post-operative day (POD) 1, and POD 7. Ganglion cell-inner plexiform layer (GCIPL) and peripapillary retinal nerve fiber layer (pRNFL) thicknesses were measured. The vessel area densities (VAD, %), vessel skeleton densities (VSD, %), vessel diameter index (VDI), and fractal dimensions (FD, Dbox) of the superficial vascular plexus (SVP) and deep vascular plexus (DVP) were measured in a circular area (ϕ 2.5 mm) centered on the fovea. Results: GCIPL thickness was increased after SMILE at POD 1 and POD 7 (p < .01) but no significant changes in pRNFL. The VAD, VSD, and Dbox of SVP were decreased at POD 1 (P< .01), but not at POD 7. The VDI in small vessels of SVP and DVP were decreased at POD 1(P< .05) and increased at POD7 (P< .05). Changes in CIOP were positively correlated with changes in GCIPL. Changes in CIOP were negatively correlated with changes in VAD of small vessels, and Dbox of total vessels in DVP. Changes in CIOP were negatively correlated with VSD and VDI of small vessels in DVP, and changes in VDI of big vessels in SVP. Conclusion: The transient fluctuations in retinal neuro-vasculature after SMILE may represent a characteristic homeostasis pattern in patients after refractive surgery.
- 20 January 2020
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. Publish Ah
Transient Effect of Suction on Retinal Neuro-vasculature in Myopic Patients after Small Incision Lenticule Extraction
Purpose: To characterize retinal neuro-vasculature changes after small incision lenticule extraction (SMILE) in myopic patients. Setting: Ophthalmic Center, the Second Affiliated Hospital of Guangzhou Medical University, China. Design: Prospective, interventional study. Methods: 38 myopic patients were recruited. The corrected/uncorrected distance visual acuity (CDVA/UDVA), corrected intraocular pressure (CIOP), and corneal tomography were evaluated at baseline (PRE), post-operative day (POD) 1, and POD 7. Ganglion cell-inner plexiform layer (GCIPL) and peripapillary retinal nerve fiber layer (pRNFL) thicknesses were measured. The vessel area densities (VAD, %), vessel skeleton densities (VSD, %), vessel diameter index (VDI), and fractal dimensions (FD, Dbox) of the superficial vascular plexus (SVP) and deep vascular plexus (DVP) were measured in a circular area (ϕ 2.5 mm) centered on the fovea. Results: GCIPL thickness was increased after SMILE at POD 1 and POD 7 (p < .01) but no significant changes in pRNFL. The VAD, VSD, and Dbox of SVP were decreased at POD 1 (P< .01), but not at POD 7. The VDI in small vessels of SVP and DVP were decreased at POD 1(P< .05) and increased at POD7 (P< .05). Changes in CIOP were positively correlated with changes in GCIPL. Changes in CIOP were negatively correlated with changes in VAD of small vessels, and Dbox of total vessels in DVP. Changes in CIOP were negatively correlated with VSD and VDI of small vessels in DVP, and changes in VDI of big vessels in SVP. Conclusion: The transient fluctuations in retinal neuro-vasculature after SMILE may represent a characteristic homeostasis pattern in patients after refractive surgery.
- Open Access
- 1 June 2017
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 58 (7) , 3044
Gap in Capillary Perfusion on Optical Coherence Tomography Angiography
We read with great interest the recent article by Tsuboi et al. 1 The authors used optical coherence tomography angiography (OCTA) and a threshold technique to evaluate correlations between persistent macular edema associated with branch retinal vein occlusion (BRVO), and the macular perfusion status in the superficial (SCP) and deep (DCP) capillary plexus. They found that the gap between the SCP and DCP (i.e., specifically the presence of isolated vessels in the SCP existing simultaneously with capillary loss in the DCP) was associated with persistent macular edema. We congratulate the authors for their excellent work and would like to make some contributions and criticisms related to this study. (1) According to the descriptions of the OCT device (RTVue-XR Avanti; OptoVue, Inc., Fremont, CA, USA), The SCP en face OCTA image was segmented with an inner boundary 3 lm below the internal limiting membrane and an outer boundary 15 lm below the inner plexiform layer. The DCP en face OCTA image was segmented with an inner boundary 15 lm below the inner plexiform layer and an outer boundary 70 lm below the inner plexiform layer. 2 For OCTA measurement, if the macular edema occurs below the inner boundary of DCP, capillary loss will be found only in the DCP, which could result in the gap between the SCP and DCP. Therefore, the authors should provide more information about the location of macular edema, which would have great influence on the results of their study. (2) The present study is a cross-section observation study. It could not
- 1 June 2017
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 58 (7) , 3044
Open AccessGap in Capillary Perfusion on Optical Coherence Tomography Angiography
We read with great interest the recent article by Tsuboi et al. 1 The authors used optical coherence tomography angiography (OCTA) and a threshold technique to evaluate correlations between persistent macular edema associated with branch retinal vein occlusion (BRVO), and the macular perfusion status in the superficial (SCP) and deep (DCP) capillary plexus. They found that the gap between the SCP and DCP (i.e., specifically the presence of isolated vessels in the SCP existing simultaneously with capillary loss in the DCP) was associated with persistent macular edema. We congratulate the authors for their excellent work and would like to make some contributions and criticisms related to this study. (1) According to the descriptions of the OCT device (RTVue-XR Avanti; OptoVue, Inc., Fremont, CA, USA), The SCP en face OCTA image was segmented with an inner boundary 3 lm below the internal limiting membrane and an outer boundary 15 lm below the inner plexiform layer. The DCP en face OCTA image was segmented with an inner boundary 15 lm below the inner plexiform layer and an outer boundary 70 lm below the inner plexiform layer. 2 For OCTA measurement, if the macular edema occurs below the inner boundary of DCP, capillary loss will be found only in the DCP, which could result in the gap between the SCP and DCP. Therefore, the authors should provide more information about the location of macular edema, which would have great influence on the results of their study. (2) The present study is a cross-section observation study. It could not
- 1 December 2014
- Vol. 29 (4) , 198-203
Toric intraocular lens vs. peripheral corneal relaxing inci- sions to correct astigmatism in eyes undergoing cataract surgery.
