Olga V. Petrauskene
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Olga V. Petrauskene has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Manohar R. Furtado
Life Technologies Corporation, Foster City, California, United States of America
4 shared publications - Robert S. Tebbs
Applied Biosystems, 850 Lincoln Centre Dr, Foster City, CA 94404)
3 shared publications - Lily Y Wong
Applied Biosystems, 850 Lincoln Centre Dr, Foster City, CA 94404)
2 shared publications - Priya Balachandran
Applied Biosystems, 850 Lincoln Centre Dr, Foster City, CA 94404)
2 shared publications Catherine Fearnley
1 shared publication- Craig A Cummings
Life Technologies Corporation, 850 Lincoln Centre Drive, Foster City CA, 94404, USA
1 shared publication
Latest Publications
- 1 May 2013
- Published by Oxford University Press (OUP)
- Vol. 96 (3) , 542-551
MicroSEQ®Listeria monocytogenes Detection Kit
The Applied Biosystems Performance Tested MethodSM for detecting Listeria monocytogenes in food and environmental samples was compared to the Health Canada reference method (MFHPB-30) for the analysis of five ready-to-eat (RTE) meats (deli turkey, hot dogs, liver paté, deli ham, and raw fermented sausage) and a stainless steel environmental surface. The MicroSEQ® method includes the MicroSEQListeria monocytogenes Detection Kit and the option of two different sample preparation kits, either the automated high-throughput PrepSEQ™ Nucleic Acid Extraction Kit or the manual low- to mid-throughput PrepSEQ Rapid Spin Sample Preparation Kit. For each sample matrix, 20 replicates were analyzed at two inoculum levels: for RTE meats, a low-level inoculum at 0.2–2 CFU/25 g and a high-level inoculum at 2–5 CFU/25 g; and for environmental surfaces, a low-level inoculum at 0.2–2 CFU/5 cm2 sampling area and a high-level inoculum at 2–5 CFU/5 cm2 sampling area. Five control replicates were also analyzed at 0 CFU/25 g (uninoculated) for food or 0 CFU/5 cm2 sampling area for environmental surface. Both sample preparation methods returned identical results. There was no statistically significant difference in the number of positive samples detected by the MicroSEQ Listeria monocytogenes method and the MFHPB-30 reference method for four of the five RTE meats and the one stainless steel surface tested. For deli turkey, there was a statistically significant difference in the number of positive results detected by the MicroSEQ method and the Health Canada MFHPB-30 reference method for the low inoculation level, with the MicroSEQ method detecting more positives. Because the MicroSEQ method uses real-time PCR to detect pathogens, it provides faster time-to-results compared to culture methods while at the same time demonstrating equivalent detection. The MicroSEQ method detects L. monocytogenes within 2 to 3 h following 24 to 28 h enrichment compared to culture methods that take at least 5 days for presumptive positive results.
- 1 May 2013
- Published by Oxford University Press (OUP)
- Vol. 96 (3) , 542-551
MicroSEQ®Listeria monocytogenes Detection Kit
The Applied Biosystems Performance Tested MethodSM for detecting Listeria monocytogenes in food and environmental samples was compared to the Health Canada reference method (MFHPB-30) for the analysis of five ready-to-eat (RTE) meats (deli turkey, hot dogs, liver paté, deli ham, and raw fermented sausage) and a stainless steel environmental surface. The MicroSEQ® method includes the MicroSEQListeria monocytogenes Detection Kit and the option of two different sample preparation kits, either the automated high-throughput PrepSEQ™ Nucleic Acid Extraction Kit or the manual low- to mid-throughput PrepSEQ Rapid Spin Sample Preparation Kit. For each sample matrix, 20 replicates were analyzed at two inoculum levels: for RTE meats, a low-level inoculum at 0.2–2 CFU/25 g and a high-level inoculum at 2–5 CFU/25 g; and for environmental surfaces, a low-level inoculum at 0.2–2 CFU/5 cm2 sampling area and a high-level inoculum at 2–5 CFU/5 cm2 sampling area. Five control replicates were also analyzed at 0 CFU/25 g (uninoculated) for food or 0 CFU/5 cm2 sampling area for environmental surface. Both sample preparation methods returned identical results. There was no statistically significant difference in the number of positive samples detected by the MicroSEQ Listeria monocytogenes method and the MFHPB-30 reference method for four of the five RTE meats and the one stainless steel surface tested. For deli turkey, there was a statistically significant difference in the number of positive results detected by the MicroSEQ method and the Health Canada MFHPB-30 reference method for the low inoculation level, with the MicroSEQ method detecting more positives. Because the MicroSEQ method uses real-time PCR to detect pathogens, it provides faster time-to-results compared to culture methods while at the same time demonstrating equivalent detection. The MicroSEQ method detects L. monocytogenes within 2 to 3 h following 24 to 28 h enrichment compared to culture methods that take at least 5 days for presumptive positive results.
