Antonio De Simone
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Antonio De Simone has a total of 100 co-authors. Here are the top co-authors by number of shared publications:
Valter Bianchi
Unità Operativa di Elettrofisiologia, Studio e Terapia delle Aritmie, Azienda Ospedaliera dei Colli - Monaldi, Via Leonardo Bianchi, 1, 80131, Naples, Italy
5 shared publicationsErnesto Ammendola
Chair of Cardiology, University of Campania "Luigi Vanvitelli", Monaldi, Ospedale Monaldi, Via Leonardo Bianchi 1, Naples, Italy
4 shared publicationsMaria Grazia Bongiorni
Second Cardiology Division, Cardio-Thoracic and Vascular Department, University Hospital of Pisa, Pisa, Italy
4 shared publications- Sergio Valsecchi
Boston Scientific Italia Milan Italy
4 shared publications Eraldo Occhetta
Ospedale Maggiore della Carità, Novara, Italy
3 shared publicationsGianluca Botto
S. Anna Hospital, Como, Italy
3 shared publications
Latest Publications
- 17 March 2020
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 60 (2) , 195-203
Single- and multi-site pacing strategies for optimal cardiac resynchronization therapy: impact on device longevity and therapy cost
Background Multiple left ventricular pacing strategies have been suggested for improving response to cardiac resynchronization therapy (CRT). However, these programming strategies may sometimes entail accepting configurations with high pacing threshold and accelerated battery drain. We assessed the feasibility of predefined pacing programming protocols, and we evaluated their impact on device longevity and their cost-impact. Methods We estimated battery longevity in 167 CRT-D patients based on measured pacing parameters according to multiple alternative programming strategies: single-site pacing associated with lowest threshold, non-apical location, longest interventricular delay, and pacing from two electrodes. To determine the economic impact of each programming strategy, we applied the results of a model-based cost analysis using a 15-year time horizon. Results Selecting the electrode with the lowest threshold resulted in a median device longevity of 11.5 years. Non-apical pacing and interventricular delay maximization were feasible in most patients and were obtained at the price of a few months of battery life. Device longevity of > 10 years was preserved in 87% of cases of non-apical pacing and in 77% on pacing at the longest interventricular delay. The mean reduction in battery life when the second electrode was activated was 1.5 years. Single-site pacing strategies increased the therapy cost by 4–6%, and multi-site pacing by 12–13%, in comparison with the lowest-cost scenario. Conclusions Modern CRT-D systems ensure effective pacing and allow multiple optimization strategies for maximizing service life or for enhancing effectiveness. Single- or multi-site pacing strategies can be implemented without compromising device service life and at an acceptable increase in therapy cost.
- 17 March 2020
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 60 (2) , 195-203
Single- and multi-site pacing strategies for optimal cardiac resynchronization therapy: impact on device longevity and therapy cost
Background Multiple left ventricular pacing strategies have been suggested for improving response to cardiac resynchronization therapy (CRT). However, these programming strategies may sometimes entail accepting configurations with high pacing threshold and accelerated battery drain. We assessed the feasibility of predefined pacing programming protocols, and we evaluated their impact on device longevity and their cost-impact. Methods We estimated battery longevity in 167 CRT-D patients based on measured pacing parameters according to multiple alternative programming strategies: single-site pacing associated with lowest threshold, non-apical location, longest interventricular delay, and pacing from two electrodes. To determine the economic impact of each programming strategy, we applied the results of a model-based cost analysis using a 15-year time horizon. Results Selecting the electrode with the lowest threshold resulted in a median device longevity of 11.5 years. Non-apical pacing and interventricular delay maximization were feasible in most patients and were obtained at the price of a few months of battery life. Device longevity of > 10 years was preserved in 87% of cases of non-apical pacing and in 77% on pacing at the longest interventricular delay. The mean reduction in battery life when the second electrode was activated was 1.5 years. Single-site pacing strategies increased the therapy cost by 4–6%, and multi-site pacing by 12–13%, in comparison with the lowest-cost scenario. Conclusions Modern CRT-D systems ensure effective pacing and allow multiple optimization strategies for maximizing service life or for enhancing effectiveness. Single- or multi-site pacing strategies can be implemented without compromising device service life and at an acceptable increase in therapy cost.
