Xian-Hua Cai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Xian-Hua Cai has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
Feng Xu
2 shared publicationsHui Kang
Department of Orthopaedics, Wuhan General Hospital of Guangzhou Command of PLA, Wuhan, China
2 shared publicationsJi-Feng Huang
2 shared publicationsWei-Bing Huang
Wuhan General Hospital of Guangzhou Command
2 shared publications- Zhihua Wang
Institute of Applied Mechanics College of Aeronautics and Astronautics Taiyuan University of Technology 030024 Taiyuan China
2 shared publications - Bao-Cheng Zhang
Department of Orthopaedics, General Hospital of Central Theater Command of PLA, Wuhan 430070, China
1 shared publication
Latest Publications
- 15 April 2016
- Published by Wolters Kluwer Health in Spine
- Vol. 41 (8) , E459-E466
Biomechanical Comparison of Modified TARP Technique Versus Modified Goel Technique for the Treatment of Basilar Invagination
Study Design. A finite element analysis. Objective. The aim of this study was to determine the biomechanical differences between atlantoaxial fusion cage combined with transoral atlantoaxial reduction plate fixation (TARP + Cage, modified TARP technique) and that combined with C1 lateral mass screw and C2 pedicle screw fixation (C1LS + C2PS + Cage, modified Goel technique) in the treatment of basilar invagination (BI) by finite element analysis. Summary of Background Data. Clinical studies have shown that transoral anterior atlantoaxial release followed by TARP fixation can achieve reduction, decompression, fixation, and fusion of C1–C2 through a transoral-only approach. Although cage has been used to reduce the BI through posterior approach, there are no studies referred to the cage combined with TARP for C1–C2 fusion. Methods. A finite element model was used to investigate and compare the stability between TARP + Cage fixation and C1LS + C2PS + Cage fixation in the treatment of BI. Vertical load of 40 N was applied on the C0, to simulate head weight, and 1.5 Nm torque was applied to the C0 to simulate flexion, extension, lateral bending, and rotation. Results. In comparison with the C1LS + C2PS + Cage model, the TARP + Cage model reduced the ROM by 44.7%, 30.0%, and 10.5% in extension, lateral bending, and axial rotation, while the TARP + Cage model increased the ROM by 30.0% in flexion, and the TARP + Cage model also led to lower screw stress in all motions with one exception (anterior C2PS stress in extension). Conclusion. Our results indicate that the TARP + Cage fixation may offer higher stability to C1LS + C2PS + Cage in extension, lateral bending, and axial rotation but lower stability in flexion. Compared with modified Goel technique, the modified TARP technique not only has the capability of transferring the load and distributing the stress but also can provide neural decompression, stabilization and fusion, and restore C1–C2 normal fusion angle. Level of Evidence: N/A
- 15 April 2016
- Published by Wolters Kluwer Health in Spine
- Vol. 41 (8) , E459-E466
Biomechanical Comparison of Modified TARP Technique Versus Modified Goel Technique for the Treatment of Basilar Invagination
Study Design. A finite element analysis. Objective. The aim of this study was to determine the biomechanical differences between atlantoaxial fusion cage combined with transoral atlantoaxial reduction plate fixation (TARP + Cage, modified TARP technique) and that combined with C1 lateral mass screw and C2 pedicle screw fixation (C1LS + C2PS + Cage, modified Goel technique) in the treatment of basilar invagination (BI) by finite element analysis. Summary of Background Data. Clinical studies have shown that transoral anterior atlantoaxial release followed by TARP fixation can achieve reduction, decompression, fixation, and fusion of C1–C2 through a transoral-only approach. Although cage has been used to reduce the BI through posterior approach, there are no studies referred to the cage combined with TARP for C1–C2 fusion. Methods. A finite element model was used to investigate and compare the stability between TARP + Cage fixation and C1LS + C2PS + Cage fixation in the treatment of BI. Vertical load of 40 N was applied on the C0, to simulate head weight, and 1.5 Nm torque was applied to the C0 to simulate flexion, extension, lateral bending, and rotation. Results. In comparison with the C1LS + C2PS + Cage model, the TARP + Cage model reduced the ROM by 44.7%, 30.0%, and 10.5% in extension, lateral bending, and axial rotation, while the TARP + Cage model increased the ROM by 30.0% in flexion, and the TARP + Cage model also led to lower screw stress in all motions with one exception (anterior C2PS stress in extension). Conclusion. Our results indicate that the TARP + Cage fixation may offer higher stability to C1LS + C2PS + Cage in extension, lateral bending, and axial rotation but lower stability in flexion. Compared with modified Goel technique, the modified TARP technique not only has the capability of transferring the load and distributing the stress but also can provide neural decompression, stabilization and fusion, and restore C1–C2 normal fusion angle. Level of Evidence: N/A
