Robert J. Dempsey
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Robert J. Dempsey has a total of 84 co-authors. Here are the top co-authors by number of shared publications:
- Tomy Varghese
Department of Medical Physics University of Wisconsin School of Medicine and Public health (UW‐SMPH) Madison Wisconsin USA
4 shared publications - Carol C. Mitchell
University of Wisconsin School of Medicine and Public Health, Madison, USA
3 shared publications James F. Hatcher
Department of Neurological Surgery, Clinical Science Center, University of Wisconsin, 600 Highland Ave, Box 8660, Madison, WI, 53792, USA
3 shared publications- Michael M. Haglund
Department of Neurosurgery, Duke University, Durham, North Carolina, USA
3 shared publications - Umadevi V. Wesley
Department of Neurosurgery, School of Medicine and Public Health, University of Wisconsin, Madison, USA
3 shared publications Abby Klemp
Department of Neurological Surgery, Clinical Science Center, University of Wisconsin, 600 Highland Ave, Box 8660, Madison, WI, 53792, USA
2 shared publications
Latest Publications
- Open Access
- 21 September 2026
- Published by Wiley in Journal of Ultrasound in Medicine
A Standardized Technique for Ultrasound– MRI Fusion Imaging of the Carotid Artery for Vascular Assessment
Purpose: To describe a reproducible ultrasound–magnetic resonance imaging (MRI) fusion imaging technique developed for quantitative assessment of carotid wall strain and plaque morphology. Methods: MRI volumes (Oblique T2 Cube) were imported into the Sequoia ultrasound system equipped with an electromagnetic tracking module. The fusion workflow aligned ultrasound and MRI coordinate spaces through anatomical landmark registration of the internal and external carotid arteries. Real‐time B‐mode and strain imaging were performed with a 10L4 transducer. The fused MRI volume provided spatial context for localization of plaque and intima‐media regions. Following alignment, additional B‐mode, color Doppler, and radiofrequency (RF) data were acquired on a Siemens S2000/S3000 system to match the imaging plane used during fusion. Results: This workflow enabled consistent cross‐modality localization of vascular features between MRI and ultrasound, improving repeatability of acquisitions. The S2000 acquisition step ensured that color Doppler and RF data corresponded to the same anatomical orientation defined during fusion. Conclusion: This technique offers a practical framework for ultrasound–MRI fusion in carotid imaging and facilitates direct localization of similar structures across 2 imaging modalities. This approach also enables visualization across different systems with manual visual corroborations that, in this case, enabled standardized RF data collection for quantitative elastography research.
- 21 September 2026
- Published by Wiley in Journal of Ultrasound in Medicine
Open AccessA Standardized Technique for Ultrasound– MRI Fusion Imaging of the Carotid Artery for Vascular Assessment
Purpose: To describe a reproducible ultrasound–magnetic resonance imaging (MRI) fusion imaging technique developed for quantitative assessment of carotid wall strain and plaque morphology. Methods: MRI volumes (Oblique T2 Cube) were imported into the Sequoia ultrasound system equipped with an electromagnetic tracking module. The fusion workflow aligned ultrasound and MRI coordinate spaces through anatomical landmark registration of the internal and external carotid arteries. Real‐time B‐mode and strain imaging were performed with a 10L4 transducer. The fused MRI volume provided spatial context for localization of plaque and intima‐media regions. Following alignment, additional B‐mode, color Doppler, and radiofrequency (RF) data were acquired on a Siemens S2000/S3000 system to match the imaging plane used during fusion. Results: This workflow enabled consistent cross‐modality localization of vascular features between MRI and ultrasound, improving repeatability of acquisitions. The S2000 acquisition step ensured that color Doppler and RF data corresponded to the same anatomical orientation defined during fusion. Conclusion: This technique offers a practical framework for ultrasound–MRI fusion in carotid imaging and facilitates direct localization of similar structures across 2 imaging modalities. This approach also enables visualization across different systems with manual visual corroborations that, in this case, enabled standardized RF data collection for quantitative elastography research.