- 1 December 2018
- Published by Elsevier in International Journal of Cardiology
- Vol. 272, 162-167
Subcutaneous implantable cardioverter defibrillator implantation: An analysis of Italian clinical practice and its evolution
- 1 December 2018
- Published by Elsevier in International Journal of Cardiology
- Vol. 272, 162-167
Subcutaneous implantable cardioverter defibrillator implantation: An analysis of Italian clinical practice and its evolution
- Open Access
- 31 October 2017
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 20 (FI2) , f233-f239
Effects of defibrillation shock in patients implanted with a subcutaneous defibrillator: a biomarker study
Implantable cardioverter defibrillator (ICD) shocks are associated with a subsequent increased risk of death, and an elevation of cardiac enzymes has been measured after defibrillation testing (DFT). In an experimental swine study, subcutaneous ICD (S-ICD) shocks caused less myocardial damage than traditional ICD shocks. The aim of our study was to investigate the association between S-ICD shock and acute cardiac damage in humans, as evaluated by means of sensitive and highly specific circulating biomarkers. We calculated the variation in the serum levels of high-sensitivity cardiac troponin I (hs-CTnI) and creatine kinase-MB mass concentration (CK-MB mass), measured before and after an S-ICD shock delivered during intraoperative DFT. We also measured the degree of haemodynamic stress, as the variation in the serum levels of N-terminal pro-B-type natriuretic peptide (NT-proBNP) and copeptin (CP), after the S-ICD shock. We analysed 30 consecutive patients who received an S-ICD and who underwent DFT by means of a single 65 J shock. The levels of biomarkers did not change from baseline to 1 h post-shock, i.e. hs-CTnI (from 0.029 ± 0.005 ng/mL to 0.030 ± 0.005 ng/mL, P = 0.079) and CK-MB mass (from 1.37 ± 0.17 ng/mL to 1.41 ± 0.18, P = 0.080) and remained stable 6 and 24 h after DFT. The plasma NT-proBNP did not change, whereas CP levels were significantly higher at 1 h post-shock evaluation. However, 6 h after DFT, the levels had returned to the baseline and remained stable at 24 h. The S-ICD shock did not seem to cause myocardial injuries. Although CP levels temporarily rose after DFT, they returned to basal levels within 6 h, which suggests that DFT does not have long-term prognostic implications. ICD shocks are associated with a subsequent increased risk of death, and an elevation of cardiac enzymes has been measured after DFT. We showed that serum levels of biomarkers of myocardial damage did not increase after high-energy DFT in patients who had undergone S-ICD device implantation. This suggests that S-ICD shock does not have long-term prognostic implications.