- 1 September 2011
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 94 (5) , 1481-1489
Evaluation of Applied Biosystems MicroSEQ® Real-Time PCR System for Detection of Listeria monocytogenes in Food
Increasingly, more food companies are relying on molecular methods, such as PCR, for pathogen detection due to their improved simplicity, sensitivity, and rapid time to results. this report describes the validation of a new Real-time PCR method to detect Listeria monocytogenes in nine different food matrixes. the complete system consists of the MicroSEQ® L. monocytogenes Detection Kit, sample preparation, the Applied Biosystems 7500 Fast Real-time PCR instrument, and RapidFinder™ Express software. two sample preparation methods were validated: the PrepSEQ® Nucleic Acid extraction kit and the PrepSEQ Rapid Spin sample preparation kit. the test method was compared to the ISO 11290-1 reference method using an unpaired-study design to detect L. monocytogenes in roast beef, cured bacon, lox (smoked salmon), lettuce, whole cow's milk, dry infant formula, ice cream, salad dressing, and mayonnaise. the MicroSEQ L. monocytogenes Detection Kit and the ISO 11290-1 reference method showed equivalent detection based on Chi-square analysis for all food matrixes when the samples were prepared using either of the two sample preparation methods. An independent validation confirmed these findings on smoked salmon and whole cow's milk. the MicroSEQ kit detected all 50 L. monocytogenes strains tested, and none of the 30 nontargeted bacteria strains.
- 1 September 2011
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 94 (5) , 1481-1489
Evaluation of Applied Biosystems MicroSEQ® Real-Time PCR System for Detection of Listeria monocytogenes in Food
Increasingly, more food companies are relying on molecular methods, such as PCR, for pathogen detection due to their improved simplicity, sensitivity, and rapid time to results. this report describes the validation of a new Real-time PCR method to detect Listeria monocytogenes in nine different food matrixes. the complete system consists of the MicroSEQ® L. monocytogenes Detection Kit, sample preparation, the Applied Biosystems 7500 Fast Real-time PCR instrument, and RapidFinder™ Express software. two sample preparation methods were validated: the PrepSEQ® Nucleic Acid extraction kit and the PrepSEQ Rapid Spin sample preparation kit. the test method was compared to the ISO 11290-1 reference method using an unpaired-study design to detect L. monocytogenes in roast beef, cured bacon, lox (smoked salmon), lettuce, whole cow's milk, dry infant formula, ice cream, salad dressing, and mayonnaise. the MicroSEQ L. monocytogenes Detection Kit and the ISO 11290-1 reference method showed equivalent detection based on Chi-square analysis for all food matrixes when the samples were prepared using either of the two sample preparation methods. An independent validation confirmed these findings on smoked salmon and whole cow's milk. the MicroSEQ kit detected all 50 L. monocytogenes strains tested, and none of the 30 nontargeted bacteria strains.