- 1 March 2026
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 13 (02) , 1-16
Comparison of 2D and 3D carotid plaque analysis and longitudinal in vivo ultrasound registration using 3D histology
PurposeCharacterizing carotid plaque specimens based on two-dimensional (2D) “representative” histology sections is considered standard practice in clinics. In comparison, three-dimensional (3D) histology has the potential to provide much more useful, volumetric information about carotid plaques. Despite this, due to the increased requirement for manual labor, 3D histology has been less employed for carotid plaque characterization. Evaluating the representativeness of 2D histology and exploring clinical applications of 3D carotid plaque histology, particularly in the arena of registration to and correlations with in vivo ultrasound, could be insightful.ApproachUsing 3D carotid plaque histology models, we evaluated the representativeness of 2D histology by comparing the predicted specimen composition based on 2D histology to the actual specimen composition based on 3D histology. We introduced a workflow that properly orients 3D carotid plaque histology based on transverse ultrasound and takes virtual histology slices at an angle to register histology to the longitudinal ultrasound. We correlated 3D histology composition to in vivo ultrasound parameters such as strain and grayscale features.ResultsThe 2D histology successfully predicted specimen composition (to within 3%) for 11 specimens out of 34. The 2D representative slice predictions generally overestimated calcification for more calcified specimens (≳30% calcified). Using 3D histology, we registered virtual histology to in vivo longitudinal ultrasound B-mode and strain. For B-mode, the registrations had higher IoU with respect to the ultrasonographer’s annotations (0.54±0.05) compared with the registrations with conventional 2D histology (0.30±0.08). 3D histology composition was loosely related to all strain indices and grayscale features used in the study. In one of the cases, we note that hemorrhage corresponded to opposing strains.Conclusions3D histology can be helpful for carotid plaque characterization as it enables a better understanding of plaque composition and better histology to in vivo ultrasound imaging registration.
- 1 March 2026
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 13 (02) , 1-16
Comparison of 2D and 3D carotid plaque analysis and longitudinal in vivo ultrasound registration using 3D histology
PurposeCharacterizing carotid plaque specimens based on two-dimensional (2D) “representative” histology sections is considered standard practice in clinics. In comparison, three-dimensional (3D) histology has the potential to provide much more useful, volumetric information about carotid plaques. Despite this, due to the increased requirement for manual labor, 3D histology has been less employed for carotid plaque characterization. Evaluating the representativeness of 2D histology and exploring clinical applications of 3D carotid plaque histology, particularly in the arena of registration to and correlations with in vivo ultrasound, could be insightful.ApproachUsing 3D carotid plaque histology models, we evaluated the representativeness of 2D histology by comparing the predicted specimen composition based on 2D histology to the actual specimen composition based on 3D histology. We introduced a workflow that properly orients 3D carotid plaque histology based on transverse ultrasound and takes virtual histology slices at an angle to register histology to the longitudinal ultrasound. We correlated 3D histology composition to in vivo ultrasound parameters such as strain and grayscale features.ResultsThe 2D histology successfully predicted specimen composition (to within 3%) for 11 specimens out of 34. The 2D representative slice predictions generally overestimated calcification for more calcified specimens (≳30% calcified). Using 3D histology, we registered virtual histology to in vivo longitudinal ultrasound B-mode and strain. For B-mode, the registrations had higher IoU with respect to the ultrasonographer’s annotations (0.54±0.05) compared with the registrations with conventional 2D histology (0.30±0.08). 3D histology composition was loosely related to all strain indices and grayscale features used in the study. In one of the cases, we note that hemorrhage corresponded to opposing strains.Conclusions3D histology can be helpful for carotid plaque characterization as it enables a better understanding of plaque composition and better histology to in vivo ultrasound imaging registration.
- 5 September 2024
- Published by Elsevier in Neurosurgery Clinics of North America
- Vol. 35 (4)
Forthcoming Issues
- 5 September 2024
- Published by Elsevier in Neurosurgery Clinics of North America
- Vol. 35 (4)
Forthcoming Issues
- 5 September 2024
- Published by Elsevier in Neurosurgery Clinics of North America
- Vol. 35 (4)
Contributors
- 5 September 2024
- Published by Elsevier in Neurosurgery Clinics of North America
- Vol. 35 (4)
Contributors
- 26 July 2024
- Published by Elsevier in Neurosurgery Clinics of North America
- Vol. 35 (4)
Service Through Education: Inspiring a Generation of Change in Global Neurosurgery
- 26 July 2024
- Published by Elsevier in Neurosurgery Clinics of North America
- Vol. 35 (4)
Service Through Education: Inspiring a Generation of Change in Global Neurosurgery
- 15 June 2024
- Published by Elsevier in Neurosurgery Clinics of North America
- Vol. 35 (4) , 499-507
Postgraduate Fellowships, Distant Continuing Education, and Funding in Neurosurgical Education
- 15 June 2024
- Published by Elsevier in Neurosurgery Clinics of North America
- Vol. 35 (4) , 499-507
Postgraduate Fellowships, Distant Continuing Education, and Funding in Neurosurgical Education
- 15 June 2024
- Published by Elsevier in Neurosurgery Clinics of North America
- Vol. 35 (4) , 475-480
Nongovernmental Organizations in Global Neurosurgery
- 15 June 2024
- Published by Elsevier in Neurosurgery Clinics of North America
- Vol. 35 (4) , 475-480
Nongovernmental Organizations in Global Neurosurgery
- 27 September 2023
- Published by Springer Nature
- p. 5-7
Lessons Learned from Four Decades of Neurosurgical Global Health Experience
- 27 September 2023
- Published by Springer Nature
- p. 5-7
Lessons Learned from Four Decades of Neurosurgical Global Health Experience
- 27 September 2023
- Published by Springer Nature
- p. 19-22
Appalachian Patients