- 31 October 2017
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 20 (FI2) , f233-f239
Open AccessEffects of defibrillation shock in patients implanted with a subcutaneous defibrillator: a biomarker study
Implantable cardioverter defibrillator (ICD) shocks are associated with a subsequent increased risk of death, and an elevation of cardiac enzymes has been measured after defibrillation testing (DFT). In an experimental swine study, subcutaneous ICD (S-ICD) shocks caused less myocardial damage than traditional ICD shocks. The aim of our study was to investigate the association between S-ICD shock and acute cardiac damage in humans, as evaluated by means of sensitive and highly specific circulating biomarkers. We calculated the variation in the serum levels of high-sensitivity cardiac troponin I (hs-CTnI) and creatine kinase-MB mass concentration (CK-MB mass), measured before and after an S-ICD shock delivered during intraoperative DFT. We also measured the degree of haemodynamic stress, as the variation in the serum levels of N-terminal pro-B-type natriuretic peptide (NT-proBNP) and copeptin (CP), after the S-ICD shock. We analysed 30 consecutive patients who received an S-ICD and who underwent DFT by means of a single 65 J shock. The levels of biomarkers did not change from baseline to 1 h post-shock, i.e. hs-CTnI (from 0.029 ± 0.005 ng/mL to 0.030 ± 0.005 ng/mL, P = 0.079) and CK-MB mass (from 1.37 ± 0.17 ng/mL to 1.41 ± 0.18, P = 0.080) and remained stable 6 and 24 h after DFT. The plasma NT-proBNP did not change, whereas CP levels were significantly higher at 1 h post-shock evaluation. However, 6 h after DFT, the levels had returned to the baseline and remained stable at 24 h. The S-ICD shock did not seem to cause myocardial injuries. Although CP levels temporarily rose after DFT, they returned to basal levels within 6 h, which suggests that DFT does not have long-term prognostic implications. ICD shocks are associated with a subsequent increased risk of death, and an elevation of cardiac enzymes has been measured after DFT. We showed that serum levels of biomarkers of myocardial damage did not increase after high-energy DFT in patients who had undergone S-ICD device implantation. This suggests that S-ICD shock does not have long-term prognostic implications.
- 1 June 2017
- Published by Elsevier in International Journal of Cardiology
- Vol. 236, 290-295
Effectiveness of a management program for outpatient clinic or remote titration of beta-blockers in CRT patients: The RESTORE study
- 1 June 2017
- Published by Elsevier in International Journal of Cardiology
- Vol. 236, 290-295
Effectiveness of a management program for outpatient clinic or remote titration of beta-blockers in CRT patients: The RESTORE study
- Open Access
- 10 November 2016
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 17 (11) , 1883
Functional Studies and In Silico Analyses to Evaluate Non-Coding Variants in Inherited Cardiomyopathies
Point mutations are the most common cause of inherited diseases. Bioinformatics tools can help to predict the pathogenicity of mutations found during genetic screening, but they may work less well in determining the effect of point mutations in non-coding regions. In silico analysis of intronic variants can reveal their impact on the splicing process, but the consequence of a given substitution is generally not predictable. The aim of this study was to functionally test five intronic variants (MYBPC3-c.506-2A>C, MYBPC3-c.906-7G>T, MYBPC3-c.2308+3G>C, SCN5A-c.393-5C>A, and ACTC1-c.617-7T>C) found in five patients affected by inherited cardiomyopathies in the attempt to verify their pathogenic role. Analysis of the MYBPC3-c.506-2A>C mutation in mRNA from the peripheral blood of one of the patients affected by hypertrophic cardiac myopathy revealed the loss of the canonical splice site and the use of an alternative splicing site, which caused the loss of the first seven nucleotides of exon 5 (MYBPC3-G169AfsX14). In the other four patients, we generated minigene constructs and transfected them in HEK-293 cells. This minigene approach showed that MYBPC3-c.2308+3G>C and SCN5A-c.393-5C>A altered pre-mRNA processing, thus resulting in the skipping of one exon. No alterations were found in either MYBPC3-c.906-7G>T or ACTC1-c.617-7T>C. In conclusion, functional in vitro analysis of the effects of potential splicing mutations can confirm or otherwise the putative pathogenicity of non-coding mutations, and thus help to guide the patient's clinical management and improve genetic counseling in affected families.