- 1 June 2011
- Published by Elsevier in Journal of Food Protection
- Vol. 74 (6) , 939-948
Design and Validation of a Novel Multiplex Real-Time PCR Assay for Vibrio Pathogen Detection
Three species--Vibrio cholerae, Vibrio parahaemolyticus, and Vibrio vulnificus--account for the majority of vibrio infections in humans. Rapid and accurate identification of Vibrio species has been problematic because phenotypic characteristics are variable within species. Additionally, biochemical identification and confirmation require 2 or more days to complete. Rapid and sensitive molecular techniques for the detection of vibrio pathogens would be useful for the surveillance and management of outbreaks. To facilitate the identification of human-pathogenic species, we designed and validated a highly sensitive, specific, and robust multiplex real-time PCR assay to identify V. cholerae, V. parahaemolyticus, and V. vulnificus using a four-dye configuration in a convenient lyophilized format. Multiple Vibrio strains were sequenced to verify candidate target TaqMan sites. Several individual assays within the multiplex contain multiple primers or probes to ensure detection of polymorphic variants. V. cholerae, V. parahaemolyticus, and V. vulnificus were detected either individually or in mixtures at ≤30 genomic copies. V. cholerae was specifically detected in the presence or absence of Vibrio mimicus. The Vibrio multiplex assay showed 100% specificity to all targets analyzed and no detection of nearest neighbor strains. Each assay exhibited 100% ± 10% efficiency. Multiplex real-time PCR can simplify pathogen detection and reduce costs per test since three species can be analyzed in a single reaction tube. Rapid and accurate detection of pathogenic vibrios in shellfish or seawater samples will improve the microbiological safety of seafood for consumers.
- 1 June 2011
- Published by Elsevier in Journal of Food Protection
- Vol. 74 (6) , 939-948
Design and Validation of a Novel Multiplex Real-Time PCR Assay for Vibrio Pathogen Detection
Three species--Vibrio cholerae, Vibrio parahaemolyticus, and Vibrio vulnificus--account for the majority of vibrio infections in humans. Rapid and accurate identification of Vibrio species has been problematic because phenotypic characteristics are variable within species. Additionally, biochemical identification and confirmation require 2 or more days to complete. Rapid and sensitive molecular techniques for the detection of vibrio pathogens would be useful for the surveillance and management of outbreaks. To facilitate the identification of human-pathogenic species, we designed and validated a highly sensitive, specific, and robust multiplex real-time PCR assay to identify V. cholerae, V. parahaemolyticus, and V. vulnificus using a four-dye configuration in a convenient lyophilized format. Multiple Vibrio strains were sequenced to verify candidate target TaqMan sites. Several individual assays within the multiplex contain multiple primers or probes to ensure detection of polymorphic variants. V. cholerae, V. parahaemolyticus, and V. vulnificus were detected either individually or in mixtures at ≤30 genomic copies. V. cholerae was specifically detected in the presence or absence of Vibrio mimicus. The Vibrio multiplex assay showed 100% specificity to all targets analyzed and no detection of nearest neighbor strains. Each assay exhibited 100% ± 10% efficiency. Multiplex real-time PCR can simplify pathogen detection and reduce costs per test since three species can be analyzed in a single reaction tube. Rapid and accurate detection of pathogenic vibrios in shellfish or seawater samples will improve the microbiological safety of seafood for consumers.
- Open Access
- 2 December 2010
- Published by Springer Nature in BMC Genomics
- Vol. 11 (1) , 688
Comparative genomics of the bacterial genus Listeria: Genome evolution is characterized by limited gene acquisition and limited gene loss
The bacterial genus Listeria contains pathogenic and non-pathogenic species, including the pathogens L. monocytogenes and L. ivanovii, both of which carry homologous virulence gene clusters such as the prfA cluster and clusters of internalin genes. Initial evidence for multiple deletions of the prfA cluster during the evolution of Listeria indicates that this genus provides an interesting model for studying the evolution of virulence and also presents practical challenges with regard to definition of pathogenic strains.
- 2 December 2010
- Published by Springer Nature in BMC Genomics
- Vol. 11 (1) , 688
Open AccessComparative genomics of the bacterial genus Listeria: Genome evolution is characterized by limited gene acquisition and limited gene loss
The bacterial genus Listeria contains pathogenic and non-pathogenic species, including the pathogens L. monocytogenes and L. ivanovii, both of which carry homologous virulence gene clusters such as the prfA cluster and clusters of internalin genes. Initial evidence for multiple deletions of the prfA cluster during the evolution of Listeria indicates that this genus provides an interesting model for studying the evolution of virulence and also presents practical challenges with regard to definition of pathogenic strains.