- Open Access
- 22 September 2015
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 16 (1) , 1-11
Biomechanical comparison of a novel transoral atlantoaxial anchored cage with established fixation technique - a finite element analysis
The transoral atlantoaxial reduction plate (TARP) fixation has been introduced to achieve reduction, decompression, fixation and fusion of C1–C2 through a transoral-only approach. However, it may also be associated with potential disadvantages, including dysphagia and load shielding of the bone graft. To prevent potential disadvantages related to TARP fixation, a novel transoral atlantoaxial fusion cage with integrated plate (Cage + Plate) device for stabilization of the C1-C2 segment is designed. The aims of the present study were to compare the biomechanical differences between Cage + Plate device and Cage + TARP device for the treatment of basilar invagination (BI) with irreducible atlantoaxial dislocation (IAAD). A detailed, nonlinear finite element model (FEM) of the intact upper cervical spine had been developed and validated. Then a FEM of an unstable BI model treated with Cage + Plate fixation, was compared to that with Cage + TARP fixation. All models were subjected to vertical load with pure moments in flexion, extension, lateral bending and axial rotation. Range of motion (ROM) of C1-C2 segment and maximum von Mises Stress of the C2 endplate and bone graft were quantified for the two devices. Both devices significantly reduced ROM compared with the intact state. In comparison with the Cage + Plate model, the Cage + TARP model reduced the ROM by 82.5 %, 46.2 %, 10.0 % and 74.3 % in flexion, extension, lateral bending, and axial rotation. The Cage + Plate model showed a higher increase stresses on C2 endplate and bone graft than the Cage + TARP model in all motions. Our results indicate that the novel Cage + Plate device may provide lower biomechanical stability than the Cage + TARP device in flexion, extension, and axial rotation, however, it may reduce stress shielding of the bone graft for successful fusion and minimize the risk of postoperative dysphagia. Clinical trials are now required to validate the reproducibility and advantages of our findings using this anchored cage for the treatment of BI with IAAD.
- 22 September 2015
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 16 (1) , 1-11
Open AccessBiomechanical comparison of a novel transoral atlantoaxial anchored cage with established fixation technique - a finite element analysis
The transoral atlantoaxial reduction plate (TARP) fixation has been introduced to achieve reduction, decompression, fixation and fusion of C1–C2 through a transoral-only approach. However, it may also be associated with potential disadvantages, including dysphagia and load shielding of the bone graft. To prevent potential disadvantages related to TARP fixation, a novel transoral atlantoaxial fusion cage with integrated plate (Cage + Plate) device for stabilization of the C1-C2 segment is designed. The aims of the present study were to compare the biomechanical differences between Cage + Plate device and Cage + TARP device for the treatment of basilar invagination (BI) with irreducible atlantoaxial dislocation (IAAD). A detailed, nonlinear finite element model (FEM) of the intact upper cervical spine had been developed and validated. Then a FEM of an unstable BI model treated with Cage + Plate fixation, was compared to that with Cage + TARP fixation. All models were subjected to vertical load with pure moments in flexion, extension, lateral bending and axial rotation. Range of motion (ROM) of C1-C2 segment and maximum von Mises Stress of the C2 endplate and bone graft were quantified for the two devices. Both devices significantly reduced ROM compared with the intact state. In comparison with the Cage + Plate model, the Cage + TARP model reduced the ROM by 82.5 %, 46.2 %, 10.0 % and 74.3 % in flexion, extension, lateral bending, and axial rotation. The Cage + Plate model showed a higher increase stresses on C2 endplate and bone graft than the Cage + TARP model in all motions. Our results indicate that the novel Cage + Plate device may provide lower biomechanical stability than the Cage + TARP device in flexion, extension, and axial rotation, however, it may reduce stress shielding of the bone graft for successful fusion and minimize the risk of postoperative dysphagia. Clinical trials are now required to validate the reproducibility and advantages of our findings using this anchored cage for the treatment of BI with IAAD.