- 10 November 2016
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 17 (11) , 1883
Open AccessFunctional Studies and In Silico Analyses to Evaluate Non-Coding Variants in Inherited Cardiomyopathies
Point mutations are the most common cause of inherited diseases. Bioinformatics tools can help to predict the pathogenicity of mutations found during genetic screening, but they may work less well in determining the effect of point mutations in non-coding regions. In silico analysis of intronic variants can reveal their impact on the splicing process, but the consequence of a given substitution is generally not predictable. The aim of this study was to functionally test five intronic variants (MYBPC3-c.506-2A>C, MYBPC3-c.906-7G>T, MYBPC3-c.2308+3G>C, SCN5A-c.393-5C>A, and ACTC1-c.617-7T>C) found in five patients affected by inherited cardiomyopathies in the attempt to verify their pathogenic role. Analysis of the MYBPC3-c.506-2A>C mutation in mRNA from the peripheral blood of one of the patients affected by hypertrophic cardiac myopathy revealed the loss of the canonical splice site and the use of an alternative splicing site, which caused the loss of the first seven nucleotides of exon 5 (MYBPC3-G169AfsX14). In the other four patients, we generated minigene constructs and transfected them in HEK-293 cells. This minigene approach showed that MYBPC3-c.2308+3G>C and SCN5A-c.393-5C>A altered pre-mRNA processing, thus resulting in the skipping of one exon. No alterations were found in either MYBPC3-c.906-7G>T or ACTC1-c.617-7T>C. In conclusion, functional in vitro analysis of the effects of potential splicing mutations can confirm or otherwise the putative pathogenicity of non-coding mutations, and thus help to guide the patient's clinical management and improve genetic counseling in affected families.
- 9 July 2016
- Published by SAGE Publications in Journal of Telemedicine and Telecare
- Vol. 22 (7) , 383-390
Association between remote implantable cardioverter defibrillator monitoring and beta-blocker utilization: An analysis from the EFFECT study
A substantial number of heart failure patients undergoing implantation of implantable cardioverter defibrillators (ICDs) fail to receive beta-blockers, or receive them at a suboptimal dose. Remote monitoring (RM) is becoming the standard means of following up recipients of ICDs. However, the impact of this shift toward remote ICD follow-up on the quality of drug therapy management in current clinical practice is unknown. The present analysis was aimed at investigating the impact of RM on the dose of beta-blockers achieved, and its association with clinical outcome at 12 months. Altogether 987 consecutive patients were enrolled and followed up for at least 12 months in 25 Italian centres. RM was adopted by 499 patients. The number of patients receiving beta-blockers at any dose decreased after 12 months (from 403 (81%) to 370 (74%) for the remote arm and from 389 (80%) to 342 (70%) for the standard arm, both p < 0.02). Nonetheless, the number of patients on beta-blockers at the effective dose increased in both arms (from 60 (12%) to 82 (16%) for remote and from 63 (13%) to 98 (20%) for standard arms respectively, both p < 0.05). At multivariate analysis, RM was not associated with an effective dose of beta-blockers at the follow-up evaluation. However, the adoption of RM (p = 0.003) and the achievement of the effective dose of beta-blockers (p = 0.006) were independently and positively associated with an improved outcome. In a ‘real-world’ setting, we did not find an association between RM and the achieved dose of beta-blockers. However, we reported outcome benefits in achieving the effective dose of beta-blockers during follow-up and in adopting RM.
- 9 July 2016
- Published by SAGE Publications in Journal of Telemedicine and Telecare
- Vol. 22 (7) , 383-390
Association between remote implantable cardioverter defibrillator monitoring and beta-blocker utilization: An analysis from the EFFECT study
A substantial number of heart failure patients undergoing implantation of implantable cardioverter defibrillators (ICDs) fail to receive beta-blockers, or receive them at a suboptimal dose. Remote monitoring (RM) is becoming the standard means of following up recipients of ICDs. However, the impact of this shift toward remote ICD follow-up on the quality of drug therapy management in current clinical practice is unknown. The present analysis was aimed at investigating the impact of RM on the dose of beta-blockers achieved, and its association with clinical outcome at 12 months. Altogether 987 consecutive patients were enrolled and followed up for at least 12 months in 25 Italian centres. RM was adopted by 499 patients. The number of patients receiving beta-blockers at any dose decreased after 12 months (from 403 (81%) to 370 (74%) for the remote arm and from 389 (80%) to 342 (70%) for the standard arm, both p < 0.02). Nonetheless, the number of patients on beta-blockers at the effective dose increased in both arms (from 60 (12%) to 82 (16%) for remote and from 63 (13%) to 98 (20%) for standard arms respectively, both p < 0.05). At multivariate analysis, RM was not associated with an effective dose of beta-blockers at the follow-up evaluation. However, the adoption of RM (p = 0.003) and the achievement of the effective dose of beta-blockers (p = 0.006) were independently and positively associated with an improved outcome. In a ‘real-world’ setting, we did not find an association between RM and the achieved dose of beta-blockers. However, we reported outcome benefits in achieving the effective dose of beta-blockers during follow-up and in adopting RM.