- 1 March 2010
- Published by American Association of Avian Pathologists (AAAP) in Avian Diseases Digest
- Vol. 5 (s1) , e164-e165
New Highly Sensitive and Accurate Lyophilized Real-Time RT-PCR Tests for Early Detection of Avian Influenza
- 1 March 2010
- Published by American Association of Avian Pathologists (AAAP) in Avian Diseases Digest
- Vol. 5 (s1) , e164-e165
New Highly Sensitive and Accurate Lyophilized Real-Time RT-PCR Tests for Early Detection of Avian Influenza
- 20 February 2010
- Vol. 92 (6) , 1895-901
TaqMan Salmonella enterica Detection Kit. Performance Tested Method 020803.
Peanut butter spiked with Salmonella enterica ser. Typhimurium was prepared by an independent laboratory and sent to Applied Biosystems to determine the sensitivity and specificity of the TaqMan Salmonella enterica Detection Kit for detecting Salmonella in peanut butter. The samples were spiked at three levels: five no-spike (0 CFU/25 g); 20 low-spike (0.2 CFU/25 g); and 20 high-spike (2 CFU/25 g). They were coded to create a blind set of 45 samples. The samples were processed based on an unpaired test design that included enrichment in buffered peptone water for the candidate method and lactose broth for the reference method. In the candidate method, a 1 mL aliquot of enriched sample was extracted using PrepMan Ultra Sample Preparation Reagent; the sample was amplified on the Applied Biosystems 7500 real-time PCR system, and analyzed for detection of Salmonella using RapidFinder Version 1.0 software. All samples processed by the candidate method were confirmed by culture according to the U.S. Food and Drug Administration's Bacteriological Analytical Manual procedures. Sensitivity, specificity, and Chi-square analysis were calculated by combining candidate method results with those of the reference method that were collected by the independent laboratory. The TaqMan Salmonella enterica Detection Kit showed 40% sensitivity, 100% specificity, and a Chi-square value equal to 1.52. Chi-square analysis indicated the candidate method and the reference method were comparable. Although the candidate method sensitivity was only 40% when compared with the reference method (unpaired samples), the sensitivity was > 100% when the candidate method results were compared with those of the confirmation method (same sample enrichment).
- 20 February 2010
- Vol. 92 (6) , 1895-901
TaqMan Salmonella enterica Detection Kit. Performance Tested Method 020803.
Peanut butter spiked with Salmonella enterica ser. Typhimurium was prepared by an independent laboratory and sent to Applied Biosystems to determine the sensitivity and specificity of the TaqMan Salmonella enterica Detection Kit for detecting Salmonella in peanut butter. The samples were spiked at three levels: five no-spike (0 CFU/25 g); 20 low-spike (0.2 CFU/25 g); and 20 high-spike (2 CFU/25 g). They were coded to create a blind set of 45 samples. The samples were processed based on an unpaired test design that included enrichment in buffered peptone water for the candidate method and lactose broth for the reference method. In the candidate method, a 1 mL aliquot of enriched sample was extracted using PrepMan Ultra Sample Preparation Reagent; the sample was amplified on the Applied Biosystems 7500 real-time PCR system, and analyzed for detection of Salmonella using RapidFinder Version 1.0 software. All samples processed by the candidate method were confirmed by culture according to the U.S. Food and Drug Administration's Bacteriological Analytical Manual procedures. Sensitivity, specificity, and Chi-square analysis were calculated by combining candidate method results with those of the reference method that were collected by the independent laboratory. The TaqMan Salmonella enterica Detection Kit showed 40% sensitivity, 100% specificity, and a Chi-square value equal to 1.52. Chi-square analysis indicated the candidate method and the reference method were comparable. Although the candidate method sensitivity was only 40% when compared with the reference method (unpaired samples), the sensitivity was > 100% when the candidate method results were compared with those of the confirmation method (same sample enrichment).