NRNik Rajic

Nik Rajic

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Nik Rajic has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    An Advanced Multi-Sensor Acousto-Ultrasonic Structural Health Monitoring System: Development and Aerospace Demonstration

    by Joel Smithard, Nik Rajic, Stephen Van der Velden, Patrick Norman, Cedric Rosalie, Steve Galea, Hanfei Mei, Bin Lin, Victor Giurgiutiu

    A key longstanding objective of the Structural Health Monitoring (SHM) research community is to enable the embedment of SHM systems in high value assets like aircraft to provide on-demand damage detection and evaluation. As against traditional non-destructive inspection hardware, embedded SHM systems must be compact, lightweight, low-power and sufficiently robust to survive exposure to severe in-flight operating conditions. Typical Commercial-Off-The-Shelf (COTS) systems can be bulky, costly and are often inflexible in their configuration and/or scalability, which militates against in-service deployment. Advances in electronics have resulted in ever smaller, cheaper and more reliable components that facilitate the development of compact and robust embedded SHM systems, including for Acousto-Ultrasonics (AU), a guided plate-wave inspection modality that has attracted strong interest due mainly to its capacity to furnish wide-area diagnostic coverage with a relatively low sensor density. This article provides a detailed description of the development, testing and demonstration of a new AU interrogation system called the Acousto Ultrasonic Structural health monitoring Array Module+ (AUSAM+). This system provides independent actuation and sensing on four Piezoelectric Wafer Active Sensor (PWAS) elements with further sensing on four Positive Intrinsic Negative (PIN) photodiodes for intensity-based interrogation of Fiber Bragg Gratings (FBG). The paper details the development of a novel piezoelectric excitation amplifier, which, in conjunction with flexible acquisition-system architecture, seamlessly provides electromechanical impedance spectroscopy for PWAS diagnostics over the full instrument bandwidth of 50 KHz–5 MHz. The AUSAM+ functionality is accessed via a simple hardware object providing a myriad of custom software interfaces that can be adapted to suit the specific requirements of each individual application.


  • Thermoelastic stress analysis and structural health monitoring: An emerging nexus

    by Nik Rajic, Steve Galea

    Recent innovations in thermal-detector technology are shown to foster the development of an in situ structural health monitoring capability based on thermoelastic stress analysis, a powerful full-field stress-measurement technique that offers an attractive set of diagnostic and prognostic capabilities, some of which are not found in any of the established structural health monitoring modalities. After reviewing these capabilities, the article examines an experimental case study involving the monitoring of an F/A-18 airframe structure subject to full-scale fatigue testing under representative flight spectrum loading spanning nearly one aircraft life time. The case study confirms the viability of the concept and also highlights some of its primary limitations.


  • Open Access

    A performance comparison between cooled and uncooled infrared detectors for thermoelastic stress analysis

    by Nik Rajic, Neil Street

    This study compares the stress-measurement sensitivity of several commercially available vanadium-oxide microbolometers to a scientific grade cooled indium antimonide imager. The devices were tested under similar conditions on the same mechanically-loaded subjects; one a uniaxially loaded plate containing a circular hole and the other a representative aircraft wing-skin coupon. The microbolometers are shown to consistently outperform the cooled imager for scan durations of 1500 load cycles or more despite having noise equivalent temperature detectivities (NETD) that were inferior by factors of between approximately 2 and 6. This finding is significant in two respects: it suggests that an NETD specification has only limited value as a sensitivity metric for thermoelastic stress analysis and secondly it confirms that microbolometers are able to furnish high-fidelity stress measurements of a type traditionally associated with cooled infrared imagers which are generally more costly to acquire and more cumbersome to use.


  • Open Access

    Thermoelastic stress analysis with a compact low-cost microbolometer system

    by Nik Rajic, David Rowlands

    This article describes the development and validation of a novel thermoelastic stress analysis (TSA) system based on a low-cost microbolometer device. The use of a microbolometer for a highly synchronous and delicate temperature measurement breaks a longstanding and exclusive reliance on high performance, cooled photon detectors for thermoelastic applications. It is shown that despite markedly inferior noise equivalent temperature detectivity and dynamic response specifications, microbolometers are capable of achieving comparable levels of stress measurement performance. The practical implications for experimental stress analysis are significant. Microbolometers are relatively low in capital cost, small in size, have good tolerance to shock and vibration and consume less power than their photon counterparts, attributes that confer enormous practical advantages. It is argued that the emergence of TSA systems that are more affordable and better suited to in-service application could help to promote a much broader use of this powerful technique in applications across the life cycle of high value civil, maritime and aerospace assets, from the validation of finite element modelling for design to in-service structural integrity assessment. A full-scale fatigue test of a flight-critical aircraft structural component is employed as a case study to demonstrate important aspects of the capability. Future directions in the development and application of low-cost miniaturised systems are also discussed.