- 4 March 2014
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 25 (5) , 500-506
Incremental Value of Larger Interventricular Conduction Time in Improving Cardiac Resynchronization Therapy Outcome in Patients with Different QRS Duration
Interventricular Electrical Delay: Introduction: The left ventricular (LV) pacing site and the magnitude of the electrical delay within the LV, as expressed by prolonged QRS duration, are major determinants of cardiac resynchronization therapy (CRT) efficacy. We investigated the incremental value of positioning the LV lead in areas of late activation in order to enhance the response to CRT in patients with different degrees of QRS complex lengthening.Methods and Results: This analysis was performed on 301 heart failure patients who received a CRT defibrillator. On implantation, the right ventricular (RV)‐to‐LV interval was measured as the delay between local activations recorded through the RV and LV leads in the final position. After 1 year, 171 (57%) patients displayed reverse LV remodeling, as measured by a ≥15% reduction in the LV end‐systolic volume. Both the RV‐to‐LV interval and its percentage value corrected for the QRS duration were significantly associated with a positive response to CRT. An RV‐to‐LV interval >80 milliseconds and an RV‐to‐LV interval/QRS >58% yielded the best prediction of reverse remodeling. Although the response to CRT decreased with shorter QRS duration in the overall population, patients with an RV‐to‐LV interval >80 milliseconds showed a response rate >65% in all QRS subgroups.Conclusion: A longer RV‐to‐LV interval is associated with reverse LV remodeling after CRT. On implantation attempts could be made to maximize it when selecting the LV lead position, especially in patients with shorter QRS duration, and thus less likely to respond positively to CRT.
- 4 March 2014
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 25 (5) , 500-506
Incremental Value of Larger Interventricular Conduction Time in Improving Cardiac Resynchronization Therapy Outcome in Patients with Different QRS Duration
Interventricular Electrical Delay: Introduction: The left ventricular (LV) pacing site and the magnitude of the electrical delay within the LV, as expressed by prolonged QRS duration, are major determinants of cardiac resynchronization therapy (CRT) efficacy. We investigated the incremental value of positioning the LV lead in areas of late activation in order to enhance the response to CRT in patients with different degrees of QRS complex lengthening.Methods and Results: This analysis was performed on 301 heart failure patients who received a CRT defibrillator. On implantation, the right ventricular (RV)‐to‐LV interval was measured as the delay between local activations recorded through the RV and LV leads in the final position. After 1 year, 171 (57%) patients displayed reverse LV remodeling, as measured by a ≥15% reduction in the LV end‐systolic volume. Both the RV‐to‐LV interval and its percentage value corrected for the QRS duration were significantly associated with a positive response to CRT. An RV‐to‐LV interval >80 milliseconds and an RV‐to‐LV interval/QRS >58% yielded the best prediction of reverse remodeling. Although the response to CRT decreased with shorter QRS duration in the overall population, patients with an RV‐to‐LV interval >80 milliseconds showed a response rate >65% in all QRS subgroups.Conclusion: A longer RV‐to‐LV interval is associated with reverse LV remodeling after CRT. On implantation attempts could be made to maximize it when selecting the LV lead position, especially in patients with shorter QRS duration, and thus less likely to respond positively to CRT.