- 3 July 2013
- Published by Springer Nature in European Spine Journal
- Vol. 22 (12) , 2686-2694
Evaluation of biomechanical properties of anterior atlantoaxial transarticular locking plate system using three-dimensional finite element analysis
To evaluate a new anterior atlantoaxial transarticular locking plate system using finite element analysis. Thin-section spiral computed tomography was performed from occiput to C2 region. A finite element model of an unstable atlantoaxial joint, treated with an anterior atlantoaxial transarticular locking plate system, was compared with the simple anterior atlantoaxial transarticular screw system. Flexion, extension, lateral bending, and axial rotation were imposed on the model. Displacement of the atlantoaxial transarticular screw and stress at the screw–bone interface were observed for the two internal fixation systems. Screw displacement was less using the anterior atlantoaxial transarticular locking plate system compared to simple anterior atlantoaxial transarticular screw fixation under various conditions, and stability increased especially during flexion and extension. The anterior atlantoaxial transarticular locking plate system not only provided stronger fixation, but also decreased screw-bearing stress and screw–bone interface stress compared to simple anterior atlantoaxial transarticular screw fixation.
- 3 July 2013
- Published by Springer Nature in European Spine Journal
- Vol. 22 (12) , 2686-2694
Evaluation of biomechanical properties of anterior atlantoaxial transarticular locking plate system using three-dimensional finite element analysis
To evaluate a new anterior atlantoaxial transarticular locking plate system using finite element analysis. Thin-section spiral computed tomography was performed from occiput to C2 region. A finite element model of an unstable atlantoaxial joint, treated with an anterior atlantoaxial transarticular locking plate system, was compared with the simple anterior atlantoaxial transarticular screw system. Flexion, extension, lateral bending, and axial rotation were imposed on the model. Displacement of the atlantoaxial transarticular screw and stress at the screw–bone interface were observed for the two internal fixation systems. Screw displacement was less using the anterior atlantoaxial transarticular locking plate system compared to simple anterior atlantoaxial transarticular screw fixation under various conditions, and stability increased especially during flexion and extension. The anterior atlantoaxial transarticular locking plate system not only provided stronger fixation, but also decreased screw-bearing stress and screw–bone interface stress compared to simple anterior atlantoaxial transarticular screw fixation.
- 1 July 2013
- Vol. 26 (7) , 572-7
[Surgical strategy for upper cervical vertebrae instability through the anterior approach].
To explore the choice and effect of internal fixation in treating upper cervical vertebrae instability through anterior approach. From March 2000 to September 2010,83 patients with upper cervical vertebrae instability were treated with internal fixation through anterior approach. There were 59 males and 24 females with a mean age of 42 years old (ranged, 20 to 68). Among these patients, 36 patients were treated with odontoid screw fixation, 16 patients with C1,2 transarticular screw fixation, 23 patients with C2,3 steel plate fixation, 5 patients with odontoid screw and transarticular screw fixation,2 patients with odontoid screw and C2.3 steel plate fixation, 1 patient with C1,2 transarticular screw and C2,3 steel plate fixation. One patient with completely cervical vertebrae cord injury died of pulmonary infection after C1,2 transarticular screw fixation. Other patients were followed up from 8 to 36 months with an average of 15 months. Upper cervical vertebrae stability were restored without vertebral artery and spinal cord injury. Thirty-six patients were treated with odontoid screw fixation and 5 patients were treated with screw combined with transarticular screw fixation obtained bone union in the dentations without bone graft. Among the 16 patients treated with C1,2 transarticular screw fixation, 13 patients obtained bone union after bone graft; 1 patient died of pulmonary infection after surgery; 1 patient with comminuted odontoid fracture of type II C and atlantoaxial anterior dislocation did not obtain bone union after bone graft,but the fibrous healing was strong enough to maintain the atlantoaixal joint stability; 1 patient with obsolete atlantoaxial anterior dislocation were re-treated with Brooks stainless steel wire fixation and bone graft through posterior approach, and finally obtained bone union. It could obtain satisfactory effects depending on the difference of cervical vertebrae instability to choose the correctly surgical method.
- 1 July 2013
- Vol. 26 (7) , 572-7
[Surgical strategy for upper cervical vertebrae instability through the anterior approach].