To compare toric intraocular lens implantation (Toric-IOL) with peripheral corneal relaxing incisions (PCRIs) for astigmatism correction in patients undergoing cataract surgery. 54 patients (54 eyes) with more than 0.75 diopter (D) of preexisting corneal astigmatism were classified as group A (0.75-1.50D) or group B (1.75-2.50D). The patients were randomized to undergo Toric-IOL or PCRIs in the steep axis with spherical IOL implantation. LogMAR uncorrected visual acuity (LogMAR UCVA), LogMAR best corrected visual acuity (LogMAR BCVA), error of vector (|EV|), surgery induced refraction correction (|SIRC|), and correction rates (CR) were measured 1 month and 6 months postoperatively. At 6 months postoperatively, all 54 eyes had LogMAR BCVA ≤ 0.2. Patients who underwent PCRIs and Toric-IOL with LogMAR BCVA ≤ 0.1 showed no significant differences in group A (P = 1.00) or in group B (P = 0.59). Group A showed no significant differences in LogMAR UCVA (P = 0.70), |EV| (P = 0.13), |SIRC| (P = 0.71), and CR (P = 0.56) in patients underwent PCRIs and Toric-IOL. However, group B showed significant differences in LogMAR UCVA (P < 0.01), |EV| (P < 0.01)), |SIRC| (P < 0.01), and CR (P < 0.01). The LogMAR UCVA and |EV| between 1 and 6 months showed no significant differences in patients in group A. However, in group B, they are significant differences. The efficacy and stability of Toric-IOL and PCRIs were equal in low astigmatic patients. Toric-IOL achieved an enhanced effect over PCRIs in higher astigmatic patients. PCRIs had the more refractive regression than Toric-IOL in 6 months.
- 1 December 2014
- Vol. 29 (4) , 198-203
Toric intraocular lens vs. peripheral corneal relaxing inci- sions to correct astigmatism in eyes undergoing cataract surgery.
To compare toric intraocular lens implantation (Toric-IOL) with peripheral corneal relaxing incisions (PCRIs) for astigmatism correction in patients undergoing cataract surgery. 54 patients (54 eyes) with more than 0.75 diopter (D) of preexisting corneal astigmatism were classified as group A (0.75-1.50D) or group B (1.75-2.50D). The patients were randomized to undergo Toric-IOL or PCRIs in the steep axis with spherical IOL implantation. LogMAR uncorrected visual acuity (LogMAR UCVA), LogMAR best corrected visual acuity (LogMAR BCVA), error of vector (|EV|), surgery induced refraction correction (|SIRC|), and correction rates (CR) were measured 1 month and 6 months postoperatively. At 6 months postoperatively, all 54 eyes had LogMAR BCVA ≤ 0.2. Patients who underwent PCRIs and Toric-IOL with LogMAR BCVA ≤ 0.1 showed no significant differences in group A (P = 1.00) or in group B (P = 0.59). Group A showed no significant differences in LogMAR UCVA (P = 0.70), |EV| (P = 0.13), |SIRC| (P = 0.71), and CR (P = 0.56) in patients underwent PCRIs and Toric-IOL. However, group B showed significant differences in LogMAR UCVA (P < 0.01), |EV| (P < 0.01)), |SIRC| (P < 0.01), and CR (P < 0.01). The LogMAR UCVA and |EV| between 1 and 6 months showed no significant differences in patients in group A. However, in group B, they are significant differences. The efficacy and stability of Toric-IOL and PCRIs were equal in low astigmatic patients. Toric-IOL achieved an enhanced effect over PCRIs in higher astigmatic patients. PCRIs had the more refractive regression than Toric-IOL in 6 months.
