DKDaisuke Komoto

Daisuke Komoto

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Daisuke Komoto has a total of 29 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Diffusion-weighted MR imaging of non-complicated hepatic cysts: Value of 3T computed diffusion-weighted imaging

    by Yuko Nakamura, Toru Higaki, Yuji Akiyama, Wataru Fukumoto, Kenji Kajiwara, Yoko Kaichi, Yukiko Honda, Daisuke Komoto, Fuminari Tatsugami, Makoto Iida, et al.


    • 1 December 2015
      • Vol. 64  (4) , 51-7

    Diagnostic Performance of Positron Emission Tomography for the Presurgical Evaluation of Patients with Non-lesional Intractable Partial Epilepsy: Comparison among 18F-FDG, 11C-Flumazenil, and 11C-Flumazenil Binding Potential Imaging Using Statistical Imaging Analysis.

    by Daisuke Komoto, Koji Iida, Toru Higaki, Yoko Kaichi, Komei Takauchi, Koji Arihiro, Akiyoshi Kakita, Yutaka Hirokawa, Kazuo Awai

    To compare the diagnostic performance of 18F-FDG PET, 11C-FMZ PET, and 11C-FMZ BP imaging for the evaluation of patients with intractable partial epilepsy whose MRI findings are normal by using statistical imaging analysis. Ten patients underwent comprehensive presurgical evaluation, including PET studies, to assess the epileptic foci. The extent of cortical resection was based on the results of intracranial video-electroencephalography (IVEEG) monitoring and brain mapping under stimulation. The images of 10 patients and 30 controls were spatially normalized to templates generated in-house by non-rigid registration and the standardized images of the patients and controls were statistically compared. Epileptic focus candidates were visualized on a color map of axial images of each template and the focus site was identified in candidates for lobar location. In patients with Engel I postoperative seizure outcomes we assessed the sensitivity and specificity of the imaging methods for lobar focus localization. We also compared the concordance scores of patients with Engel I and Engel II-IV postoperative seizures. The sensitivity and specificity for lobar focus localization on 18F-FDG PET scans was 90.0% and 84.8%, respectively; it was 30.0% and 81.4% for 11C-FMZ PET, 40.0% and 66.7% for 11C-FMZ BP images, and 100.0% and 51.4% for 18F-FDG PET/11C-FMZ PET/11C-FMZ BP images. In one patient the epileptic focus not detected on 18F-FDG PET scans was shown on 11C-FMZ BP images. In patients with Engel I post-treatment seizures the concordance scores were significantly higher for 18F-FDG PET than 11C-FMZ PET and 11C-FMZ BP images (p < 0.05). With respect to sensitivity and specificity, 18F-FDG PET was superior to 11C-FMZ PET and 11C-FMZ BP imaging. However, in some patients with normal MRI results, 11C-FMZ BP studies may complement 18F-FDG PET findings in efforts to identify the epileptogenic lobar regions.


  • Clinical utility of gadoxetate disodium-enhanced hepatic MRI for stereotactic body radiotherapy of hepatocellular carcinoma

    by Yuko Nakamura, Tomoki Kimura, Toru Higaki, Yukiko Honda, Daisuke Komoto, Takuji Yamagami, Makoto Iida, Yasushi Nagata, Yohji Honda, Hiroshi Aikata, et al.

    Purpose To investigate the utility of gadoxetate disodium-enhanced hepatic MRI (EOB-MRI) for stereotactic body radiotherapy (SBRT) to treat hepatocellular carcinoma (HCC). Materials and methods We divided 30 HCC patients who underwent SBRT into group A (no change in their Child-Pugh score 6 months post-SBRT) and group B (increased score 6 months post-SBRT). EOB-MRI was performed before and 6 months after SBRT. We calculated the liver-spleen contrast (LSC) ratio for each radiation dose area on hepatobiliary phase scans (LSCbefore using images obtained before SBRT and LSCafter using images acquired after SBRT) and the weighted LSC (W-LSC) as: [(mean LSCbefore (0–30 Gy) × liver volume (0–30 Gy) + mean LSCbefore (30 Gy-) × liver volume (30 Gy-))/total liver volume]. Then we compared the W-LSC, percentage of the liver volume exposed to >20 Gy (V20), and mean liver dose in the two groups. Results The LSCafter at 48, 40, and 30 Gy to the liver was statistically lower than the unirradiated area of the liver (p < 0.01). Univariate analysis showed that only W-LSC was significantly associated with group B (p = 0.02). Conclusion W-LSC was a useful parameter for predicting changes in hepatic function after SBRT.


  • Non-occlusive mesenteric ischemia (NOMI): utility of measuring the diameters of the superior mesenteric artery and superior mesenteric vein at multidetector CT

    by Yuko Nakamura, Masaki Urashima, Naoyuki Toyota, Chiaki Ono, Makoto Iida, Wataru Fukumoto, Yoko Kaichi, Chihiro Tani, Yukiko Honda, Daisuke Komoto, et al.

    Objective To investigate the diagnostic capability of multidetector computed tomography for detecting non-occlusive mesenteric ischemia (NOMI). Methods We studied 11 NOMI patients and 44 controls. Radiologists evaluated the CT images for the presence of bowel ischemia and measured the diameters of the superior mesenteric artery and the superior mesenteric vein (D SMA and D SMV). We also performed linear discriminant analysis (LDA) using D SMA and D SMV. Results All NOMI patients presented with more than 2 CT findings of bowel ischemia. D SMA and D SMV were significantly smaller in NOMI patients than in the controls (p < 0.01). At the optimal cut-off values for D SMA (6.5 mm), D SMV (9.0 mm), and the Z value in LDA (0.93), sensitivity and specificity were 81.8 and 81.8; 81.8 and 88.6; and 81.8 and 97.7 %, respectively. Conclusions D SMA and D SMV were significantly smaller in NOMI patients than in the controls and D SMV is a more significant parameter than D SMA.