- 1 March 2014
- Published by Elsevier in International Journal of Cardiology
- Vol. 172 (2) , e271-e272
Geometrical characteristics of interventricular electrical delay
- 1 March 2014
- Published by Elsevier in International Journal of Cardiology
- Vol. 172 (2) , e271-e272
Geometrical characteristics of interventricular electrical delay
- 1 October 2013
- Published by Elsevier in International Journal of Cardiology
- Vol. 168 (5) , 5067-5068
The interventricular conduction time is associated with response to cardiac resynchronization therapy
- 1 October 2013
- Published by Elsevier in International Journal of Cardiology
- Vol. 168 (5) , 5067-5068
The interventricular conduction time is associated with response to cardiac resynchronization therapy
- 6 November 2012
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 24 (2) , 173-181
Clinical Characteristics, Mortality, Cardiac Hospitalization, and Ventricular Arrhythmias in Patients Undergoing CRT‐D Implantation: Results of the ACTION‐HF Study
The characteristics and outcomes of patients who undergo cardiac resynchronization therapy (CRT) device implantation in current clinical practice may differ from those of reference trial populations. Study objectives were to assess 2-year outcomes in a population implanted with a CRT plus defibrillator device in accordance with the standard of care and to evaluate any independent association between clinical variables and outcome. A total of 406 patients enrolled at 35 centers in Italy were followed up prospectively for 2 years. All patient management decisions were left to the treating physician's discretion, in accordance with clinical practice. ACTION-HF patients had a better baseline clinical status than patients enrolled in the COMPANION study: shorter HF history (1 vs 3.5 years, P < 0.01), less advanced NYHA functional class (III-IV: 73% vs 100%, P < 0.01), higher LVEF (26% vs 21%, P < 0.01), higher SBP (122 vs 112 mmHg, P < 0.01), and less diabetes (27% vs 41%, P < 0.01). This status was reflected in lower mortality (11.5% vs 26%) and a lower incidence of appropriate ICD shocks (12.1% vs 19.3%). AF history was an independent predictor of the combination of all-cause mortality and cardiac-cause hospitalization (HR: 3.31; P < 0.001). Recurrent or new atrial arrhythmias were independently associated with the development of ventricular arrhythmias (HR: 3.4; P < 0.001). This population appears clinically less compromised and had a lower incidence of adverse clinical outcomes than those of reference trials. However, we recorded a substantial burden of atrial arrhythmias, which was independently associated with a higher incidence of ventricular arrhythmias.
- 6 November 2012
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 24 (2) , 173-181
Clinical Characteristics, Mortality, Cardiac Hospitalization, and Ventricular Arrhythmias in Patients Undergoing CRT‐D Implantation: Results of the ACTION‐HF Study
The characteristics and outcomes of patients who undergo cardiac resynchronization therapy (CRT) device implantation in current clinical practice may differ from those of reference trial populations. Study objectives were to assess 2-year outcomes in a population implanted with a CRT plus defibrillator device in accordance with the standard of care and to evaluate any independent association between clinical variables and outcome. A total of 406 patients enrolled at 35 centers in Italy were followed up prospectively for 2 years. All patient management decisions were left to the treating physician's discretion, in accordance with clinical practice. ACTION-HF patients had a better baseline clinical status than patients enrolled in the COMPANION study: shorter HF history (1 vs 3.5 years, P < 0.01), less advanced NYHA functional class (III-IV: 73% vs 100%, P < 0.01), higher LVEF (26% vs 21%, P < 0.01), higher SBP (122 vs 112 mmHg, P < 0.01), and less diabetes (27% vs 41%, P < 0.01). This status was reflected in lower mortality (11.5% vs 26%) and a lower incidence of appropriate ICD shocks (12.1% vs 19.3%). AF history was an independent predictor of the combination of all-cause mortality and cardiac-cause hospitalization (HR: 3.31; P < 0.001). Recurrent or new atrial arrhythmias were independently associated with the development of ventricular arrhythmias (HR: 3.4; P < 0.001). This population appears clinically less compromised and had a lower incidence of adverse clinical outcomes than those of reference trials. However, we recorded a substantial burden of atrial arrhythmias, which was independently associated with a higher incidence of ventricular arrhythmias.