- 1 December 2013
- Vol. 28 (4) , 195-200
Use of silicone tubes to repair canalicular lacerations via a novel method.
To develop a novel method to repair canalicular lacerations using silicone tubes. A total of 47 adult patients (47 eyes) with canalicular lacerations were collected from the outpatient department from November 2010 to December 2012. The age ranged from 16 to 53 years. Among the 47 eyes, 37 had lower canalicular lacerations, 6 had upper canalicular lacerations, and 4 had bicanalicular lacerations. A soft probe was made using a stainless steel acupuncture needle, which was inserted into the lumen of the proximal part of the catheter to increase its rigidity. The probe was then inserted into the lacrimal sac and nasolacrimal duct. After retrieval of the catheters, the two ends of the silicone tube were securely tied (end to end) to the catheters. The silicon tube outside the nostril formed a U-shape. The catheters were then pulled upward until the silicone tube was completely located in the canalicular system. The catheters were cut off of the silicone tube near the site of the connection. The two ends of the silicone tube were cut short, -2mm out of the lacrimal punctum, and tied securely, end to end. The length of the tube between the upper and lower punctum was adjusted to ensure that no tension was present in the medial cathus, and the suture was removed through the nostril. The silicone tube was removed 3-10 months after this novel canalicular intubation procedure (NCI). All cases were anatomically rehabilitated after surgery. The silicone tube was removed after implanted in 3-10 months (mean 4.5 +/- 1.3 months), the average follow-up time was 11.8 months after removal. In total, 45 eyes in all 47 eyes (95.74%) were free from obstruction. Among them, 41 eyes (91.11%) achieved complete success (completely disappearance of epiphora after tube removal), 4 eyes (8.89%) achieved partial success (irritation occurs under stimulation conditions, such as wind or cold conditions), 4 eyes showed postoperative tearing, with three eyes having inferior lacrimal duct laceration, and one eye with superior canalicular laceration. Apart from two cases (4.26%) suffering inferior punctum splitting, no other associated issues occurred with the silicone tube or iatrogenic injury and lacrimal complications. For adult patients with canalicular laceration, the NCI was an effective, atraumatic surgery, which has fewer complications than traditional canalicular suture.
- 1 December 2013
- Vol. 28 (4) , 195-200
Use of silicone tubes to repair canalicular lacerations via a novel method.
To develop a novel method to repair canalicular lacerations using silicone tubes. A total of 47 adult patients (47 eyes) with canalicular lacerations were collected from the outpatient department from November 2010 to December 2012. The age ranged from 16 to 53 years. Among the 47 eyes, 37 had lower canalicular lacerations, 6 had upper canalicular lacerations, and 4 had bicanalicular lacerations. A soft probe was made using a stainless steel acupuncture needle, which was inserted into the lumen of the proximal part of the catheter to increase its rigidity. The probe was then inserted into the lacrimal sac and nasolacrimal duct. After retrieval of the catheters, the two ends of the silicone tube were securely tied (end to end) to the catheters. The silicon tube outside the nostril formed a U-shape. The catheters were then pulled upward until the silicone tube was completely located in the canalicular system. The catheters were cut off of the silicone tube near the site of the connection. The two ends of the silicone tube were cut short, -2mm out of the lacrimal punctum, and tied securely, end to end. The length of the tube between the upper and lower punctum was adjusted to ensure that no tension was present in the medial cathus, and the suture was removed through the nostril. The silicone tube was removed 3-10 months after this novel canalicular intubation procedure (NCI). All cases were anatomically rehabilitated after surgery. The silicone tube was removed after implanted in 3-10 months (mean 4.5 +/- 1.3 months), the average follow-up time was 11.8 months after removal. In total, 45 eyes in all 47 eyes (95.74%) were free from obstruction. Among them, 41 eyes (91.11%) achieved complete success (completely disappearance of epiphora after tube removal), 4 eyes (8.89%) achieved partial success (irritation occurs under stimulation conditions, such as wind or cold conditions), 4 eyes showed postoperative tearing, with three eyes having inferior lacrimal duct laceration, and one eye with superior canalicular laceration. Apart from two cases (4.26%) suffering inferior punctum splitting, no other associated issues occurred with the silicone tube or iatrogenic injury and lacrimal complications. For adult patients with canalicular laceration, the NCI was an effective, atraumatic surgery, which has fewer complications than traditional canalicular suture.
- 1 November 2013
- Published by Elsevier in Experimental Eye Research
- Vol. 116, 36-46
Human amniotic epithelial cell niche enhances the functional properties of human corneal endothelial cells via inhibiting P53-survivin-mitochondria axis
- 1 November 2013
- Published by Elsevier in Experimental Eye Research
- Vol. 116, 36-46
Human amniotic epithelial cell niche enhances the functional properties of human corneal endothelial cells via inhibiting P53-survivin-mitochondria axis