To explore the choice and effect of internal fixation in treating upper cervical vertebrae instability through anterior approach. From March 2000 to September 2010,83 patients with upper cervical vertebrae instability were treated with internal fixation through anterior approach. There were 59 males and 24 females with a mean age of 42 years old (ranged, 20 to 68). Among these patients, 36 patients were treated with odontoid screw fixation, 16 patients with C1,2 transarticular screw fixation, 23 patients with C2,3 steel plate fixation, 5 patients with odontoid screw and transarticular screw fixation,2 patients with odontoid screw and C2.3 steel plate fixation, 1 patient with C1,2 transarticular screw and C2,3 steel plate fixation. One patient with completely cervical vertebrae cord injury died of pulmonary infection after C1,2 transarticular screw fixation. Other patients were followed up from 8 to 36 months with an average of 15 months. Upper cervical vertebrae stability were restored without vertebral artery and spinal cord injury. Thirty-six patients were treated with odontoid screw fixation and 5 patients were treated with screw combined with transarticular screw fixation obtained bone union in the dentations without bone graft. Among the 16 patients treated with C1,2 transarticular screw fixation, 13 patients obtained bone union after bone graft; 1 patient died of pulmonary infection after surgery; 1 patient with comminuted odontoid fracture of type II C and atlantoaxial anterior dislocation did not obtain bone union after bone graft,but the fibrous healing was strong enough to maintain the atlantoaixal joint stability; 1 patient with obsolete atlantoaxial anterior dislocation were re-treated with Brooks stainless steel wire fixation and bone graft through posterior approach, and finally obtained bone union. It could obtain satisfactory effects depending on the difference of cervical vertebrae instability to choose the correctly surgical method.
- 1 March 2012
- Vol. 50 (3) , 247-50
[Treatment strategy of rotatory dislocation of atlantoaxial articulation in children].
To analyze appropriate strategy about treatment of rotatory dislocation of atlantoaxial articulation in children. From March 2005 to February 2009, 36 patients with rotatory dislocation of atlantoaxial articulation were retrospectively analyzed, including 25 males and 11 females, with the average age of 7.8 years (ranged 3 - 14 years). According to Fielding-Hawkins clinical classification, type I 24 cases, type II 8 cases, type III 2 cases, type IV 2 cases. All of the patients were assessed rotatory dislocation of atlantoaxial articulation and whether or not upper cervical spine malformation by X-ray, MRI and CT scan and three-dimensional reconstruction. Thirty-two cases received observational treatments which were reduction after cervical traction, without appearance of the deformity, without neurological symptoms. And another 4 serious cases (irreducible atlantoaxial dislocation or with os odontoideum) received posterior atlantoaxial fixed autograft fusion. Rotation of atlas decreased from 16.0° ± 4.4° (range, 5° to 26°) pre-therapy to 4.5° ± 1.5° (range, 0° to 8°) post-therapy in 35 cases, rotation of atlas had significant difference between pre-therapy and post-therapy (t = 14.75, P < 0.05). One patient pre-therapy rotation of atlas was 45°, post-therapy was 4°. All patients were followed up for 14 - 38 months (mean, 18 months), 32 cases who received cervical traction and external fixation resulted in satisfactory outcome in which all the ankylodeire were disappear, bilateral masses were symmetrical on anterior-posterior and good functional activities of cervical. All the 4 cases surgically treated obtained reduction, sound bony fusion and neural symptoms were improved obviously after operation. Conservative treatment has been proved to be very effective in most of rotatory dislocation of atlantoaxial articulation in children. However, operative treatment should be considered in the following situations: irreducible atlantoaxial dislocation or patients with os odontoideum.
- 1 March 2012
- Vol. 50 (3) , 247-50
[Treatment strategy of rotatory dislocation of atlantoaxial articulation in children].
