Don Calogero
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Don Calogero has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Gene Hilmantel
3 shared publications- Malvina B. Eydelman
Office of Device Evaluation, Centers for Devices and Radiological Health, Food and Drug Administration, Silver Spring, Maryland
3 shared publications - Bennett N. Walker
Office of Device Evaluation, Center for Devices and Radiological Health, U.S. Food and Drug Administration;
2 shared publications - Ilko. K. Ilev
Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, MD, USA
2 shared publications Robert H. James
From the Optical Therapeutics and Medical Nanophotonics (Walker, James, Song, Ilev), Office of Science and Engineering Laboratories, and the Office of Device Evaluation (Walker, Calogero), Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, Maryland, USA
2 shared publicationsShelley Y. Buchen
2 shared publications
Latest Publications
- 1 March 2016
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 42 (3) , 455-461
Confocal laser method for quantitative evaluation of critical optical properties of toric intraocular lenses
Purpose To present a proof-of-concept study on the development and implementation of an innovative confocal laser method platform for precise quantitative evaluation of critical optical properties unique to toric intraocular lenses (IOLs). Setting U.S. Food and Drug Administration, Optical Therapeutics and Medical Nanophotonics Laboratory, Silver Spring, Maryland, USA. Design Experimental study. Methods The optical properties of hydrophobic toric IOLs were evaluated with a confocal laser method that was modified to isolate the 2 planes of focus that are observed with toric IOLs. Results The results show the confocal laser method has the potential to measure the orthogonally separated optical powers and then calculate them to the commonly referenced spherical equivalent and cylinder powers of toric IOLs with high accuracy (≤1 μm of focal length measurement). Furthermore, the proposed confocal laser method design includes a new component for precise differentiation of the 2 focal planes and isolation of the 2 focal points, and thus for accurate measurement of the anterior cylinder axis of toric IOLs. Conclusion The modifications to the confocal laser method platform enabled the quantitative evaluation of optical properties attributed to toric IOLs. Financial Disclosure None of the authors has a financial or proprietary interest in any material or method mentioned.
- 1 March 2016
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 42 (3) , 455-461
Confocal laser method for quantitative evaluation of critical optical properties of toric intraocular lenses
Purpose To present a proof-of-concept study on the development and implementation of an innovative confocal laser method platform for precise quantitative evaluation of critical optical properties unique to toric intraocular lenses (IOLs). Setting U.S. Food and Drug Administration, Optical Therapeutics and Medical Nanophotonics Laboratory, Silver Spring, Maryland, USA. Design Experimental study. Methods The optical properties of hydrophobic toric IOLs were evaluated with a confocal laser method that was modified to isolate the 2 planes of focus that are observed with toric IOLs. Results The results show the confocal laser method has the potential to measure the orthogonally separated optical powers and then calculate them to the commonly referenced spherical equivalent and cylinder powers of toric IOLs with high accuracy (≤1 μm of focal length measurement). Furthermore, the proposed confocal laser method design includes a new component for precise differentiation of the 2 focal planes and isolation of the 2 focal points, and thus for accurate measurement of the anterior cylinder axis of toric IOLs. Conclusion The modifications to the confocal laser method platform enabled the quantitative evaluation of optical properties attributed to toric IOLs. Financial Disclosure None of the authors has a financial or proprietary interest in any material or method mentioned.
- Open Access
- 17 August 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 7 (4) , 1-7
Quantifying the Multiwavelength Dispersion Effect on Dioptric Power Measurement of Intraocular Lenses
Improving technology and high demand has prompted a rapidly evolving intraocular lens (IOL) industry. To keep up with the improved designs, optical property evaluation techniques need to be adapted quickly to ensure IOL safety and efficacy. Identifying critical parameters are essential in evaluating IOL optical properties, which include temperature, medium, and test light characteristics. Here, we present a novel preclinical quantitative study of the dispersion effect that the wavelength of exposed test light has on IOL optical properties, specifically dioptric power. Dioptric power levels of IOLs were measured using a confocal laser method (CLM) when exposed to various wavelengths throughout the visible spectrum. Results showed statistically significant yet minimal focal point shift and, therefore, dioptric power changes ( $\sim$0.15D) due to the effect of test light wavelength, similar to known wavelength-dependent relationships associated with changes in refractive index. Further evaluation of critical parameters can lead to an improvement of IOL product designs and overall public health.
- 17 August 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 7 (4) , 1-7
Open AccessQuantifying the Multiwavelength Dispersion Effect on Dioptric Power Measurement of Intraocular Lenses
Improving technology and high demand has prompted a rapidly evolving intraocular lens (IOL) industry. To keep up with the improved designs, optical property evaluation techniques need to be adapted quickly to ensure IOL safety and efficacy. Identifying critical parameters are essential in evaluating IOL optical properties, which include temperature, medium, and test light characteristics. Here, we present a novel preclinical quantitative study of the dispersion effect that the wavelength of exposed test light has on IOL optical properties, specifically dioptric power. Dioptric power levels of IOLs were measured using a confocal laser method (CLM) when exposed to various wavelengths throughout the visible spectrum. Results showed statistically significant yet minimal focal point shift and, therefore, dioptric power changes ( $\sim$0.15D) due to the effect of test light wavelength, similar to known wavelength-dependent relationships associated with changes in refractive index. Further evaluation of critical parameters can lead to an improvement of IOL product designs and overall public health.
- 31 July 2012
- Published by Elsevier in Ophthalmology
- Vol. 119 (7) , e30-e35
An Investigation of Enzymatic Detergents as a Potential Cause of Toxic Anterior Segment Syndrome
- 31 July 2012
- Published by Elsevier in Ophthalmology
- Vol. 119 (7) , e30-e35
An Investigation of Enzymatic Detergents as a Potential Cause of Toxic Anterior Segment Syndrome
- 31 July 2012
- Published by Elsevier in Ophthalmology
- Vol. 119 (7) , e24-e29
Evaluation of Intraocular Reactivity to Organic Contaminants of Ophthalmic Devices in a Rabbit Model
- 31 July 2012
- Published by Elsevier in Ophthalmology
- Vol. 119 (7) , e24-e29
Evaluation of Intraocular Reactivity to Organic Contaminants of Ophthalmic Devices in a Rabbit Model
- 1 May 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
A Novel Confocal Fiber-Optic Laser Method for Exact Intraocular Lens Dioptric Power Measurement
Based on a fiber-optic confocal design, we have developed a simple, accurate, objective and quick method for exact focal length measurement of both positive and negative intraocular lenses providing a spatial resolution exceeding 1 μm.
- 1 May 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
A Novel Confocal Fiber-Optic Laser Method for Exact Intraocular Lens Dioptric Power Measurement
Based on a fiber-optic confocal design, we have developed a simple, accurate, objective and quick method for exact focal length measurement of both positive and negative intraocular lenses providing a spatial resolution exceeding 1 μm.