To analyze appropriate strategy about treatment of rotatory dislocation of atlantoaxial articulation in children. From March 2005 to February 2009, 36 patients with rotatory dislocation of atlantoaxial articulation were retrospectively analyzed, including 25 males and 11 females, with the average age of 7.8 years (ranged 3 - 14 years). According to Fielding-Hawkins clinical classification, type I 24 cases, type II 8 cases, type III 2 cases, type IV 2 cases. All of the patients were assessed rotatory dislocation of atlantoaxial articulation and whether or not upper cervical spine malformation by X-ray, MRI and CT scan and three-dimensional reconstruction. Thirty-two cases received observational treatments which were reduction after cervical traction, without appearance of the deformity, without neurological symptoms. And another 4 serious cases (irreducible atlantoaxial dislocation or with os odontoideum) received posterior atlantoaxial fixed autograft fusion. Rotation of atlas decreased from 16.0° ± 4.4° (range, 5° to 26°) pre-therapy to 4.5° ± 1.5° (range, 0° to 8°) post-therapy in 35 cases, rotation of atlas had significant difference between pre-therapy and post-therapy (t = 14.75, P < 0.05). One patient pre-therapy rotation of atlas was 45°, post-therapy was 4°. All patients were followed up for 14 - 38 months (mean, 18 months), 32 cases who received cervical traction and external fixation resulted in satisfactory outcome in which all the ankylodeire were disappear, bilateral masses were symmetrical on anterior-posterior and good functional activities of cervical. All the 4 cases surgically treated obtained reduction, sound bony fusion and neural symptoms were improved obviously after operation. Conservative treatment has been proved to be very effective in most of rotatory dislocation of atlantoaxial articulation in children. However, operative treatment should be considered in the following situations: irreducible atlantoaxial dislocation or patients with os odontoideum.
- 1 August 2011
- Vol. 24 (8) , 684-6
[Retrospective study on staged treatment of long bone shaft fractures with severe thoracic trauma].
To evaluate the feasibility and efficacy of staged treatment of patients with long bone shaft fractures and severe thoracic trauma. A retrospective study was performed on 41 patients with long bone shaft fractures and severe thoracic trauma who underwent staged treatment under the guidance of damage control orthopedics from January 2005 to October 2009 in our department. Among the patients,29 patients were male and 12 patients were female,with an average age of (37.2 +/- 6.1 ) years (ranged, 17 to 65 years). On admission, the value of injury severity score (ISS) for these patients was above 16 and the average value was 27.4. The therapy process included three stages: first stage,controlling thoracic symptoms and provisionally fixing fracture; second stage, resuscitating and optimizing physiological condition in intensive care unit;third stage, operating for fractures when pathogenic condition was equable. There was no dead case. Pathogenic condition of thorax in all patients regained equable in 5 d to 23 d and long bone shaft fractures were fixed in 10 d to 25 d after injury. There was no seriously operative or postoperative complication. All the patients were followed up, the duration ranged from 6 to 36 months, with an average of 19.4 months. Their respiratory functions were good. The long bone shaft fractures were healed in 10 to 16 weeks among 38 patients. The bone nonunion happened in 1 patient with closed fracture and 2 patients with opened fracture. Damage control orthopedics is a safe strategy for treatment of long bone shaft fractures with severe thoracic trauma. It is suggested that the surgeons should take a staged approach to perform damage control and definitive surgery.
- 1 August 2011
- Vol. 24 (8) , 684-6
[Retrospective study on staged treatment of long bone shaft fractures with severe thoracic trauma].
To evaluate the feasibility and efficacy of staged treatment of patients with long bone shaft fractures and severe thoracic trauma. A retrospective study was performed on 41 patients with long bone shaft fractures and severe thoracic trauma who underwent staged treatment under the guidance of damage control orthopedics from January 2005 to October 2009 in our department. Among the patients,29 patients were male and 12 patients were female,with an average age of (37.2 +/- 6.1 ) years (ranged, 17 to 65 years). On admission, the value of injury severity score (ISS) for these patients was above 16 and the average value was 27.4. The therapy process included three stages: first stage,controlling thoracic symptoms and provisionally fixing fracture; second stage, resuscitating and optimizing physiological condition in intensive care unit;third stage, operating for fractures when pathogenic condition was equable. There was no dead case. Pathogenic condition of thorax in all patients regained equable in 5 d to 23 d and long bone shaft fractures were fixed in 10 d to 25 d after injury. There was no seriously operative or postoperative complication. All the patients were followed up, the duration ranged from 6 to 36 months, with an average of 19.4 months. Their respiratory functions were good. The long bone shaft fractures were healed in 10 to 16 weeks among 38 patients. The bone nonunion happened in 1 patient with closed fracture and 2 patients with opened fracture. Damage control orthopedics is a safe strategy for treatment of long bone shaft fractures with severe thoracic trauma. It is suggested that the surgeons should take a staged approach to perform damage control and definitive surgery.